Patient-specific models of cardiac biomechanics
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Patient-specific models of cardiac function have the potential to improve diagnosis and management of heart disease by integrating medical images with heterogeneous clinical measurements subject to constraints imposed by physical first principles and prior experimental knowledge. We describe new methods for creating three-dimensional patient-specific models of ventricular biomechanics in the failing heart. Three-dimensional bi-ventricular geometry is segmented from cardiac CT images at end-diastole from patients with heart failure. Human myofiber and sheet architecture is modeled using eigenvectors computed from diffusion tensor MR images from an isolated, fixed human organ-donor heart and transformed to the patient-specific geometric model using large deformation diffeomorphic mapping. Semi-automated methods were developed for optimizing the passive material properties while simultaneously computing the unloaded reference geometry of the ventricles for stress analysis. Material properties of active cardiac muscle contraction were optimized to match ventricular pressures measured by cardiac catheterization, and parameters of a lumped-parameter closed-loop model of the circulation were estimated with a circulatory adaptation algorithm making use of information derived from echocardiography. These components were then integrated to create a multi-scale model of the patient-specific heart. These methods were tested in five heart failure patients from the San Diego Veteran’s Affairs Medical Center who gave informed consent. The simulation results showed good agreement with measured echocardiographic and global functional parameters such as ejection fraction and peak cavity pressures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
American Heart Association Writing Group on Myocardial Segmentation and Registration for Cardiac Imaging:, Cerqueira, M. D., Weissman, N. J., Dilsizian, V., Jacobs, A. K., Kaul, S., Laskey, W. K., Pennell, D. J., Rumberger, J. A., Ryan, T., et al. (2002) · Circulation · doi:10.1161/hc0402.102975 · Cited by 6,990
A Riemannian Framework for Tensor Computing
Pennec, X., Fillard, P., & Ayache, N. (2006) · International Journal of Computer Vision · doi:10.1007/s11263-005-3222-z · Cited by 1,550 · cited 1×
“Affine invariant Riemannian frameworks have been proposed which overcome these artifacts but are computationally expensive [34].”
BackgroundBasser, P. J. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080707 · Cited by 1,519 · cited 1×
“Since the magnitude and principal directions of diffusion in tissue are physically constrained by the local micro-structure [7], one can infer the properties of this structure by decomposing D into its eigenvalues ki and eigenvectors v i (i 1⁄4 1;2;3), respectively.”
BackgroundStress-dependent finite growth in soft elastic tissues
Rodriguez, E. K., Hoger, A., & McCulloch, A. D. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90021-3 · Cited by 1,460 · cited 1×
“the unloaded geometry of vascular tissue based on the multiplicative decomposition of the deformation gradient tensor into an elastic and plastic component, typically applied in the modeling of growth [36].”
Self-citationFiber Orientation in the Canine Left Ventricle during Diastole and Systole
STREETER, D. D., SPOTNITZ, H. M., PATEL, D. P., ROSS, J., & SONNENBLICK, E. H. (1969) · Circulation Research · doi:10.1161/01.res.24.3.339 · Cited by 1,454 · cited 1×
“Detailed histological studies [41,25,12] in isolated canine specimens have measured the anisotropic structure of the myocardium which consists of a mesh of myofibers embedded in laminar sheets separated by cleavage planes.”
BackgroundLeGrice, I. J., Smaill, B. H., Chai, L. Z., Edgar, S. G., Gavin, J. B., & Hunter, P. J. (1995) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1995.269.2.h571 · Cited by 842 · cited 1×
“Detailed histological studies [41,25,12] in isolated canine specimens have measured the anisotropic structure of the myocardium which consists of a mesh of myofibers embedded in laminar sheets separated by cleavage planes.”
BackgroundHolzapfel, G. A., & Ogden, R. W. (2009) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2009.0091 · Cited by 836 · cited 5×
“In order to model the resting properties of the myocardium, we make use of the transversely-isotropic form of the constitutive model developed by Holzapfel and Ogden [20].”
BackgroundMethodInfluentialMathematical model of geometry and fibrous structure of the heart
Nielsen, P. M., Le Grice, I. J., Smaill, B. H., & Hunter, P. J. (1991) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1991.260.4.h1365 · Cited by 657 · cited 1×
“[32], the pre-fitted meshes were fitted in the radial (k) coordinate to the reconstructed data by a linear least squares minimization of the projection distance of the data to the interpolated mesh surfaces parameterized at the nodes.”
MethodSpatial transformations of diffusion tensor magnetic resonance images
Alexander, D. C., Pierpaoli, C., Basser, P. J., & Gee, J. C. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.963816 · Cited by 610 · cited 4×
“Compared to the finite strain (FS) strategy, PPD reorients the fibers in a way that is more representative of the mechanical deformation in the reshaping of the host anatomy to the patient anatomy.”
BackgroundInfluentialMagnetic resonance myocardial fiber-orientation mapping with direct histological correlation
Hsu, E. W., Muzikant, A. L., Matulevicius, S. A., Penland, R. C., & Henriquez, C. S. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.274.5.h1627 · Cited by 386 · cited 1×
“Comparing histological measurements of the orientation of these fibers and sheets with results from DT-MRI measurements have confirmed that the fiber and sheet-normal directions coincide with the primary [21,19,37] and tertiary [17] eigenvectors.”
ResultShear properties of passive ventricular myocardium
Dokos, S., Smaill, B. H., Young, A. A., & LeGrice, I. J. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00111.2002 · Cited by 373 · cited 1×
“[13] of ex-vivo canine myocardial tissue.”
Whole-Heart Modeling: Applications to Cardiac Electrophysiology and Electromechanics
Trayanova, N. A. (2011) · Circulation Research · doi:10.1161/circresaha.110.223610 · Cited by 371
Statistical artifacts in diffusion tensor MRI (DT-MRI) caused by background noise
Basser, P. J., & Pajevic, S. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200007)44:1<41::aid-mrm8>3.0.co;2-o · Cited by 318 · cited 1×
“Tensor error metrics [8,3,47] were computed between DðYÞ and DiðYÞ to evaluate the quality of the fiber fit.”
MethodLaminar fiber architecture and three-dimensional systolic mechanics in canine ventricular myocardium
Costa, K. D., Takayama, Y., McCulloch, A. D., & Covell, J. W. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.276.2.h595 · Cited by 313 · cited 1×
“Detailed histological studies [41,25,12] in isolated canine specimens have measured the anisotropic structure of the myocardium which consists of a mesh of myofibers embedded in laminar sheets separated by cleavage planes.”
BackgroundSelf-citationFast and Simple Calculus on Tensors in the Log-Euclidean Framework
Arsigny, V., Fillard, P., Pennec, X., & Ayache, N. (2005) · Lecture Notes in Computer Science · doi:10.1007/11566465_15 · Cited by 286
Progress in Biophysics and Molecular Biology
(1978) · Elsevier eBooks · doi:10.1016/c2013-0-02736-3 · Cited by 261
Arts, T., Delhaas, T., Bovendeerd, P., Verbeek, X., & Prinzen, F. W. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00444.2004 · Cited by 251 · cited 8×
“Finally, parameters of a lumped-parameter closed-loop circulation model that is coupled to the ventricular model were constrained by echocardiographic measurements of cardiac output, aortic and mitral annular dimensions, mitral valve regurgitation, and Doppler blood flows and estimated using a previously validated mod…”
MethodInfluentialKerckhoffs, R. C. P., Neal, M. L., Gu, Q., Bassingthwaighte, J. B., Omens, J. H., & McCulloch, A. D. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9212-7 · Cited by 251 · cited 1×
“These new adapted parameters are then input to the closed-loop circulation model that is coupled to a patient-specific finite-element ventricular geometry model [22].”
MethodSelf-citationMeasuring and Mapping Cardiac Fiber and Laminar Architecture Using Diffusion Tensor MR Imaging
HELM, P., BEG, M. F., MILLER, M. I., & WINSLOW, R. L. (2005) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1341.026 · Cited by 250 · cited 14×
“Comparing histological measurements of the orientation of these fibers and sheets with results from DT-MRI measurements have confirmed that the fiber and sheet-normal directions coincide with the primary [21,19,37] and tertiary [17] eigenvectors.”
ResultInfluentialClinical DT-MRI Estimation, Smoothing, and Fiber Tracking With Log-Euclidean Metrics
Fillard, P., Pennec, X., Arsigny, V., & Ayache, N. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.899173 · Cited by 249
Ex vivo 3D diffusion tensor imaging and quantification of cardiac laminar structure
Helm, P. A., Tseng, H., Younes, L., McVeigh, E. R., & Winslow, R. L. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20622 · Cited by 227 · cited 14×
“Comparing histological measurements of the orientation of these fibers and sheets with results from DT-MRI measurements have confirmed that the fiber and sheet-normal directions coincide with the primary [21,19,37] and tertiary [17] eigenvectors.”
ResultInfluentialA geometric analysis of diffusion tensor measurements of the human brain
Alexander, A. L., Hasan, K., Kindlmann, G., Parker, D. L., & Tsuruda, J. S. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200008)44:2<283::aid-mrm16>3.0.co;2-v · Cited by 212 · cited 1×
“Tensor error metrics [8,3,47] were computed between DðYÞ and DiðYÞ to evaluate the quality of the fiber fit.”
MethodThree-Wall Segment (TriSeg) Model Describing Mechanics and Hemodynamics of Ventricular Interaction
Lumens, J., Delhaas, T., Kirn, B., & Arts, T. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9774-2 · Cited by 211 · cited 2×
“[29] model, the finite element model was contracted isovolumically by activating the fibers.”
BackgroundMethodSpinale, F. (2000) · Cardiovascular Research · doi:10.1016/s0008-6363(99)00431-9 · Cited by 211 · cited 1×
“This might be either due to the softening of tissue associated with matrix metalloproteinase activity in heart failure [40], or due to the hardening of the originally tested canine tissue samples due to the effects of rigor, edema and cutting injury.”
BackgroundDirect histological validation of diffusion tensor MRI in formaldehyde-fixed myocardium
Holmes, A. A., Scollan, D. F., & Winslow, R. L. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200007)44:1<157::aid-mrm22>3.0.co;2-f · Cited by 210 · cited 1×
“Comparing histological measurements of the orientation of these fibers and sheets with results from DT-MRI measurements have confirmed that the fiber and sheet-normal directions coincide with the primary [21,19,37] and tertiary [17] eigenvectors.”
ResultMRI-based finite-element analysis of left ventricular aneurysm
Walker, J. C., Ratcliffe, M. B., Zhang, P., Wallace, A. W., Fata, B., Hsu, E. W., Saloner, D., & Guccione, J. M. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01226.2004 · Cited by 205 · cited 1×
“Previous studies have used some simplifying assumptions for the unloaded geometry; these include using the end-systolic [45] or mid-diastolic [39] geometry as the unloaded state.”
MethodYin, F. C. P., Strumpf, R. K., Chew, P. H., & Zeger, S. L. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90279-x · Cited by 203 · cited 1×
“[48] and the shear tests of Dokos et al.”
BackgroundLarge deformation diffeomorphic metric mapping of vector fields
Cao, Y., Miller, M. I., Winslow, R. L., & Younes, L. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.853923 · Cited by 180 · cited 1×
“Diffeomorphic transformations are smooth one-to-one mappings of one anatomical model domain to another that preserve geometric features [9].”
BackgroundCoupling multi-physics models to cardiac mechanics
Nordsletten, D. A., Niederer, S. A., Nash, M. P., Hunter, P. J., & Smith, N. P. (2011) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2009.11.001 · Cited by 176 · cited 1×
“[33] have made use of the empirical observations by Klotz et al.”
MethodCurrent progress in patient-specific modeling
Neal, M. L., & Kerckhoffs, R. C. P. (2009) · Briefings in Bioinformatics · doi:10.1093/bib/bbp049 · Cited by 166 · cited 1×
“With new advances in modeling and simulations, patient-specific medical images combined with clinical measurements from a variety of invasive and non-invasive modalities can be used to create patient-specific multi-scale models of ventricular biomechanics [43,1,31,30,28,38].”
BackgroundSelf-citationMyocardial Mechanics and Collagen Structure in the Osteogenesis Imperfecta Murine ( oim )
Weis, S. M., Emery, J. L., Becker, K. D., McBride, D. J., Omens, J. H., & McCulloch, A. D. (2000) · Circulation Research · doi:10.1161/01.res.87.8.663 · Cited by 158 · cited 1×
“It has been shown that the fiber architecture is usually conserved over a wide range of conditions between individuals [46].”
BackgroundSelf-citationLength-dependent tension in the failing heart and the efficacy of cardiac resynchronization therapy
Niederer, S. A., Plank, G., Chinchapatnam, P., Ginks, M., Lamata, P., Rhode, K. S., Rinaldi, C. A., Razavi, R., & Smith, N. P. (2011) · Cardiovascular Research · doi:10.1093/cvr/cvq318 · Cited by 155 · cited 2×
“Other workers have also developed methods for constructing patient-specific models of the failing heart [38,31].”
MethodPatient-specific modeling of dyssynchronous heart failure: A case study
Aguado‐Sierra, J., Krishnamurthy, A., Villongco, C., Chuang, J., Howard, E., Gonzales, M. J., Omens, J. H., Krummen, D. E., Narayan, S. M., Kerckhoffs, R. C. P., et al. (2011) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2011.06.014 · Cited by 150
Self-citationScollan, D. F., Holmes, A. A., Zhang, J., & Winslow, R. L. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.1312188 · Cited by 145 · cited 14×
“Comparing histological measurements of the orientation of these fibers and sheets with results from DT-MRI measurements have confirmed that the fiber and sheet-normal directions coincide with the primary [21,19,37] and tertiary [17] eigenvectors.”
ResultInfluentialDT-REFinD: Diffusion Tensor Registration With Exact Finite-Strain Differential
Yeo, B. T. T., Vercauteren, T., Fillard, P., Peyrat, J.-M., Pennec, X., Golland, P., Ayache, N., & Clatz, O. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2025654 · Cited by 89 · cited 3×
“Metrics computed include absolute errors in fractional anisotropy (FA), logarithmic fractional anisotropy (LFA), apparent diffusion coefficient (ADC), volume (Vol), linear anisotropic diffusion (CL), planar anisotropic diffusion (CP), spherical anisotropic diffusion (CS), relative anisotropy (RA), volume ratio (VR), d…”
BackgroundMethodDiffeomorphic Matching of Diffusion Tensor Images
Cao, Y., Miller, M. I., Mori, S., Winslow, R. L., & Laurent Younes, B. (2006) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw.2006.65 · Cited by 79 · cited 1×
“The interpolated material coordinate axes at these locations were reoriented according to the PPD strategy and recomposed into diffusion tensors D using the original ki; preservation of the eigenvalues is reasonable as it implies that tissue anisotropy is maintained during the deformation [10].”
MethodToussaint, N., Maxime Sermesant, B., Stoeck, C. T., Kozerke, S., & Batchelor, P. G. (2010) · Lecture notes in computer science · doi:10.1007/978-3-642-15705-9_51 · Cited by 68 · cited 1×
“Recently, in vivo DTMRI measurements [42] were used to reconstruct myocardial fiber architecture.”
MethodFrank, L. R., Jung, Y., Inati, S., Tyszka, J. M., & Wong, E. C. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.09.010 · Cited by 57
Self-citationStatistical Analysis of the Human Cardiac Fiber Architecture from DT-MRI
Lombaert, H., Peyrat, J., Croisille, P., Rapacchi, S., Fanton, L., Clarysse, P., Delingette, H., & Ayache, N. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-21028-0_22 · Cited by 45 · cited 1×
“A recent statistical analysis [26] of fiber architecture variation in a population of human hearts has revealed that fiber orientations are well preserved between individuals.”
BackgroundToward Patient-Specific Myocardial Models of the Heart
Sermesant, M., Peyrat, J., Chinchapatnam, P. P., Billet, F., Mansi, T., Rhode, K., Delingette, H., Razavi, R., & Ayache, N. (2008) · Heart Failure Clinics · doi:10.1016/j.hfc.2008.02.014 · Cited by 45 · cited 2×
“Other workers have also developed methods for constructing patient-specific models of the failing heart [38,31].”
MethodModeling of Whole-Heart Electrophysiology and Mechanics: Toward Patient-Specific Simulations
Vadakkumpadan, F., Gurev, V., Constantino, J. L., Arevalo, H., & Trayanova, N. A. (2010) · Springer eBooks · doi:10.1007/978-1-4419-6691-9_9 · Cited by 25 · cited 1×
“We also cannot validate the registration of the ex-vivo data to the patient-specific cardiac model, however other workers [44] have validated the use of diffeomorphic maps and similar tensor reorientation strategies to transfer the myofiber architecture between anatomical models.”
Computational modeling of cardiac growth in the post-natal rat with a strain-based growth law
Kerckhoffs, R. C. P. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.11.028 · Cited by 25 · cited 1×
“In the current study, we did not include residual stresses, because these are unknown and can be introduced in multiple ways [23].”
BackgroundSelf-citationStatistical Atlas of Human Cardiac Fibers: Comparison with Abnormal Hearts
Lombaert, H., Peyrat, J., Fanton, L., Cheriet, F., Delingette, H., Ayache, N., Clarysse, P., Magnin, I. E., & Croisille, P. (2012) · Lecture notes in computer science · doi:10.1007/978-3-642-28326-0_21 · Cited by 18 · cited 1×
“It has been shown that fiber directions are more dispersed in abnormal hearts [27].”
BackgroundJoint Estimation and Smoothing of Clinical DT-MRI with a Log-Euclidean Metric
Fillard, P., Arsigny, V., Pennec, X., & Ayache, N. (2005) · HAL · Cited by 17
Personalized Computational Models of the Heart for Cardiac Resynchronization Therapy
Sermesant, M., & Razavi, R. (2010) · Springer eBooks · doi:10.1007/978-1-4419-6691-9_10 · Cited by 15 · cited 1×
“Previous studies have used some simplifying assumptions for the unloaded geometry; these include using the end-systolic [45] or mid-diastolic [39] geometry as the unloaded state.”
Method
Cited by
Computational models in cardiology
Niederer, S. A., Lumens, J., & Trayanova, N. A. (2019) · Nature Reviews Cardiology · doi:10.1038/s41569-018-0104-y · Cited by 434
Computational modeling of cardiac hemodynamics: Current status and future outlook
Mittal, R., Seo, J. H., Vedula, V., Choi, Y. J., Liu, H., Huang, H. H., Jain, S., Younes, L., Abraham, T., & George, R. T. (2016) · Journal of Computational Physics · doi:10.1016/j.jcp.2015.11.022 · Cited by 194
Image-Based Predictive Modeling of Heart Mechanics
Wang, V. Y., Nielsen, P. M. F., & Nash, M. P. (2015) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071114-040609 · Cited by 63
Carruth, E. D., McCulloch, A. D., & Omens, J. H. (2016) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2016.11.004 · Cited by 38
“, 2007), which in turn also affects regional stresses and strains (Krishnamurthy et al., 2013).”
BackgroundSelf-citationNguyen, T. D., Kadri, O. E., & Voronov, R. S. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.529365 · Cited by 19
Metadata
- Authors
- Krishnamurthy, A., Villongco, C. T., Chuang, J., Frank, L. R., Nigam, V., Belezzuoli, E., Stark, P., Krummen, D. E., Narayan, S., Omens, J. H., McCulloch, A. D., & Kerckhoffs, R. C. P.
- Venue
- Journal of Computational Physics
- Publisher
- Elsevier BV
- Published
- 2013-07
- Volume
- 244
- Pages
- 4-21
- ISSN
- 0021-9991 (ISSN-L)
- OpenAlex
- W2089194947
- Cited by
- 181
- References
- 45
- FWCI
- 7.50
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.