CoChat

PFAS use in electronic products and exposure risks during handling and processing of e-waste: A review

Tansel, Berrin · 2022 · Journal of Environmental Management
Cited by 104

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Abstract

Poly- and perfluorinated alkyl substances (PFAS) have been and are used in electronic products due to their unique properties that improve product quality and performance. Ubiquities and persistence of some PFAS detected in environmental samples (water, soil, air) have attracted much attention and regulatory actions in recent years. This review provides an overview of PFAS use in electronic components; trends in quantities of e-waste generation; PFAS exposure pathways during e-waste handling and processing; reported PFAS in environmental samples and samples of serum, blood, and hair collected from people living near and working at e-waste processing sites. Processes used for manufacturing electronic components (e.g., embedded processes, additive manufacturing) make recycling or materials recovery from discarded electronic units and components very difficult and unfeasible. Exposure during numerous processing steps for materials recovery and scavenging at disposal sites can result in PFAS intake through inhalation, ingestion, and dermal routes. Chemical risk assessment approaches have been continuously evolving to consider chemical-specific dosimetric and mechanistic information. While the metabolic fate of PFAS is not well understood, some PFAS bioaccumulate and bind to proteins (but not to lipids) in biota and humans due to their surface-active characteristics and very low solubility in water and fat. It is difficult to associate the adverse health effects due to exposure to e-waste directly to PFAS as there are other factors that could contribute to the observed adverse effects. However, PFAS have been detected in the samples collected from different environmental compartments (e.g., water, soil, leachate, blood sera, rainwater) at and near e-waste processing sites, landfills, and near electronics and optoelectronics industries indicating that e-waste collection, processing, and disposal sites are potential PFAS exposure locations. Better monitoring of e-waste handling sites and detailed epidemiological studies for at risk populations are needed for assessing potential health risks due to PFAS exposure at these sites.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jenvman.2022.115291

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 104

Metadata

Authors
Tansel, B.
Venue
Journal of Environmental Management
Publisher
Elsevier BV
Published
2022-08
Volume
316
Pages
115291
ISSN
0301-4797 (ISSN-L)
OpenAlex
W4280561390
Cited by
104
References
19
FWCI
6.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.