EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
We have developed a toolbox and graphic user interface, EEGLAB, running under the crossplatform MATLAB environment (The Mathworks, Inc.) for processing collections of single-trial and/or averaged EEG data of any number of channels. Available functions include EEG data, channel and event information importing, data visualization (scrolling, scalp map and dipole model plotting, plus multi-trial ERP-image plots), preprocessing (including artifact rejection, filtering, epoch selection, and averaging), independent component analysis (ICA) and time/frequency decompositions including channel and component cross-coherence supported by bootstrap statistical methods based on data resampling. EEGLAB functions are organized into three layers. Top-layer functions allow users to interact with the data through the graphic interface without needing to use MATLAB syntax. Menu options allow users to tune the behavior of EEGLAB to available memory. Middle-layer functions allow users to customize data processing using command history and interactive 'pop' functions. Experienced MATLAB users can use EEGLAB data structures and stand-alone signal processing functions to write custom and/or batch analysis scripts. Extensive function help and tutorial information are included. A 'plug-in' facility allows easy incorporation of new EEG modules into the main menu. EEGLAB is freely available (http://www.sccn.ucsd.edu/eeglab/) under the GNU public license for noncommercial use and open source development, together with sample data, user tutorial and extensive documentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Through the above optimization methods, the model proposed in this paper outperforms other similar studies mentioned above in the classification tasks of DEAP and MAHNOB-HCI datasets.”
From Multimodal Emotion Recognition From EEG Signals and Facial Expressions (2023) · cites this paper as [30]
Experimental — accuracy not yet measuredIn the citing paper
“The artifacts caused by eye blinks and movements were corrected by applying the independent component analysis (ICA) algorithm in the Fieldtrip toolbox (Delorme and Makeig, 2004).”
From Neural Signatures of Hierarchical Linguistic Structures in Second Language Listening Comprehension (2023) · cites this paper as Delorme and Makeig, 2004
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Simple Sequentially Rejective Multiple Test Procedure
(1979) · Scandinavian Journal of Statistics · doi:10.2307/4615733 · Cited by 21,526 · cited 1×
“To compensate for multiple comparisons, significance thresholds may need to be decreased (e.g. Bonferroni, 1950; Holm, 1979).”
BackgroundAn Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986 · cited 1×
“EEGLAB contains an automated version, runica() (Makeig, 1997), of the infomax ICA algorithm (Bell and Sejnowski, 1995) with several enhancements (Amari et al., 1996; Lee et al., 1999) both as a Matlab function and as a stand-alone binary C program that allows faster and less memory-intensive…”
MethodIndependent component analysis: algorithms and applications
Hyvärinen, A., & Oja, E. (2000) · Neural Networks · doi:10.1016/s0893-6080(00)00026-5 · Cited by 8,705 · cited 1×
“The toolbox also allows the user to select any of over 20 available ICA algorithms including JADE (Cardoso and Souloumiac, 1993) and fixed-point ICA (Hyvarinen and Oja, 2000).”
MethodSpectrum estimation and harmonic analysis
Thomson, D. J. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12433 · Cited by 4,418
Measuring phase synchrony in brain signals
Lachaux, J.-P., Rodriguez, E., Martinerie, J., & Varela, F. J. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)8:4<194::aid-hbm4>3.0.co;2-c · Cited by 3,798 · cited 2×
“These interactive functions, called ‘pop’ functions, work in two modes.”
BackgroundRemoving electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334 · cited 4×
“ICA algorithms have proven capable of isolating both artifactual and neurally generated EEG sources (Makeig et al., 1999; Jung et al., 2000) whose EEG contributions, across the training data, are maximally independent of one another.”
BackgroundMethodInfluentialSelf-citationBlind beamforming for non-gaussian signals
Cardoso, J. F., & Souloumiac, A. (1993) · IEE Proceedings F Radar and Signal Processing · doi:10.1049/ip-f-2.1993.0054 · Cited by 2,738
Independent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
Self-citationLee, T.-W., Girolami, M., & Sejnowski, T. J. (1999) · Neural Computation · doi:10.1162/089976699300016719 · Cited by 1,967 · cited 4×
“EEGLAB contains an automated version, runica() (Makeig, 1997), of the infomax ICA algorithm (Bell and Sejnowski, 1995) with several enhancements (Amari et al., 1996; Lee et al., 1999) both as a Matlab function and as a stand-alone binary C program that allows faster and less memory-intensive computation.”
MethodInfluentialPerception's shadow: long-distance synchronization of human brain activity
Rodriguez, E., George, N., Lachaux, J.-P., Martinerie, J., Renault, B., & Varela, F. J. (1999) · Nature · doi:10.1038/17120 · Cited by 1,915 · cited 2×
“, 1999) and with visual awareness (Rodriguez et al., 1999).”
BackgroundA New Learning Algorithm for Blind Signal Separation
Амари, Ш.-И., Cichocki, A. S., & Yang, H. H. (1995) · Cited by 1,904
Dynamic Brain Sources of Visual Evoked Responses
Makeig, S., Westerfield, M., Jung, T.-P., Enghoff, S., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2002) · Science · doi:10.1126/science.1066168 · Cited by 1,630 · cited 9×
“…the biologically plausible sources ICA identifies in EEG data have scalp maps nearly fitting the projection of a single equivalent current dipole (Jung et al., 2001; Makeig et al., 2002), and are therefore quite compatible with the projection to the scalp electrodes of synchronous local field…”
BackgroundMethodInfluentialSelf-citationvon Stein, A., & Sarnthein, J. (2000) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(00)00172-0 · Cited by 1,553 · cited 1×
“Also, bi-coherence between frequencies cannot yet be assessed within EEGLAB (e.g., von Stein and Sarnthein, 2000; Lachaux et al., 2003).”
BackgroundStimulus Specificity of Phase-Locked and Non-Phase-Locked 40 Hz Visual Responses in Human
Tallon-Baudry, C., Bertrand, O., Delpuech, C., & Pernier, J. (1996) · The Journal of Neuroscience · doi:10.1523/jneurosci.16-13-04240.1996 · Cited by 1,534 · cited 2×
“The measure was introduced by Tallon-Baudry et al. (1996) and termed a ‘phase locking factor.”
BackgroundMethodBlind separation of auditory event-related brain responses into independent components
Makeig, S., Jung, T.-P., Bell, A. J., Ghahremani, D., & Sejnowski, T. J. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.20.10979 · Cited by 1,206 · cited 5×
“…of Matlab functions for signal processing and visualization of EEG data including runica() , a function for automated infomax ICA decomposition (Makeig et al., 1997), ERP-image plotting (Jung et al., 1999; Makeig et al., 1999), a method of visualizing time-locked potential variations across…”
BackgroundMethodInfluentialSelf-citationComparison of Hilbert transform and wavelet methods for the analysis of neuronal synchrony
Le Van Quyen, M., Foucher, J., Lachaux, J.-P., Rodriguez, E., Lutz, A., Martinerie, J., & Varela, F. J. (2001) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(01)00372-7 · Cited by 887
Auditory event-related dynamics of the EEG spectrum and effects of exposure to tones
Makeig, S. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90110-h · Cited by 844 · cited 3×
“measures: (1) the event-related spectral perturbation (ERSP), measuring mean event-related changes in the power spectrum at a data channel or component (Makeig, 1993), (2) inter-trial coherence (ITC magnitude and phase, also called phase-locking factor) at single channels or components, and (3) event-related cross-coh…”
BackgroundMethodSelf-citationPfurtscheller, G., & Aranibar, A. (1979) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(79)90063-4 · Cited by 758
Analysis and visualization of single‐trial event‐related potentials
Jung, T., Makeig, S., Westerfield, M., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2001) · Human Brain Mapping · doi:10.1002/hbm.1050 · Cited by 655 · cited 3×
“…(Pfurtscheller and Aranibar, 1979; Bressler and Freeman, 1980; Makeig, 1993; Neuenschwander and Varela, 1993; Tallon-Baudry et al., 1996; Weiss and Rappelsberger, 1996) and Independent Component Analysis (ICA) (Makeig et al., 1996; Makeig et al., 1997; Makeig et al., 1999; Jung et al., 2001).”
BackgroundSelf-citationSulle medie multiple di potenze
Bonferroni, C. (1950) · Bollettino Della Unione Matematica Italiana · Cited by 534
A Probability Distribution and its Uses in Fitting Data
Ramberg, J. S., Dudewicz, E. J., Tadikamalla, P. R., & Mykytka, E. F. (1979) · Technometrics · doi:10.1080/00401706.1979.10489750 · Cited by 426 · cited 1×
“Since it is not reasonable to compute an unlimited amount of surrogate data to estimate very low probability thresholds heuristically, we have implemented a method to fit the observed surrogate data distribution using a fourth order distribution fit (Ramberg et al., 1979).”
MethodMakeig, S., Westerfield, M., Jung, T.-P., Covington, J., Townsend, J., Sejnowski, T. J., & Courchesne, E. (1999) · The Journal of Neuroscience · doi:10.1523/jneurosci.19-07-02665.1999 · Cited by 385 · cited 12×
“ICA can be viewed as a more powerful rotation method, though in practice ICA is usually applied to the original data without PCA pre-processing (for details, see Makeig et al., 1999).”
BackgroundMethodInfluentialSelf-citationFrequency analysis of olfactory system EEG in cat, rabbit, and rat
Bressler, S. L., & Freeman, W. J. (1980) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(80)90319-3 · Cited by 374
A unifying information-theoretic framework for independent component analysis
Lee, T.-W., Girolami, M., Bell, A. J., & Sejnowski, T. J. (2000) · Computers & Mathematics with Applications · doi:10.1016/s0898-1221(00)00101-2 · Cited by 355 · cited 3×
“expectancy of a target stimulus (Makeig et al., 1999) and with visual awareness (Rodriguez et al., 1999). The sufficiency of studying average ERPs has also been questioned by Makeig et al. (2002), who showed that some average ERP peaks may result from partial synchronization of oscillatory EEG processes to time lockin…”
BackgroundMethodCommentary and Opinion: II. Statistical Parametric Mapping: Ontology and Current Issues
Friston, K. J. (1995) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1995.45 · Cited by 266 · cited 1×
“EEGLAB extends the collection of publicly available Matlab packages for brain imaging including SPM (Friston, 1995) and FRMLAB (Duann et al., 2002) for functional MRI studies and Brainstorm (Baillet et al., 1999) for EEG/MEG source analysis.”
MethodSingle-Trial Variability in Event-Related BOLD Signals
Duann, J.-R., Jung, T.-P., Kuo, W.-J., Yeh, T.-C., Makeig, S., Hsieh, J.-C., & Sejnowski, T. J. (2002) · NeuroImage · doi:10.1006/nimg.2001.1049 · Cited by 215 · cited 3×
“ICA is now being applied to many biomedical signal processing problems including decomposing fMRI data (Duann et al., 2002b) and speech and noise separation (Park et al., 1999).”
MethodSelf-citationComplex independent component analysis of frequency-domain electroencephalographic data
Anemüller, J., Sejnowski, T. J., & Makeig, S. (2003) · Neural Networks · doi:10.1016/j.neunet.2003.08.003 · Cited by 212
Self-citationWeiß, S., & Rappelsberger, P. (1996) · Neuroscience Letters · doi:10.1016/0304-3940(96)12581-7 · Cited by 150
Esposito, F., Formisano, E., Seifritz, E., Goebel, R., Morrone, R., Tedeschi, G., & Di Salle, F. (2002) · Human Brain Mapping · doi:10.1002/hbm.10034 · Cited by 128 · cited 2×
“Therefore, different ICA decompositions may give slightly different results, as has been shown for neural ensemble data (Laubach et al., 1999) and fMRI data (Duann et al., 2001; Esposito et al., 2002).”
MethodResultFrom single-trial EEG to brain area dynamics
Delorme, A., Makeig, S., Fabre‐Thorpe, M., & B, T. J. S. A. (2002) · Neurocomputing · doi:10.1016/s0925-2312(02)00415-0 · Cited by 101 · cited 4×
“Even though independent components were identified by ICA as being (maximally) independent over the whole time range, they may exhibit partial but statistically significant synchronization, within specific event-related time/frequency windows (Delorme et al., 2002).”
BackgroundMethodInfluentialSelf-citationIndependent component analyses for quantifying neuronal ensemble interactions
Laubach, M., Shuler, M. G. H., & Nicolelis, M. A. L. (1999) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(99)00131-4 · Cited by 96 · cited 2×
“Therefore, different ICA decompositions may give slightly different results, as has been shown for neural ensemble data (Laubach et al., 1999) and fMRI data (Duann et al.”
ResultResponse: Event-related brain dynamics – unifying brain electrophysiology
Makeig, S. (2002) · Trends in Neurosciences · doi:10.1016/s0166-2236(02)02198-7 · Cited by 79 · cited 1×
“…event-related dynamics that do not appear in, or are poorly represented in response averages, and second, ignores ongoing EEG processes that may be partially time and phase-locked by experimental events, thereby contributing portions of response averages (Delorme et al., 2002; Makeig et al., 2002).”
Self-citationAnalyzing and Visualizing Single-Trial Event-Related Potentials
Jung, T., Makeig, S., Westerfield, M., Townsend, J., Courchesne, E., & B, T. J. S. A. (1998) · neural information processing systems · Cited by 69
Self-citationEEG changes accompanying learned regulation of 12-Hz EEG activity
Delorme, A., & Makeig, S. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814428 · Cited by 67 · cited 1×
“Using this toolbox, we have demonstrated the advantages of combining ICA, time-frequency analysis, and multi-trial visualization in several publications (e.g., Makeig et al., 1999; Delorme et al., 2002; Makeig et al., 2002; Delorme and Makeig, 2003).”
MethodSelf-citationBlind Separation of Event-Related Brain Responses into Independent Components
Makeig, S., Jung, T., Bell, A. J., Ghahremani, D. G., & Sejnowski, T. J. (1996) · Defense Technical Information Center (DTIC) · doi:10.21236/ada381505 · Cited by 64
Self-citationA simple measure of correlation across time, frequency and space between continuous brain signals
Lachaux, J.-P., Chávez, M., & Lutz, A. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00358-8 · Cited by 57
Visually Triggered Neuronal Oscillations in the Pigeon: An Autocorrelation Study of Tectal Activity
Neuenschwander, S., & Varela, F. J. (1993) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.1993.tb00939.x · Cited by 56 · cited 1×
“…engineering and information theory, including time/frequency analysis (Pfurtscheller and Aranibar, 1979; Bressler and Freeman, 1980; Makeig, 1993; Neuenschwander and Varela, 1993; Tallon-Baudry et al., 1996; Weiss and Rappelsberger, 1996) and Independent Component Analysis (ICA) (Makeig et al.,…”
BackgroundPauluis, Q., Baker, S. N., & Olivier, E. (1999) · Journal of Computational Neuroscience · doi:10.1023/a:1008804916112 · Cited by 55
Subband-based blind signal separationfor noisy speech recognition
Park, H., Jung, H., Lee, T.-W., & Lee, S.-Y. (1999) · Electronics Letters · doi:10.1049/el:19991358 · Cited by 53 · cited 1×
“ICA is now being applied to many biomedical signal processing problems including decomposing fMRI data (Duann et al., 2002b) and speech and noise separation (Park et al., 1999).”
MethodBlind separation and blind deconvolution: an information-theoretic approach
Bell, A. J., & B, T. J. S. A. (2002) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.1995.479719 · Cited by 48
Artificial damping techniques for scalar waves in the frequency domain
Kim, S., & Lee, M. A. (1996) · Computers & Mathematics with Applications · doi:10.1016/0898-1221(96)00025-9 · Cited by 36
On subband-based blind separation for noisy speech recognition
Park, H.-M., Jung, H.-Y., Lee, S.-Y., & Lee, T.-W. (n.d.) · ICONIP'99. ANZIIS'99 & ANNES'99 & ACNN'99. 6th International Conference on Neural Information Processing. Proceedings (Cat. No.99EX378) · doi:10.1109/iconip.1999.843987
Research works printed but not linked: 3
- Baillet S, Mosher JC, Leahy RM, Shattuck DW. BrainStorm: a Matlab Toolbox for the Processing of MEG and EEG Signals. Proceedings of the 5th Int. Conf. on Human Brain Map., Neuroimage, 1999; 9: 246.
- Duann JR, Jung TP, Kuo WJ, Yeh TC, Makeig S, Hsieh JC, Sejnowski TJ. Single-trial variability in event-related BOLD signals. Neuroimage, 2002b; 15: 823-35. · DOI · Paper page
- Jung TP, Makeig S, Westerfield M, Townsend J, Courchesne E, Sejnowski TJ. Analyzing and Visualizing Single-trial Eventrelated Potentials. Adv. Neural Inf. Process. Syst., 1999; 11: 11824.
Cited by
Oostenveld, R., Fries, P., Maris, E., & Schoffelen, J.-M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/156869 · Cited by 10,323
“This implements a variety of blind source separation methods, such as independent component analysis (ICA, based on code from the EEGLAB toolbox [1]), and principal component analysis (PCA).”
MethodEEGNet: a compact convolutional neural network for EEG-based brain-computer interfaces
Lawhern, V. J., Solon, A. J., Waytowich, N. R., Gordon, S. M., Hung, C. P., & Lance, B. J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aace8c · Cited by 5,115
“The data were referenced to linked mastoids, bandpass filtered, using an FIR filter implemented in EEGLAB [53], between 0.”
MethodInfluentialEEGNet: A Compact Convolutional Network for EEG-based Brain-Computer Interfaces
Lawhern, V. J., Solon, A. J., Waytowich, N. R., Gordon, S. M., Hung, C. P., & Lance, B. J. (2016) · arXiv · doi:10.48550/arxiv.1611.08024 · Cited by 5,105
“The data were referenced to linked mastoids, bandpass filtered, using an FIR filter implemented in EEGLAB [53], between 0.”
MethodInfluentialMEG and EEG data analysis with MNE-Python
Gramfort, A. (2013) · Frontiers in Neuroscience · doi:10.3389/fnins.2013.00267 · Cited by 3,784
“Several of such software packages for M/EEG data processing exist, including Brainstorm (Tadel et al., 2011), EEGLAB [Delorme and Makeig (2004) and Delorme et al. (2011)], FieldTrip (Oostenveld et al., 2011), NutMeg (Dalal et al., 2011) and SPM (Litvak et al., 2011).”
MethodBrainstorm: A User-Friendly Application for MEG/EEG Analysis
Tadel, F., Baillet, S., Mosher, J. C., Pantazis, D., & Leahy, R. M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/879716 · Cited by 3,677
“Other preprocessing operations can be performed easily with other programs (EEGLab [35], FieldTrip, or MNE [36]) and results then imported into Brainstorm as described above.”
Method
Metadata
- Authors
- Delorme, A., & Makeig, S.
- Affiliations
- University of California San Diego (US)
- ORCID
- Makeig, Scott
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2004-03
- Volume
- 134
- Issue
- 1
- Pages
- 9-21
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2128495200
- Cited by
- 24,371
- References
- 39
- Citations by year
- 2026: 1965 · 2025: 2472 · 2024: 2191 · 2023: 2114 · 2022: 1984 · 2021: 1999 · 2020: 1784 · 2019: 1662 · 2018: 1378 · 2017: 1260 · 2016: 1022 · 2015: 921 · 2014: 766 · 2013: 683 · 2012: 515
- FWCI
- 62.72
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Computer Science › Signal Processing › Blind Source Separation Techniques
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Keywords
- EEGLAB, single-trial EEG, independent component analysis, event-related potentials, EEG preprocessing, artifact rejection, time-frequency decomposition, cross-coherence, bootstrapping, dipole modeling, open source software, MATLAB toolbox
- MeSH terms
- Computer Simulation, Electroencephalography, Evoked Potentials, Software
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.