EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
We have developed a toolbox and graphic user interface, EEGLAB, running under the crossplatform MATLAB environment (The Mathworks, Inc.) for processing collections of single-trial and/or averaged EEG data of any number of channels. Available functions include EEG data, channel and event information importing, data visualization (scrolling, scalp map and dipole model plotting, plus multi-trial ERP-image plots), preprocessing (including artifact rejection, filtering, epoch selection, and averaging), independent component analysis (ICA) and time/frequency decompositions including channel and component cross-coherence supported by bootstrap statistical methods based on data resampling. EEGLAB functions are organized into three layers. Top-layer functions allow users to interact with the data through the graphic interface without needing to use MATLAB syntax. Menu options allow users to tune the behavior of EEGLAB to available memory. Middle-layer functions allow users to customize data processing using command history and interactive 'pop' functions. Experienced MATLAB users can use EEGLAB data structures and stand-alone signal processing functions to write custom and/or batch analysis scripts. Extensive function help and tutorial information are included. A 'plug-in' facility allows easy incorporation of new EEG modules into the main menu. EEGLAB is freely available (http://www.sccn.ucsd.edu/eeglab/) under the GNU public license for noncommercial use and open source development, together with sample data, user tutorial and extensive documentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Through the above optimization methods, the model proposed in this paper outperforms other similar studies mentioned above in the classification tasks of DEAP and MAHNOB-HCI datasets.”
From Multimodal Emotion Recognition From EEG Signals and Facial Expressions (2023) · cites this paper as [30]
Experimental — accuracy not yet measuredIn the citing paper
“The artifacts caused by eye blinks and movements were corrected by applying the independent component analysis (ICA) algorithm in the Fieldtrip toolbox (Delorme and Makeig, 2004).”
From Neural Signatures of Hierarchical Linguistic Structures in Second Language Listening Comprehension (2023) · cites this paper as Delorme and Makeig, 2004
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Simple Sequentially Rejective Multiple Test Procedure
(1979) · Scandinavian Journal of Statistics · doi:10.2307/4615733 · Cited by 21,526 · cited 1×
“To compensate for multiple comparisons, significance thresholds may need to be decreased (e.g. Bonferroni, 1950; Holm, 1979).”
BackgroundAn Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986 · cited 1×
“EEGLAB contains an automated version, runica() (Makeig, 1997), of the infomax ICA algorithm (Bell and Sejnowski, 1995) with several enhancements (Amari et al., 1996; Lee et al., 1999) both as a Matlab function and as a stand-alone binary C program that allows faster and less memory-intensive…”
MethodIndependent component analysis: algorithms and applications
Hyvärinen, A., & Oja, E. (2000) · Neural Networks · doi:10.1016/s0893-6080(00)00026-5 · Cited by 8,705 · cited 1×
“The toolbox also allows the user to select any of over 20 available ICA algorithms including JADE (Cardoso and Souloumiac, 1993) and fixed-point ICA (Hyvarinen and Oja, 2000).”
MethodSpectrum estimation and harmonic analysis
Thomson, D. J. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12433 · Cited by 4,418
Measuring phase synchrony in brain signals
Lachaux, J.-P., Rodriguez, E., Martinerie, J., & Varela, F. J. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)8:4<194::aid-hbm4>3.0.co;2-c · Cited by 3,798 · cited 2×
“These interactive functions, called ‘pop’ functions, work in two modes.”
BackgroundRemoving electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334 · cited 4×
“ICA algorithms have proven capable of isolating both artifactual and neurally generated EEG sources (Makeig et al., 1999; Jung et al., 2000) whose EEG contributions, across the training data, are maximally independent of one another.”
BackgroundMethodInfluentialSelf-citationBlind beamforming for non-gaussian signals
Cardoso, J. F., & Souloumiac, A. (1993) · IEE Proceedings F Radar and Signal Processing · doi:10.1049/ip-f-2.1993.0054 · Cited by 2,738
Independent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
Self-citationLee, T.-W., Girolami, M., & Sejnowski, T. J. (1999) · Neural Computation · doi:10.1162/089976699300016719 · Cited by 1,967 · cited 4×
“EEGLAB contains an automated version, runica() (Makeig, 1997), of the infomax ICA algorithm (Bell and Sejnowski, 1995) with several enhancements (Amari et al., 1996; Lee et al., 1999) both as a Matlab function and as a stand-alone binary C program that allows faster and less memory-intensive computation.”
MethodInfluentialPerception's shadow: long-distance synchronization of human brain activity
Rodriguez, E., George, N., Lachaux, J.-P., Martinerie, J., Renault, B., & Varela, F. J. (1999) · Nature · doi:10.1038/17120 · Cited by 1,915 · cited 2×
“, 1999) and with visual awareness (Rodriguez et al., 1999).”
Background
Research works printed but not linked: 3
- Baillet S, Mosher JC, Leahy RM, Shattuck DW. BrainStorm: a Matlab Toolbox for the Processing of MEG and EEG Signals. Proceedings of the 5th Int. Conf. on Human Brain Map., Neuroimage, 1999; 9: 246.
- Duann JR, Jung TP, Kuo WJ, Yeh TC, Makeig S, Hsieh JC, Sejnowski TJ. Single-trial variability in event-related BOLD signals. Neuroimage, 2002b; 15: 823-35. · DOI · Paper page
- Jung TP, Makeig S, Westerfield M, Townsend J, Courchesne E, Sejnowski TJ. Analyzing and Visualizing Single-trial Eventrelated Potentials. Adv. Neural Inf. Process. Syst., 1999; 11: 11824.
Cited by
Oostenveld, R., Fries, P., Maris, E., & Schoffelen, J.-M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/156869 · Cited by 10,323
“This implements a variety of blind source separation methods, such as independent component analysis (ICA, based on code from the EEGLAB toolbox [1]), and principal component analysis (PCA).”
MethodEEGNet: a compact convolutional neural network for EEG-based brain-computer interfaces
Lawhern, V. J., Solon, A. J., Waytowich, N. R., Gordon, S. M., Hung, C. P., & Lance, B. J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aace8c · Cited by 5,115
“The data were referenced to linked mastoids, bandpass filtered, using an FIR filter implemented in EEGLAB [53], between 0.”
MethodInfluentialEEGNet: A Compact Convolutional Network for EEG-based Brain-Computer Interfaces
Lawhern, V. J., Solon, A. J., Waytowich, N. R., Gordon, S. M., Hung, C. P., & Lance, B. J. (2016) · arXiv · doi:10.48550/arxiv.1611.08024 · Cited by 5,105
“The data were referenced to linked mastoids, bandpass filtered, using an FIR filter implemented in EEGLAB [53], between 0.”
MethodInfluentialMEG and EEG data analysis with MNE-Python
Gramfort, A. (2013) · Frontiers in Neuroscience · doi:10.3389/fnins.2013.00267 · Cited by 3,784
“Several of such software packages for M/EEG data processing exist, including Brainstorm (Tadel et al., 2011), EEGLAB [Delorme and Makeig (2004) and Delorme et al. (2011)], FieldTrip (Oostenveld et al., 2011), NutMeg (Dalal et al., 2011) and SPM (Litvak et al., 2011).”
MethodBrainstorm: A User-Friendly Application for MEG/EEG Analysis
Tadel, F., Baillet, S., Mosher, J. C., Pantazis, D., & Leahy, R. M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/879716 · Cited by 3,677
“Other preprocessing operations can be performed easily with other programs (EEGLab [35], FieldTrip, or MNE [36]) and results then imported into Brainstorm as described above.”
MethodERPLAB: an open-source toolbox for the analysis of event-related potentials
Lopez-Calderon, J., & Luck, S. J. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00213 · Cited by 2,584
“A convenient GUI is an important aspect of an ERP analysis package.”
MethodICLabel: An automated electroencephalographic independent component classifier, dataset, and website
Pion-Tonachini, L., Kreutz-Delgado, K., & Makeig, S. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.026 · Cited by 2,267
“The end result is made freely and easily available through the ICLabel plugin for the EEGLAB software environment (Delorme and Makeig, 2004; Delorme et al., 2011).”
Self-citationMNE software for processing MEG and EEG data
Gramfort, A., Luessi, M., Larson, E., Engemann, D. A., Strohmeier, D., Brodbeck, C., Parkkonen, L., & Hämäläinen, M. S. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.10.027 · Cited by 1,951
“Multiple academic software packages for M/EEG data processing exist, e.g., Brainstorm (Tadel et al., 2011), EEGLAB (Delorme and Makeig, 2004; Delorme et al., 2011), FieldTrip (Oostenveld et al., 2011), NutMeg (Dalal et al., 2011) and SPM (Litvak et al., 2011), all implemented in Matlab, with some dependencies on exter…”
MethodDelorme, A., Sejnowski, T., & Makeig, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.004 · Cited by 1,759
“The EEGLAB routines that implement these detection methods use this strategy (Delorme and Makeig, 2004).”
MethodInfluentialSelf-citationVideo game training enhances cognitive control in older adults
Anguera, J. A., Boccanfuso, J., Rintoul, J. L., Al-Hashimi, O., Faraji, F., Janowich, J., Kong, E., Larraburo, Y., Rolle, C., Johnston, E., et al. (2013) · Nature · doi:10.1038/nature12486 · Cited by 1,666
Mining event-related brain dynamics
Makeig, S., Debener, S., Onton, J., & Delorme, A. (2004) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2004.03.008 · Cited by 1,493
“An open source toolbox, EEGLAB, implementing the analysis approach outlined here is freely available (www. sccn.ucsd.edu/eeglab; [ 35 ]).”
BackgroundMethodInfluentialSelf-citationADJUST: An automatic EEG artifact detector based on the joint use of spatial and temporal features
Mognon, A., Jovicich, J., Bruzzone, L., & Buiatti, M. (2011) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01061.x · Cited by 1,290
Mass univariate analysis of event‐related brain potentials/fields I: A critical tutorial review
Groppe, D. M., Urbach, T. P., & Kutas, M. (2011) · Psychophysiology · doi:10.1111/j.1469-8986.2011.01273.x · Cited by 1,169
“The software is compatible with the EEGLAB toolbox (Delorme & Makeig, 2004) as well as the ERPLAB toolbox (http://erpinfo.org/ erplab).”
MethodControlling low-level image properties: The SHINE toolbox
Willenbockel, V., Sadr, J., Fiset, D., Horne, G. O., Gosselin, F., & Tanaka, J. W. (2010) · Behavior Research Methods · doi:10.3758/brm.42.3.671 · Cited by 1,166
“…the Signal Processing Toolbox, there are a number of freely available ones, such as the Psychophysics Toolbox (Brainard, 1997; Pelli, 1997), EEGLAB (Delorme & Makeig, 2004), the Biopsychology Toolbox (Rose, Otto, & Dittrich, 2008), and the alignment toolbox from our own lab…”
MethodInfluentialKatsigiannis, S., & Ramzan, N. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2688239 · Cited by 1,135
“Three separate bandpass Hamming sinc linear phase FIR filters are applied using the EEGLAB [30] toolbox in order to extract only the frequencies inside the ranges of interest.”
MethodInfluentialFASTER: Fully Automated Statistical Thresholding for EEG artifact Rejection
Nolan, H., Whelan, R., & Reilly, R. B. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.07.015 · Cited by 1,077
Debener, S., Ullsperger, M., Siegel, M., Fiehler, K., von Cramon, D. Y., & Engel, A. K. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.3286-05.2005 · Cited by 1,062
“Further processing of the 250 Hz downsampled data was performed using Matlab 6.5 (MathWorks, Natick, MA) and EEGLAB 4.51 (Delorme and Makeig, 2004), a freely available open source software toolbox (EEGLAB toolbox for single-trial EEG data analysis, Swartz Center for Computational Neurosciences, La…”
MethodInfluentialTo See or Not to See: Prestimulus α Phase Predicts Visual Awareness
Mathewson, K. E., Gratton, G., Fabiani, M., Beck, D. M., & Ro, T. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.3963-08.2009 · Cited by 1,007
“All processing and analyses were performed using custom scripts written in Matlab (The MathWorks) and with the EEGLAB toolbox (Delorme and Makeig, 2004).”
MethodEEG artifact removal—state-of-the-art and guidelines
Urigüen, J. A., & Garcia-Zapirain, B. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/031001 · Cited by 963
“In fact, leading researchers in the field have been using ICA and improved variations for the last 15 years—for example Vigário [21, 44, 159, 160], Hÿvarinen [161, 162], Oja [21, 159, 161, 162], James [20, 39, 55, 108], Makeig [43, 52, 97, 102], Jung [43, 52, 97], Comon [41] and Cichocki [83, 163], among others.”
BackgroundMethodInfluentialTranscranial focused ultrasound modulates the activity of primary somatosensory cortex in humans
Legon, W., Sato, T. F., Opitz, A., Mueller, J., Barbour, A., Williams, A., & Tyler, W. J. (2014) · Nature Neuroscience · doi:10.1038/nn.3620 · Cited by 981
Theta-gamma coupling increases during the learning of item-context associations
Tort, A. B. L., Komorowski, R. W., Manns, J. R., Kopell, N. J., & Eichenbaum, H. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0911331106 · Cited by 919
Vanhaudenhuyse, A., Noirhomme, Q., Tshibanda, L. J.-F., Bruno, M.-A., Boveroux, P., Schnakers, C., Soddu, A., Perlbarg, V., Ledoux, D., Brichant, J.-F., et al. (2010) · Brain · doi:10.1093/brain/awp313 · Cited by 911
“Two-tailed permutation tests (Nichols and Holmes, 2002) looked for group differences using EEGLAB (Delorme and Makeig, 2004) implemented in MATLAB 7 (Mathworks, Natick, MA, USA) and results were thresholded for significance at P50.”
MethodSommermeyer, D., Hudecek, M., Kosasih, P. L., Gogishvili, T., Maloney, D. G., Turtle, C. J., & Riddell, S. R. (2016) · Leukemia · doi:10.1038/leu.2015.247 · Cited by 867
Frontal midline EEG dynamics during working memory
Onton, J., Delorme, A., & Makeig, S. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.04.014 · Cited by 850
“01, uncorrected for multiple comparisons) were first identified by comparing the observed mean ERSP values to bootstrap measures of baseline spectral variability during the Fixation period (Delorme and Makeig, 2004).”
BackgroundMethodInfluentialSelf-citationElectroencephalogram signatures of loss and recovery of consciousness from propofol
Purdon, P. L., Pierce, E. T., Mukamel, E. A., Prerau, M. J., Walsh, J. L., Wong, K. F. K., Salazar-Gomez, A. F., Harrell, P. G., Sampson, A. L., Cimenser, A., et al. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1221180110 · Cited by 854
“Scalp EEG plots were performed using the topoplot function in EEGLab (78).”
MethodChaumon, M., Bishop, D. V. M., & Busch, N. A. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.02.025 · Cited by 833
EEG Source Imaging: A Practical Review of the Analysis Steps
Michel, C. M., & Brunet, D. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00325 · Cited by 705
“A comprehensive overview of different academic software applications can be found in a special issue of the Journal Computational Intelligence and Neuroscience (30), where programs such as BrainStorm (31), EEGLAB (32), FieldTrip (33), NUTMEG (34), SPM (35), andCartool (29) are described.”
MethodIndependent EEG Sources Are Dipolar
Delorme, A., Palmer, J., Onton, J., Oostenveld, R., & Makeig, S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0030135 · Cited by 810
“Data were analyzed by custom MATLAB scripts built on the open source EEGLAB toolbox [48].”
MethodSelf-citationDigital filter design for electrophysiological data – a practical approach
Widmann, A., Schröger, E., & Maess, B. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.08.002 · Cited by 711
“The EEGLAB 13 (SVN rev. 10348; Delorme and Makeig, 2004; Delorme et al., 2011) default filter is the “Basic FIR filter (new)” implementing zero-phase Hamming-windowed sinc FIR filter on the basis of the firfilt EEGLAB plugin (version 1.”
InfluentialMotor Patterns in Human Walking and Running
Cappellini, G., Ivanenko, Y. P., Poppele, R. E., & Lacquaniti, F. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00081.2006 · Cited by 798
“5; www.sccn.ucsd. edu/eeglab/) (Delorme and Makeig 2004) running on Matlab v7.”
Bin, G., Gao, X., Yan, Z., Hong, B., & Gao, S. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046002 · Cited by 773
A MATLAB toolbox for Granger causal connectivity analysis
Seth, A. K. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.11.020 · Cited by 750
The neural correlates of dreaming
Siclari, F., Baird, B., Perogamvros, L., Bernardi, G., LaRocque, J. J., Riedner, B., Boly, M., Postle, B. R., & Tononi, G. (2017) · Nature Neuroscience · doi:10.1038/nn.4545 · Cited by 758
Mental Training Affects Distribution of Limited Brain Resources
Slagter, H. A., Lutz, A., Greischar, L. L., Francis, A. D., Nieuwenhuis, S., Davis, J. M., & Davidson, R. J. (2007) · PLoS Biology · doi:10.1371/journal.pbio.0050138 · Cited by 757
“EEGLAB [26] and Matlab (Mathworks, http:// www.”
InfluentialA supramodal accumulation-to-bound signal that determines perceptual decisions in humans
O'Connell, R. G., Dockree, P. M., & Kelly, S. P. (2012) · Nature Neuroscience · doi:10.1038/nn.3248 · Cited by 755
Bedside detection of awareness in the vegetative state: a cohort study
Cruse, D., Chennu, S., Chatelle, C., Bekinschtein, T. A., Fernández-Espejo, D., Pickard, J. D., Laureys, S., & Owen, A. M. (2011) · The Lancet · doi:10.1016/s0140-6736(11)61224-5 · Cited by 712
Neural signature of the conscious processing of auditory regularities
Bekinschtein, T. A., Dehaene, S., Rohaut, B., Tadel, F., Cohen, L., & Naccache, L. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0809667106 · Cited by 738
“Remaining electrodes were submitted to automatic artifact rejection ( -300 V threshold), visually inspected, low-pass-filtered (70 Hz), and notch-filtered (50 Hz) by using EEGLAB software (39).”
MethodNatural Frequencies of Human Corticothalamic Circuits
Rosanova, M., Casali, A., Bellina, V., Resta, F., Mariotti, M., & Massimini, M. (2009) · Journal of Neuroscience · doi:10.1523/jneurosci.0445-09.2009 · Cited by 695
“The procedure was im- plemented using the public license toolbox EEGLAB (Delorme and Makeig, 2004) (for more details about ERSP calculation, see supplemental Appendix B, available at www.jneurosci.org as supplemental material).”
MethodSynchronization of neural activity across cortical areas correlates with conscious perception
Melloni, L., Molina, C., Pena, M., Torres, D., Singer, W., & Rodriguez, E. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.4623-06.2007 · Cited by 716
“The EEGLAB Matlab toolbox was used for visualization and topographic plots (Delorme and Makeig, 2004).”
BackgroundMethodAn open resource for transdiagnostic research in pediatric mental health and learning disorders
Alexander, L. M., Escalera, J., Ai, L., Andreotti, C., Febre, K., Mangone, A., Vega-Potler, N., Langer, N., Alexander, A., Kovacs, M., et al. (2017) · Scientific Data · doi:10.1038/sdata.2017.181 · Cited by 651
Subthalamic nucleus stimulation reverses mediofrontal influence over decision threshold
Cavanagh, J. F., Wiecki, T. V., Cohen, M. X., Figueroa, C. M., Samanta, J., Sherman, S. J., & Frank, M. J. (2011) · Nature Neuroscience · doi:10.1038/nn.2925 · Cited by 645
Autoreject: Automated artifact rejection for MEG and EEG data
Jas, M., Engemann, D. A., Bekhti, Y., Raimondo, F., & Gramfort, A. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.06.030 · Cited by 598
EEGLAB, SIFT, NFT, BCILAB, and ERICA: New Tools for Advanced EEG Processing
Delorme, A., Mullen, T., Kothe, C., Akalin Acar, Z., Bigdely-Shamlo, N., Vankov, A., & Makeig, S. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/130714 · Cited by 643
“Complex event-related experiments typically include a number of di ff erent types of events.”
BackgroundMethodSelf-citationWorking memory revived in older adults by synchronizing rhythmic brain circuits
Reinhart, R. M. G., & Nguyen, J. A. (2019) · Nature Neuroscience · doi:10.1038/s41593-019-0371-x · Cited by 639
CoSMoMVPA: Multi-Modal Multivariate Pattern Analysis of Neuroimaging Data in Matlab/GNU Octave
Oosterhof, N. N., Connolly, A. C., & Haxby, J. V. (2016) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2016.00027 · Cited by 658
“It can read and write the general fMRI NIFTI and GIFTI formats, and in addition read and write in the native data formats used by the AFNI (R. W. Cox, 1996), BrainVoyager (Goebel, Esposito, & Formisano, 2006), SPM (Friston et al., 1994), FieldTrip (Oostenveld et al., 2011) and EEGLAB (Delorme & Makeig, 2004) packages.”
MethodInfluentialReappraisal modulates the electrocortical response to unpleasant pictures
HAJCAK, G., & NIEUWENHUIS, S. (2006) · Cognitive, Affective, & Behavioral Neuroscience · doi:10.3758/cabn.6.4.291 · Cited by 615
“Scalp topography plots were created using EEGLAB (Delorme & Makeig, 2004).”
Theta lingua franca: A common mid‐frontal substrate for action monitoring processes
Cavanagh, J. F., Zambrano‐Vazquez, L., & Allen, J. J. B. (2012) · Psychophysiology · doi:10.1111/j.1469-8986.2011.01293.x · Cited by 651
“An infomax independent components analysis was run on each task for each subject using runica from the EEGLab toolbox ( Delorme & Makeig , 2004 ) .”
MethodRoach, B. J., & Mathalon, D. H. (2008) · Schizophrenia Bulletin · doi:10.1093/schbul/sbn093 · Cited by 602
“pendent waveforms from the scalp EEG data using independent component analysis, followed by assessment of MS coherence and/or phase coherence between independent components.(10) Because of the contamination of electrodes or sensors by volume-conducted signals, the absolute value of phase coherence between sites is pro…”
MethodUntangling cross-frequency coupling in neuroscience
Aru, J., Aru, J., Priesemann, V., Wibral, M., Lana, L., Pipa, G., Singer, W., & Vicente, R. (2015) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2014.08.002 · Cited by 608
Scalable tensor factorizations for incomplete data
Acar, E., Dunlavy, D. M., Kolda, T. G., & Mørup, M. (2011) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2010.08.004 · Cited by 602
“The 3-D head images were drawn using EEGLab [35].”
MethodMoment-to-moment brain signal variability: A next frontier in human brain mapping?
Garrett, D. D., Samanez-Larkin, G. R., MacDonald, S. W. S., Lindenberger, U., McIntosh, A. R., & Grady, C. L. (2013) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2013.02.015 · Cited by 585
Coregistration of eye movements and EEG in natural reading: Analyses and review.
Dimigen, O., Sommer, W., Hohlfeld, A., Jacobs, A. M., & Kliegl, R. (2011) · Journal of Experimental Psychology: General · doi:10.1037/a0023885 · Cited by 602
“We performed joint EM and EEG analyses in MATLAB (Mathworks, Natick, MA) using selected functions of the EEGLAB toolbox (Delorme & Makeig, 2004).”
MethodReward expectation modulates feedback-related negativity and EEG spectra
Cohen, M. X., Elger, C. E., & Ranganath, C. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.056 · Cited by 586
“Briefly, the procedure involves convolving the time domain signal with a complex sinusoidal wavelet with increasing cycles as frequencies increase (Delorme and Makeig, 2004).”
BackgroundMethodInfluentialOptimized multi-electrode stimulation increases focality and intensity at target
Dmochowski, J. P., Datta, A., Bikson, M., Su, Y., & Parra, L. C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046011 · Cited by 590
Holroyd, C. B., Pakzad‐Vaezi, K. L., & Krigolson, O. E. (2008) · Psychophysiology · doi:10.1111/j.1469-8986.2008.00668.x · Cited by 582
“For display purposes, the spatial factor loadings were plotted using custom Matlab scripts built on the open source EEGLAB toolbox (spherical spline interpolation; Delorme & Makeig, 2004; http://sccn.ucsd.edu/eeglab).”
MethodInfluentialReward Changes Salience in Human Vision via the Anterior Cingulate
Hickey, C., Chelazzi, L., & Theeuwes, J. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.1026-10.2010 · Cited by 606
“Independent component analysis (Bell and Sejnowski, 1995; Delorme and Makeig, 2004) was applied to the data and the results used for the rejection of trials tainted by eye movements (8 4% of trials per participant, mean SD) and correction of artifacts stemming from blinks and muscle activity.”
MethodVenkatraman, V., Dimoka, A., Pavlou, P. A., Vo, K., Hampton, W., Bollinger, B., Hershfield, H. E., Ishihara, M., & Winer, R. S. (2015) · Journal of Marketing Research · doi:10.1509/jmr.13.0593 · Cited by 549
“Artifacts (horizontal eye movement, vertical eye movement, eye blinks, and general discontinuities) were automatically detected and removed using ADJUST 1.1, an independent plug-in for EEGLAB (Mognon et al. 2011).”
MethodInfluentialDynamic hidden states underlying working-memory-guided behavior
Wolff, M. J., Jochim, J., Akyürek, E. G., & Stokes, M. G. (2017) · Nature Neuroscience · doi:10.1038/nn.4546 · Cited by 584
Sassenhagen, J., & Draschkow, D. (2019) · Psychophysiology · doi:10.1111/psyp.13335 · Cited by 545
Nasal Respiration Entrains Human Limbic Oscillations and Modulates Cognitive Function
Zelano, C., Jiang, H., Zhou, G., Arora, N., Schuele, S., Rosenow, J., & Gottfried, J. A. (2016) · The Journal of Neuroscience · doi:10.1523/jneurosci.2586-16.2016 · Cited by 599
Low-Frequency Cortical Entrainment to Speech Reflects Phoneme-Level Processing
Di Liberto, G. M., O’Sullivan, J. A., & Lalor, E. C. (2015) · Current Biology · doi:10.1016/j.cub.2015.08.030 · Cited by 578
Reactivation of latent working memories with transcranial magnetic stimulation
Rose, N. S., LaRocque, J. J., Riggall, A. C., Gosseries, O., Starrett, M. J., Meyering, E. E., & Postle, B. R. (2016) · Science · doi:10.1126/science.aah7011 · Cited by 573
Removal of FMRI environment artifacts from EEG data using optimal basis sets
Niazy, R. K., Beckmann, C. F., Iannetti, G. D., Brady, J. M., & Smith, S. M. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.06.067 · Cited by 567
“, MA, USA) as plug-ins for the EEGLAB Toolbox (Delorme and Makeig, 2004) and they can be downloaded for use under the General Public Licence (GPL-Free Software Foundation, Inc.”
MethodRecipes for the linear analysis of EEG
Parra, L. C., Spence, C. D., Gerson, A. D., & Sajda, P. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.05.032 · Cited by 569
“Summarizing, we find the following simple linear model which is an accurate representation of the electro-physics of EEG, x t ð Þ ¼ As t ð Þ þ n t ð Þ: ð4Þ 2 MATLAB Plug-ins for EEGLAB can be downloaded from http:// liinc.bme.columbia.edu/downloads.”
BackgroundMethodInfluentialCastellanos, N. P., & Makarov, V. A. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.05.033 · Cited by 569
Chang, C.-Y., Hsu, S.-H., Pion-Tonachini, L., & Jung, T.-P. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2930186 · Cited by 544
“ICA assumes EEG data, x, can be modeled as a linear mixture A of statistically independent sources, s, and learns an unmixing matrix, W , such that the independent components (IC) recover the original sources, y. x = As y = Wx ≈ s In this study, we employ extended Infomax ICA [37], which is available in the runica fun…”
MethodInfluentialTransfer Learning for Brain–Computer Interfaces: A Euclidean Space Data Alignment Approach
He, H., & Wu, D. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2913914 · Cited by 569
“Additionally, two classes (left hand and right hand) of motor imagery were selected and each class had 72 trials. The EEG signals from both datasets were preprocessed using the Matlab EEGLAB toolbox [9], following the guideline in [4]. First, a band-pass filter (8-30Hz) was applied to remove muscle artifacts, line-nois…”
MethodInfluentialDien, J. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.12.009 · Cited by 537
“It is recommended that the computer have a minimum of 2GB and preferably at least 4GB. EEGlab (Delorme & Makeig, 2004) and Robert Oostenveld's FieldTrip (http://www.ru.nl/neuroimaging/fieldtrip) will also need to be installed, the former for the ICA function and the channel coordinates function and…”
BackgroundGabard-Durnam, L. J., Mendez Leal, A. S., Wilkinson, C. L., & Levin, A. R. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00097 · Cited by 535
“HAPPE integrates Matlab-based (The Mathworks, Inc.) code with freely available academic software, including EEGLAB functions (Delorme and Makeig, 2004), to automatedly batch process resting-state and event-related EEG data from raw format to corrected signal prepared for analyses in the frequency…”
BackgroundMethodInfluentialMathewson, K. E., Lleras, A., Beck, D. M., Fabiani, M., Ro, T., & Gratton, G. (2011) · Frontiers in Psychology · doi:10.3389/fpsyg.2011.00099 · Cited by 503
How about taking a low‐cost, small, and wireless EEG for a walk?
Debener, S., Minow, F., Emkes, R., Gandras, K., & de Vos, M. (2012) · Psychophysiology · doi:10.1111/j.1469-8986.2012.01471.x · Cited by 540
A Benchmark Dataset for SSVEP-Based Brain–Computer Interfaces
Wang, Y., Chen, X., Gao, X., & Gao, S. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2627556 · Cited by 501
“The electrode file can be imported into EEGLAB [24] for topographic analysis using the topoplot() function.”
MethodWhitham, E. M., Pope, K. J., Fitzgibbon, S. P., Lewis, T., Clark, C. R., Loveless, S., Broberg, M., Wallace, A., DeLosAngeles, D., Lillie, P., et al. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.04.027 · Cited by 524
“In addition, time frequency plots of the un-averaged, unfiltered, data were generated (EEGLAB Toolbox (Delorme and Makeig, 2004)) to visualise evoked and induced gamma frequencies with FFT of 512 samples of data and 90% overlap of consecutive epochs to provide temporally smooth images.”
MethodIncreased EEG power and slowed dominant frequency in patients with neurogenic pain
Sarnthein, J., Stern, J., Aufenberg, C., Rousson, V., & Jeanmonod, D. (2006) · Brain · doi:10.1093/brain/awh631 · Cited by 484
“DatawereanalysedofflineusingMatlab(TheMathworks,Natick,MA) using EEGLAB (http://sccn.ucsd.edu/eeglab; Delorme and Makeig, 2004) and custom scripts.”
MethodPupillometry and P3 index the locus coeruleus-noradrenergic arousal function in humans
Murphy, P. R., Robertson, I. H., Balsters, J. H., & O'connell, R. G. (2011) · Psychophysiology · doi:10.1111/j.1469-8986.2011.01226.x · Cited by 519
“All further processing was carried out using a combination of in-house MATLAB scripting and EEGLAB (Delorme & Makeig, 2004).”
A Review on Machine Learning for EEG Signal Processing in Bioengineering
Hosseini, M.-P., Hosseini, A., & Ahi, K. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.2969915 · Cited by 468
“[22] Traditionally, Mohammad-Parsa Hosseini is with the Bioengineering Department, Santa Clara University, Santa Clara, CA 95053 USA and also with the AI Research, Silicon Valley, CA USA (e-mail: mhosseini@scu.edu).”
BackgroundPsycholinguistics Electrified II (1994–2005)
Kutas, M., Van Petten, C. K., & Kluender, R. (2006) · Handbook of Psycholinguistics · doi:10.1016/b978-012369374-7/50018-3 · Cited by 500
EEG-BIDS, an extension to the brain imaging data structure for electroencephalography
Pernet, C. R., Appelhoff, S., Gorgolewski, K. J., Flandin, G., Phillips, C., Delorme, A., & Oostenveld, R. (2019) · Scientific Data · doi:10.1038/s41597-019-0104-8 · Cited by 443
The Speed of Alpha-Band Oscillations Predicts the Temporal Resolution of Visual Perception
Samaha, J., & Postle, B. R. (2015) · Current Biology · doi:10.1016/j.cub.2015.10.007 · Cited by 465
“Data were down sampled to 250 Hz offline using the EEGLAB toolbox [26] in MATLAB.”
MethodFrontal theta links prediction errors to behavioral adaptation in reinforcement learning
Cavanagh, J. F., Frank, M. J., Klein, T. J., & Allen, J. J. B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.11.080 · Cited by 469
“Data were then epoched (−1500 ms to 1500 ms) around each feedback onset in the training phase, these epochs were then cleaned of eyeblink and muscle artifacts using independent components analysis from the EEGLab toolbox (Delorme and Makeig, 2004).”
The effects of electrode impedance on data quality and statistical significance in ERP recordings
Kappenman, E. S., & Luck, S. J. (2010) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01009.x · Cited by 447
“All simulations were conducted inMatlab (The Mathworks, Inc., Natick, MA) using the EEGLAB Toolbox (Delorme & Makeig, 2004) and custom routines.”
MethodElectrocortical activity is coupled to gait cycle phase during treadmill walking
Gwin, J. T., Gramann, K., Makeig, S., & Ferris, D. P. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.08.066 · Cited by 479
“DIPFIT functions within EEGLAB (Oostenveld and Oostendorp, 2002) computed an equivalent current dipole model that best explained the scalp topography of each IC using a boundary element head model based on the Montreal Neurological Institute (MNI) template (the average of 152 MRI scans from healthy subjects, available…”
InfluentialSelf-citationRemoval of Movement Artifact From High-Density EEG Recorded During Walking and Running
Gwin, J. T., Gramann, K., Makeig, S., & Ferris, D. P. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00105.2010 · Cited by 481
“All procedures were approved by the University of Michigan Internal Review Board and complied with the standards defined in the Declaration of Helsinki.”
MethodInfluentialSelf-citationOld brains come uncoupled in sleep: slow wave-spindle synchrony, brain atrophy, and forgetting
Helfrich, R. F., Mander, B. A., Jagust, W. J., Knight, R. T., & Walker, M. P. (2018) · Neuron · doi:10.1016/j.neuron.2017.11.020 · Cited by 497
Mental training enhances attentional stability: Neural and behavioral evidence
Lutz, A., Slagter, H. A., Rawlings, N. B., Francis, A. D., Greischar, L. L., & Davidson, R. J. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.1614-09.2009 · Cited by 489
“EEGLAB (Delorme and Makeig, 2004) and Matlab (MathWorks) were used for offline EEG data processing.”
MethodTriggering sleep slow waves by transcranial magnetic stimulation
Massimini, M., Ferrarelli, F., Esser, S. K., Riedner, B. A., Huber, R., Murphy, M., Peterson, M. J., & Tononi, G. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0702495104 · Cited by 489
EEG-Based Spatio–Temporal Convolutional Neural Network for Driver Fatigue Evaluation
Gao, Z., Wang, X., Yang, Y., Mu, C., Cai, Q., Dang, W., & Zuo, S. (2019) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2018.2886414 · Cited by 482
“Raw EEG signals were preprocessed with EEGLAB toolbox [41].”
Sawaki, R., & Luck, S. J. (2010) · Attention, Perception, & Psychophysics · doi:10.3758/app.72.6.1455 · Cited by 487
“All analyses after data acquisition were conducted using ERPLAB Toolbox (www.erpinfo.org/erplab/) and EEGLAB Toolbox (Delorme & Makeig, 2004; http://sccn.ucsd.edu/eeglab/), which are freely available, open source, MATLAB-based packages for EEG/ ERP data analysis.”
MethodScheeringa, R., Fries, P., Petersson, K.-M., Oostenveld, R., Grothe, I., Norris, D. G., Hagoort, P., & Bastiaansen, M. C. M. (2011) · Neuron · doi:10.1016/j.neuron.2010.11.044 · Cited by 446
Methods for artifact detection and removal from scalp EEG: A review
Islam, M. K., Rastegarnia, A., & Yang, Z. (2016) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2016.07.002 · Cited by 457
Simon, N., Käthner, I., Ruf, C. A., Pasqualotto, E., Kübler, A., & Halder, S. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.01039 · Cited by 478
“The EEG data was analyzed with Matlab (version R2012b) in combination with the EEGLab toolbox (version 10.2.2.4b; Delorme and Makeig, 2004).”
MethodInfluentialNeural Mechanisms of Sustained Attention Are Rhythmic
Helfrich, R. F., Fiebelkorn, I. C., Szczepanski, S. M., Lin, J. J., Parvizi, J., Knight, R. T., & Kastner, S. (2018) · Neuron · doi:10.1016/j.neuron.2018.07.032 · Cited by 447
Choosing MUSE: Validation of a Low-Cost, Portable EEG System for ERP Research
Krigolson, O. E., Williams, C. C., Norton, A., Hassall, C. D., & Colino, F. L. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00109 · Cited by 412
“Following segmentation, independent component analysis was used to correct ocular artifacts (Delorme and Makeig, 2004; Luck, 2014).”
Glioblastoma remodelling of human neural circuits decreases survival
Krishna, S., Choudhury, A., Keough, M. B., Seo, K., Ni, L., Kakaizada, S., Lee, A., Aabedi, A., Popova, G., Lipkin, B., et al. (2023) · Nature · doi:10.1038/s41586-023-06036-1 · Cited by 418
Clinical utility and prospective of TMS–EEG
Tremblay, S., Rogasch, N. C., Premoli, I., Blumberger, D. M., Casarotto, S., Chen, R., Di Lazzaro, V., Farzan, F., Ferrarelli, F., Fitzgerald, P. B., et al. (2019) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.01.001 · Cited by 472
“, 2011) and EEGLAB (Delorme and Makeig, 2004), but also combine their use with custom-written scripts on the Matlab platform.”
Neuling, T., Rach, S., & Herrmann, C. S. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00161 · Cited by 443
“For statistical analysis, SPSS 20.0 (IBM Corp, Armonk, NY, USA) was used.”
MethodInfluential(2013) · Elsevier eBooks · doi:10.1016/c2010-0-65035-8 · Cited by 465
Recovery of cortical effective connectivity and recovery of consciousness in vegetative patients
Rosanova, M., Gosseries, O., Casarotto, S., Boly, M., Casali, A. G., Bruno, M.-A., Mariotti, M., Boveroux, P., Tononi, G., Laureys, S., et al. (2012) · Brain · doi:10.1093/brain/awr340 · Cited by 457
“1), a bootstrap method (Delorme and Makeig, 2004; Lv et al., 2007; McCubbin et al., 2008), which does not assume normal distribution of the observations, was applied by shuffling the time samples of GMFP prestimulus activity (from 300 to 50 ms) at the single-trial level and by calculating 500…”
Internal and External Influences on the Rate of Sensory Evidence Accumulation in the Human Brain
Kelly, S. P., & O'Connell, R. G. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.3355-13.2013 · Cited by 455
“Data were analyzed using custom scripts in MATLAB (MathWorks), drawing on EEGLAB routines for reading data files and spherical spline interpolation of noisy channels (Delorme and Makeig, 2004).”
MethodHauser, T. U., Iannaccone, R., Stämpfli, P., Drechsler, R., Brandeis, D., Walitza, S., & Brem, S. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.08.028 · Cited by 428
“, Natick, USA) and EEGLAB-toolbox (10.2.2.4; Delorme and Makeig, 2004).”
MethodInfluential
Metadata
- Authors
- Delorme, A., & Makeig, S.
- Affiliations
- University of California San Diego (US)
- ORCID
- Makeig, Scott
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2004-03
- Volume
- 134
- Issue
- 1
- Pages
- 9-21
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2128495200
- Cited by
- 24,371
- References
- 39
- Citations by year
- 2026: 1965 · 2025: 2472 · 2024: 2191 · 2023: 2114 · 2022: 1984 · 2021: 1999 · 2020: 1784 · 2019: 1662 · 2018: 1378 · 2017: 1260 · 2016: 1022 · 2015: 921 · 2014: 766 · 2013: 683 · 2012: 515
- FWCI
- 62.72
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Computer Science › Signal Processing › Blind Source Separation Techniques
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Keywords
- EEGLAB, single-trial EEG, independent component analysis, event-related potentials, EEG preprocessing, artifact rejection, time-frequency decomposition, cross-coherence, bootstrapping, dipole modeling, open source software, MATLAB toolbox
- MeSH terms
- Computer Simulation, Electroencephalography, Evoked Potentials, Software
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.