The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Electrodes for high-definition transcutaneous DC stimulation for applications in drug delivery and electrotherapy, including tDCS
Open accessAbstract
Transcutaneous electrical stimulation is applied in a range of biomedical applications including Transcranial Direct Current Stimulation (tDCS). tDCS is a non-invasive procedure where a weak direct current (<2 mA) is applied across the scalp to modulate brain function. High-Definition tDCS (HD-tDCS) is a technique used to increase the spatial focality of tDCS by passing current across the scalp using <12 mm diameter electrodes. The purpose of this study was to design and optimize “high-definition” electrode-gel parameters for electrode durability, skin safety, and subjective pain. Anode and cathode electrode potential, temperature, pH, and subjective sensation over time were assessed during application of 2 mA direct current, for up to 22 minutes on agar gel or subject forearms. A selection of 5 types of solid-conductors (Ag pellet, Ag/AgCl pellet, Rubber pellet, Ag/AgCl ring, and Ag/AgCl disc) and 7 conductive gels (Signa, Spectra, Tensive, Redux, BioGel, Lectron, and CCNY-4) were investigated. The Ag/AgCl ring in combination with CCNY-4 gel resulted in the most favorable outcomes. Under anode stimulations, electrode potential and temperature rises were generally observed in all electrode-gel combinations except for Ag/AgCl ring and disc electrodes. pH remained constant for all solid-conductors except for both Ag and Rubber pellet electrodes with Signa and CCNY-4 gels. Sensation ratings were independent of stimulation polarity. Ag/AgCl ring electrodes were found to be the most comfortable followed by Ag, Rubber, and Ag/AgCl pellet electrodes across all gels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcranial direct current stimulation: State of the art 2008
Nitsche, M. A., Cohen, L. G., Wassermann, E. M., Priori, A., Lang, N., Antal, A., Paulus, W., Hummel, F., Boggio, P. S., Fregni, F., et al. (2008) · Brain Stimulation · doi:10.1016/j.brs.2008.06.004 · Cited by 3,057
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Self-citationDatta, A., Bansal, V., Diaz, J., Patel, J., Reato, D., & Bikson, M. (2009) · Brain Stimulation · doi:10.1016/j.brs.2009.03.005 · Cited by 1,290
Self-citationSafety aspects of transcranial direct current stimulation concerning healthy subjects and patients
Poreisz, C., Boros, K., Antal, A., & Paulus, W. (2007) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2007.01.004 · Cited by 1,099
Shaping the Effects of Transcranial Direct Current Stimulation of the Human Motor Cortex
Nitsche, M. A., Doemkes, S., Karaköse, T., Antal, A., Liebetanz, D., Lang, N., Tergau, F., & Paulus, W. (2007) · Journal of Neurophysiology · doi:10.1152/jn.01312.2006 · Cited by 738
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708
Safety criteria for transcranial direct current stimulation (tDCS) in humans
Nitsche, M. A., Liebetanz, D., Lang, N., Antal, A., Tergau, F., & Paulus, W. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00235-9 · Cited by 697
Electroporation of mammalian skin: a mechanism to enhance transdermal drug delivery.
Prausnitz, M. R., Bose, V. G., Langer, R., & Weaver, J. C. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.22.10504 · Cited by 640
Safety limits of cathodal transcranial direct current stimulation in rats
Liebetanz, D., Koch, R., Mayenfels, S., König, F., Paulus, W., & Nitsche, M. A. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.01.022 · Cited by 401
Evaluation of commercially available electrodes and gels for recording of slow EEG potentials
Tallgren, P., Vanhatalo, S., Kaila, K., & Voipio, J. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.10.001 · Cited by 344
Transcranial current stimulation focality using disc and ring electrode configurations: FEM analysis
Datta, A., Elwassif, M., Battaglia, F., & Bikson, M. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/2/007 · Cited by 320
Self-citationEstablishing safety limits for transcranial direct current stimulation
Bikson, M., Datta, A., & Elwassif, M. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.03.018 · Cited by 298
Self-citationConsiderations for safety in the use of extracranial stimulation for motor evoked potentials
Agnew, W. F., & McCreery, D. B. (1987) · Neurosurgery · doi:10.1097/00006123-198701000-00030 · Cited by 265
The effects of electric current applied to skin: A review for transdermal drug delivery
Prausnitz, M. R. (1996) · Advanced Drug Delivery Reviews · doi:10.1016/0169-409x(95)00081-h · Cited by 213
Evidence for axonal membrane hyperpolarization in multifocal motor neuropathy with conduction block
Kiernan, M. C., Guglielmi, J.-M., Kaji, R., Murray, N. M. F., & Bostock, H. (2002) · Brain · doi:10.1093/brain/awf041 · Cited by 186
Miranda, P. C., Faria, P., & Hallett, M. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.03.023 · Cited by 164
Histological Evaluation of Neural Damage from Electrical Stimulation
Yuen, T. G. H., Agnew, W. F., Bullara, L. A., Jacques, S., & McCreery, D. B. (1981) · Neurosurgery · doi:10.1097/00006123-198109000-00013 · Cited by 160
Dundas, J. E., Thickbroom, G. W., & Mastaglia, F. L. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.01.010 · Cited by 159
Skin biological issues in electrically enhanced transdermal delivery
Ledger, P. W. (1992) · Advanced Drug Delivery Reviews · doi:10.1016/0169-409x(92)90027-n · Cited by 159
Skin lesions after treatment with transcranial direct current stimulation (tDCS)
Palm, U., Keeser, D., Schiller, C., Fintescu, Z., Reisinger, E., Padberg, F., & Nitsche, M. A. (2008) · Brain stimulation · doi:10.1016/j.brs.2008.04.003 · Cited by 157
Datta, A., Elwassif, M., & Bikson, M. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333673 · Cited by 74
Self-citationBikson, M., Bulow, P., Stiller, J. W., Datta, A., Battaglia, F., Karnup, S. V., & Postolache, T. T. (2008) · Current Treatment Options in Neurology · doi:10.1007/s11940-008-0040-y · Cited by 66
Self-citationGilad, O., Lior Horesh, C., & Holder, D. S. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0209-7 · Cited by 65
Skin Microcirculation during Tapwater Iontophoresis in Humans: Cathode Stimulates More Than Anode
Berliner, M. N. (1997) · Microvascular Research · doi:10.1006/mvre.1997.2025 · Cited by 57
Pain Sensations Associated with Electrocutaneous Stimulation
Mason, J. L., & Mackay, N. A. M. (1976) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1976.324652 · Cited by 57
Pliquett, U. F., Martin, G. T., & Weaver, J. C. (2002) · Bioelectrochemistry · doi:10.1016/s1567-5394(01)00177-3 · Cited by 50
Effect of Electrode Size, Shape, and Placement During Electrical Stimulation
Forrester, B. J., & PETROFSKY, J. S. (2004) · Cited by 47
Feeling the heat: the electrode–skin interface during DCS
Lagopoulos, J., & Degabriele, R. (2008) · Acta Neuropsychiatrica · doi:10.1111/j.1601-5215.2008.00274.x · Cited by 34
Distributed Equivalent-Circuit Models for Circular Dispersive Electrodes
Wiley, J. D., & Webster, J. G. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324911 · Cited by 28
Safety and ECT Stimulus Electrodes: I. Heat Liberation at the Electrode-Skin Interface.
Swartz, C. M. (1989) · PubMed · Cited by 13
Cited by
Brunoni, A. R., Nitsche, M. A., Bolognini, N., Bikson, M., Wagner, T., Merabet, L., Edwards, D. J., Valero-Cabre, A., Rotenberg, A., Pascual-Leone, A., et al. (2012) · Brain stimulation · doi:10.1016/j.brs.2011.03.002 · Cited by 1,445
Self-citationA technical guide to tDCS, and related non-invasive brain stimulation tools
Woods, A. J., Antal, A., Bikson, M., Boggio, P. S., Brunoni, A. R., Celnik, P., Cohen, L. G., Fregni, F., Herrmann, C. S., Kappenman, E. S., et al. (2016) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.11.012 · Cited by 1,439
Self-citationSafety of Transcranial Direct Current Stimulation: Evidence Based Update 2016
Bikson, M., Grossman, P., Thomas, C., Zannou, A. L., Jiang, J., Adnan, T., Mourdoukoutas, A. P., Kronberg, G., Truong, D., Boggio, P., et al. (2016) · Brain Stimulation · doi:10.1016/j.brs.2016.06.004 · Cited by 1,396
Self-citationAntal, A., Alekseichuk, I., Bikson, M., Brockmöller, J., Brunoni, A. R., Chen, R., Cohen, L. G., Dowthwaite, G., Ellrich, J., Flöel, A., et al. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.06.001 · Cited by 1,301
Self-citationKuo, H.-I., Bikson, M., Datta, A., Minhas, P., Paulus, W., Kuo, M.-F., & Nitsche, M. A. (2013) · Brain Stimulation · doi:10.1016/j.brs.2012.09.010 · Cited by 695
Self-citation
Metadata
- Authors
- Minhas, P., Bansal, V., Patel, J., Ho, J. S., Diaz, J., Datta, A., & Bikson, M.
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2010-07
- Volume
- 190
- Issue
- 2
- Pages
- 188-197
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2164138781
- Cited by
- 267
- References
- 30
- FWCI
- 8.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.