The DOI matches its Crossref record.
Accelerated aging for testing polymeric biomaterials and medical devices
Abstract
Elevated temperature is frequently used to accelerate the aging process in polymers that are associated with medical devices and other applications. A common approach is to assume that the rate of aging is increased by a factor of 2(DeltaT/10), where DeltaT is the temperature increase. This result is a mathematical expression of the empirical observation that increasing the temperature by about 10 degrees C roughly doubles the rate of many polymer reactions. It is equivalent to assuming that the aging process is a first order chemical reaction with an activation energy of 10R/log(e)2, where R is the universal gas constant. A better approach would be to determine the activation energy for the process being considered but this is not always practicable. The simple approach does not depend on the temperature increase, provided that it is not so great that it initiates any physical or chemical process that is unlikely to be involved in normal aging. If a temperature increment theta were to increase a given polymer reaction rate n times, then an elevated temperature would increase the rate of aging by a factor of n(DeltaT/theta).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Degradation mechanisms of polycaprolactone in the context of chemistry, geometry and environment
Bartnikowski, M., Dargaville, T. R., Ivanovski, S., & Hutmacher, D. W. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2019.05.004 · Cited by 769
Degradation and stabilization of polyurethane elastomers
Xie, F., Zhang, T., Bryant, P., Kurusingal, V., Colwell, J. M., & Laycock, B. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.12.003 · Cited by 722
In Vitro and In Vivo Evaluation of PEDOT Microelectrodes for Neural Stimulation and Recording
Venkatraman, S., Hendricks, J., King, Z. A., Sereno, A. J., Richardson-Burns, S., Martin, D., & Carmena, J. M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2109399 · Cited by 319
“These methods were adapted from [23], ASTM Standard F2003-02(2008) [24] and ASTM Standard F1980-07 [25].”
MethodBoehler, C., Carli, S., Fadiga, L., Stieglitz, T., & Asplund, M. (2020) · Nature Protocols · doi:10.1038/s41596-020-0389-2 · Cited by 308
Chronic in vivo stability assessment of carbon fiber microelectrode arrays
Patel, P. R., Zhang, H., Robbins, M. T., Nofar, J. B., Marshall, S. P., Kobylarek, M. J., Kozai, T. D. Y., Kotov, N. A., & Chestek, C. A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066002 · Cited by 204
“According to works by Green et al [45] and Hukins et al [46], equation (1) can be used to determine the aging time that the fibers have undergone: = ´ -t t Q10 , 1T T37 37 10 ( )( ) where t37 is the simulated aging time at 37 °C, tT is the amount of real time that the samples have been kept at the elevated temperature…”
MethodDesign and validation of a foldable and photovoltaic wide-field epiretinal prosthesis
Ferlauto, L., Airaghi Leccardi, M. J. I., Chenais, N. A. L., Gilliéron, S. C. A., Vagni, P., Bevilacqua, M., Wolfensberger, T. J., Sivula, K., & Ghezzi, D. (2018) · Nature Communications · doi:10.1038/s41467-018-03386-7 · Cited by 183
A low-power stretchable neuromorphic nerve with proprioceptive feedback
Lee, Y., Liu, Y., Seo, D.-G., Oh, J. Y., Kim, Y., Li, J., Kang, J., Kim, J., Mun, J., Foudeh, A. M., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00918-x · Cited by 177
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Xie, X., Rieth, L., Williams, L., Negi, S., Bhandari, R., Caldwell, R., Sharma, R., Tathireddy, P., & Solzbacher, F. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026016 · Cited by 137
The Future of Neuroimplantable Devices: A Materials Science and Regulatory Perspective
Obidin, N., Tasnim, F., & Dagdeviren, C. (2020) · Advanced Materials · doi:10.1002/adma.201901482 · Cited by 126
Spatially selective activation of the visual cortex via intraneural stimulation of the optic nerve
Gaillet, V., Cutrone, A., Artoni, F., Vagni, P., Mega Pratiwi, A., Romero, S. A., Lipucci Di Paola, D., Micera, S., & Ghezzi, D. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0446-8 · Cited by 73
Polymeric C-shaped cuff electrode for recording of peripheral nerve signal
Xue, N., Sun, T., Tsang, W. M., Delgado-Martinez, I., Lee, S.-H., Sheshadri, S., Xiang, Z., Merugu, S., Gu, Y., Yen, S.-C., et al. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.01.006 · Cited by 48
Schander, A., Gancz, J., Tintelott, M., & Lang, W. (2021) · Micromachines · doi:10.3390/mi12111279 · Cited by 28
“This elevated temperature accelerates the diffusion of saline into the polymer layers and speeds up the degradation process [16].”
BackgroundHigh-Density, Actively Multiplexed µECoG Array on Reinforced Silicone Substrate
Rachinskiy, I., Wong, L., Chiang, C.-H., Wang, C., Trumpis, M., Ogren, J. I., Hu, Z., McLaughlin, B., & Viventi, J. (2022) · Frontiers in Nanotechnology · doi:10.3389/fnano.2022.837328 · Cited by 14
Metadata
- Authors
- Hukins, D. W. L., Mahomed, A., & Kukureka, S. N.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2008-08-09
- Volume
- 30
- Issue
- 10
- Pages
- 1270-1274
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2054968793
- Cited by
- 247
- References
- 0
- FWCI
- 1.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.