The DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
Spatio-temporal point-spread function of fMRI signal in human gray matter at 7 Tesla
Open accessAbstract
This study investigated the spatio-temporal properties of blood-oxygenation level-dependent (BOLD) functional MRI (fMRI) signals in gray matter, excluding the confounding, inaccurate contributions of large blood vessels. We quantified the spatial specificity of the BOLD response, and we investigated whether this specificity varies as a function of time from stimulus onset. fMRI was performed at 7 Tesla (T), where mapping signals of parenchymal origin are easily detected. Two abutting visual stimuli were adjusted to elicit responses centered on a flat gray matter region in V1. fMRI signals were sampled at high-resolution orthogonal to the retinotopic boundary between the representations of the stimuli. Signals from macro-vessels were masked out. Principal component analysis revealed that the first component in space accounted for 96.2+/-1.6% of the variance over time. The spatial profile of this time-invariant response was fitted with a model consisting of the convolution of a step function and a Gaussian point-spread-function (PSF). The mean full-width at half-maximal-height of the fitted PSF was 2.34+/-0.20 mm. Based on simulations of confounding effects, we estimate that BOLD PSF in human gray matter is smaller than 2 mm. A time-point to time-point analysis revealed that the PSF obtained during the 3rd (1.52 mm) and 4th (1.99 mm) seconds of stimulation were narrower than the mean PSF obtained from the 5th second on (2.42+/-0.15 mm). The position of the edge of the responding region was offset (1.72+/-0.07 mm) from the boundary of the stimulated region, indicating a spatial non-linearity. Simulations showed that the effective contrast between active and non-active columns is reduced 25-fold when imaged using a PSF whose width is equal to the cycle of the imaged columnar organization. Thus, the PSF of the hyper-oxygenated BOLD response in human gray matter is narrower than that reported at 1.5 T, where macro-vessels dominate the mapping signals. The initial phase of this response is more spatially specific than later phases. Data acquisition methods that suppress macro-vascular signals should increase the spatial specificity of BOLD fMRI. The choice of optimal stimulus duration represents a trade-off between the spatial specificity and the overhead associated with short stimulus duration.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“At the low field strengths suitable for scanning children and adolescents (<7 T), the PSF in a region of cortex is thought to be largely determined by proximity to local blood vessels, rather than by local grey matter density, horizontal connections, synapses and so on (Sirotin et al., 2009; Shmuel et al., 2007).”
From The social brain in adolescence: evidence from functional magnetic resonance imaging and behavioural studies (2011) · cites this paper as Shmuel et al., 2007
Citations
Cites
Receptive fields, binocular interaction and functional architecture in the cat’s visual cortex
Hubel, D. H., & Wiesel, T. N. (1962) · The Journal of Physiology · doi:10.1113/jphysiol.1962.sp006837 · Cited by 13,680
Jenkinson, M., Bannister, P., Brady, M., & Smith, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1132 · Cited by 11,888
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Linear Systems Analysis of Functional Magnetic Resonance Imaging in Human V1
Boynton, G., Engel, S., Glover, G., & Heeger, D. (1996) · Journal of Neuroscience · doi:10.1523/jneurosci.16-13-04207.1996 · Cited by 2,522
Fox, P. T., & Raichle, M. E. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.4.1140 · Cited by 2,056
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Normalization of cell responses in cat striate cortex
Heeger, D. J. (1992) · Visual Neuroscience · doi:10.1017/s0952523800009640 · Cited by 1,835
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Processing strategies for time‐course data sets in functional mri of the human brain
Bandettini, P. A., Jesmanowicz, A., Wong, E. C., & Hyde, J. S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300204 · Cited by 1,762
Retinotopic organization in human visual cortex and the spatial precision of functional MRI
Engel, S. A. (1997) · Cerebral Cortex · doi:10.1093/cercor/7.2.181 · Cited by 1,606
Deconvolution of Impulse Response in Event-Related BOLD fMRI1
Glover, G. H. (1999) · NeuroImage · doi:10.1006/nimg.1998.0419 · Cited by 1,411
Malonek, D., & Grinvald, A. (1996) · Science · doi:10.1126/science.272.5261.551 · Cited by 1,109
Grinvald, A., Lieke, E. E., Rd, F., & Hildesheim, R. (1994) · Journal of Neuroscience · doi:10.1523/jneurosci.14-05-02545.1994 · Cited by 632
Ogawa, S., & Lee, T. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160103 · Cited by 565
Linear coupling between cerebral blood flow and oxygen consumption in activated human cortex
Hoge, R. D., Atkinson, J., Gill, B., Crelier, G. R., Marrett, S., & Pike, G. B. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.16.9403 · Cited by 564
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · Wiley eBooks · doi:10.1002/9781118633953 · Cited by 545
Functional anatomy of macaque striate cortex. II. Retinotopic organization
Tootell, R. B. H., Switkes, E., Silverman, M. S., & Hamilton, S. (1988) · Journal of Neuroscience · doi:10.1523/jneurosci.08-05-01531.1988 · Cited by 511
Functional anatomy of macaque striate cortex. III. Color
Tootell, R. B. H., Silverman, M. S., Hamilton, S., Valois, R. L. D., & Switkes, E. (1988) · Journal of Neuroscience · doi:10.1523/jneurosci.08-05-01569.1988 · Cited by 472
Imaging brain function in humans at 7 Tesla
Yacoub, E., Shmuel, A., Pfeuffer, J., Van De Moortele, P., Adriany, G., Andersen, P., Vaughan, J. T., Merkle, H., Ugurbil, K., & Hu, X. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1080 · Cited by 448
Self-citationMenon, R. S., Ogawa, S., Hu, X. P., Strupp, J., Anderson, P., & Uǧurbil, K. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330323 · Cited by 421
Menon, R. S., Ogawa, S., Tank, D. W., & Uǧurbil, K. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300317 · Cited by 412
Lai, S., Hopkins, A. L., Haacke, E. M., Li, D., Wasserman, B. A., Buckley, P., Friedman, L., Meltzer, H., Hedera, P., & Friedland, R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300318 · Cited by 390
Human Ocular Dominance Columns as Revealed by High-Field Functional Magnetic Resonance Imaging
Cheng, K., Waggoner, R. A., & Tanaka, K. (2001) · Neuron · doi:10.1016/s0896-6273(01)00477-9 · Cited by 383
Turner, R. (2002) · NeuroImage · doi:10.1006/nimg.2002.1082 · Cited by 365
Duong, T. Q., Yacoub, E. S., Adriany, G., Hu, X. P., Uǧurbil, K., & Kim, S. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10472 · Cited by 361
Self-citationSingle-Neuron Activity and Tissue Oxygenation in the Cerebral Cortex
Thompson, J. K., Peterson, M. R., & Freeman, R. D. (2003) · Science · doi:10.1126/science.1079220 · Cited by 358
Localized cerebral blood flow response at submillimeter columnar resolution
Duong, T. Q., Kim, D., Uǧurbil, K., & Kim, S. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.191101098 · Cited by 342
Brain or veinoxygenation or flow? On signal physiology in functional MRI of human brain activation
Frahm, J., Merboldt, K., Hänicke, W., Kleinschmidt, A. K., & Boecker, H. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070108 · Cited by 341
Lee, A. T.-J., Glover, G. H., & Meyer, C. H. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330602 · Cited by 321
Spin‐echo fMRI in humans using high spatial resolutions and high magnetic fields
Yacoub, E. S., Duong, T. Q., de Moortele, P. V., Lindquist, M. A., Adriany, G., Kim, S., Uǧurbil, K., & Hu, X. P. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10433 · Cited by 308
Self-citationOcular Dominance in Human V1 Demonstrated by Functional Magnetic Resonance Imaging
Menon, R. S., Ogawa, S., Strupp, J., & Uǧurbil, K. (1997) · Journal of Neurophysiology · doi:10.1152/jn.1997.77.5.2780 · Cited by 293
Zhao, F., Wang, P., Hendrich, K. S., Uǧurbil, K., & Kim, S. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.11.013 · Cited by 266
Laminar specificity of functional MRI onset times during somatosensory stimulation in rat
Silva, A. C., & Koretsky, A. P. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.222561899 · Cited by 262
Evaluation of the early response in fMRI in individual subjects using short stimulus duration
Hu, X. P., Le, T. H., & Uǧurbil, K. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370612 · Cited by 255
High‐resolution BOLD venographic imaging: a window into brain function
Reichenbach, J. R., & Haacke, E. M. (2001) · NMR in Biomedicine · doi:10.1002/nbm.722 · Cited by 248
Potential pitfalls of functional MRI using conventional gradient‐recalled echo techniques
Kim, S., Hendrich, K. S., Hu, X. P., Merkle, H., & Uǧurbil, K. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070111 · Cited by 224
Coupling of the cortical hemodynamic response to cortical and thalamic neuronal activity
Devor, A., Ulbert, I., Dunn, A. K., Narayanan, S. N., Jones, S. R., Andermann, M. L., Boas, D. A., & Dale, A. M. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0407789102 · Cited by 222
Pfeuffer, J., de Moortele, P. V., Uǧurbil, K., Hu, X. P., & Glover, G. H. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10065 · Cited by 216
Diffusion weighted fMRI at 1.5 T
Song, A. W., Wong, E. C., Tan, S. G., & Hyde, J. S. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350204 · Cited by 208
How accurate is magnetic resonance imaging of brain function?
Uǧurbil, K., Toth, L. J., & Kim, D. (2003) · Trends in Neurosciences · doi:10.1016/s0166-2236(02)00039-5 · Cited by 198
Signal and noise characteristics of Hahn SE and GE BOLD fMRI at 7 T in humans
Yacoub, E. S., de Moortele, P. V., Shmuel, A., & Uǧurbil, K. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.09.002 · Cited by 197
Self-citationWater diffusion, T2, and compartmentation in frog sciatic nerve
Peled, S., Cory, D. G., Raymond, S. A., Kirschner, D. A., & Jolesz, F. A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5 · Cited by 193
Quantifying the spatial resolution of the gradient echo and spin echo BOLD response at 3 Tesla
Parkes, L. M., Schwarzbach, J. V., Bouts, A. A., Deckers, R., Pullens, P., Kerskens, C., & Norris, D. G. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20712 · Cited by 187
Disbrow, E. A., Slutsky, D. A., Roberts, T. P. L., & Krubitzer, L. A. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.170205497 · Cited by 174
Haacke, E. M., Hopkins, A. L., Lai, S., Buckley, P. F., Friedman, L., Meltzer, H. Y., Hedera, P., Friedland, R. P., Klein, S. K., Thompson, L. A., et al. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070109 · Cited by 166
Brief visual stimulation allows mapping of ocular dominance in visual cortex using fMRI
Goodyear, B. G., & Menon, R. S. (2001) · Human Brain Mapping · doi:10.1002/hbm.1053 · Cited by 142
Cortical depth‐dependent gradient‐echo and spin‐echo BOLD fMRI at 9.4T
Zhao, F., Wang, P., & Kim, S. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10720 · Cited by 128
Arrangement of Ocular Dominance Columns in Human Visual Cortex
Horton, J. C. (1990) · Archives of Ophthalmology · doi:10.1001/archopht.1990.01070090127054 · Cited by 125
Perfusion‐based high‐resolution functional imaging in the human brain at 7 Tesla
Pfeuffer, J., Adriany, G., Shmuel, A., Yacoub, E. S., de Moortele, P. V., Hu, X. P., & Uǧurbil, K. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10154 · Cited by 125
Self-citationInvestigation of the initial dip in fMRI at 7 Tesla
Yacoub, E. S., Shmuel, A., Pfeuffer, J., de Moortele, P. V., Adriany, G., Uǧurbil, K., & Hu, X. P. (2001) · NMR in Biomedicine · doi:10.1002/nbm.715 · Cited by 121
Self-citationA multicenter measurement of magnetization transfer ratio in normal white matter
Berry, I., Barker, G. J., Barkhof, F., Campi, A., Dousset, V., Franconi, J., Gass, A., Schreiber, W., Miller, D. H., & Tofts, P. S. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199903)9:3 · Cited by 120
Single‐shot halfk‐space high‐resolution gradient‐recalled EPI for fMRI at 3 tesla
Jesmanowicz, A., Bandettini, P. A., & Hyde, J. S. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400517 · Cited by 96
Parametric reverse correlation reveals spatial linearity of retinotopic human V1 BOLD response
Hansen, K. A., David, S. V., & Gallant, J. L. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.05.012 · Cited by 87
Non-invasive visualization of cortical columns by fMRI
Grinvald, A., Slovin, H., & Vanzetta, I. (2000) · Nature Neuroscience · doi:10.1038/72045 · Cited by 77
Quantifying the intra‐ and extravascular contributions to spin‐echo fMRI at 3 T
Jochimsen, T. H., Norris, D. G., Mildner, T., & Möller, H. E. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20221 · Cited by 71
Flagged first, then by citations
Research works printed but not linked: 1
- Duvernoy, 1981, Vascularization of the human cerebral-cortex, Acta Anatomica, 111, 36
Cited by
Sorted by citations
The WU-Minn Human Connectome Project: An overview
Van Essen, D. C., Smith, S. M., Barch, D. M., Behrens, T. E. J., Yacoub, E., & Ugurbil, K. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.041 · Cited by 5,651
Self-citationThe minimal preprocessing pipelines for the Human Connectome Project
Glasser, M. F., Sotiropoulos, S. N., Wilson, J. A., Coalson, T. S., Fischl, B., Andersson, J. L., Xu, J., Jbabdi, S., Webster, M., Polimeni, J. R., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.127 · Cited by 5,253
What we can do and what we cannot do with fMRI
Logothetis, N. K. (2008) · Nature · doi:10.1038/nature06976 · Cited by 3,612
Self-citationResting-state fMRI in the human connectome project
Smith, S. M., Beckmann, C. F., Andersson, J., Auerbach, E. J., Bijsterbosch, J., Douaud, G., Duff, E., Feinberg, D. A., Griffanti, L., Harms, M. P., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.039 · Cited by 1,502
Self-citationClosed-loop brain training: the science of neurofeedback
Sitaram, R., Ros, T., Stoeckel, L., Haller, S., Scharnowski, F., Lewis-Peacock, J., Weiskopf, N., Blefari, M. L., Rana, M., Oblak, E., et al. (2017) · Nature Reviews Neuroscience · doi:10.1038/nrn.2016.164 · Cited by 1,306
Metadata
- Authors
- Shmuel, A., Yacoub, E., Chaimow, D., Logothetis, N. K., & Ugurbil, K.
- Affiliations
- University of Minnesota (US)
- Max Planck Institute for Biological Cybernetics (DE)
- Corresponding author
- Shmuel, Amir
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2007-04
- Volume
- 35
- Issue
- 2
- Pages
- 539-552
- ISSN
- 1053-8119 (ISSN-L)
- PMC
- PMC2989431
- OpenAlex
- W176484045
- Cited by
- 294
- References
- 57
- Citations by year
- 2026: 6 · 2025: 11 · 2024: 14 · 2023: 10 · 2022: 8 · 2021: 15 · 2020: 10 · 2019: 30 · 2018: 12 · 2017: 22 · 2016: 20 · 2015: 16 · 2014: 19 · 2013: 17 · 2012: 18
- FWCI
- 12.29
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- NeuroImage (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Max Planck Institute for Plasma Physics (submittedVersion)
- MPG.PuRe (Max Planck Society) (submittedVersion)
- Funders
- European Molecular Biology Organization
- National Institutes of Health
- National Institute of Mental Health (R01MH070800)
- National Institute of Biomedical Imaging and Bioengineering (R01 EB00331, R01EB000331)
- National Center for Research Resources (P41RR008079, P41RR08079)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Life Sciences › Neuroscience › Cognitive Neuroscience › Functional Brain Connectivity Studies
- Keywords
- point spread function, BOLD signal, functional MRI, gray matter, 7 Tesla, spatial specificity, primary visual cortex, columnar organization, stimulus duration
- MeSH terms
- Adult, Brain, Female, Humans, Magnetic Resonance Imaging, Male, Mathematics, Oxygen, Time Factors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review