The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Fast and robust multi-atlas segmentation of brain magnetic resonance images
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Desikan, R. S., Ségonne, F., Fischl, B., Quinn, B. T., Dickerson, B. C., Blacker, D., Buckner, R. L., Dale, A. M., Maguire, R. P., Hyman, B. T., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.021 · Cited by 13,324
Fast robust automated brain extraction
Smith, S. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10062 · Cited by 10,496
Fischl, B., Salat, D. H., Busa, E., Albert, M., Dieterich, M., Haselgrove, C., van der Kouwe, A., Killiany, R., Kennedy, D., Klaveness, S., et al. (2002) · Neuron · doi:10.1016/s0896-6273(02)00569-x · Cited by 8,610
Ashburner, J., & Friston, K. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.018 · Cited by 7,507 · cited 13×
“…(Ségonne et al., 2004; Smith, 2002); (b) into different tissue types such as white matter (WM), grey matter (GM), or cerebral spinal fluid (CSF) (Ashburner and Friston, 2005; Bazin and Pham, 2007; Pham and Prince, 1999; Scherrer et al., 2008; van Leemput et al., 1999; Zhang et al., 2001); or…”
InfluentialFast approximate energy minimization via graph cuts
Boykov, Y., Veksler, O., & Zabih, R. (2001) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.969114 · Cited by 6,988
Zhang, Y., Brady, M., & Smith, S. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906424 · Cited by 6,982
AVANTS, B., EPSTEIN, C., GROSSMAN, M., & GEE, J. (2008) · Medical Image Analysis · doi:10.1016/j.media.2007.06.004 · Cited by 5,669
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Self-citationMultimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547 · cited 3×
“In this work, the computation of NMI was implemented as described in Maes et al. (1997).”
MethodInfluentialEvaluation of 14 nonlinear deformation algorithms applied to human brain MRI registration
Klein, A., Andersson, J., Ardekani, B. A., Ashburner, J., Avants, B., Chiang, M.-C., Christensen, G. E., Collins, D. L., Gee, J., Hellier, P., et al. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.037 · Cited by 2,227
Self-citationA hybrid approach to the skull stripping problem in MRI
Ségonne, F., Dale, A. M., Busa, E., Glessner, M., Salat, D., Hahn, H. K., & Fischl, B. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.03.032 · Cited by 2,212
Warfield, S. K., Zou, K. H., & Wells, W. M. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.828354 · Cited by 2,072
(1998) · Lecture Notes in Computer Science · doi:10.1007/bfb0056181 · Cited by 1,577
Automated model-based tissue classification of MR images of the brain
Van Leemput, K., Maes, F., Vandermeulen, D., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811270 · Cited by 1,024
New variants of a method of MRI scale standardization
Nyul, L. G., Udupa, J. K., & Zhang, X. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.836373 · Cited by 956
Multi-atlas based segmentation of brain images: Atlas selection and its effect on accuracy
Aljabar, P., Heckemann, R. A., Hammers, A., Hajnal, J. V., & Rueckert, D. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.018 · Cited by 868
Self-citationAutomatic anatomical brain MRI segmentation combining label propagation and decision fusion
Heckemann, R. A., Hajnal, J. V., Aljabar, P., Rueckert, D., & Hammers, A. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.05.061 · Cited by 866
Self-citationAdaptive fuzzy segmentation of magnetic resonance images
Pham, D. L., & Prince, J. L. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.802752 · Cited by 805
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1997) · Medical Physics · doi:10.1118/1.598130 · Cited by 675
Rohlfing, T., Brandt, R., Menzel, R., & Maurer, C. R. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.11.010 · Cited by 573
Combination Strategies in Multi-Atlas Image Segmentation: Application to Brain MR Data
Artaechevarria, X., Munoz-Barrutia, A., & Ortiz-de-Solorzano, C. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2014372 · Cited by 507
Active Surface Approach for Extraction of the Human Cerebral Cortex from MRI
Eskildsen, S. F., & Østergaard, L. R. (2006) · Lecture Notes in Computer Science · doi:10.1007/11866763_101 · Cited by 446
(2007) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-75757-3 · Cited by 431
(2008) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-85988-8 · Cited by 428
Brain Functional Localization: A Survey of Image Registration Techniques
Gholipour, A., Kehtarnavaz, N., Briggs, R., Devous, M., & Gopinath, K. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.892508 · Cited by 274
A Bayesian model for joint segmentation and registration
Pohl, K. M., Fisher, J., Grimson, W. E. L., Kikinis, R., & Wells, W. M. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.11.044 · Cited by 273
Atlas Renormalization for Improved Brain MR Image Segmentation Across Scanner Platforms
Han, X., & Fischl, B. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.893282 · Cited by 215 · cited 11×
“Hellier (2003) estimated a mixture of Gaussians that approximates a histogram, and matched the mean intensities of the histogram peaks between images.”
BackgroundMethodResultInfluentialGuimond, A., Roche, A., Ayache, N., & Meunier, J. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906425 · Cited by 215
Hippocampus segmentation in MR images using atlas registration, voxel classification, and graph cuts
van der Lijn, F., den Heijer, T., Breteler, M. M. B., & Niessen, W. J. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.07.058 · Cited by 213
Morra, J. H., Tu, Z., Apostolova, L. G., Green, A. E., Avedissian, C., Madsen, S. K., Parikshak, N., Hua, X., Toga, A. W., Jack, C. R., et al. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.07.003 · Cited by 200
Chupin, M., Hammers, A., Liu, R. S. N., Colliot, O., Burdett, J., Bardinet, E., Duncan, J. S., Garnero, L., & Lemieux, L. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.013 · Cited by 181
Mindboggle: Automated brain labeling with multiple atlases
Klein, A., Mensh, B. D., Ghosh, S., Tourville, J. A., & Hirsch, J. (2005) · BMC Medical Imaging · doi:10.1186/1471-2342-5-7 · Cited by 143
Non-rigid registration of multi-modal images using both mutual information and cross-correlation
Andronache, A., VONSIEBENTHAL, M., Székely, G. J., & Cattin, P. C. (2007) · Medical Image Analysis · doi:10.1016/j.media.2007.06.005 · Cited by 139
Optimum template selection for atlas-based segmentation
Wu, M., Rosano, C., López-García, P., Carter, C. S., & Aizenstein, H. J. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.07.050 · Cited by 138
Comparison and Evaluation of Segmentation Techniques for Subcortical Structures in Brain MRI
Babalola, K., Patenaude, B., Aljabar, P., Schnabel, J. A., Kennedy, D. N., Crum, W. R., Smith, S. M., Cootes, T. F., Jenkinson, M., & Rueckert, D. (2008) · Lecture notes in computer science · doi:10.1007/978-3-540-85988-8_49 · Cited by 81
Self-citationIntegrated Graph Cuts for Brain MRI Segmentation
Song, Z., Tustison, N. J., Avants, B., & Gee, J. C. (2006) · Lecture notes in computer science · doi:10.1007/11866763_102 · Cited by 66
Jager, F., & Joachim Hornegger, A. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2004429 · Cited by 66
Studholme, C., Cardenas, V. A., Song, E., Ezekiel, F., Maudsley, A. A., & Weiner, M. W. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.820029 · Cited by 53
Consistent intensity correction of MR images
Pierre Hellier, J. (2004) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2003.1247161 · Cited by 42
Wolz, R., Aljabar, P., Rueckert, D., Heckemann, R. A., & Hammers, A. (2009) · 2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro · doi:10.1109/isbi.2009.5193086 · Cited by 28
Self-citationFully Bayesian Joint Model for MR Brain Scan Tissue and Structure Segmentation
Scherrer, B., Forbes, F., Garbay, C., & Dojat, M. (2008) · Lecture notes in computer science · doi:10.1007/978-3-540-85990-1_128 · Cited by 17
Anatomy-Preserving Nonlinear Registration of Deep Brain ROIs Using Confidence-Based Block-Matching
Bhattacharjee, M., Pitiot, A., Roche, A., Dormont, D., & Bardinet, É. (2008) · Lecture notes in computer science · doi:10.1007/978-3-540-85990-1_115 · Cited by 9
Atlas-based registration parameters in segmenting sub-cortical regions from brain MRI-images
Lötjönen, J. M. P., Koikkalainen, J. R., Thurfjell, L., & Rueckert, D. (2009) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2009.5192973 · Cited by 6
Self-citation
Cited by
The Alzheimer's Disease Neuroimaging Initiative: A review of papers published since its inception
Weiner, M. W., Veitch, D. P., Aisen, P. S., Beckett, L. A., Cairns, N. J., Green, R. C., Harvey, D., Jack, C. R., Jagust, W., Liu, E., et al. (2013) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2013.05.1769 · Cited by 1,010
Multi-Atlas Segmentation with Joint Label Fusion
Wang, H., Suh, J. W., Das, S. R., Pluta, J. B., Craige, C., & Yushkevich, P. A. (2013) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2012.143 · Cited by 796
“This method requires higher computational costs but, as extensive empirical studies have verified in the recent literature, e.g., [16], [3], [22], it is more accurate than single atlas-based segmentation.”
MethodVoxResNet: Deep voxelwise residual networks for brain segmentation from 3D MR images
Chen, H., Dou, Q., Yu, L., Qin, J., & Heng, P.-A. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.04.041 · Cited by 768
MRI Segmentation of the Human Brain: Challenges, Methods, and Applications
Despotović, I., Goossens, B., & Philips, W. (2015) · Computational and Mathematical Methods in Medicine · doi:10.1155/2015/450341 · Cited by 701
Patch-based segmentation using expert priors: Application to hippocampus and ventricle segmentation
Coupé, P., Manjón, J. V., Fonov, V., Pruessner, J., Robles, M., & Collins, D. L. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.09.018 · Cited by 692
Metadata
- Authors
- Lötjönen, J. M., Wolz, R., Koikkalainen, J. R., Thurfjell, L., Waldemar, G., Soininen, H., & Rueckert, D.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2010-02
- Volume
- 49
- Issue
- 3
- Pages
- 2352-2365
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2066839705
- Cited by
- 391
- References
- 43
- FWCI
- 22.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.