The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
On the importance of electrode parameters for shaping electric field patterns generated by tDCS
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jenkinson, M., Beckmann, C. F., Behrens, T. E. J., Woolrich, M. W., & Smith, S. M. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.015 · Cited by 11,314
Cortical Surface-Based Analysis
Dale, A. M., Fischl, B., & Sereno, M. I. (1999) · NeuroImage · doi:10.1006/nimg.1998.0395 · Cited by 10,910
Nitsche, M. A., & Paulus, W. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.t01-1-00633.x · Cited by 5,656
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,270
Sustained excitability elevations induced by transcranial DC motor cortex stimulation in humans
Nitsche, M. A., & Paulus, W. (2001) · Neurology · doi:10.1212/wnl.57.10.1899 · Cited by 2,617 · cited 1×
“…effects remain stable for some time after stimulation offset, rendering tDCS an interesting method to modulate cortical plasticity both in healthy subjects (Nitsche and Paulus, 2000, 2001) and disease populations such as stroke patients (Raffin and Siebner, 2014; Stagg and Johansen-Berg, 2013).”
Localization of the motor hand area to a knob on the precentral gyrus. A new landmark
Yousry, T. (1997) · Brain · doi:10.1093/brain/120.1.141 · Cited by 1,837
The Biomedical Engineering Handbook
Bronzino, J. D., & Peterson, D. R. (2018) · CRC Press eBooks · doi:10.1201/b18423 · Cited by 1,599
Datta, A., Bansal, V., Diaz, J., Patel, J., Reato, D., & Bikson, M. (2009) · Brain Stimulation · doi:10.1016/j.brs.2009.03.005 · Cited by 1,290
Modeling the current distribution during transcranial direct current stimulation
Miranda, P. C., Lomarev, M., & Hallett, M. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.04.009 · Cited by 762
Bikson, M., Inoue, M., Akiyama, H., Deans, J. K., Fox, J. E., Miyakawa, H., & Jefferys, J. G. R. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2003.055772 · Cited by 743
Shaping the Effects of Transcranial Direct Current Stimulation of the Human Motor Cortex
Nitsche, M. A., Doemkes, S., Karaköse, T., Antal, A., Liebetanz, D., Lang, N., Tergau, F., & Paulus, W. (2007) · Journal of Neurophysiology · doi:10.1152/jn.01312.2006 · Cited by 738
Kuo, H.-I., Bikson, M., Datta, A., Minhas, P., Paulus, W., Kuo, M.-F., & Nitsche, M. A. (2013) · Brain Stimulation · doi:10.1016/j.brs.2012.09.010 · Cited by 695
Determinants of the electric field during transcranial direct current stimulation
Opitz, A., Paulus, W., Will, S., Antunes, A., & Thielscher, A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.01.033 · Cited by 690
Self-citationOptimized multi-electrode stimulation increases focality and intensity at target
Dmochowski, J. P., Datta, A., Bikson, M., Su, Y., & Parra, L. C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046011 · Cited by 590
Transcranial direct current stimulation: A computer-based human model study
Wagner, T., Fregni, F., Fecteau, S., Grodzinsky, A., Zahn, M., & Pascual-Leone, A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.01.027 · Cited by 567 · cited 3×
“It was demonstrated that the currents are strongest underneath the electrode borders, in particular underneath the ones closer to the other electrode (Miranda et al., 2006; Miranda et al., 2013; Wagner et al., 2007).”
Cellular effects of acute direct current stimulation: somatic and synaptic terminal effects
Rahman, A., Reato, D., Arlotti, M., Gasca, F., Datta, A., Parra, L. C., & Bikson, M. (2013) · The Journal of Physiology · doi:10.1113/jphysiol.2012.247171 · Cited by 560
Windhoff, M., Opitz, A., & Thielscher, A. (2013) · Human Brain Mapping · doi:10.1002/hbm.21479 · Cited by 441
Self-citationImpact of the gyral geometry on the electric field induced by transcranial magnetic stimulation
Thielscher, A., Opitz, A., & Windhoff, M. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.061 · Cited by 439
Self-citationDular, P., Geuzaine, C., Henrotte, F., & Legros, W. (1998) · IEEE Transactions on Magnetics · doi:10.1109/20.717799 · Cited by 351
Evaluation of commercially available electrodes and gels for recording of slow EEG potentials
Tallgren, P., Vanhatalo, S., Kaila, K., & Voipio, J. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.10.001 · Cited by 344
The electric field in the cortex during transcranial current stimulation
Miranda, P. C., Mekonnen, A., Salvador, R., & Ruffini, G. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.12.034 · Cited by 334
Transcranial current stimulation focality using disc and ring electrode configurations: FEM analysis
Datta, A., Elwassif, M., Battaglia, F., & Bikson, M. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/2/007 · Cited by 320
BINDMAN, L. J., LIPPOLD, O. C. J., & REDFEARN, J. W. T. (1962) · Nature · doi:10.1038/196584a0 · Cited by 314
The Biomedical Engineering Handbook: Second Edition.
Neuman, M. (1999) · Electrical Engineering Handbook · doi:10.1201/9781420049510.sec5 · Cited by 308
Modeling of the human skull in EEG source analysis
Dannhauer, M., Lanfer, B., Wolters, C. H., & Knösche, T. R. (2011) · Human Brain Mapping · doi:10.1002/hbm.21114 · Cited by 268
Minhas, P., Bansal, V., Patel, J., Ho, J. S., Diaz, J., Datta, A., & Bikson, M. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.05.007 · Cited by 267
Good vibrations: Oscillatory phase shapes perception
Neuling, T., Rach, S., Wagner, S., Wolters, C. H., & Herrmann, C. S. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.07.024 · Cited by 265
Faria, P., Hallett, M., & Miranda, P. C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/6/066017 · Cited by 243
Transcranial direct current stimulation (tDCS) in a realistic head model
Sadleir, R. J., Vannorsdall, T. D., Schretlen, D. J., & Gordon, B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.052 · Cited by 232
Kabakov, A. Y., Muller, P. A., Pascual-Leone, A., Jensen, F. E., & Rotenberg, A. (2012) · Journal of Neurophysiology · doi:10.1152/jn.00715.2011 · Cited by 230 · cited 1×
“Large parts of the field are oriented parallel rather than perpendicular to the cortical sheet and it is suggested that these parallel currents are also effective in modulating neural activity (Kabakov et al., 2012; Rahman et al., 2013).”
Datta, A., Bikson, M., & Fregni, F. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.04.252 · Cited by 211
Truong, D. Q., Magerowski, G., Blackburn, G. L., Bikson, M., & Alonso-Alonso, M. (2013) · NeuroImage: Clinical · doi:10.1016/j.nicl.2013.05.011 · Cited by 183
Investigation of tDCS volume conduction effects in a highly realistic head model
Wagner, S., Rampersad, S. M., Aydin, Ü., Vorwerk, J., Oostendorp, T. F., Neuling, T., Herrmann, C. S., Stegeman, D. F., & Wolters, C. H. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/1/016002 · Cited by 177
Electrodes for transcutaneous (surface) electrical stimulation
Keller, T., & Kuhn, A. (2008) · Journal of Automatic Control · doi:10.2298/jac0802035k · Cited by 158
2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC)
Aiello, M., Fabio Aloise, A., Baldoni, R., Febo Cincotti, A., Guger, C., Lazovik, A., Mecella, M., Pucci, P., Rinsma, J., Santucci, G., et al. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · Cited by 108
Gilad, O., Lior Horesh, C., & Holder, D. S. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0209-7 · Cited by 65
Stagg, C. J., & Johansen‐Berg, H. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00857 · Cited by 64
Electrode assembly design for transcranial Direct Current Stimulation: A FEM modeling study
Kronberg, G., & Bikson, M. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346075 · Cited by 54
Transcranial brain stimulation to promote functional recovery after stroke
Raffin, E., & Siebner, H. R. (2013) · Current Opinion in Neurology · doi:10.1097/wco.0000000000000059 · Cited by 37
Sehm, B., Hoff, M., Gundlach, C., Taubert, M., Conde, V., Villringer, A., & Ragert, P. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.10.006 · Cited by 20
Electrical current distribution under transthoracic defibrillation and pacing electrodes
Papazov, S. P., Kostov, Z., & Daskalov, I. (2002) · Journal of Medical Engineering & Technology · doi:10.1080/03091900110102454 · Cited by 19
Conductive Differences in Electrodes Used with Transcutaneous Electrical Nerve Stimulation Devices
Nolan, M. F. (1991) · Physical Therapy · doi:10.1093/ptj/71.10.746 · Cited by 14
Cited by
Evidence-based guidelines on the therapeutic use of transcranial direct current stimulation (tDCS)
Lefaucheur, J.-P., Antal, A., Ayache, S. S., Benninger, D. H., Brunelin, J., Cogiamanian, F., Cotelli, M., De Ridder, D., Ferrucci, R., Langguth, B., et al. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2016.10.087 · Cited by 1,826
Antal, A., Alekseichuk, I., Bikson, M., Brockmöller, J., Brunoni, A. R., Chen, R., Cohen, L. G., Dowthwaite, G., Ellrich, J., Flöel, A., et al. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.06.001 · Cited by 1,301
Effects of tDCS on motor learning and memory formation: A consensus and critical position paper
Buch, E. R., Santarnecchi, E., Antal, A., Born, J., Celnik, P. A., Classen, J., Gerloff, C., Hallett, M., Hummel, F. C., Nitsche, M. A., et al. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.01.004 · Cited by 367
Bergmann, T. O., Karabanov, A., Hartwigsen, G., Thielscher, A., & Siebner, H. R. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.02.012 · Cited by 358
Self-citationNielsen, J. D., Madsen, K. H., Puonti, O., Siebner, H. R., Bauer, C., Madsen, C. G., Saturnino, G. B., & Thielscher, A. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.03.001 · Cited by 271
Self-citation
Metadata
- Authors
- Saturnino, G. B., Antunes, A., & Thielscher, A.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2015-10
- Volume
- 120
- Pages
- 25-35
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W811236349
- Cited by
- 263
- References
- 42
- FWCI
- 7.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.