Optimizing the ICA-based removal of ocular EEG artifacts from free viewing experiments
Open accessThe DOI matches its Crossref record; 118 of the 118 references it cites were found in a registry or an index.
Abstract
Abstract Combining EEG with eye-tracking is a promising approach to study neural correlates of natural vision, but the resulting recordings are also heavily contaminated by activity of the eye balls, eye lids, and extraocular muscles. While Independent Component Analysis (ICA) is commonly used to suppress these ocular artifacts, its performance under free viewing conditions has not been systematically evaluated and many published findings display residual artifacts. Here I evaluated and optimized ICA-based correction for two tasks with unconstrained eye movements: visual search in images and sentence reading. In a first step, four parameters of the ICA pipeline were systematically varied: the (1) high-pass and (2) low-pass filter applied to the training data, (3) the proportion of training data containing myogenic saccadic spike potentials (SP), and (4) the threshold for eye tracker-based component rejection. In a second step, the eye-tracker was used to objectively quantify correction quality of each ICA solution, both in terms of undercorrection (residual artifacts) and overcorrection (removal of neurogenic activity). As a benchmark, results were compared to those obtained with an alternative spatial filter, Multiple Source Eye Correction (MSEC). With commonly used settings, Infomax ICA not only left artifacts in the data of both tasks, but also distorted neurogenic activity during eye movement-free intervals. However, correction could be drastically improved by training the ICA on optimally filtered data in which SPs were massively overweighted. With optimized procedures, ICA removed virtually all artifacts, including the SP and its associated spectral broadband artifact, with little distortion of neural activity. It also outperformed MSEC in terms of SP correction. Matlab code is provided. Author Note I would like to acknowledge Maarten De Schuymer, who conducted early explorations of the effects of high-pass filtering that helped to initiate the current work. I am also grateful to Lisa Spiering for assisting with the MSEC correction and Werner Sommer for providing an excellent working environment. Collection of one of the datasets was supported by a grant from DFG (FG-868-A2). Comments or corrections are highly appreciated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371 · cited 5×
“In a fi rst step, I created 20 copies of the continuous EEG recording and high-pass fi ltered them differently using EEGLAB's (Delorme and Makeig, 2004) standard fi lter function pop_eeg-fi ltnew.m (a zero-phase Hamming-windowed sinc FIR fi lter, Widmann et al., 2015) with its default, frequency-dependent transition bandwi…”
InfluentialAn Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986
Eye movements in reading and information processing: 20 years of research
Rayner, K. (1998) · Psychological Bulletin · doi:10.1037/0033-2909.124.3.372 · Cited by 7,979
ERPLAB: an open-source toolbox for the analysis of event-related potentials
Lopez-Calderon, J., & Luck, S. J. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00213 · Cited by 2,584 · cited 1×
“To make the datasets directly comparable, the raw data of both experiments was high-pass fi ltered at 0.016 Hz (10 s time constant) using ERPLAB's Butterworth fi lter ( pop_basic fi lter.m , Lopez-Calderon and Luck, 2014).”
MethodInfluentialLee, T.-W., Girolami, M., & Sejnowski, T. J. (1999) · Neural Computation · doi:10.1162/089976699300016719 · Cited by 1,967 · cited 1×
“Rather than proposing yet another correction method, goal of the present study was therefore to validate and adapt the pipeline for the widely-used extended Infomax algorithm (Bell and Sej-nowski, 1995; Lee et al., 1999) to natural viewing.”
Delorme, A., Sejnowski, T., & Makeig, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.004 · Cited by 1,759 · cited 2×
“Of these, Independent Component Analysis (ICA) is now perhaps most commonly used to remove occasional saccade and blink artifacts in steady-fi xation experiments (Delorme et al., 2007; Jung et al., 2000).”
Reference-free identification of components of checkerboard-evoked multichannel potential fields
Lehmann, D., & Skrandies, W. (1980) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(80)90419-8 · Cited by 1,552
Microsaccades uncover the orientation of covert attention
Engbert, R., & Kliegl, R. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00084-1 · Cited by 1,390 · cited 4×
“Similarly, significant eye movements during fixation – in particular microsaccades – can be detected with suitable algorithms (Engbert and Kliegl, 2003).”
BackgroundResultInfluentialJung, T.-P., Makeig, S., Westerfield, M., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00386-2 · Cited by 1,322 · cited 1×
“Of these, Independent Component Analysis (ICA) is now perhaps most commonly used to remove occasional saccade and blink artifacts in steady-fi xation experiments (Delorme et al., 2007; Jung et al., 2000).”
ADJUST: An automatic EEG artifact detector based on the joint use of spatial and temporal features
Mognon, A., Jovicich, J., Bruzzone, L., & Buiatti, M. (2011) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01061.x · Cited by 1,290 · cited 1×
“Non-ocular artifacts such as cardiac activity show similar variance during both intervals and are not fl agged; they can be detected with other techniques (Campos Viola et al., 2009; Chaumon et al., 2015; Mognon et al., 2011; Nolan et al., 2010; Winkler et al., 2011).”
FASTER: Fully Automated Statistical Thresholding for EEG artifact Rejection
Nolan, H., Whelan, R., & Reilly, R. B. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.07.015 · Cited by 1,077 · cited 1×
“Non-ocular artifacts such as cardiac activity show similar variance during both intervals and are not fl agged; they can be detected with other techniques (Campos Viola et al., 2009; Chaumon et al., 2015; Mognon et al., 2011; Nolan et al., 2010; Winkler et al., 2011).”
The Oxford Handbook of Eye Movements
(2011) · Oxford University Press eBooks · doi:10.1093/oxfordhb/9780199539789.001.0001 · Cited by 874
Chaumon, M., Bishop, D. V. M., & Busch, N. A. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.02.025 · Cited by 833 · cited 2×
“Non-ocular artifacts such as cardiac activity show similar variance during both intervals and are not fl agged; they can be detected with other techniques (Campos Viola et al., 2009; Chaumon et al., 2015; Mognon et al., 2011; Nolan et al., 2010; Winkler et al., 2011).”
BackgroundMethodIndependent EEG Sources Are Dipolar
Delorme, A., Palmer, J., Onton, J., Oostenveld, R., & Makeig, S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0030135 · Cited by 810 · cited 1×
“Filtering at 1 or 2 Hz produced the most dipolar ICs (Delorme et al., 2012), the best discrimination between targets/non-targets, and the least noisy ERPs.”
Automatic Classification of Artifactual ICA-Components for Artifact Removal in EEG Signals
Winkler, I., Haufe, S., & Tangermann, M. (2011) · Behavioral and Brain Functions · doi:10.1186/1744-9081-7-30 · Cited by 778 · cited 1×
“Non-ocular artifacts such as cardiac activity show similar variance during both intervals and are not fl agged; they can be detected with other techniques (Campos Viola et al., 2009; Chaumon et al., 2015; Mognon et al., 2011; Nolan et al., 2010; Winkler et al., 2011).”
BackgroundTransient induced gamma-band response in EEG as a manifestation of miniature saccades
Yuval-Greenberg, S., Tomer, O., Keren, A. S., Nelken, I., & Deouell, L. Y. (2008) · Neuron · doi:10.1016/j.neuron.2008.03.027 · Cited by 776
Removal of ocular artifact from the EEG: a review
Croft, R. J., & Barry, R. J. (2000) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/s0987-7053(00)00055-1 · Cited by 756
Ille, N., Berg, P., & Scherg, M. (2002) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200203000-00002 · Cited by 741 · cited 2×
“Like ICA, MSEC can be described as a spatial fi lter (Ille et al., 2002), which separates brain and artifact activities based on their topographical de fi nitions (for details, see the Supplementary Materials, Supplement A).”
BackgroundMethodDigital filter design for electrophysiological data – a practical approach
Widmann, A., Schröger, E., & Maess, B. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.08.002 · Cited by 711 · cited 5×
“Importantly, it should be noted that the most suitable cutoff frequency also depends on the characteristics of the fi lter used (Widmann et al., 2015), in particular its steepness (transition bandwidth).”
BackgroundMethodInfluentialA multiple source approach to the correction of eye artifacts
Berg, P., & Scherg, M. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90094-9 · Cited by 696 · cited 20×
“Importantly, for both Scenes and Reading, MSEC failed to remove the SP, which was only reduced to about a third of its original amplitude in the radial EOG (see Fig.”
BackgroundMethodInfluentialImaging human EEG dynamics using independent component analysis
Onton, J., Westerfield, M., Townsend, J., & Makeig, S. (2006) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2006.06.007 · Cited by 673 · cited 1×
“2 The length of the training data ( k ¼ 80 points per weight) was de fi ned arbitrarily, but clearly exceeds minimum recommendations for mid-density EEG montages (e.g., k ¼ 20 in Onton et al., 2006; k ¼ 30 in Miyakoshi, 2019).”
Coregistration of eye movements and EEG in natural reading: Analyses and review.
Dimigen, O., Sommer, W., Hohlfeld, A., Jacobs, A. M., & Kliegl, R. (2011) · Journal of Experimental Psychology: General · doi:10.1037/a0023885 · Cited by 602 · cited 9×
“Artifacts are only one of four challenges when analyzing EEG experiments with multiple saccades (Dimigen et al., 2011).”
BackgroundMethodInfluentialSelf-citationez: Easy Analysis and Visualization of Factorial Experiments
Lawrence, M. A. (2009) · CRAN: Contributed Packages · doi:10.32614/cran.package.ez · Cited by 569
Castellanos, N. P., & Makarov, V. A. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.05.033 · Cited by 569 · cited 3×
“A question less often discussed is whether ICA removes brain activity observed in the task (overcorrection; e.g. Castellanos and Makarov, 2006; Mennes et al., 2010; Pontifex et al., 2016; see Ries et al., 2018 for a recent investigation with FRPs).”
Independent Component Analysis: A Tutorial Introduction
(2007) · Technometrics · doi:10.1198/004017007000000191 · Cited by 551
Microsaccades: Small steps on a long way
Rolfs, M. (2009) · Vision Research · doi:10.1016/j.visres.2009.08.010 · Cited by 521 · cited 1×
“…one might suspect that these changes in the stimulus-ERP were not really caused by “ over-correction ” , but simply re fl ect the removal of tiny, overlooked artifacts elicited by undetected microsaccades (Meyberg et al., 2017; Pl € ochl et al., 2012) or other fi xational eye movements (Rolfs, 2009).”
Removal of Movement Artifact From High-Density EEG Recorded During Walking and Running
Gwin, J. T., Gramann, K., Makeig, S., & Ferris, D. P. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00105.2010 · Cited by 481 · cited 2×
“High cutoffs around 40 – 45 Hz are therefore commonly applied to ICA input data (e.g. Castellanos and Makarov, 2006; Gwin et al., 2010; Mannan et al., 2016; Ries et al., 2018; Winkler et al., 2015; Zakeri et al., 2014).”
Independent Component Analysis: A Tutorial Introduction
Stone, J. V. (2004) · The MIT Press eBooks · doi:10.7551/mitpress/3717.001.0001 · Cited by 445
On the influence of high-pass filtering on ICA-based artifact reduction in EEG-ERP
Winkler, I., Debener, S., Muller, K.-R., & Tangermann, M. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319296 · Cited by 407
Plöchl, M., Ossandón, J. P., & König, P. (2012) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2012.00278 · Cited by 372 · cited 14×
“…one might suspect that these changes in the stimulus-ERP were not really caused by “ over-correction ” , but simply re fl ect the removal of tiny, overlooked artifacts elicited by undetected microsaccades (Meyberg et al., 2017; Pl € ochl et al., 2012) or other fi xational eye movements (Rolfs, 2009).”
BackgroundMethodResultInfluentialSemi-automatic identification of independent components representing EEG artifact
Campos Viola, F., Thorne, J., Edmonds, B., Schneider, T., Eichele, T., & Debener, S. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.01.015 · Cited by 364 · cited 1×
“Non-ocular artifacts such as cardiac activity show similar variance during both intervals and are not fl agged; they can be detected with other techniques (Campos Viola et al., 2009; Chaumon et al., 2015; Mognon et al., 2011; Nolan et al., 2010; Winkler et al., 2011).”
Background(2013) · Choice Reviews Online · doi:10.5860/choice.50-5912 · Cited by 308
Large-scale replication study reveals a limit on probabilistic prediction in language comprehension
Nieuwland, M. S., Politzer-Ahles, S., Heyselaar, E., Segaert, K., Darley, E., Kazanina, N., Von Grebmer Zu Wolfsthurn, S., Bartolozzi, F., Kogan, V., Ito, A., et al. (2018) · eLife · doi:10.7554/elife.33468 · Cited by 299
Saccadic spike potentials in gamma-band EEG: Characterization, detection and suppression
Keren, A. S., Yuval-Greenberg, S., & Deouell, L. Y. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.10.057 · Cited by 263 · cited 9×
“SP amplitude increases with saccade size, although it is unclear whether this relationship is linear (Keren et al., 2010) or not (Boylan and Ross Doig, 1989).”
InfluentialLins, O. G., Picton, T. W., Berg, P., & Scherg, M. (1993) · Brain Topography · doi:10.1007/bf01234128 · Cited by 225 · cited 1×
“A smaller blink-like artifact – sometimes called eye “ rider artifact ” (Lins et al., 1993) – also occurs towards the end of upward or oblique-upward saccades (Barry and Jones, 1965; Pl € ochl et al., 2012) and is believed to be caused by the eye lids lagging behind the upward-rotating eye balls,…”
Saccadic Inhibition in Voluntary and Reflexive Saccades
Reingold, E. M., & Stampe, D. M. (2002) · Journal of Cognitive Neuroscience · doi:10.1162/089892902317361903 · Cited by 221 · cited 1×
“Although intervals without microsaccades are rare, they can be found immediately after stimulus onsets, since any suf fi ciently strong stimulation triggers saccadic inhibition, a transient decrease in the rate of saccades (Reingold and Stampe, 2002) and microsaccades (Engbert and Kliegl, 2003).”
BackgroundVisual Psychophysics and Physiology
(1978) · Elsevier eBooks · doi:10.1016/b978-0-12-062260-3.x5001-1 · Cited by 218
Dissociating neuronal gamma-band activity from cranial and ocular muscle activity in EEG
Hipp, J. F., & Siegel, M. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00338 · Cited by 217 · cited 3×
“A myogenic rather than cerebral source is also suggested by its frontal generators (Carl et al., 2012; Hipp and Siegel, 2013), its presence in darkness (Riggs et al., 1974) and intramuscular EMG (Yamazaki, 1968) as well as its weakness or absence in intracranial EEG (Jerbi et al., 2009; Kovach et…”
Validation of ICA-based myogenic artifact correction for scalp and source-localized EEG
McMenamin, B. W., Shackman, A. J., Maxwell, J. S., Bachhuber, D. R. W., Koppenhaver, A. M., Greischar, L. L., & Davidson, R. J. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.10.010 · Cited by 211 · cited 1×
“Thus, overcorrection can happen because the ICA produces mixed non-neural/neural ICs (e.g. Castellanos and Makarov, 2006; McMenamin et al., 2010) but also because the experimenter accidently removes neurogenic ICs.”
Kusunoki, M., & Goldberg, M. E. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00519.2002 · Cited by 209 · cited 1×
“Second, the SP greatly complicates the study of phenomena occurring in temporal proximity to saccade onset, such as remapping (Kusunoki and Goldberg, 2003), saccadic suppression (Duffy and Lombroso, 1968), or saccade-related changes in cortical excitability (Ito et al., 2011).”
BackgroundIdentifying reliable independent components via split-half comparisons
Groppe, D. M., Makeig, S., & Kutas, M. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.038 · Cited by 207 · cited 4×
“From each epoch, I then removed the mean channel voltages across the epoch (mean-centering, Groppe et al., 2009).”
InfluentialThe correction of ocular artifacts: a topographic perspective
Picton, T. W., van Roon, P., Armilio, M. L., Berg, P., Ille, N., & Scherg, M. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00227-8 · Cited by 205 · cited 1×
“However, artifact topographies are not strictly mirrosymmetric for upward versus downward saccades (Picton et al., 2000; Pl € ochl et al., 2012) and have also been reported to depend on the participant's absolute screen viewing position (Ai et al., 2016), which of course changes frequently during…”
Dipole models of eye movements and blinks
Berg, P., & Scherg, M. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90154-v · Cited by 200 · cited 1×
“…of which are the voltage distortions produced by rotation of the eye balls, movements of the eye lids, and contraction of the extraocular muscles (Berg and Scherg, 1991; Keren et al., 2010; Picton et al., 2000; Pl€ochl et al., arly explorations of the effects of high-pass filtering that helped…”
BackgroundArtoni, F., Delorme, A., & Makeig, S. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.03.016 · Cited by 198 · cited 1×
“…the neural ICs in source space instead (and wants to avoid problems associated with re-running ICA on rank-reduced data after removing EMG sources; Artoni et al., 2018), it may be better to keep the low-pass fi lter and only optimize the other two parameters (high-pass and overweighting), since…”
Ehinger, B. V., & Dimigen, O. (2019) · PeerJ · doi:10.7717/peerj.7838 · Cited by 178 · cited 1×
“…latter two are effectively addressed by analyzing the artifact-corrected EEG with regression-based linear deconvolution models (Burns et al., 2013; Cornelissen et al., 2019; Dandekar et al., 2011; Dimigen and Ehinger, 2019; Ehinger & Dimigen, 2019; Kristensen et al., 2017; Smith and Kutas, 2015).”
Self-citationHuman Microsaccade-Related Visual Brain Responses
Dimigen, O., Valsecchi, M., Sommer, W., & Kliegl, R. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.0911-09.2009 · Cited by 176 · cited 2×
“…have received attention because even involuntary microsaccades ( < 1 (cid:1) ) during attempted fi xation generate sizeable SPs (Armington, 1978; Dimigen et al., 2009; Yamazaki, 1968; Yuval-Green-berg et al., 2008), which introduce a broadband artifact in the time-frequency spectrum of the EEG,…”
Self-citation3.1 Using ICA for the Analysis of Multi-Channel EEG Data
Debener, S., Thorne, J., Schneider, T. R., & Viola, F. C. (2010) · Simultaneous EEG and fMRI · doi:10.1093/acprof:oso/9780195372731.003.0008 · Cited by 169 · cited 1×
“Finally, to aid component identifica tion, Hassler et al. (2011) proposed an unconventional use of ICA for which “virtual” chann els are added to the data, which contain a copy of the SP waveform (averaged across frontal ch nnels) during microsaccade intervals, but zeros elsewhere.”
MethodHigh-frequency broadband modulation of electroencephalographic spectra
Onton, J. (2009) · Frontiers in Human Neuroscience · doi:10.3389/neuro.09.061.2009 · Cited by 156
Dimigen, O., Kliegl, R. M., & Sommer, W. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.04.006 · Cited by 151 · cited 1×
“…are dif fi cult to model with ICA and most existing reports display residual SP artifacts in the plotted waveforms (for arbitrarily picked examples see Dimigen et al., 2012; Henderson et al., 2013; Kamienkowski et al., 2012; K € orner et al., 2014; Kornrumpf et al., 2016; Nikolaev et al., 2011;…”
BackgroundSelf-citationFixation-related potentials in visual search: A combined EEG and eye tracking study
Kamienkowski, J. E., Ison, M. J., Quiroga, R. Q., & Sigman, M. (2012) · Journal of Vision · doi:10.1167/12.7.4 · Cited by 147 · cited 1×
“…reports display residual SP artifacts in the plotted waveforms (for arbitrarily picked examples see Dimigen et al., 2012; Henderson et al., 2013; Kamienkowski et al., 2012; K € orner et al., 2014; Kornrumpf et al., 2016; Nikolaev et al., 2011; Ossandon et al., 2010; Ries et al., 2018; Simola et…”
Suppression of visual phosphenes during saccadic eye movements
Riggs, L. A., Merton, P. A., & Morton, H. (1974) · Vision Research · doi:10.1016/0042-6989(74)90169-2 · Cited by 146 · cited 1×
“…rather than cerebral source is also suggested by its frontal generators (Carl et al., 2012; Hipp and Siegel, 2013), its presence in darkness (Riggs et al., 1974) and intramuscular EMG (Yamazaki, 1968) as well as its weakness or absence in intracranial EEG (Jerbi et al., 2009; Kovach et al.,…”
Dealing with artifacts: The EOG contamination of the event-related brain potential
Gratton, G. (1998) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03209415 · Cited by 142 · cited 1×
“A multitude of methods has been proposed for ocular correction, including those based on EEG-on-EOG regression, dipole modelling/ beamforming, PCA, and other variants of blind source separation (Brunia et al., 1989; Delorme et al., 2007; Gratton, 1998; Ille et al., 2002).”
Encyclopedia of Medical Devices and Instrumentation
Griffiths, H. J. (1989) · Radiology · doi:10.1148/radiology.170.3.1016 · Cited by 140
Combining EEG and eye movement recording in free viewing: Pitfalls and possibilities
Nikolaev, A. R., Meghanathan, R. N., & van Leeuwen, C. (2016) · Brain and Cognition · doi:10.1016/j.bandc.2016.06.004 · Cited by 139 · cited 2×
“Throughout all analyses, EOG electrodes remained in the data and were treated like EEG channels (which is crucial to detect residual artifacts and ocular ICs; Dimigen et al., 2011; Nikolaev et al., 2016).”
Regression-based analysis of combined EEG and eye-tracking data: Theory and applications
Dimigen, O., & Ehinger, B. (2021) · Journal of Vision · doi:10.1167/jov.21.1.3 · Cited by 139
Self-citationSaccade-Related Modulations of Neuronal Excitability Support Synchrony of Visually Elicited Spikes
Ito, J., Maldonado, P., Singer, W., & Grun, S. (2011) · Cerebral Cortex · doi:10.1093/cercor/bhr020 · Cited by 136 · cited 1×
“Second, the SP greatly complicates the study of phenomena occurring in temporal proximity to saccade onset, such as remapping (Kusunoki and Goldberg, 2003), saccadic suppression (Duffy and Lombroso, 1968), or saccade-related changes in cortical excitability (Ito et al., 2011).”
Eye-movement measurement techniques.
Young, L. R., & Sheena, D. (1975) · American Psychologist · doi:10.1037//0003-066x.30.3.315 · Cited by 128 · cited 1×
“…to metabolic activity in the pigmented layer of the retina (Marmor and Zrenner, 1993), each eye ball posesses an electrical gradient of one to several millivolts (depending on ambient illumination level, Marmor and Zrenner, 1993; Young and Sheena, 1988) between its front (cornea) and back (retina).”
Becker, W., Hoehne, O., Iwase, K., & Kornhuber, H. H. (1972) · Vision Research · doi:10.1016/0042-6989(72)90087-9 · Cited by 122 · cited 1×
“However, most of the lateralized potentials related to attention shifts (Eimer, 2014) or oculomotor preparation (Becker et al., 1972; Berchicci et al., 2012; Everling et al., 1996; Moster and Goldberg, 1990) have been observed before rather than after the saccade and post-saccadic effects (Meyberg…”
BackgroundManifestation of ocular-muscle EMG contamination in human intracranial recordings
Kovach, C. K., Tsuchiya, N., Kawasaki, H., Oya, H., Howard, M. A., & Adolphs, R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.08.002 · Cited by 121 · cited 1×
“…and Siegel, 2013), its presence in darkness (Riggs et al., 1974) and intramuscular EMG (Yamazaki, 1968) as well as its weakness or absence in intracranial EEG (Jerbi et al., 2009; Kovach et al., 2011; Sakamoto et al., 1991) and patients with extraocular muscle palsy (Thickbroom & Mastaglia, 1985).”
Jerbi, K., Freyermuth, S., Dalal, S. S., Kahane, P., Bertrand, O., Berthoz, A., & Lachaux, J.-P. (2009) · Brain Topography · doi:10.1007/s10548-009-0078-5 · Cited by 120 · cited 1×
“…and Siegel, 2013), its presence in darkness (Riggs et al., 1974) and intramuscular EMG (Yamazaki, 1968) as well as its weakness or absence in intracranial EEG (Jerbi et al., 2009; Kovach et al., 2011; Sakamoto et al., 1991) and patients with extraocular muscle palsy (Thickbroom & Mastaglia, 1985).”
Preview benefit and parafoveal-on-foveal effects from word n + 2.
Kliegl, R., Risse, S., & Laubrock, J. (2007) · Journal of Experimental Psychology: Human Perception and Performance · doi:10.1037/0096-1523.33.5.1250 · Cited by 120
Validation of ICA as a tool to remove eye movement artifacts from EEG/ERP
Mennes, M., Wouters, H., Vanrumste, B., Lagae, L., & Stiers, P. (2010) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01015.x · Cited by 116 · cited 1×
“Obviously, the success of this procedure depends on an appropriate threshold. Although a value of 1 seems like a logical choice, Plöchl et al. (2012) proposed using a slightly higher threshold (1.”
BackgroundThe saccadic spike artifact in MEG
Carl, C., Açık, A., König, P., Engel, A. K., & Hipp, J. F. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.020 · Cited by 110
Smith, N. J., & Marta Kutas, A. (2014) · Psychophysiology · doi:10.1111/psyp.12320 · Cited by 110 · cited 1×
“…latter two are effectively addressed by analyzing the artifact-corrected EEG with regression-based linear deconvolution models (Burns et al., 2013; Cornelissen et al., 2019; Dandekar et al., 2011; Dimigen and Ehinger, 2019; Ehinger & Dimigen, 2019; Kristensen et al., 2017; Smith and Kutas, 2015).”
Co-registration of eye movements and event-related potentials in connected-text paragraph reading
Henderson, J. M., Luke, S. G., Schmidt, J., & Richards, J. E. (2013) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2013.00028 · Cited by 98 · cited 2×
“Similar settings have also been used in SRP/FRP research (e.g. 0.5 Hz; as used in Henderson et al., 2013; Nikolaev et al., 2011; and Ossandon et al., 2010).”
InfluentialBrouwer, A.-M., Reuderink, B., Vincent, J., van Gerven, M. A. J., & van Erp, J. B. F. (2013) · Journal of Vision · doi:10.1167/13.3.17 · Cited by 93
Presaccadic ‘spike’ potential: Investigation of topography and source
Thickbroom, G. W., & Mastaglia, F. L. (1985) · Brain Research · doi:10.1016/0006-8993(85)90092-7 · Cited by 92 · cited 3×
“…and Siegel, 2013), its presence in darkness (Riggs et al., 1974) and intramuscular EMG (Yamazaki, 1968) as well as its weakness or absence in intracranial EEG (Jerbi et al., 2009; Kovach et al., 2011; Sakamoto et al., 1991) and patients with extraocular muscle palsy (Thickbroom & Mastaglia, 1985).”
Kornrumpf, B., Niefind, F., Sommer, W., & Dimigen, O. (2016) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_00977 · Cited by 92 · cited 2×
“Because MSEC has been shown to produce good cor-neoretinal correction in natural reading (e.g. Dimigen et al., 2011; Kornrumpf et al., 2016) is was considered a suitable benchmark.”
Self-citationCortical potentials preceding pro- and antisaccades in man
Everling, S., Krappmann, P., & Flohr, H. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)96569-4 · Cited by 89 · cited 1×
“…most of the lateralized potentials related to attention shifts (Eimer, 2014) or oculomotor preparation (Becker et al., 1972; Berchicci et al., 2012; Everling et al., 1996; Moster and Goldberg, 1990) have been observed before rather than after the saccade and post-saccadic effects (Meyberg et al.,…”
Induced gamma band responses in human EEG after the control of miniature saccadic artifacts
Hassler, U., Trujillo‐Barreto, N. J., & Gruber, T. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.05.062 · Cited by 87 · cited 3×
“Complete removal of SPs with ICA has proven challenging even for microsaccades (Craddock et al., 2016; Hassler et al., 2011; Hipp and Siegel, 2013; Keren et al., 2010) and ICA often fails to single out the SP in one or more distinct ICs (Hipp and Siegel, 2013; Keren et al., 2010).”
Correcting ocular artifacts in the EEG: A comparison of several methods
BRUNIA, C. H. M., Möcks, J., & van den Berg-Lenssen, M. M. C. (1989) · Research portal (Tilburg University) · Cited by 86
INFLUENCE OF EYE LID MOVEMENT UPON ELECTRO-OCULOGRAPHIC RECORDING OF VERTICAL EYE MOVEMENTS.
BARRY, W., & Jones, G. M. (1965) · PubMed · Cited by 86
Dambacher, M., Dimigen, O., Braun, M., Wille, K., Jacobs, A. M., & Kliegl, R. M. (2012) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2012.04.011 · Cited by 84 · cited 2×
“…dif fi cult to model with ICA and most existing reports display residual SP artifacts in the plotted waveforms (for arbitrarily picked examples see Dimigen et al., 2012; Henderson et al., 2013; Kamienkowski et al., 2012; K € orner et al., 2014; Kornrumpf et al., 2016; Nikolaev et al., 2011;…”
Self-citationDifferences of monkey and human overt attention under natural conditions
Einhäuser, W., Kruse, W., Hoffmann, K., & König, P. (2005) · Vision Research · doi:10.1016/j.visres.2005.08.032 · Cited by 81 · cited 1×
“Most images were taken from the Zurich Natural Image Database (Einh € auser et al., 2006), a set of photographs shot in a forest.”
BackgroundElectrical phenomena associated with movements of the eyelid
Matsuo, F., Peters, J. F., & Reilly, E. L. (1975) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(75)90191-1 · Cited by 80
Online Removal of Eye Movement and Blink EEG Artifacts Using a High-Speed Eye Tracker
Noureddin, B., Lawrence, P. D., & Birch, G. E. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2108295 · Cited by 79 · cited 1×
“…accurate gaze position signal that is electrically independent of the EEG and therefore potentially useful to improve ocular correction (Dimigen et al., 2011; Hironaga et al., 2004; Kierkels et al., 2007; Lourenço et al., 2016; Mannan et al., 2016; Noureddin et al., 2012; Pl € ochl et al., 2012).”
Topography of scalp potentials preceding self‐initiated saccades
Moster, M. L., & Goldberg, G. (1990) · Neurology · doi:10.1212/wnl.40.4.644 · Cited by 77 · cited 1×
“…potentials related to attention shifts (Eimer, 2014) or oculomotor preparation (Becker et al., 1972; Berchicci et al., 2012; Everling et al., 1996; Moster and Goldberg, 1990) have been observed before rather than after the saccade and post-saccadic effects (Meyberg et al., 2015) have been…”
Standard for clinical electro-oculography
Marmor, M. F., & Zrenner, E. (1993) · Documenta Ophthalmologica · doi:10.1007/bf01371127 · Cited by 77 · cited 2×
“Due to metabolic activity in the pigmented layer of the retina (Marmor and Zrenner, 1993), each eye ball posesses an electrical gradient of one to several millivolts (depending on ambient illumination level, Marmor and Zrenner, 1993; Young and Sheena, 1988) between its front (cornea) and back…”
Neural saccadic response estimation during natural viewing
Dandekar, S., Privitera, C. M., Carney, T., & Klein, S. A. (2011) · Journal of Neurophysiology · doi:10.1152/jn.00237.2011 · Cited by 75 · cited 1×
“…latter two are effectively addressed by analyzing the artifact-corrected EEG with regression-based linear deconvolution models (Burns et al., 2013; Cornelissen et al., 2019; Dandekar et al., 2011; Dimigen and Ehinger, 2019; Ehinger & Dimigen, 2019; Kristensen et al., 2017; Smith and Kutas, 2015).”
Variability of ICA decomposition may impact EEG signals when used to remove eyeblink artifacts
Pontifex, M. B., Gwizdala, K. L., Parks, A. C., Billinger, M., & Brunner, C. (2016) · Psychophysiology · doi:10.1111/psyp.12804 · Cited by 74 · cited 2×
“A question less often discussed is whether ICA removes brain activity observed in the task (overcorrection; e.g. Castellanos and Makarov, 2006; Mennes et al., 2010; Pontifex et al., 2016; see Ries et al., 2018 for a recent investigation with FRPs).”
Duffy, F. H., & LOMBROSO, C. T. (1968) · Nature · doi:10.1038/2181074a0 · Cited by 69 · cited 1×
“Second, the SP greatly complicates the study of phenomena occurring in temporal proximity to saccade onset, such as remapping (Kusunoki and Goldberg, 2003), saccadic suppression (Duffy and Lombroso, 1968), or saccade-related changes in cortical excitability (Ito et al., 2011).”
Superposition Model Predicts EEG Occipital Activity during Free Viewing of Natural Scenes
Ossandón, J., Helo, A., Montefusco‐Siegmund, R., & Maldonado, P. (2010) · Journal of Neuroscience · doi:10.1523/jneurosci.5769-09.2010 · Cited by 66 · cited 2×
“Similar settings have also been used in SRP/FRP research (e.g. 0.5 Hz; as used in Henderson et al., 2013; Nikolaev et al., 2011; and Ossandon et al., 2010).”
InfluentialMetzner, P., von der Malsburg, T., Vasishth, S., & Rösler, F. (2014) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_00731 · Cited by 57
Electrophysiological correlates of presaccadic remapping in humans
Parks, N. A., & Corballis, P. M. (2008) · Psychophysiology · doi:10.1111/j.1469-8986.2008.00669.x · Cited by 56 · cited 1×
“In contrast, there is little persuasive evidence for cerebral contributions to the SP itself (Balaban and Wein-stein, 1985; Berchicci et al., 2012; Parks and Corballis, 2008), although relevant cortical activity may of course take place during the same interval (e.g. Parks and Corballis, 2008).”
Mannan, M. M. N., Kim, S., Jeong, M., & Kamran, M. A. (2016) · Sensors · doi:10.3390/s16020241 · Cited by 54
Microsaccade-related brain potentials signal the focus of visuospatial attention
Meyberg, S., Werkle‐Bergner, M., Sommer, W., & Dimigen, O. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.09.065 · Cited by 53
Self-citationBaccino, T. (2011) · Oxford University Press eBooks · doi:10.1093/oxfordhb/9780199539789.013.0047 · Cited by 51
Eye movement related brain responses to emotional scenes during free viewing
Simola, J., Torniainen, J., Moisala, M., Kivikangas, M., & Krause, C. M. (2013) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2013.00041 · Cited by 50
Presaccadic spike potential. Relation to eye movement direction
Thickbroom, G. W., & Mastaglia, F. L. (1986) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(86)90167-7 · Cited by 48
Dandekar, S., Ding, J., Privitera, C. M., Carney, T., & Klein, S. A. (2012) · PLoS ONE · doi:10.1371/journal.pone.0048761 · Cited by 47
Eye fixation-related potentials in free viewing identify encoding failures in change detection
Nikolaev, A. R., Nakatani, C., Plomp, G., Jurica, P., & van Leeuwen, C. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.03.021 · Cited by 46 · cited 2×
“Similar settings have also been used in SRP/FRP research (e.g. 0.5 Hz; as used in Henderson et al., 2013; Nikolaev et al., 2011; and Ossandon et al., 2010).”
BackgroundMethodInfluentialUsing an Eye Tracker for Accurate Eye Movement Artifact Correction
Kierkels, J. J. M., Riani, J., Bergmans, J. W. M., & Boxtel, G. J. M. V. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889179 · Cited by 45 · cited 1×
“Similarly, Meyberg et al . (2017) found that only the inclusion of 15° saccades in the training data allowed for the r emoval of small CR artifacts produced by microsaccades.”
BackgroundRies, A. J., Slayback, D., & Touryan, J. (2018) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2018.09.004 · Cited by 45 · cited 4×
“A question less often discussed is whether ICA removes brain activity observed in the task (overcorrection; e.g. Castellanos and Makarov, 2006; Mennes et al., 2010; Pontifex et al., 2016; see Ries et al., 2018 for a recent investigation with FRPs).”
BackgroundMethodInfluentialFlying characteristics of the new official rubber baseball
Aoki, K., Nagase, J., & Nakayama, Y. (2009) · Journal of Visualization · doi:10.1007/bf03181935 · Cited by 45
Balaban, C. D., & Weinstein, J. M. (1985) · Brain Research · doi:10.1016/0006-8993(85)90888-1 · Cited by 41
Brain Responses to Emotional Faces in Natural Settings: A Wireless Mobile EEG Recording Study
Soto, V., Tyson‐Carr, J., Kokmotou, K., Roberts, H., Cook, S., Fallon, N. B., Giesbrecht, T., & Stančák, A. (2018) · Frontiers in Psychology · doi:10.3389/fpsyg.2018.02003 · Cited by 41
Comparison of averaging and regression techniques for estimating Event Related Potentials
Burns, M. D., Bigdely-Shamlo, N., Smith, N. J., Kreutz-Delgado, K., & Makeig, S. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609841 · Cited by 35 · cited 1×
“…2017), whereas the latter two are effectively addressed by analyzing the artifact-corrected EEG with regression-based linear deconvolution models (Burns et al., 2013; Cornelissen et al., 2019; Dandekar et al., 2011; Dimigen and Ehinger, 2019; Ehinger & Dimigen, 2019; Kristensen et al., 2017;…”
How microsaccades relate to lateralized ERP components of spatial attention: A co-registration study
Meyberg, S., Sommer, W., & Dimigen, O. (2017) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2017.02.023 · Cited by 33 · cited 2×
“Similarly, Meyberg et al. (2017) found that only the inclusion of 15 saccades in the training data allowed for the removal of small CR artifacts produced by microsaccades.”
Self-citationIntracranial Recordings of Movement-Related Potentials to Voluntary Saccades
Sakamoto, A. C., Lüders, H. O., & Burgess, R. C. (1991) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199104000-00011 · Cited by 32
Reva, N. V., & Aftanas, L. I. (2003) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2003.09.005 · Cited by 30
Improving free-viewing fixation-related EEG potentials with continuous-time regression
Cornelissen, T. H. W., Sassenhagen, J., & Võ, M. L. ‐. (2018) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2018.12.010 · Cited by 29 · cited 2×
“…latter two are effectively addressed by analyzing the artifact-corrected EEG with regression-based linear deconvolution models (Burns et al., 2013; Cornelissen et al., 2019; Dandekar et al., 2011; Dimigen and Ehinger, 2019; Ehinger & Dimigen, 2019; Kristensen et al., 2017; Smith and Kutas, 2015).”
BackgroundKörner, C., Braunstein, V., Stangl, M., Schlögl, A., Neuper, C., & Ischebeck, A. K. (2014) · Psychophysiology · doi:10.1111/psyp.12062 · Cited by 29 · cited 1×
“…display residual SP artifacts in the plotted waveforms (for arbitrarily picked examples see Dimigen et al., 2012; Henderson et al., 2013; Kamienkowski et al., 2012; K € orner et al., 2014; Kornrumpf et al., 2016; Nikolaev et al., 2011; Ossandon et al., 2010; Ries et al., 2018; Simola et al., 2013).”
BackgroundInfluence of Signal Preprocessing on ICA-Based EEG Decomposition
Zakeri, Z., Assecondi, S., Bagshaw, A. P., & Arvanitis, T. N. (2013) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-319-00846-2_182 · Cited by 27
Craddock, M., Martinović, J., & Müller, M. M. (2015) · Psychophysiology · doi:10.1111/psyp.12593 · Cited by 27 · cited 4×
“Complete removal of SPs with ICA has proven challenging even for microsaccades (Craddock et al., 2016; Hassler et al., 2011; Hipp and Siegel, 2013; Keren et al., 2010) and ICA often fails to single out the SP in one or more distinct ICs (Hipp and Siegel, 2013; Keren et al., 2010).”
InfluentialKristensen, E., Rivet, B., & Guérin-Dugué, A. (2017) · Journal of Eye Movement Research · doi:10.16910/jemr.10.1.7 · Cited by 26 · cited 1×
“…latter two are effectively addressed by analyzing the artifact-corrected EEG with regression-based linear deconvolution models (Burns et al., 2013; Cornelissen et al., 2019; Dandekar et al., 2011; Dimigen and Ehinger, 2019; Ehinger & Dimigen, 2019; Kristensen et al., 2017; Smith and Kutas, 2015).”
BackgroundA crucial temporal accuracy test of combining EEG and Tobii eye tracker
Xue, J., Quan, C., Li, C., Yue, J., & Zhang, C. (2017) · Medicine · doi:10.1097/md.0000000000006444 · Cited by 26 · cited 1×
“The fi rst of these problem can now be solved with dedicated toolboxes (such as EYE-EEG, see also Baekgaard et al., 2014; Xue et al., 2017), whereas the latter two are effectively addressed by analyzing the artifact-corrected EEG with regression-based linear deconvolution models (Burns et al., 2013;…”
BackgroundFocal anterior temporal spikes from external rectus muscle
Blinn, K. A. (1955) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(55)90043-2 · Cited by 25 · cited 1×
“Spike potential : The most dif fi cult-to-correct artifact is the saccadic spike potential (SP), a brief, high-frequency biphasic wave, which ramps up ~5 – 10 ms before the saccade and reaches its primary peak at saccade onset (Blinn, 1955; Keren et al., 2010; see Carl et al., 2012 for MEG).”
Potentials That Precede Small Saccades
Armington, J. C. (1978) · Elsevier eBooks · doi:10.1016/b978-0-12-062260-3.50035-6 · Cited by 25 · cited 11×
“7 (the data shown is based on ICAs trained on data lowpass filtered at 100Hz with overweighted SPs, since these settings provided the best SP correction, see above).”
BackgroundInfluentialEffect of saccade size on presaccadic spike potential amplitude.
Boylan, C., & Doig, H. R. (1989) · PubMed · Cited by 21
Ai, G., Sato, N., Singh, B., & Wagatsuma, H. (2016) · Cognitive Neurodynamics · doi:10.1007/s11571-016-9382-4 · Cited by 17 · cited 1×
“…topographies are not strictly mirrosymmetric for upward versus downward saccades (Picton et al., 2000; Pl € ochl et al., 2012) and have also been reported to depend on the participant's absolute screen viewing position (Ai et al., 2016), which of course changes frequently during free viewing.”
BackgroundIn the twinkling of an eye: Synchronization of EEG and eye tracking based on blink signatures
Bækgaard, P., Petersen, M. K., & Larsen, J. E. (2014) · International Workshop on Cognitive Information Processing (CIP) · doi:10.1109/cip.2014.6844504 · Cited by 15
The Time Course of Spatial Attention
Eimer, M. (2014) · Oxford University Press eBooks · doi:10.1093/oxfordhb/9780199675111.013.006 · Cited by 14 · cited 2×
“However, most of the lateralized potentials related to attention shifts (Eimer, 2014) or oculomotor preparation (Becker et al., 1972; Berchicci et al., 2012; Everling et al., 1996; Moster and Goldberg, 1990) have been observed before rather than after the saccade and post-saccadic effects (Meyberg…”
BackgroundJanani, A. S., Grummett, T. S., Bakhshayesh, H., Lewis, T. W., Willoughby, J. O., & Pope, K. J. (2018) · European Signal Processing Conference (EUSIPCO) · doi:10.23919/eusipco.2018.8553261 · Cited by 14
Marton, M., Szirtes, J., & Breuer, P. (1985) · International Journal of Psychophysiology · doi:10.1016/0167-8760(85)90033-9 · Cited by 14
Chen, P. L., & Machado, L. (2017) · Journal of Eye Movement Research · doi:10.16910/jemr.10.3.5 · Cited by 13
Spatio-temporal mapping of motor preparation for self-paced saccades
Berchicci, M., Stella, A., Pitzalis, S., Spinelli, D., & Russo, F. D. (2012) · Biological Psychology · doi:10.1016/j.biopsycho.2012.02.014 · Cited by 12 · cited 2×
“In contrast, there is little persuasive evidence for cerebral contributions to the SP itself (Balaban and Wein-stein, 1985; Berchicci et al., 2012; Parks and Corballis, 2008), although relevant cortical activity may of course take place during the same interval (e.g. Parks and Corballis, 2008).”
Human presaccadic spike potentials. Of central or peripheral origin?
Nativ, A., Weinstein, J. M., & Rosas-Ramos, R. (1990) · PubMed · Cited by 8
Supervised EEG Ocular Artefact Correction Through Eye-Tracking
Lourenço, P. R., Abbott, W. W., & Faisal, A. A. (2015) · Biosystems & biorobotics · doi:10.1007/978-3-319-26242-0_7 · Cited by 5 · cited 1×
“…accurate gaze position signal that is electrically independent of the EEG and therefore potentially useful to improve ocular correction (Dimigen et al., 2011; Hironaga et al., 2004; Kierkels et al., 2007; Lourenço et al., 2016; Mannan et al., 2016; Noureddin et al., 2012; Pl € ochl et al., 2012).”
Cited by
Klug, M., & Gramann, K. (2021) · European Journal of Neuroscience · doi:10.1111/ejn.14992 · Cited by 268
Metadata
- Authors
- Dimigen, O.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2020-02
- Volume
- 207
- Pages
- 116117
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2898824151
- Cited by
- 222
- References
- 118
- FWCI
- 10.41
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.