Wireless EEG: A survey of systems and studies
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
The popular brain monitoring method of electroencephalography (EEG) has seen a surge in commercial attention in recent years, focusing mostly on hardware miniaturization. This has led to a varied landscape of portable EEG devices with wireless capability, allowing them to be used by relatively unconstrained users in real-life conditions outside of the laboratory. The wide availability and relative affordability of these devices provide a low entry threshold for newcomers to the field of EEG research. The large device variety and the at times opaque communication from their manufacturers, however, can make it difficult to obtain an overview of this hardware landscape. Similarly, given the breadth of existing (wireless) EEG knowledge and research, it can be challenging to get started with novel ideas. Therefore, this paper first provides a list of 48 wireless EEG devices along with a number of important-sometimes difficult-to-obtain-features and characteristics to enable their side-by-side comparison, along with a brief introduction to each of these aspects and how they may influence one's decision. Secondly, we have surveyed previous literature and focused on 110 high-impact journal publications making use of wireless EEG, which we categorized by application and analyzed for device used, number of channels, sample size, and participant mobility. Together, these provide a basis for informed decision making with respect to hardware and experimental precedents when considering new, wireless EEG devices and research. At the same time, this paper provides background material and commentary about pitfalls and caveats regarding this increasingly accessible line of research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The FAIR Guiding Principles for scientific data management and stewardship
Wilkinson, M. D., Dumontier, M., Aalbersberg, I. J., Appleton, G., Axton, M., Baak, A., Blomberg, N., Boiten, J.-W., da Silva Santos, L. B., Bourne, P. E., et al. (2016) · Scientific Data · doi:10.1038/sdata.2016.18 · Cited by 18,423
The PRISMA 2020 statement: an updated guideline for reporting systematic reviews
Page, M. J., McKenzie, J., Bossuyt, P., Boutron, I., Hoffmann, T., mulrow, C., Shamseer, L., Tetzlaff, J., Akl, E., Brennan, S. E., et al. (2020) · doi:10.31222/osf.io/v7gm2_v1 · Cited by 8,090
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“This has been one of the main focuses of BCI research in the past (Wolpaw et al. 2002), although, as we can also see in this study, research focusing specifically on passive BCI is gaining in prevalence (Eddy et al.”
Power failure: why small sample size undermines the reliability of neuroscience
Button, K. S., Ioannidis, J. P. A., Mokrysz, C., Nosek, B. A., Flint, J., Robinson, E. S. J., & Munafò, M. R. (2013) · Nature Reviews Neuroscience · doi:10.1038/nrn3475 · Cited by 7,641 · cited 1×
“See (Button et al. 2013) for a critique of sample sizes in neuroimaging research, which, as we can see, clearly applies to the wireless EEG subfield as well.”
The PRISMA 2020 statement: an updated guideline for reporting systematic reviews
Page, M. J., McKenzie, J., Bossuyt, P., Boutron, I., Hoffmann, T., mulrow, C., Shamseer, L., Tetzlaff, J., Akl, E., Brennan, S. E., et al. (2020) · doi:10.31222/osf.io/v7gm2 · Cited by 5,177
A review of classification algorithms for EEG-based brain–computer interfaces: A 10 year update
Lotte, F., Bougrain, L., Cichocki, A., Clerc, M., Congedo, M., Rakotomamonjy, A., & Yger, F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab2f2 · Cited by 2,239
Scanning the horizon: towards transparent and reproducible neuroimaging research
Poldrack, R. A., Baker, C. I., Durnez, J., Gorgolewski, K. J., Matthews, P. M., Munafò, M. R., Nichols, T. E., Poline, J.-B., Vul, E., & Yarkoni, T. (2017) · Nature Reviews Neuroscience · doi:10.1038/nrn.2016.167 · Cited by 1,410 · cited 1×
“33 ‘replication crisis’ (Poldrack et al. 2017; Shrout and Rodgers 2018), referring to difficulty or”
Katsigiannis, S., & Ramzan, N. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2688239 · Cited by 1,135
Brain-to-brain synchrony tracks real-world dynamic group interactions in the classroom
Dikker, S., Wan, L., Davidesco, I., Kaggen, L., Oostrik, M., McClintock, J., Rowland, J., Michalareas, G., Van Bavel, J. J., Ding, M., et al. (2017) · Current Biology · doi:10.1016/j.cub.2017.04.002 · Cited by 871
Where Does EEG Come From and What Does It Mean?
Cohen, M. X. (2017) · Trends in Neurosciences · doi:10.1016/j.tins.2017.02.004 · Cited by 722
The urban brain: Analysing outdoor physical activity with mobile EEG
Aspinall, P., Mavros, P., Coyne, R., & Roe, J. (2015) · British Journal of Sports Medicine · doi:10.1136/bjsports-2012-091877 · Cited by 574
How about taking a low‐cost, small, and wireless EEG for a walk?
Debener, S., Minow, F., Emkes, R., Gandras, K., & de Vos, M. (2012) · Psychophysiology · doi:10.1111/j.1469-8986.2012.01471.x · Cited by 540
Validation of the Emotiv EPOC ® EEG gaming system for measuring research quality auditory ERPs
Badcock, N. A., Mousikou, P., Mahajan, Y., de Lissa, P., Thie, J., & McArthur, G. (2013) · PeerJ · doi:10.7717/peerj.38 · Cited by 397
Arnal, P. J., Thorey, V., Debellemaniere, E., Ballard, M. E., Bou Hernandez, A., Guillot, A., Jourde, H., Harris, M., Guillard, M., Van Beers, P., et al. (2020) · SLEEP · doi:10.1093/sleep/zsaa097 · Cited by 394
Bevilacqua, D., Davidesco, I., Wan, L., Chaloner, K., Rowland, J., Ding, M., Poeppel, D., & Dikker, S. (2019) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_01274 · Cited by 312
Estimating Brain Load from the EEG
Holm, A., Lukander, K., Korpela, J., Sallinen, M., & Müller, K. M. I. (2009) · The Scientific World JOURNAL · doi:10.1100/tsw.2009.83 · Cited by 287
Imaging natural cognition in action
Gramann, K., Ferris, D. P., Gwin, J., & Makeig, S. (2014) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2013.09.003 · Cited by 227
ERP CORE: An open resource for human event-related potential research
Kappenman, E. S., Farrens, J. L., Zhang, W., Stewart, A. X., & Luck, S. J. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2020.117465 · Cited by 223
Kam, J. W. Y., Griffin, S., Shen, A., Patel, S., Hinrichs, H., Heinze, H.-J., Deouell, L. Y., & Knight, R. T. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.09.012 · Cited by 188 · cited 1×
“While some reports state that new dry sensor systems can be used with comparable quality to traditional systems (Kam et al. 2019), and new shapes and materials have been proposed to minimise the noise on dry sensors (e.”
Hearables: Automatic Overnight Sleep Monitoring With Standardized In-Ear EEG Sensor
Nakamura, T., Alqurashi, Y. D., Morrell, M. J., & Mandic, D. P. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2911423 · Cited by 147
Grønli, J., Byrkjedal, I. K., Bjorvatn, B., Nødtvedt, Ø., Hamre, B., & Pallesen, S. (2016) · Sleep Medicine · doi:10.1016/j.sleep.2016.02.006 · Cited by 103
Closed-loop digital meditation improves sustained attention in young adults
Ziegler, D. A., Simon, A. J., Gallen, C. L., Skinner, S., Janowich, J. R., Volponi, J. J., Rolle, C. E., Mishra, J., Kornfield, J., Anguera, J. A., et al. (2019) · Nature Human Behaviour · doi:10.1038/s41562-019-0611-9 · Cited by 97
Computer-assisted EEG diagnostic review for idiopathic generalized epilepsy
Clarke, S., Karoly, P. J., Nurse, E., Seneviratne, U., Taylor, J., Knight-Sadler, R., Kerr, R., Moore, B., Hennessy, P., Mendis, D., et al. (2021) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2019.106556 · Cited by 55
Cited by
Mobile cognition: imaging the human brain in the ‘real world’
Stangl, M., Maoz, S. L., & Suthana, N. (2023) · Nature Reviews Neuroscience · doi:10.1038/s41583-023-00692-y · Cited by 183
EEG of the Dancing Brain: Decoding Sensory, Motor, and Social Processes during Dyadic Dance
Bigand, F., Bianco, R., Abalde, S. F., Nguyen, T., & Novembre, G. (2025) · The Journal of Neuroscience · doi:10.1523/jneurosci.2372-24.2025 · Cited by 21
Wireless optically pumped magnetometer MEG
Cheng, H., He, K., Li, C., Ma, X., Zheng, F., Xu, W., Liao, P., Yang, R., Li, D., Qin, L., et al. (2024) · NeuroImage · doi:10.1016/j.neuroimage.2024.120864 · Cited by 11
Metadata
- Authors
- Niso, G., Romero, E., Moreau, J. T., Araujo, A., & Krol, L. R.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2023-04
- Volume
- 269
- Pages
- 119774
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W4312193421
- Cited by
- 244
- References
- 23
- FWCI
- 24.69
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.