The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Experimental verification of the role of interstitial fluid pressurization in cartilage lubrication
Open accessAbstract
The objective of the current study was to measure the friction coefficient simultaneously with the interstitial fluid load support in bovine articular cartilage, while sliding against glass under a constant load. Ten visually normal 6‐mm‐diameter cartilage plugs harvested from the humeral head of four bovine shoulder joints (ages 2–4 months) were tested in a custom friction device under reciprocating linear motion (range of translation ± 2 mm; sliding velocity 1 mm/s), subjected to a 4.5 N constant load. The frictional coefficient was found to increase with time from a minimum value of μ min = 0.010 ± 0.007 (mean ± SD) to a maximum value of 0.243 ± 0.044 over a duration ranging from 920 to 19,870 s (median: 4,560 s). The corresponding interstitial fluid load support decreased from a maximum of 88.8 ± 3.8% to 8.7 ± 8.6%. A linear correlation was observed between the frictional coefficient and interstitial fluid load support (r2 = 0.96 ± 0.03). These results support the hypothesis that the temporal variation of the frictional coefficient correlates negatively with the interstitial fluid load support and that consequently interstitial fluid load support is a primary mechanism regulating the frictional response in articular cartilage. Fitting the experimental data to a previously proposed biphasic boundary lubrication model for cartilage yielded an equilibrium friction coefficient of μ eq = 0.284 ± 0.044. The fraction of the apparent contact area over which the solid cartilage matrix was in contact with the glass slide was predicted at π = 1.7 ± 6.3%, significantly smaller than the solid volume fraction of the tissue, π s = 13.8 ± 1.8%. The model predictions suggest that mixed lubrication prevailed at the contact interface under the loading conditions employed in this study. © 2003 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biphasic Creep and Stress Relaxation of Articular Cartilage in Compression: Theory and Experiments
Mow, V. C., Kuei, S. C., Lai, W. M., & Armstrong, C. G. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138202 · Cited by 2,444
Depth‐dependent confined compression modulus of full‐thickness bovine articular cartilage
Schinagl, R. M., Gurskis, D., Chen, A. C., & Sah, R. L. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150404 · Cited by 646
The frictional properties of animal joints
McCutchen, C. W. (1962) · Wear · doi:10.1016/0043-1648(62)90176-x · Cited by 640
An Analysis of the Unconfined Compression of Articular Cartilage
Armstrong, C. G., Lai, W. M., & Mow, V. C. (1984) · Journal of Biomechanical Engineering · doi:10.1115/1.3138475 · Cited by 552
Soltz, M. A., & Ateshian, G. A. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00105-5 · Cited by 504
Self-citationAkizuki, S., Mow, V. C., Müller, F., Pita, J. C., Howell, D. S., & Manicourt, D. H. (1986) · Journal of Orthopaedic Research · doi:10.1002/jor.1100040401 · Cited by 504
The Influence of Loading Time and Lubricant on the Friction of Articular Cartilage
Forster, H., & Fisher, J. (1996) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/pime_proc_1996_210_399_02 · Cited by 383
Flannery, C. R., Hughes, C. E., Schumacher, B. L., Tudor, D., Aydelotte, M. B., Kuettner, K. E., & Caterson, B. (1999) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.1998.0104 · Cited by 358
“Boosted lubrication” in synovial joints by fluid entrapment and enrichment.
Walker, P. S., Dowson, D., Longfield, M. D., & Wright, V (1968) · Annals of the Rheumatic Diseases · doi:10.1136/ard.27.6.512 · Cited by 336
Soltz, M. A., & Ateshian, G. A. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.1324669 · Cited by 330
Self-citationMacConaill, M. A. (1932) · PubMed · Cited by 317
Mechanism of Animal Joints: Sponge-hydrostatic and Weeping Bearings
McCUTCHEN, C. W. (1959) · Nature · doi:10.1038/1841284a0 · Cited by 273
Forster, H., & Fisher, J. (1999) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411991535167 · Cited by 269
Jay, G. D., Tantravahi, U., Britt, D. E., Barrach, H. J., & Cha, C. (2001) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(00)00040-1 · Cited by 253
Hills, B. A. (2000) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411001535264 · Cited by 253
Lubrication of Animal Joints: I. THE ARTHROTRIPSOMETER
LINN, F. C. (1967) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-196749060-00005 · Cited by 251
Cartilage interstitial fluid load support in unconfined compression
Park, S., Krishnan, R., Nicoll, S. B., & Ateshian, G. A. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00231-8 · Cited by 243
Self-citationSoltz, M. A., & Ateshian, G. A. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.239 · Cited by 236
Self-citationRecent Developments in Synovial Joint Biomechanics
Mow, V. C., & Lai, W. M. (1980) · SIAM Review · doi:10.1137/1022056 · Cited by 235
Swann, D. A., Slayter, H. S., & Silver, F. H. (1981) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)69297-5 · Cited by 229
Micro-Elastohydrodynamic Lubrication of Synovial Joints
Dowson, D., & Jin, Z.-M. (1986) · Engineering in Medicine · doi:10.1243/emed_jour_1986_015_019_02 · Cited by 226
The Lubrication of Animal Joints in Relation to Surgical Reconstruction by Arthroplasty
Charnley, J. (1960) · Annals of the Rheumatic Diseases · doi:10.1136/ard.19.1.10 · Cited by 218
Cartilage Stresses in the Human Hip Joint
Macirowski, T., Tepic, S., & Mann, R. W. (1994) · Journal of Biomechanical Engineering · doi:10.1115/1.2895693 · Cited by 208
Ateshian, G. A., & Wang, H. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00008-6 · Cited by 206
Self-citationWang, C. C.-B., Deng, J.-M., Ateshian, G. A., & Hung, C. T. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1503795 · Cited by 205
Self-citationSchumacher, B. L., Hughes, C. E., Kuettner, K. E., Caterson, B., & Aydelotte, M. B. (1999) · Journal of Orthopaedic Research · doi:10.1002/jor.1100170117 · Cited by 201
Oligolamellar lubrication of joints by surface active phospholipid.
Hills, B. A. (1989) · PubMed · Cited by 196
Li, L. P., Buschmann, M. D., & Shirazi-Adl, A. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00153-6 · Cited by 193
Ateshian, G. A., Wang, H., & Lai, W. M. (1998) · Journal of Tribology · doi:10.1115/1.2834416 · Cited by 192
Self-citationSeparation of a Hyaluronate-free Lubricating Fraction from Synovial Fluid
RADIN, E. L., SWANN, D. A., & WEISSER, P. A. (1970) · Nature · doi:10.1038/228377a0 · Cited by 188
A Theoretical Formulation for Boundary Friction in Articular Cartilage
Ateshian, G. A. (1997) · Journal of Biomechanical Engineering · doi:10.1115/1.2796069 · Cited by 167
Self-citationLinn, F. C., & Radin, E. L. (1968) · Arthritis & Rheumatism · doi:10.1002/art.1780110510 · Cited by 160
Volumetric changes of articular cartilage during stress relaxation in unconfined compression
Zenobi‐Wong, M., Ponticiello, M. S., Kovanen, V., & Jurvelin, J. S. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00084-1 · Cited by 144
Krishnan, R., Park, S., Eckstein, F., & Ateshian, G. A. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1610018 · Cited by 135
Self-citationSome new evidence on human joint lubrication.
Unsworth, A., Dowson, D., & Wright, V. A. (1975) · Annals of the Rheumatic Diseases · doi:10.1136/ard.34.4.277 · Cited by 111
Jones, E. (1934) · The Lancet · doi:10.1016/s0140-6736(00)56557-x · Cited by 99
Jones, E. S. (1936) · The Lancet · doi:10.1016/s0140-6736(01)37157-x · Cited by 87
Pickard, J. E., Fisher, J., Ingham, E., et al. (1998) · Biomaterials · doi:10.1016/s0142-9612(98)00147-1 · Cited by 72
LUBRICATION WITHIN LIVING JOINTS
Barnett, C. H., & Cobbold, A. F. (1962) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.44b3.662 · Cited by 57
The lubricating activity of human synovial fluids
Swann, D. A., Bloch, K. J., Swindell, D., & Shore, E. (1984) · Arthritis & Rheumatism · doi:10.1002/art.1780270511 · Cited by 54
(1969) · PubMed · Cited by 46
1977 Symposium on biomechanics
(1976) · Mechanics Research Communications · doi:10.1016/0093-6413(76)90013-6 · Cited by 37
Contact Creep of Biphasic Cartilage Layers
Kelkar, R., & Ateshian, G. A. (1999) · Journal of Applied Mechanics · doi:10.1115/1.2789140 · Cited by 25
Self-citation
Cited by
Chung, C., & Burdick, J. A. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.08.027 · Cited by 760
Biomaterials of PVA and PVP in medical and pharmaceutical applications: Perspectives and challenges
Teodorescu, M., Bercea, M., & Morariu, S. (2019) · Biotechnology Advances · doi:10.1016/j.biotechadv.2018.11.008 · Cited by 549
The role of interstitial fluid pressurization in articular cartilage lubrication
Ateshian, G. A. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.04.040 · Cited by 533
Self-citationHydrogel design for cartilage tissue engineering: A case study with hyaluronic acid
Kim, I. L., Mauck, R. L., & Burdick, J. A. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.08.073 · Cited by 508
Recent Progress in Cartilage Lubrication
Lin, W., & Klein, J. (2021) · Advanced Materials · doi:10.1002/adma.202005513 · Cited by 446
Metadata
- Authors
- Krishnan, R., Kopacz, M., & Ateshian, G. A.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 2004-05
- Volume
- 22
- Issue
- 3
- Pages
- 565-570
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W1992614274
- Cited by
- 327
- References
- 43
- FWCI
- 4.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.