The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
A light-weight active orthosis for hip movement assistance
Open accessAbstract
In the last decades, wearable powered orthoses have been developed with the aim of augmenting or assisting motor activities. In particular, among many applications, wearable powered orthoses have been also introduced in the state of the art with the goal of providing lower-limb movement assistance in locomotion-related tasks (e.g.: walking, ascending/descending stairs) in scenarios of activities of daily living. In this paper we present a light-weight active orthosis endowed with two series elastic actuators for hip flexion-extension assistance. Along with the description of its mechatronic modules, we report the experimental characterization of the performance of the actuation and control system, as well as the usability test carried out with a healthy subject. Results showed a suitable dynamic behavior of the actuation unit: the closed-loop torque control bandwidth is about 15 Hz and the output impedance ranges from about 1 N m/rad to 35 N m/rad in the frequency spectrum between 0.2 and 3.2 Hz. Results from the tests with the healthy subject proved the overall system usability: the subject could walk with the device without being hindered and while he received a smooth assistive flexion-extension torque profile on both hip articulations. Development of a novel light-weight wearable powered bilateral pelvis orthosis.Design of a novel compact, light-weight series-elastic actuator (SEA).SEA closed-loop torque control bandwidth equal to 15 Hz.SEA output impedance ranges from 1 to 35 N m /rad in human gait frequency spectrum.The overall system usability was proved by tests with a healthy subject.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Biomechanics and Motor Control of Human Movement
Winter, D. A. (2009) · Wiley eBooks · doi:10.1002/9780470549148 · Cited by 6,066
Incidence and Economic Burden of Osteoporosis-Related Fractures in the United States, 2005–2025
Burge, R., Dawson-Hughes, B., Solomon, D. H., Wong, J. B., King, A., & Tosteson, A. (2007) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.061113 · Cited by 4,026
Pratt, G. A., & Williamson, M. M. (2002) · Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots · doi:10.1109/iros.1995.525827 · Cited by 2,206
Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327
Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,280
Robot assisted gait training with Active Leg Exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008280 · Cited by 751
Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait
Blaya, J. A., & Herr, H. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.823266 · Cited by 741
Robotic Orthosis Lokomat: a rehabilitation and research tool
Jezernik, S., Colombo, G., Keller, T., Frueh, H., & Morari, M. (2003) · Neuromodulation Technology at the Neural Interface · doi:10.1046/j.1525-1403.2003.03017.x · Cited by 503 · cited 1×
“Relevant bilateral orthoses for post50 stroke patients are the LOKOMAT [27] and the LOPES [28], ∧ the 51 latter being introduced as the first lower-limb exoskeleton with 52 inherently compliant joints.”
MethodNeurological gait disorders in elderly people: clinical approach and classification
Snijders, A. H., van de Warrenburg, B. P., Giladi, N., & Bloem, B. R. (2007) · The Lancet Neurology · doi:10.1016/s1474-4422(06)70678-0 · Cited by 499
Epidemiology of Gait Disorders in Community‐Residing Older Adults
Verghese, J., LeValley, A., Hall, C. B., Katz, M. J., Ambrose, A. F., & Lipton, R. B. (2006) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2005.00580.x · Cited by 498
Veneman, J. F., Ekkelenkamp, R., Kruidhof, R., van der Helm, F. C. T., & van der Kooij, H. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906063829 · Cited by 428
A QUASI-PASSIVE LEG EXOSKELETON FOR LOAD-CARRYING AUGMENTATION
WALSH, C. J., ENDO, K., & HERR, H. (2007) · International Journal of Humanoid Robotics · doi:10.1142/s0219843607001126 · Cited by 427
Design and control of an exoskeleton for the elderly and patients
Kong, K., & Jeon, D. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.878550 · Cited by 403
Kinematic Design to Improve Ergonomics in Human Machine Interaction
Schiele, A., & van der Helm, F. C. T. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.881565 · Cited by 386
Dynamic Hebbian learning in adaptive frequency oscillators
Righetti, L., Buchli, J., & Ijspeert, A. J. (2006) · Physica D: Nonlinear Phenomena · doi:10.1016/j.physd.2006.02.009 · Cited by 361
Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349 · cited 2×
“As it is explained in [22], bandwidth of 91 a SEA system controlled by means of a PID compensator can be 92 limited by design.”
BackgroundMethodPreliminary Evaluation of a Powered Lower Limb Orthosis to Aid Walking in Paraplegic Individuals
Farris, R. J., Quintero, H. A., & Goldfarb, M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2163083 · Cited by 342
A Longitudinal Study of Gait and Balance Dysfunction in Normal Older People
Baloh, R. W., Ying, S. H., & Jacobson, K. M. (2003) · Archives of Neurology · doi:10.1001/archneur.60.6.835 · Cited by 309
A prospective study of cerebral white matter abnormalities in older people with gait dysfunction
Whitman, G. T., Tang, T., Lin, A., & Baloh, R. W. (2001) · Neurology · doi:10.1212/wnl.57.6.990 · Cited by 299
The Berkeley Lower Extremity Exoskeleton
Kazerooni, H., & Steger, R. (2006) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.2168164 · Cited by 293
NEUROExos: a powered elbow exoskeleton for physical rehabilitation
Vitiello, N., Lenzi, T., Roccella, S., De Rossi, S. M. M., Cattin, E., Giovacchini, F., Vecchi, F., & Carrozza, M. C. (2013) · IEEE Transactions on Robotics · doi:10.1109/tro.2012.2211492 · Cited by 272
Self-citationSelf-Aligning Exoskeleton Axes Through Decoupling of Joint Rotations and Translations
Stienen, A. H. A., Hekman, E. E. G., van der Helm, F. C. T., & van der Kooij, H. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2019147 · Cited by 249
Rehabilitation Exoskeletal Robotics
Pons, J. L. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2010.936548 · Cited by 222
Oscillator-based assistance of cyclical movements: model-based and model-free approaches
Ronsse, R., Lenzi, T., Vitiello, N., Koopman, B., van Asseldonk, E., De Rossi, S. M. M., van den Kieboom, J., van der Kooij, H., Carrozza, M. C., & Ijspeert, A. J. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0816-1 · Cited by 188
Self-citationDevelopment of single leg version of HAL for hemiplegia
Kawamoto, H., Hayashi, T., Sakurai, T., Eguchi, K., & Sankai, Y. (2009) · 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2009.5333698 · Cited by 182
Passive and accurate torque control of series elastic actuators
Vallery, H., Ekkelenkamp, R., van der Kooij, H., & Buss, M. (2007) · 2007 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2007.4399172 · Cited by 169
An autonomous, underactuated exoskeleton for load-carrying augmentation
Walsh, C., Pasch, K., & Herr, H. (2006) · 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2006.281932 · Cited by 162
Human–Robot Synchrony: Flexible Assistance Using Adaptive Oscillators
Ronsse, R., Vitiello, N., Lenzi, T., van den Kieboom, J., Carrozza, M. C., & Ijspeert, A. J. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2089629 · Cited by 158
Self-citationPrevalence of gait disorders in hospitalized neurological patients
Stolze, H., Klebe, S., Baecker, C., Zechlin, C., Friege, L., Pohle, S., & Deuschl, G. (2004) · Movement Disorders · doi:10.1002/mds.20266 · Cited by 154
Progression of gait disorder and rigidity and risk of death in older persons
Wilson, R. S., Schneider, J. A., Beckett, L. A., Evans, D. A., & Bennett, D. A. (2002) · Neurology · doi:10.1212/wnl.58.12.1815 · Cited by 154
A new actuation approach for human friendly robot design
Zinn, M., Khatib, O., & Roth, B. (2004) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2004.1307159 · Cited by 153
Robotic lower limb exoskeletons using proportional myoelectric control
Ferris, D. P., & Lewis, C. L. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333984 · Cited by 136
Older people with impaired mobility have specific loci of periventricular abnormality on MRI
Benson, R. R., Guttmann, C. R. G., Wei, X., Warfield, S. K., Hall, C. B., Schmidt, J. A., Kikinis, R., & WOLFSON, L. I. (2002) · Neurology · doi:10.1212/wnl.58.1.48 · Cited by 128
A Highly Backdrivable, Lightweight Knee Actuator for Investigating Gait in Stroke
Sulzer, J., Roiz, R. A., Peshkin, M., & Patton, J. (2009) · IEEE Transactions on robotics · doi:10.1109/tro.2009.2019788 · Cited by 128
A New Actuation Approach for Human Friendly Robot Design
Zinn, M., Khatib, O., Roth, B., & Salisbury, J. K. (2007) · Springer eBooks · doi:10.1007/3-540-36268-1_9 · Cited by 121
Effects of load carriage, load position, and walking speed on energy cost of walking
Abe, D., Yanagawa, K., & Niihata, S. (2004) · Applied Ergonomics · doi:10.1016/j.apergo.2004.03.008 · Cited by 112
Investigation of Gait in Elderly Subjects Over 88 Years of Age
Bloem, B. R., Haan, J., Lagaay, A. M., et al. (1992) · Journal of Geriatric Psychiatry and Neurology · doi:10.1177/002383099200500204 · Cited by 102
Disequilibrium of unknown cause in older people
Fife, T. D., & Baloh, R. W. (1993) · Annals of Neurology · doi:10.1002/ana.410340512 · Cited by 98
Design and Control of a Lower Limb Exoskeleton for Robot-Assisted Gait Training
Beyl, P., Damme, M. V., Ham, R. V., Vanderborght, B., & Lefeber, D. (2009) · Applied Bionics and Biomechanics · doi:10.1080/11762320902784393 · Cited by 93
Self-citationAccrual of MRI white matter abnormalities in elderly with normal and impaired mobility
WOLFSON, L. I., Wei, X., Hall, C. B., Panzer, V. P., Wakefield, D. B., Benson, R. R., Schmidt, J. A., Warfield, S. K., & Guttmann, C. R. G. (2005) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2004.12.017 · Cited by 80
Real-Time Estimate of Velocity and Acceleration of Quasi-Periodic Signals Using Adaptive Oscillators
Ronsse, R., Rossi, S., Vitiello, N., Lenzi, T., Carrozza, M. C., & Ijspeert, A. J. (2013) · IEEE Transactions on Robotics · doi:10.1109/tro.2013.2240173 · Cited by 75
Self-citationA longitudinal study of oculomotor function in normal older people
Kerber, K. A., Ishiyama, G. P., & Baloh, R. W. (2005) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2005.07.009 · Cited by 72
MoonWalker, a lower limb exoskeleton able to sustain bodyweight using a passive force balancer
Krut, S., Benoit, M., Dombre, E., & Pierrot, F. (2010) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2010.5509961 · Cited by 67
Hitt, J. K., Oymagil, A. M., Sugar, T. G., Hollander, K. W., Boehler, A., & Fleeger, J. (2007) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2007.363543 · Cited by 67
Oscillator-based walking assistance: A model-free approach
Ronsse, R., Koopman, B., Vitiello, N., Lenzi, T., De Rossi, S. M. M., van den Kieboom, J., van Asseldonk, E., Carrozza, M. C., van der Kooij, H., & Ijspeert, A. J. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975352 · Cited by 50
Self-citationdo Nascimento, B. G., Vimieiro, C. B. S., Nagem, D. A. P., & Pinotti, M. (2008) · Artificial Organs · doi:10.1111/j.1525-1594.2008.00549.x · Cited by 43
Kesler, A., Leibovich, G., Herman, T., Gruendlinger, L., Giladi, N., & Hausdorff, J. M. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-27 · Cited by 35
NEUROExos: A powered elbow orthosis for post-stroke early neurorehabilitation
Cempini, M., Giovacchini, F., Vitiello, N., Cortese, M., Moisè, M., Posteraro, F., & Carrozza, M. C. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609507 · Cited by 34
Self-citationAge-Associated Changes in the Biomechanics of Gait and Gait-Related Falls in Older Adults
Ashton‐Miller, J. A. (2005) · Neurological disease and therapy · doi:10.1201/b14109-5 · Cited by 27
Cited by
State of the Art and Future Directions for Lower Limb Robotic Exoskeletons
Young, A. J., & Ferris, D. P. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2521160 · Cited by 901
The exoskeleton expansion: improving walking and running economy
Sawicki, G. S., Beck, O. N., Kang, I., & Young, A. J. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00663-9 · Cited by 424
Opportunities and challenges in the development of exoskeletons for locomotor assistance
Siviy, C., Baker, L. M., Quinlivan, B. T., Porciuncula, F., Swaminathan, K., Awad, L. N., & Walsh, C. J. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00984-1 · Cited by 258
Grimmer, M., Riener, R., Walsh, C. J., & Seyfarth, A. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0458-8 · Cited by 249
Metadata
- Authors
- Giovacchini, F., Vannetti, F., Fantozzi, M., Cempini, M., Cortese, M., Parri, A., Yan, T., Lefeber, D., & Vitiello, N.
- Venue
- Robotics and Autonomous Systems
- Publisher
- Elsevier BV
- Published
- 2015-11
- Volume
- 73
- Pages
- 123-134
- ISSN
- 0921-8890 (ISSN-L)
- OpenAlex
- W2089826029
- Cited by
- 258
- References
- 50
- FWCI
- 8.77
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.