Cited by 100Electrochemical sensors and biosensorsAdvanced biosensing and bioanalysis techniquesAnalytical Chemistry and Sensors

A realtime and continuous assessment of cortisol in ISF using electrochemical impedance spectroscopy

Open access
Venugopal, Manju, Arya, Sunil K., Chornokur, Ganna, Bhansali, Shekhar·2011·Sensors and Actuators A: Physical

Abstract

This study describes the functioning of a novel sensor to measure cortisol concentration in the interstitial fluid (ISF) of a human subject. ISF is extracted by means of vacuum pressure from micropores created on the stratum corneum layer of the skin. The pores are produced by focusing a near infrared laser on a layer of black dye material attached to the skin. The pores are viable for approximately three days after skin poration. Cortisol measurements are based on electrochemical impedance (EIS) technique. Gold microelectrode arrays functionalized with Dithiobis (succinimidyl propionate) self-assembled monolayer (SAM) have been used to fabricate an ultrasensitive, disposable, electrochemical cortisol immunosensor. The biosensor was successfully used for in-vitro measurement of cortisol in ISF. Tests in a laboratory setup show that the sensor exhibits a linear response to cortisol concentrations in the range 1 pm to 100 nM. A small pilot clinical study showed that in-vitro immunosensor readings, when compared with commercial evaluation using enzyme-linked immunoassay (ELISA) method, correlated well with cortisol levels in saliva and ISF. Further, circadian rhythm could be established between the subject's ISF and the saliva samples collected over 24 hours time-period. Cortisol levels in ISF were found reliably higher than in saliva. This Research establishes the feasibility of using impedance based biosensor architecture for a disposable, wearable cortisol detector. The projected commercial in-vivo real-time cortisol sensor device, besides being minimally invasive, will allow continuous ISF harvesting and cortisol monitoring over 24 hours even when the subject is asleep. Forthcoming, this sensor could be interfaced to a wireless health monitoring system that could transfer sensor data over existing wide-area networks such as the internet and a cellular phone network to enable real-time remote monitoring of subjects.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.sna.2011.04.028

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • ISF composition leads to reliable correlations between blood and ISF concentrations of many analytes, including electrolytes, metabolites, and proteins.

    “This function, and the associated ISF composition, lead to reliable correlations between the blood and ISF concentrations of many analytes, including electrolytes (e.g., sodium, phosphate, magnesium, potassium or calcium), metabolites (e.g., glucose, alcohol, lactate or cortisol) and proteins65-69.”

    From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [69]

  • Cortisol has been measured in human blood, serum, urine, saliva, hair, interstitial fluid, and most recently eccrine sweat.

    “Cortisol has been measured in human blood,106 serum,107 urine,107 saliva,107,108 hair,109 interstitial fluid,110 and most recently eccrine sweat.111”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 2

  1. [9]Bantle JP Thomas W Glucose measurement in patients with diabetes mellitus with dermal interstitial fluid J. Lab. Clin. Med 1997 130 436 441 9358083
  2. [23]Sun K Ramgir N Venugopal M Bhansali S Estimation of Cortisol level in interstitial fluid and saliva using electrochemical array 2008 22nd international conference, EUROSENSORS Dresden, Germany

Cited by

Sorted by citations

Authors
Venugopal, M., Arya, S. K., Chornokur, G., & Bhansali, S.
Affiliations
  • Guided Therapeutics (United States) (US)
  • University of South Florida (US)
Corresponding author
Venugopal, Manju
Venue
Sensors and Actuators A: Physical
Publisher
Elsevier BV
Published
2011-12
Volume
172
Issue
1
Pages
154-160
ISSN
0924-4247 (ISSN-L)
OpenAlex
W2021895870
Cited by
100
References
24
Citations by year
2026: 6 · 2025: 11 · 2024: 12 · 2023: 10 · 2022: 6 · 2021: 7 · 2020: 9 · 2019: 9 · 2018: 7 · 2017: 2 · 2016: 6 · 2014: 4 · 2013: 8 · 2012: 3
FWCI
3.35
Type
journal article
Language
en
Open access
Locations
  • Sensors and Actuators A Physical (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
NIH (1R43MH085474-01)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
Keywords
cortisol measurement, interstitial fluid, electrochemical impedance spectroscopy, disposable biosensor, gold microelectrode array, near-infrared laser, circadian rhythm, salivary cortisol, wearable health monitoring, remote patient monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review