Improving blood compatibility of intravascular oxygen sensors via catalytic decomposition of S-nitrosothiols to generate nitric oxide in situ
Open accessIntegrity signals
Registry
Cites
Statistics
Claims the paper makes
Cited by
Sorted by citations
Electrochemical Sensors for Clinic Analysis
Wang, Y., Xu, H. F., Zhang, J., & Li, G. (2008) · Sensors · doi:10.3390/s8042043 · Cited by 400 · see citing works
Emerging synergy between nanotechnology and implantable biosensors: A review
Vaddiraju, S., Tomazos, I., Burgess, D. J., Jain, F., & Papadimitrakopoulos, F. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.12.001 · Cited by 370 · see citing works
“The deposition of active cells on the surface of implantable sensors can also cause a significant change in the local oxygen concentration, which also can lead to significant errors in the response of the implantable biosensor (Wu et al. 2007).”
BackgroundPrivett, B. J., Shin, J. H., & Schoenfisch, M. H. (2008) · Analytical Chemistry · doi:10.1021/ac8007219 · Cited by 252 · see citing works
Wo, Y., Brisbois, E. J., Bartlett, R. H., & Meyerhoff, M. E. (2016) · Biomaterials Science · doi:10.1039/c6bm00271d · Cited by 251 · see citing works
Self-citationPotential Oxidative Stress of Gold Nanoparticles by Induced-NO Releasing in Serum
Jia, H., Liu, Y., Zhang, X. J., Han, L., Du, L. B., Tian, Q., & Xu, Y. C. (2008) · Journal of the American Chemical Society · doi:10.1021/ja808033w · Cited by 228 · see citing works
Polymer‐Based Nitric Oxide Therapies: Recent Insights for Biomedical Applications
Jen, M. C., Serrano, M. C., van Lith, R., & Ameer, G. A. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201101707 · Cited by 194 · see citing works
Approaches Toward Allowing Electroanalytical Devices to be Used in Biological Fluids
Barfidokht, A., & Gooding, J. J. (2014) · Electroanalysis · doi:10.1002/elan.201400097 · Cited by 120 · see citing works
Major, T. C., Brant, D. O., Burney, C. P., Amoako, K. A., Annich, G. M., Meyerhoff, M. E., Handa, H., & Bartlett, R. H. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.03.036 · Cited by 118 · see citing works
“% copper nanoparticles in SP-60D-60 polyurethane was prepared using a method previously reported [7].”
Self-citationScholten, K., & Meng, E. F. (2018) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2018.02.022 · Cited by 103 · see citing works
Smart sensors/actuators for biomedical applications: Review
Ponmozhi, J., Frias, C. M., Marques, A. T., & Frazão, O. (2012) · Measurement · doi:10.1016/j.measurement.2012.02.006 · Cited by 80 · see citing works
“…that occur when chemical sensors are implanted into the blood stream, that can also cause a significant change in the local oxygen concentration [125] use of a biocompatible outer coating that mimics the body tissue has been shown to minimize these negative responses while maintaining sensor…”
Electrochemical Sensors for Nitric Oxide Detection in Biological Applications
Xu, T., Scafa, N., Xu, L., Su, L., Li, C.-Z., Zhou, S.-F., Liu, Y., & Zhang, X. (2014) · Electroanalysis · doi:10.1002/elan.201300564 · Cited by 79 · see citing works
Wu, Y., & Meyerhoff, M. E. (2008) · Talanta · doi:10.1016/j.talanta.2007.06.022 · Cited by 65 · see citing works
Self-citationEnzyme Mimics for the Catalytic Generation of Nitric Oxide from Endogenous Prodrugs
Yang, T., Zelikin, A. N., & Chandrawati, R. (2020) · Small · doi:10.1002/smll.201907635 · Cited by 63 · see citing works
Reynolds, M. M., & Annich, G. M. (2011) · Organogenesis · doi:10.4161/org.7.1.14029 · Cited by 60 · see citing works
Basic Science Review: Nitric Oxide—Releasing Prosthetic Materials
Varu, V. N., Tsihlis, N. D., & Kibbe, M. R. (2008) · Vascular and Endovascular Surgery · doi:10.1177/1538574408322752 · Cited by 58 · see citing works
Implications of oxidative stress mechanisms in toxicity of nanoparticles (review)
Mocan, T., Clichici, S. V., Agoşton-Coldea, L., MOCAN, L. C., Simon, S., Ilie, I. R. P., Biris, A. S., & Mureșan, A. (2010) · Acta Physiologica Hungarica · doi:10.1556/aphysiol.97.2010.3.1 · Cited by 58 · see citing works
Yang, J., Welby, J. L., & Meyerhoff, M. E. (2008) · Langmuir · doi:10.1021/la801466e · Cited by 55 · see citing works
Self-citationWang, Y., Chen, S., Pan, Y., Gao, J., Tang, D., Kong, D., & Wang, S. (2015) · Journal of Materials Chemistry B · doi:10.1039/c5tb02080h · Cited by 50 · see citing works
Tareen, A. K., Khan, K., Rehman, S., et al. (2021) · Progress in Solid State Chemistry · doi:10.1016/j.progsolidstchem.2021.100336 · Cited by 48 · see citing works
Copper-Incorporated Collagen/Catechol Film for in Situ Generation of Nitric Oxide
Luo, R., Liu, Y., Yao, H., Jiang, L., Wang, J., Weng, Y., Zhao, A., & Huang, N. (2015) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00131 · Cited by 45 · see citing works
Jiang, T., Qi, L., & Qin, W. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03974 · Cited by 45 · see citing works
Dose controlled nitric oxide-based strategies for antibacterial property in biomedical devices
Mendhi, J., Asgari, M. S., Ratheesh, G., Prasadam, I., Yang, Y., & Xiao, Y. (2020) · Applied Materials Today · doi:10.1016/j.apmt.2020.100562 · Cited by 42 · see citing works
Yan, Q., Major, T. C., Bartlett, R. H., & Meyerhoff, M. E. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.04.026 · Cited by 41 · see citing works
“Recent research in this laboratory (Fleser et al., 2004; Frost nd Meyerhoff, 2004; Frost et al., 2002, 2005; Wu et al., 2007a,c) tronics 26 (2011) 4276– 4282 4277 and elsewhere (Major et al., 2010; Oh et al., 2005; Skrzypchak et al., 2007) has shown that polymers capable of releasing 1–15 × 10−10…”
BackgroundSelf-citationMendhi, J., Ramachandra, S. S., Prasadam, I., Ivanovski, S., Yang, Y., & Xiao, Y. (2021) · Materials Science and Engineering C · doi:10.1016/j.msec.2021.112297 · Cited by 31 · see citing works
Ren, H., Coughlin, M. A., Major, T. C., Aiello, S., Rojas Pena, A., Bartlett, R. H., & Meyerhoff, M. E. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01590 · Cited by 30 · see citing works
Self-citationLiu, Y.-Y., Liu, D., Chen, S., et al. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.05.022 · Cited by 30 · see citing works
“As mentioned earlier [11,12], copper, in either metallic form or chemical complex, should play a critical role in catalytic nitric oxide generation for improved blood compatibility.”
BackgroundInfluentialJiang, T., Qi, L., Hou, C., Fang, S., & Qin, W. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c03099 · Cited by 28 · see citing works
Fabrication and in vivo thrombogenicity testing of nitric oxide generating artificial lungs
Amoako, K. A., Montoya, P. J., Major, T. C., Suhaib, A. B., Handa, H., Brant, D. O., Meyerhoff, M. E., Bartlett, R. H., & Cook, K. E. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34655 · Cited by 28 · see citing works
Self-citationChen, S., An, J., Weng, L., Li, Y., Han, X., Wang, Y., Ding, D., Kong, D., & Wang, S. (2014) · Materials Science and Engineering C · doi:10.1016/j.msec.2014.09.040 · Cited by 27 · see citing works
Nitric oxide release for improving performance of implantable chemical sensors – A review
Cha, K. H., Wang, X., & Meyerhoff, M. E. (2017) · Applied Materials Today · doi:10.1016/j.apmt.2017.10.002 · Cited by 27 · see citing works
Self-citationThromboresistance Characterization of Extruded Nitric Oxide-Releasing Silicone Catheters
Amoako, K., Archangeli, C., Handa, H., Major, T., Meyerhoff, M., Annich, G., & Bartlett, R. (2012) · ASAIO journal (1992) · doi:10.1097/mat.0b013e31824abed5 · Cited by 21 · see citing works
Self-citationNitric oxide-generating l -cysteine-grafted graphene film as a blood-contacting biomaterial
Du, Z. H., Dou, R., Zu, M., Liu, X., Yin, W., Zhao, Y., Chen, J., Yan, L., & Gu, Z. (2016) · Biomaterials Science · doi:10.1039/c6bm00074f · Cited by 21 · see citing works
Wolf, A. K., Renehan, K., Ho, K. K. Y., Carr, B. D., Chen, C., Cornell, M. S., Ye, M., Rojas-Peña, Á., & Chen, H. (2018) · Biosensors · doi:10.3390/bios8040122 · Cited by 20 · see citing works
Self-citationElectropolymerized eugenol: Evaluation as a protective film for oxygen sensing
Paul, D. W., Prajapati, I., & Reed, M. L. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.03.090 · Cited by 19 · see citing works
Nitric Oxide: What a Vascular Surgeon Needs to Know
Popowich, D. A., Varu, V. N., & Kibbe, M. R. (2007) · Vascular · doi:10.2310/6670.2007.00051 · Cited by 19 · see citing works
“Recently,Wu and colleagues attempted to use this same technology when applied to intravascular oxygen sensors.(79) Metallic copper particles were embedded as catalysts into thin polymer coatings on the surface of intravascular electrochemical oxygen-sensing catheters.”
BackgroundWonoputri, V., Gunawan, C., Liu, S., Barraud, N., Yee, L. H., Lim, M., & Amal, R. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b10357 · Cited by 17 · see citing works
Cha, K. H., & Meyerhoff, M. E. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00430 · Cited by 16 · see citing works
Self-citationGupta, S., Amoako, K. A., Suhaib, A. B., & Cook, K. E. (2014) · Advanced Materials Interfaces · doi:10.1002/admi.201400012 · Cited by 15 · see citing works
Nitric Oxide-Generating Silicone As a Blood-Contacting Biomaterial
Amoako, K. A., & Cook, K. E. (2011) · ASAIO Journal · doi:10.1097/mat.0b013e31823b9692 · Cited by 13 · see citing works
“A relatively new approach to reduce clot formation on biomaterials is through surface release or generation of NO [6,7].”
Needle-implantable, wireless biosensor for continuous glucose monitoring
Vaddiraju, S., Kastellorizios, M., Legassey, A., Burgess, D. J., Jain, F., & Papadimitrakopoulos, F. (2015) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2015.7299421 · Cited by 13 · see citing works
McCabe, M., Hála, P., Rojas-Peña, Á., Lautner‐Csorba, O., Major, T. C., Ren, H., Bartlett, R. H., Brisbois, E. J., & Meyerhoff, M. E. (2019) · Talanta · doi:10.1016/j.talanta.2019.06.077 · Cited by 12 · see citing works
Self-citationZhang, Q., & Meyerhoff, M. E. (2021) · Electroanalysis · doi:10.1002/elan.202100174 · Cited by 11 · see citing works
Self-citationNitric Oxide generating coating alters hematoma structure and soft tissue healing
Mendhi, J., Prasadam, I., Subramaniam, S., Bai, L., Gao, W., Batra, J., Crawford, R., Yang, Y., & Xiao, Y. (2021) · Applied Materials Today · doi:10.1016/j.apmt.2020.100919 · Cited by 9 · see citing works
Electrochemical generation of nitric oxide for medical applications
White, C. J., Lehnert, N., & Meyerhoff, M. E. (2021) · Electrochemical Science Advances · doi:10.1002/elsa.202100156 · Cited by 10 · see citing works
Self-citationHan, H., Wang, K., Fan, Y., et al. (2017) · Applied Surface Science · doi:10.1016/j.apsusc.2017.07.037 · Cited by 9 · see citing works
Jeong, H., Heo, J., Choi, M., & Hong, J. (2025) · Biomacromolecules · doi:10.1021/acs.biomac.4c01798 · Cited by 10 · see citing works
Ismail, A., Griveau, S., d’Orlyé, F., Varenne, A., & Fethi Bedioui, A. (2015) · Electroanalysis · doi:10.1002/elan.201500371 · Cited by 7 · see citing works
Cu(II)-Organic Coordination Polymer Networks for Persistent Nitric Oxide Release in Tumor Therapy
Jeong, H., Kim, N. K., Park, D.-H., Youn, H., Osuji, C. O., & Doh, J. (2024) · Biomacromolecules · doi:10.1021/acs.biomac.4c01071 · Cited by 6 · see citing works
Xie, W., Jiang, C., Jiang, L., et al. (2013) · Applied Surface Science · doi:10.1016/j.apsusc.2013.06.045 · Cited by 5 · see citing works
Structural Evolution and Copper‐Ion Release Behavior of Cu‐pHEMA Hybrids Synthesized In Situ
Liu, Y., Tung, T., Liu, K., et al. (2009) · Advanced Engineering Materials · doi:10.1002/adem.200900142 · Cited by 5 · see citing works
S-Nitrosothiols: Formation, Decomposition, Reactivity and Possible Physiological Effects
Morakinyo, M. K. (2010) · doi:10.15760/etd.100 · Cited by 2 · see citing works
Improving the Performance of Implantable Sensors with Nitric Oxide Release
Frost, M. C. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-809275-0.00008-9 · Cited by 3 · see citing works
Improving the hemocompatibility of catheters via NO release/generation
Wo, Y., Brisbois, E. J., Bartlett, R. H., & Meyerhoff, M. E. (2017) · Elsevier eBooks · doi:10.1016/b978-0-08-100497-5.00013-6 · Cited by 2 · see citing works
Self-citationMendhi, J. (2022) · Queensland University of Technology · doi:10.5204/thesis.eprints.227733 · Cited by 1 · see citing works
Progress in Sensor Biocompatibility
Córcoles, E. P., & Boutelle, M. G. (2013) · SpringerBriefs in applied sciences and technology · doi:10.1007/978-3-319-00360-3_4
Nitric Oxide‐Releasing Subcutaneous Glucose Sensors
Paul, H. S., & Schoenfisch, M. H. (2009) · Wiley eBooks · doi:10.1002/9780470567319.ch9 · Cited by 1 · see citing works
Khanna, V. K. (2015) · Springer eBooks · doi:10.1007/978-3-319-25448-7_13
Rana, M. M., & Siegler, H. D. L. H. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15684-7.00009-9
Khanna, V. K. (2026) · Springer eBooks · doi:10.1007/978-3-031-99868-3_13
Ismail, A. G. (2016) · doi:10.70675/d94f53bbzc8bcz447bz898fz2047b4ad9fea · Cited by 1 · see citing works
“developed NO-sensor polymeric materials containing immobilized metallic species (copper, selenium, tellurium) [292-295,430-433] aimed at decomposing RSNOs to NO.”
BackgroundTucker, A. D., Ozkan, E., Wilson, S. N., Shome, A., Handa, H., & Brisbois, E. J. (2026) · Journal of Materials Chemistry B · doi:10.1039/d6tb01036a
- Authors
- WU, Y., ROJAS, A., GRIFFITH, G., SKRZYPCHAK, A., LAFAYETTE, N., BARTLETT, R., & MEYERHOFF, M.
- Affiliations
- University of Michigan (US)
- Corresponding author
- MEYERHOFF, M
- ORCID
- MEYERHOFF, M
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2007-01-30
- Volume
- 121
- Issue
- 1
- Pages
- 36-46
- ISSN
- 0925-4005 (ISSN-L)
- PMC
- PMC1805711
- OpenAlex
- W4253581522
- Cited by
- 65
- References
- 0
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 2 · 2022: 1 · 2021: 5 · 2020: 3 · 2019: 2 · 2018: 2 · 2017: 5 · 2016: 4 · 2015: 6 · 2014: 4 · 2013: 4 · 2012: 2
- FWCI
- 2.87
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- Sensors and Actuators B Chemical (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- PubMed
- Funders
- National Institutes of Health
- National Institute of Biomedical Imaging and Bioengineering (R01EB004527, R01EB000783)
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (R01HD015434)
- Topics
- Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
- Keywords
- nitric oxide production, S-nitrosothiols, copper nanoparticles, hemocompatibility, polymer coatings, porcine arteries
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review