Highly stretchable potentiometric ion sensor based on surface strain redistributed fiber for sweat monitoring
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Development of stretchable potentiometric ion sensors has the observable potential for wearable devices to continuously monitoring of electrolytes in body fluids. However, the mechanical mismatch between soft elastomeric substrate and ion-selective electrode components greatly hinders sensor's fabrication and its stretching stability for long-term use. Here, we propose a new strategy to construct a potentiometric ion sensor on a surface strain redistributed elastic fiber (SSRE-fiber) with both high stretchability and high sensing stability. The SSRE-fiber is designed with a unique unilateral bead structure, which significantly changes its surface strain distribution during deformation. Benefit from this platform, the active sensing materials with high Young's modulus fabricated on the unilateral bead region can keep unchanged during stretching (0-200%). Thus, the as-prepared potentiometric sensors (ion-selective electrode and polymer/inorganic salt membrane-coated reference electrode) can perform with stable functions ignoring the stretching of the fiber. This new SSRE-fiber platform paves a way for the design of highly stretchable and stable electrochemical sensor capable of integrating into textiles for wearable biochemical detection applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Wearable Chemical Sensors: Present Challenges and Future Prospects
Bandodkar, A. J., Jeerapan, I., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00250 · Cited by 778
Accessing analytes in biofluids for peripheral biochemical monitoring
Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0040-3 · Cited by 758
Wearable Sensors for Biochemical Sweat Analysis
Bandodkar, A. J., Jeang, W. J., Ghaffari, R., & Rogers, J. A. (2019) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061318-114910 · Cited by 387
Abellán-Llobregat, A., Jeerapan, I., Bandodkar, A., Vidal, L., Canals, A., Wang, J., & Morallón, E. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.01.058 · Cited by 348
Bandodkar, A. J., Jeerapan, I., You, J.-M., Nuñez-Flores, R., & Wang, J. (2016) · Nano Letters · doi:10.1021/acs.nanolett.5b04549 · Cited by 341
Jin, Z.-H., Liu, Y.-L., Chen, J.-J., Cai, S.-L., Xu, J.-Q., & Huang, W.-H. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04616 · Cited by 116
Cited by
Porous Conductive Textiles for Wearable Electronics
Ding, Y., Jiang, J., Wu, Y., Zhang, Y., Zhou, J., Zhang, Y., Huang, Q., & Zheng, Z. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00507 · Cited by 269
Wearable Skin Sensors and Their Challenges: A Review of Transdermal, Optical, and Mechanical Sensors
Ahmad Tarar, A., Mohammad, U., & K. Srivastava, S. (2020) · Biosensors · doi:10.3390/bios10060056 · Cited by 119
Pillai, S., Upadhyay, A., Sayson, D., Nguyen, B. H., & Tran, S. D. (2021) · Molecules · doi:10.3390/molecules27010165 · Cited by 95
Recent Advances in Artificial Intelligence and Wearable Sensors in Healthcare Delivery
Junaid, S. B., Imam, A. A., Abdulkarim, M., Surakat, Y. A., Balogun, A. O., Kumar, G., Shuaibu, A. N., Garba, A., Sahalu, Y., Mohammed, A., et al. (2022) · Applied Sciences · doi:10.3390/app122010271 · Cited by 65
Metadata
- Authors
- Wang, S., Bai, Y., Yang, X., Liu, L., Li, L., Lu, Q., Li, T., & Zhang, T.
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2020-07
- Volume
- 214
- Pages
- 120869
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W3008865637
- Cited by
- 47
- References
- 10
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly stretchable potentiometric ion sensor based on surface strain redistributed fiber for sweat monitoring. https://app.cochat.ai/papers/10.1016/j.talanta.2020.120869
- The paper
- Wang, S., Bai, Y., Yang, X., Liu, L., Li, L., Lu, Q., Li, T., & Zhang, T. (2020). Highly stretchable potentiometric ion sensor based on surface strain redistributed fiber for sweat monitoring. Talanta. https://doi.org/10.1016/j.talanta.2020.120869
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.