Imaging Methods for Ultrasound Contrast Agents
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Microbubble contrast agents were introduced more than 25 years ago with the objective of enhancing blood echoes and enabling diagnostic ultrasound to image the microcirculation. Cardiology and oncology waited anxiously for the fulfillment of that objective with one clinical application each: myocardial perfusion, tumor perfusion and angiogenesis imaging. What was necessary though at first was the scientific understanding of microbubble behavior in vivo and the development of imaging technology to deliver the original objective. And indeed, for more than 25 years bubble science and imaging technology have evolved methodically to deliver contrast-enhanced ultrasound. Realization of the basic bubbles properties, non-linear response and ultrasound-induced destruction, has led to a plethora of methods; algorithms and techniques for contrast-enhanced ultrasound (CEUS) and imaging modes such as harmonic imaging, harmonic power Doppler, pulse inversion, amplitude modulation, maximum intensity projection and many others were invented, developed and validated. Today, CEUS is used everywhere in the world with clinical indications both in cardiology and in radiology, and it continues to mature and evolve and has become a basic clinical tool that transforms diagnostic ultrasound into a functional imaging modality. In this review article, we present and explain in detail bubble imaging methods and associated artifacts, perfusion quantification approaches, and implementation considerations and regulatory aspects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Leighton, T. G. (2012) · Cited by 2,284
Wei, K., Jayaweera, A. R., Firoozan, S., Linka, A., Skyba, D. M., & Kaul, S. (1998) · Circulation · doi:10.1161/01.cir.97.5.473 · Cited by 1,616
Ultrafast ultrasound localization microscopy for deep super-resolution vascular imaging
Errico, C., Pierre, J., Pezet, S., Desailly, Y., Lenkei, Z., Couture, O., & Tanter, M. (2015) · Nature · doi:10.1038/nature16066 · Cited by 1,349
Ultrafast imaging in biomedical ultrasound
Tanter, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2014.2882 · Cited by 1,151
Echocardiography of the Aortic Root
Gramiak, R., & Shah, P. M. (1968) · Investigative Radiology · doi:10.1097/00004424-196809000-00011 · Cited by 930
Gauging the likelihood of cavitation from short-pulse, low-duty cycle diagnostic ultrasound
Apfel, R. E., & Holland, C. K. (1991) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(91)90125-g · Cited by 690
Cavitation produced by Ultrasonics
Noltingk, B. E., & Neppiras, E. A. (1950) · Proceedings of the Physical Society. Section B · doi:10.1088/0370-1301/63/9/305 · Cited by 674
In Vivo Acoustic Super-Resolution and Super-Resolved Velocity Mapping Using Microbubbles
Christensen-Jeffries, K. M., Browning, R. J., Tang, M., Dunsby, C. W., & Eckersley, R. J. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2359650 · Cited by 489
Imaging Tumor Angiogenesis With Contrast Ultrasound and Microbubbles Targeted to α v β 3
Ellegala, D. B., Leong-Poi, H., Carpenter, J. E., Klibanov, A. L., Kaul, S., Shaffrey, M. E., Sklenar, J., & Lindner, J. R. (2003) · Circulation · doi:10.1161/01.cir.0000080326.15367.0c · Cited by 454
Ultrasound contrast imaging: current and new potential methods
Frinking, P. J. A., Bouakaz, A., Kirkhorn, J., Ten Cate, F. J., & de Jong, N. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00229-5 · Cited by 378
Dietrich, C., Averkiou, M., Correas, J.-M., Lassau, N., Leen, E., & Piscaglia, F. (2012) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0032-1313026 · Cited by 361
Self-citationPitfalls in MR measurement of tissue blood flow with intravascular tracers: Which mean transit time?
Weisskoff, R. M., Chesler, D., Boxerman, J. L., & Rosen, B. R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290420 · Cited by 335
Contrast Echocardiography: Current and Future Applications
Mulvagh, S. L., DeMaria, A. N., Feinstein, S. B., Burns, P. N., Kaul, S., Miller, J. G., Monaghan, M., Porter, T. R., Shaw, L. J., & Villanueva, F. S. (2000) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2000.105462 · Cited by 310
Self-citationSubharmonic imaging of contrast agents
Forsberg, F., Shi, W. T., & Goldberg, B. B. (2000) · Ultrasonics · doi:10.1016/s0041-624x(99)00148-1 · Cited by 303
Opacic, T., Dencks, S., Theek, B., Piepenbrock, M., Ackermann, D., Rix, A., Lammers, T., Stickeler, E., Delorme, S., Schmitz, G., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-03973-8 · Cited by 295
Second harmonic ultrasonic blood perfusion measurement
Schrope, B. A., & Newhouse, V. L. (1993) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(93)90080-8 · Cited by 246
Physicochemical Characteristics of Sonazoid™, A New Contrast Agent for Ultrasound Imaging
Sontum, P. C. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2007.11.006 · Cited by 244
Contrast–agent detection and quantification
(2004) · European Radiology Supplements · doi:10.1007/s10406-004-0075-4 · Cited by 203
Ultrasound contrast plane wave imaging
Couture, O., Fink, M., & Tanter, M. (2012) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2508 · Cited by 190
Simulated Capillary Blood Flow Measurement Using a Nonlinear Ultrasonic Contrast Agent
Schrope, B., Newhouse, V. L., & Uhlendorf, V. (1992) · Ultrasonic Imaging · doi:10.1177/016173469201400204 · Cited by 185
Quantitative evaluation of microvascular blood flow by contrast-enhanced ultrasound (CEUS)
Greis, C. (2011) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-2011-1464 · Cited by 183
Second harmonic imaging of an intravenously administered echocardiographic contrast agent
Mulvagh, S. L., Foley, D. A., Aeschbacher, B. C., Klarich, K. K., & Seward, J. B. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00619-2 · Cited by 141
Contrast-Ultrasound Diffusion Imaging for Localization of Prostate Cancer
Kuenen, M. P. J., Mischi, M., & Wijkstra, H. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2125981 · Cited by 140
Burns, Powers, Simpson, Brezina, Kolin, Chin, Uhlendorf, & Fritzsch (1994) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.1994.401886 · Cited by 122
Dynamic contrast enhanced ultrasound for therapy monitoring
Hudson, J. M., Williams, R., Tremblay‐Darveau, C., Sheeran, P. S., Milot, L. M., Bjarnason, G. A., & Burns, P. N. (2015) · European Journal of Radiology · doi:10.1016/j.ejrad.2015.05.013 · Cited by 73
Self-citationLeen, E. L. S., Averkiou, M. A., Arditi, M., Burns, P. N., Bokor, D., Gauthier, T. P., Kono, Y., & Lucidarme, O. (2012) · European Radiology · doi:10.1007/s00330-011-2373-2 · Cited by 68
Self-citationKrix, M., Kiessling, F. M., Vosseler, S., Farhan, N., Mueller, M. M., Böhlen, P., Fusenig, N. E., & Delorme, S. (2003) · PubMed · Cited by 66
Contrast-enhanced ultrasound to visualize hemodynamic changes after rodent spinal cord injury
Khaing, Z. Z., Cates, L. N., Dewees, D. M., Hannah, A. S., Mourad, P. D., Bruce, M. F., & Hofstetter, C. P. (2018) · Journal of Neurosurgery Spine · doi:10.3171/2018.1.spine171202 · Cited by 65
Self-citationTransit time kinetics in ordered and disordered vascular trees
Karshafian, R., Burns, P. N., & Henkelman, R. M. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/19/009 · Cited by 61
Self-citationTiemann, K., Pohl, C., Schlosser, T. W., Goenechea, J., Bruce, M., Veltmann, C., Kuntz‐Hehner, S., Bangard, M., & Becher, H. H. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00261-1 · Cited by 59
Self-citationWang, H., Kaneko, O. F., Tian, L., Hristov, D. H., & Willmann, J. K. (2015) · Investigative Radiology · doi:10.1097/rli.0000000000000128 · Cited by 55
Clinical applications of transpulmonary contrast echocardiography
Main, M. L., & Grayburn, P. A. (1999) · American Heart Journal · doi:10.1016/s0002-8703(99)70470-9 · Cited by 52
Kaffas, A. E., Sigrist, R. M. S., Fisher, G. A., Bachawal, S. V., Liau, J., Wang, H., Karanany, A., Durot, I., Rosenberg, J., Hristov, D. H., et al. (2017) · Theranostics · doi:10.7150/thno.20329 · Cited by 52
Quantitative Ultrasonic Detection of Parenchymal Structural Change in Diffuse Renal Disease
Garra, B. S., Insana, M. F., Sesterhenn, I. A., Hall, T. J., Wagner, R. F., ROTELLAR, C., Winchester, J. F., & Zeman, R. K. (1994) · Investigative Radiology · doi:10.1097/00004424-199402000-00002 · Cited by 44
Gas-Filled Lipid Bilayers as Ultrasound Contrast Agents
Unger, E. C., Shen, D., Fritz, T., KULIK, B., Lund, P. J., WU, G.-L., Yellowhair, D., Ramaswami, R., & Matsunaga, T. O. (1994) · Investigative Radiology · doi:10.1097/00004424-199406001-00044 · Cited by 43
Hudson, J. M., Williams, R., Lloyd, B., Atri, M., Kim, T. K., Bjarnason, G. A., & Burns, P. N. (2011) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2011.04.001 · Cited by 37
Self-citation
Cited by
Fundamentals and applications of nanobubbles: A review
Foudas, A. W., Kosheleva, R. I., Favvas, E. P., Kostoglou, M., Mitropoulos, A. C., & Kyzas, G. Z. (2023) · Chemical Engineering Research and Design · doi:10.1016/j.cherd.2022.11.013 · Cited by 165
Qi, W., Zhao, J., Huang, C., Jiang, N., Li, J., Wu, C., Zhang, S., Hu, C., Xu, D., Wang, Q., et al. (2022) · Arthritis Research & Therapy · doi:10.1186/s13075-022-02814-w · Cited by 32
Metadata
- Authors
- Averkiou, M. A., Bruce, M. F., Powers, J. E., Sheeran, P. S., & Burns, P. N.
- Venue
- Ultrasound in Medicine & Biology
- Publisher
- Elsevier BV
- Published
- 2020-03
- Volume
- 46
- Issue
- 3
- Pages
- 498-517
- ISSN
- 0301-5629 (ISSN-L)
- OpenAlex
- W2992332278
- Cited by
- 172
- References
- 37
- FWCI
- 5.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.