Molecular Dynamics in Living Cells Observed by Fluorescence Correlation Spectroscopy with One- and Two-Photon Excitation
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
Multiphoton excitation (MPE) of fluorescent probes has become an attractive alternative in biological applications of laser scanning microscopy because many problems encountered in spectroscopic measurements of living tissue such as light scattering, autofluorescence, and photodamage can be reduced. The present study investigates the characteristics of two-photon excitation (2PE) in comparison with confocal one-photon excitation (1PE) for intracellular applications of fluorescence correlation spectroscopy (FCS). FCS is an attractive method of measuring molecular concentrations, mobility parameters, chemical kinetics, and fluorescence photophysics. Several FCS applications in mammalian and plant cells are outlined, to illustrate the capabilities of both 1PE and 2PE. Photophysical properties of fluorophores required for quantitative FCS in tissues are analyzed. Measurements in live cells and on cell membranes are feasible with reasonable signal-to-noise ratios, even with fluorophore concentrations as low as the single-molecule level in the sampling volume. Molecular mobilities can be measured over a wide range of characteristic time constants from approximately 10(-3) to 10(3) ms. While both excitation alternatives work well for intracellular FCS in thin preparations, 2PE can substantially improve signal quality in turbid preparations like plant cells and deep cell layers in tissue. At comparable signal levels, 2PE minimizes photobleaching in spatially restrictive cellular compartments, thereby preserving long-term signal acquisition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Self-citationTsien, R. Y. (1998) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.67.1.509 · Cited by 6,143
Handbook of fluorescent probes and research chemicals
Haugland, R. P. (1996) · Medical Entomology and Zoology · Cited by 2,793
Thermodynamic Fluctuations in a Reacting System—Measurement by Fluorescence Correlation Spectroscopy
Magde, D., Elson, E., & Webb, W. W. (1972) · Physical Review Letters · doi:10.1103/physrevlett.29.705 · Cited by 1,753
Self-citationTopics in Fluorescence Spectroscopy
(2003) · Topics in Fluorescence Spectroscopy · doi:10.1007/0-306-47947-8 · Cited by 1,578
Fluorescence correlation spectroscopy. II. An experimental realization
Magde, D., Elson, E. L., & Webb, W. W. (1974) · Biopolymers · doi:10.1002/bip.1974.360130103 · Cited by 1,512
Self-citationFluorescence correlation spectroscopy. I. Conceptual basis and theory
Elson, E. L., & Magde, D. (1974) · Biopolymers · doi:10.1002/bip.1974.360130102 · Cited by 1,436
Multiphoton fluorescence excitation: new spectral windows for biological nonlinear microscopy.
Xu, C., Zipfel, W., Shear, J. B., Williams, R. M., & Webb, W. W. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.20.10763 · Cited by 1,165
Self-citationRigler, R., Mets, �., Widengren, J., & Kask, P. (1993) · European Biophysics Journal · doi:10.1007/bf00185777 · Cited by 1,002
Sorting single molecules: application to diagnostics and evolutionary biotechnology.
Eigen, M., & Rigler, R. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.13.5740 · Cited by 956
Schwille, P., Meyer-Almes, F. J., & Rigler, R. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78833-7 · Cited by 817
Self-citationWidengren, J., Mets, U., & Rigler, R. (1995) · The Journal of Physical Chemistry · doi:10.1021/j100036a009 · Cited by 759
Swaminathan, R., Hoang, C. P., & Verkman, A. S. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78835-0 · Cited by 624
Topics in Fluorescence Spectroscopy: Principles
(2002) · Springer eBooks · doi:10.1007/b112907 · Cited by 589
Exchange of Protein Molecules Through Connections Between Higher Plant Plastids
Köhler, R. H., Cao, J., Zipfel, W. R., Webb, W. W., & Hanson, M. R. (1997) · Science · doi:10.1126/science.276.5321.2039 · Cited by 582
Self-citationHaupts, U., Maiti, S., Schwille, P., & Webb, W. W. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.23.13573 · Cited by 554
Self-citationKinetics of conformational fluctuations in DNA hairpin-loops
Bonnet, G., Krichevsky, O., & Libchaber, A. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.15.8602 · Cited by 537
Berland, K. M., So, P. T., & Gratton, E. (1995) · Biophysical Journal · doi:10.1016/s0006-3495(95)80230-4 · Cited by 490
Fluorescence correlation spectroscopy with single-molecule sensitivity on cell and model membranes
Schwille, P., Korlach, J., & Webb, W. W. (1999) · Cytometry · doi:10.1002/(sici)1097-0320(19990701)36:3<176::aid-cyto5>3.0.co;2-f · Cited by 487
Self-citationDynamics of fluorescence marker concentration as a probe of mobility
Koppel, D. E., Axelrod, D., Schlessinger, J., Elson, E. L., & Webb, W. W. (1976) · Biophysical Journal · doi:10.1016/s0006-3495(76)85776-1 · Cited by 481
Self-citationConstrained diffusion or immobile fraction on cell surfaces: a new interpretation
Feder, T. J., Brust-Mascher, I., Slattery, J. P., Baird, B., & Webb, W. W. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79846-6 · Cited by 474
Self-citationStatistical accuracy in fluorescence correlation spectroscopy
Koppel, D. E. (1974) · Physical Review A · doi:10.1103/physreva.10.1938 · Cited by 450
Petersen, N. O., Höddelius, P., Wiseman, P. W., Seger, O., & Magnusson, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81173-1 · Cited by 443
Fluorescence correlation spectroscopy as a probe of molecular dynamics
Aragón, S. R., & Pecora, R. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432357 · Cited by 329
Ghosh, R. N., & Webb, W. W. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80939-7 · Cited by 321
Self-citationFluorescence correlation spectroscopy: Diagnostics for sparse molecules
Maiti, S., Haupts, U., & Webb, W. W. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.22.11753 · Cited by 317
Self-citationReal-time enzyme kinetics monitored by dual-color fluorescence cross-correlation spectroscopy
Kettling, U., Koltermann, A., Schwille, P., & Eigen, M. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.4.1416 · Cited by 308
Self-citationFluorescence correlation spectroscopy. III. Uniform translation and laminar flow
Magde, D., Webb, W. W., & Elson, E. L. (1978) · Biopolymers · doi:10.1002/bip.1978.360170208 · Cited by 298
Self-citationPolitz, J. C., Browne, E. S., Wolf, D. E., & Pederson, T. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.11.6043 · Cited by 275
Williams, R. M., Piston, D. W., & Webb, W. W. (1994) · The FASEB Journal · doi:10.1096/fasebj.8.11.8070629 · Cited by 235
Self-citationSingle-molecule detection by two-photon-excited fluorescence
Mertz, J., Xu, C., & Webb, W. W. (1995) · Optics Letters · doi:10.1364/ol.20.002532 · Cited by 225
Self-citationAnalysis of confocal laser-microscope optics for 3-D fluorescence correlation spectroscopy
Qian, H., & Elson, E. L. (1991) · Applied Optics · doi:10.1364/ao.30.001185 · Cited by 192
Imaging in high-aperture optical systems
Sheppard, C. J. R., & Matthews, H. J. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.001354 · Cited by 184
Scanning fluorescence correlation spectroscopy. I. Theory and simulation of aggregation measurements
Petersen, N. O. (1986) · Biophysical Journal · doi:10.1016/s0006-3495(86)83709-2 · Cited by 175
Schwille, P., Bieschke, J., & Oehlenschläger, F. (1997) · Biophysical Chemistry · doi:10.1016/s0301-4622(97)00061-6 · Cited by 169
Self-citationPalmer, A. G., & Thompson, N. L. (1987) · Biophysical Journal · doi:10.1016/s0006-3495(87)83213-7 · Cited by 159
Submillisecond detection of single rhodamine molecules in water
Mets, Ü., & Rigler, R. W. (1994) · Journal of Fluorescence · doi:10.1007/bf01878461 · Cited by 155
Koltermann, A., Kettling, U., Bieschke, J., Winkler, T., & Eigen, M. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.4.1421 · Cited by 155
Schwille, P., Oehlenschläger, F., & Walter, N. G. (1996) · Biochemistry · doi:10.1021/bi960517g · Cited by 150
Self-citationRoom-Temperature Fluorescence Imaging and Spectroscopy of Single Molecules by Two-Photon Excitation
Sánchez, E. J., Novotný, L., Holtom, G. R., & Xie, X. S. (1997) · The Journal of Physical Chemistry A · doi:10.1021/jp971915b · Cited by 138
On the statistics of fluorescence correlation spectroscopy
Qian, H. (1990) · Biophysical Chemistry · doi:10.1016/0301-4622(90)80039-a · Cited by 135
Statistical accuracy in fluorescence fluctuation experiments
Kask, P., Günther, R., & Axhausen, P. (1997) · European Biophysics Journal · doi:10.1007/s002490050028 · Cited by 117
Sandison, D. R., Piston, D. W., Williams, R. M., & Webb, W. W. (1995) · Applied Optics · doi:10.1364/ao.34.003576 · Cited by 89
Self-citationImaging fluorescence correlation spectroscopy: nonuniform IgE distributions on planar membranes
Huang, Z., & Thompson, N. L. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79766-7 · Cited by 42
Cited by
Nonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,893
Self-citationMultiphoton microscopy in life sciences
König, K. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00738.x · Cited by 1,265
“Furthermore, single molecule detection with two-photon fluorescence correlation q 2000 The Royal Microscopical Society, Journal of Microscopy, 200, 83±104 spectroscopy has been demonstrated (So et al., 1998; Schwille et al., 1999).”
MethodAnomalous transport in the crowded world of biological cells
Höfling, F., & Franosch, T. (2013) · Reports on Progress in Physics · doi:10.1088/0034-4885/76/4/046602 · Cited by 1,247
Optimization of a GCaMP Calcium Indicator for Neural Activity Imaging
Akerboom, J., Chen, T.-W., Wardill, T. J., Tian, L., Marvin, J. S., Mutlu, S., Calderón, N. C., Esposti, F., Borghuis, B. G., Sun, X. R., et al. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.2601-12.2012 · Cited by 1,223
Light Microscopy Techniques for Live Cell Imaging
Stephens, D. J., & Allan, V. J. (2003) · Science · doi:10.1126/science.1082160 · Cited by 1,179
Metadata
- Authors
- Schwille, P., Haupts, U., Maiti, S., & Webb, W. W.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1999-10
- Volume
- 77
- Issue
- 4
- Pages
- 2251-2265
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2027429271
- Cited by
- 722
- References
- 44
- FWCI
- 18.40
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.