Evaluation of quadrupole time-of-flight tandem mass spectrometry and ion-trap multiple-stage mass spectrometry for the differentiation of C-glycosidic flavonoid isomers
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
LC-MS-MS is becoming a very important tool for the on-line identification of natural products in crude plant extracts. For an efficient use of this technique in the dereplication of natural products, a careful study of the parameters used to generate informative MS-MS spectra is needed. In this paper, the collision-induced dissociation (CID) MS-MS spectra of ubiquitous C-glycosidic flavonoids have been systematically studied using hybrid quadrupole time-of-flight and ion-trap (IT) mass analysers under various CID energy conditions. Efficient differentiation of flavonoid C-glycoside isomers was possible, based on the comparison of CID-MS-MS spectra of particular C-glycoside unit fragments. Striking differences between 6-C and 8-C flavonoid glycosides were especially observed in the product ion spectra of their 0.2X+ fragments ([M+H-120]+). Some guidelines for the on-line characterisation of C-glycosidic flavonoids by LC-MS-MS or LC-multiple-stage MS are given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A systematic nomenclature for carbohydrate fragmentations in FAB-MS/MS spectra of glycoconjugates
Domon, B., & Costello, C. E. (1988) · Glycoconjugate Journal · doi:10.1007/bf01049915 · Cited by 2,729
Electrospray interface for liquid chromatographs and mass spectrometers
Whitehouse, C. M., Dreyer, R. N., Yamashita, M., & Fenn, J. B. (1985) · Analytical Chemistry · doi:10.1021/ac00280a023 · Cited by 1,512
Electrospray ionization mass spectrometry : fundamentals, instrumentation, and applications
Cole, R. B. (1997) · Wiley eBooks · Cited by 1,140
Justesen, U., Knuthsen, P., & Leth, T. (1998) · Journal of Chromatography A · doi:10.1016/s0021-9673(97)01061-3 · Cited by 552
The flavonoids. Advances in research since 1980
(1989) · International Journal of Biochemistry · doi:10.1016/0020-711x(89)90299-1 · Cited by 526
Ma, Y. L., Li, Q. M., Van den Heuvel, H., & Claeys, M. (1997) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(199708)11:12<1357::aid-rcm983>3.0.co;2-9 · Cited by 401
The flavonoids, advances in research since 1980
Grisebach, H. (1989) · Trends in Biochemical Sciences · doi:10.1016/0968-0004(89)90037-6 · Cited by 332
Stevens, J. F., Taylor, A. W., & Deinzer, M. L. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(98)01001-2 · Cited by 318
Justesen, U. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00861-x · Cited by 245
Liquid chromatograph—mass spectrometer—computer analytical systems
Horning, E. C., Carroll, D. I., Dzidic, I., Haegele, K. D., Horning, M. G., & Stillwell, R. N. (1974) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)90841-0 · Cited by 207
Cited by
Mass spectrometry in the structural analysis of flavonoids
Cuyckens, F., & Claeys, M. (2004) · Journal of Mass Spectrometry · doi:10.1002/jms.585 · Cited by 1,081
Analytical separation and detection methods for flavonoids
de Rijke, E., Out, P., Niessen, W. M. A., Ariese, F., Gooijer, C., & Brinkman, U. A. T. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.01.019 · Cited by 692
Mass spectrometry in metabolome analysis
Villas‐Bôas, S. G., Mas, S., Åkesson, M., Smedsgaard, J., & Nielsen, J. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20032 · Cited by 616
Characterization and Quantitation of Antioxidant Constituents of Sweet Pepper (Capsicum annuum L.)
Marín, A., Ferreres, F., Tomás-Barberán, F. A., & Gil, M. I. (2004) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf0497915 · Cited by 524
Sánchez‐Rabaneda, F., Jáuregui, O., Casals, I., Andrés‐Lacueva, C., Izquierdo‐Pulido, M., & Lamuela‐Raventós, R. M. (2003) · Journal of Mass Spectrometry · doi:10.1002/jms.395 · Cited by 472
Analysis of phenolic acids and flavonoids in honey
Pyrzynska, K., & Biesaga, M. (2009) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.03.015 · Cited by 361
Structural characterization of flavonoid glycosides by multi‐stage mass spectrometry
Vukics, V., & Guttman, A. (2010) · Mass Spectrometry Reviews · doi:10.1002/mas.20212 · Cited by 337
Wolfender, J.-L., Nuzillard, J.-M., van der Hooft, J. J. J., Renault, J.-H., & Bertrand, S. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05112 · Cited by 305
Self-citationFerreres, F., Silva, B. M., Andrade, P. B., Seabra, R. M., & Ferreira, M. A. (2003) · Phytochemical Analysis · doi:10.1002/pca.727 · Cited by 302
Tsang, C., Auger, C., Mullen, W., Bornet, A., Rouanet, J.-M., Crozier, A., & Teissedre, P.-L. (2005) · British Journal of Nutrition · doi:10.1079/bjn20051480 · Cited by 298
Zou, Y., Chang, S. K. C., Gu, Y., & Qian, S. Y. (2011) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf104640k · Cited by 284
Hubert, J., Nuzillard, J.-M., & Renault, J.-H. (2017) · Phytochemistry Reviews · doi:10.1007/s11101-015-9448-7 · Cited by 273
Dereplication: racing to speed up the natural products discovery process
Gaudêncio, S. P., & Pereira, F. (2015) · Natural Product Reports · doi:10.1039/c4np00134f · Cited by 264
Abad-García, B., Berrueta, L. A., Garmón-Lobato, S., Gallo, B., & Vicente, F. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.05.039 · Cited by 260
The Flavonoid Glycosides and Procyanidin Composition of Deglet Noor Dates (Phoenix dactylifera)
Hong, Y. J., Tomas-Barberan, F. A., Kader, A. A., & Mitchell, A. E. (2006) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf0581776 · Cited by 257
Flavonoids of Zizyphus jujuba L. and Zizyphus spina-christi (L.) Willd (Rhamnaceae) fruits
Pawlowska, A. M., Camangi, F., Bader, A., & Braca, A. (2009) · Food Chemistry · doi:10.1016/j.foodchem.2008.06.053 · Cited by 239
Schütz, K., Kammerer, D. R., Carle, R., & Schieber, A. (2005) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1767 · Cited by 239
Papagiannopoulos, M., Wollseifen, H. R., Mellenthin, A., Haber, B., & Galensa, R. (2004) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf030660y · Cited by 237
Koolen, H. H. F., da Silva, F. M. A., Gozzo, F. C., de Souza, A. Q. L., & de Souza, A. D. L. (2013) · Food Research International · doi:10.1016/j.foodres.2013.01.039 · Cited by 236
“17 min (FE) displayed precursor masses m/z 431 and 445, the product ion spectra displayed for both presented similar fragmentation pattern, which differs on an initial methyl loss (15 Da), the precursor masses and the product ions are in concordance with the flavonoid C-glucosides structures of vitexin and scoparin re…”
BackgroundSchieber, A., Berardini, N., & Carle, R. (2003) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf030218f · Cited by 235
Recent advances and trends in the liquid-chromatography–mass spectrometry analysis of flavonoids
de Villiers, A., Venter, P., & Pasch, H. (2016) · Journal of Chromatography A · doi:10.1016/j.chroma.2015.11.077 · Cited by 228
Current and emerging mass-spectrometry technologies for metabolomics
Bedair, M., & Sumner, L. W. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2008.01.006 · Cited by 225
HPLC in Natural Product Analysis: The Detection Issue
Wolfender, J.-L. (2009) · Planta Medica · doi:10.1055/s-0028-1088393 · Cited by 199
“Furthermore, even if libraries of NP spectra could be efficiently generated on a given LC-hyphenated system, their widespread use is complicated by the fact that, contrary to GC-MS, most of the data, especially HPLC-MS and HPLC-MS-MS, are instrument dependant [120].”
Self-citationBerardini, N., Carle, R., & Schieber, A. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1611 · Cited by 185
Qiao, X., Li, R., Song, W., Miao, W.-J., Liu, J., Chen, H.-B., Guo, D.-A., & Ye, M. (2016) · Journal of Chromatography A · doi:10.1016/j.chroma.2016.02.079 · Cited by 184
Prasain, J. K., Jones, K., Kirk, M., Wilson, L., Smith-Johnson, M., Weaver, C., & Barnes, S. (2003) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf030174a · Cited by 182
Taamalli, A., Arráez‐Román, D., Abaza, L., Iswaldi, I., Fernández‐Gutiérrez, A., Zarrouk, M., & Segura‐Carretero, A. (2015) · Phytochemical Analysis · doi:10.1002/pca.2566 · Cited by 177
Benayad, Z., Gómez-Cordovés, C., & Es-Safi, N. (2014) · International Journal of Molecular Sciences · doi:10.3390/ijms151120668 · Cited by 169
“The second group consisted of flavone O,C-glycosides with an acyl moiety on the C-glycosyl due to the presence of losses corresponding to the fragmentations −Zj (acyl − 18), X0, X0 [35,36,45].”
Han, J., Ye, M., Qiao, X., Xu, M., Wang, B.-R., & Guo, D.-A. (2008) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2008.02.013 · Cited by 165
Hybrid Search: A Method for Identifying Metabolites Absent from Tandem Mass Spectrometry Libraries
Cooper, B. T., Yan, X., Simón-Manso, Y., Tchekhovskoi, D. V., Mirokhin, Y. A., & Stein, S. E. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03415 · Cited by 69
Pandey, R., & Kumar, B. (2016) · Journal of Liquid Chromatography & Related Technologies · doi:10.1080/10826076.2016.1148048 · Cited by 68
“Isovitexin produced base peak ion at m/z 283.0594 [MþH-150]þ 232 R. PANDEY AND B. KUMAR (0,1Xþ), while vitexin at m/z 313.0707 [MþH-120]þ (0,2Xþ) at CID energy of 20 eV as reported by Waridel et al.[54](Figure 3).”
BackgroundMethodInfluential
Metadata
- Authors
- Waridel, P., Wolfender, J.-L., Ndjoko, K., Hobby, K. R., Major, H. J., & Hostettmann, K.
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 2001-08
- Volume
- 926
- Issue
- 1
- Pages
- 29-41
- ISSN
- 0021-9673 (ISSN-L)
- OpenAlex
- W1967677446
- Cited by
- 309
- References
- 22
- FWCI
- 6.50
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.