Polymer microfluidic devices
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
(2014) · doi:10.1201/b17118 · Cited by 57,706
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip
Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., & Manz, A. (1993) · Science · doi:10.1126/science.261.5123.895 · Cited by 1,800
A Sequencing Method Based on Real-Time Pyrophosphate
Ronaghi, M., Uhlén, M., & Nyrén, P. (1998) · Science · doi:10.1126/science.281.5375.363 · Cited by 1,630
Manz, A., Harrison, D. J., Verpoorte, E. M. J., Fettinger, J. C., Paulus, A., Lüdi, H., & Widmer, H. M. (1992) · Journal of Chromatography A · doi:10.1016/0021-9673(92)80293-4 · Cited by 1,042
Woolley, A. T., Hadley, D., Landre, P., deMello, A. J., Mathies, R. A., & Northrup, M. A. (1996) · Analytical Chemistry · doi:10.1021/ac960718q · Cited by 730
Anderson, J. R., Chiu, D. T., Jackman, R. J., Cherniavskaya, O., McDonald, J. C., Wu, H., Whitesides, S. H., & Whitesides, G. M. (2000) · Analytical Chemistry · doi:10.1021/ac9912294 · Cited by 698
Patterned Delivery of Immunoglobulins to Surfaces Using Microfluidic Networks
Delamarche, E., Bernard, A., Schmid, H., Michel, B., & Biebuyck, H. (1997) · Science · doi:10.1126/science.276.5313.779 · Cited by 678
Effenhauser, C. S., Bruin, G. J. M., Paulus, A., & Ehrat, M. (1997) · Analytical Chemistry · doi:10.1021/ac9703919 · Cited by 640
Quantitative Analysis of Molecular Interaction in a Microfluidic Channel: The T-Sensor
Kamholz, A. E., Weigl, B. H., Finlayson, B. A., & Yager, P. (1999) · Analytical Chemistry · doi:10.1021/ac990504j · Cited by 631
Fabrication of Plastic Microfluid Channels by Imprinting Methods
Martynova, L., Locascio, L. E., Gaitan, M., Kramer, G. W., Christensen, R. G., & MacCrehan, W. A. (1997) · Analytical Chemistry · doi:10.1021/ac970558y · Cited by 533
Microfluidic Diffusion-Based Separation and Detection
Weigl, B. H., & Yager, P. (1999) · Science · doi:10.1126/science.283.5400.346 · Cited by 502
UV Laser Machined Polymer Substrates for the Development of Microdiagnostic Systems
Roberts, M. A., Rossier, J. S., Bercier, P., & Girault, H. (1997) · Analytical Chemistry · doi:10.1021/ac961038q · Cited by 497
Microfluidic Networks for Chemical Patterning of Substrates: Design and Application to Bioassays
Delamarche, E., Bernard, A., Schmid, H., Bietsch, A., Michel, B., & Biebuyck, H. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973071f · Cited by 412
Multichannel Microchip Electrospray Mass Spectrometry
Xue, Q., Foret, F., Dunayevskiy, Y. M., Zavracky, P. M., McGruer, N. E., & Karger, B. L. (1997) · Analytical Chemistry · doi:10.1021/ac9607119 · Cited by 341
Surface Modification of Poly(methyl methacrylate) Used in the Fabrication of Microanalytical Devices
Henry, A. C., Tutt, T. J., Galloway, M., Davidson, Y. Y., McWhorter, C. S., Soper, S. A., & McCarley, R. L. (2000) · Analytical Chemistry · doi:10.1021/ac000685l · Cited by 319
(1991) · ACS Symposium Series · doi:10.1021/bk-1991-0475 · Cited by 317
Jackman, R. J., Duffy, D. C., Ostuni, E., Willmore, N. D., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac971295a · Cited by 304
Irradiation effects on polymers
Clegg, D., & Collyer, A. A. (1991) · CERN Document Server (European Organization for Nuclear Research) · Cited by 298
Locascio, L. E., Perso, C. E., & Lee, C. S. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)00774-8 · Cited by 192
Control of Flow Direction in Microfluidic Devices with Polyelectrolyte Multilayers
Barker, S. L. R., Ross, D., Tarlov, M. J., Gaitan, M., & Locascio, L. E. (2000) · Analytical Chemistry · doi:10.1021/ac0008690 · Cited by 185
Microfabricated isoelectric focusing device for direct electrospray ionization-mass spectrometry
Wen, J., Lin, Y., Xiang, F., Matson, D. W., Udseth, H. R., & Smith, R. D. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<191::aid-elps191>3.0.co;2-m · Cited by 181
Design and Fabrication of Topologically Complex, Three-Dimensional Microstructures
Jackman, R. J., Brittain, S. T., Adams, A., Prentiss, M. G., & Whitesides, G. M. (1998) · Science · doi:10.1126/science.280.5372.2089 · Cited by 168
A Microfabricated Dialysis Device for Sample Cleanup in Electrospray Ionization Mass Spectrometry
Xu, N., Lin, Y., Hofstadler, S. A., Matson, D. W., Call, C. J., & Smith, R. D. (1998) · Analytical Chemistry · doi:10.1021/ac980233x · Cited by 150
Advances in Integrated Genetic Analysis
Anderson, R. C., Bogdan, G. J., Puski, A., & Su, X. (1998) · Springer eBooks · doi:10.1007/978-94-011-5286-0_3 · Cited by 15
Analytical Devices Based on Transverse Transport in Microchannels
Yager, P., Cabrera, C. R., Hatch, A. V., Hawkins, K. R., Holl, M. R., Kamholz, A. E., Macounová, K. M., & Weigl, B. H. (2000) · Springer eBooks · doi:10.1007/978-94-017-2264-3_3 · Cited by 4
Cited by
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
PDMS absorption of small molecules and consequences in microfluidic applications
Toepke, M. W., & Beebe, D. J. (2006) · Lab on a Chip · doi:10.1039/b612140c · Cited by 1,190
Commercialization of microfluidic point-of-care diagnostic devices
Chin, C. D., Linder, V., & Sia, S. K. (2012) · Lab on a Chip · doi:10.1039/c2lc21204h · Cited by 1,124
The upcoming 3D-printing revolution in microfluidics
Bhattacharjee, N., Urrios, A., Kang, S., & Folch, A. (2016) · Lab on a Chip · doi:10.1039/c6lc00163g · Cited by 1,123
Metadata
- Authors
- Becker, H.
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2002-02-11
- Volume
- 56
- Issue
- 2
- Pages
- 267-287
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W1965847387
- Cited by
- 1,187
- References
- 27
- FWCI
- 46.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.