A neural interface for a cortical vision prosthesis
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
The development of a cortically based vision prosthesis has been hampered by a lack of basic experiments on phosphene psychophysics. This basic research has been hampered by the lack of a means to safely stimulate large numbers of cortical neurons. Recently, a number of laboratories have developed arrays of silicon microelectrodes that could enable such basic studies on phosphene psychophysics. This paper describes one such array, the Utah electrode array, and summarizes neurosurgical, physiological and histological experiments that suggest that such an array could be implanted safely in visual cortex. We also summarize a series of chronic behavioral experiments that show that modest levels of electrical currents passed into cortex via this array can evoke sensory percepts. Pending the successful outcome of biocompatibility studies using such arrays, high count arrays of penetrating microelectrodes similar to this design could provide a useful tool for studies of the psychophysics of phosphene perception in human volunteers. Such studies could provide a proof-of-concept for cortically based artificial vision.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Taussig, M. (2012) · Routledge eBooks · doi:10.4324/9780203397244 · Cited by 2,532
Penfield, W. G. (1950) · Digital Commons - RU (Rockefeller University) · Cited by 1,387
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170 · cited 4×
“The research performed by Brindley (Brindley & Lewin, 1968) and Dobelle (Dobelle & Mladejovsky, 1974), and more recently by Schmidt et al. (Schmidt et al., 1996) have provided us with a basic understanding of the psychophysics of single phosphenes: their perceptual aspects, the currents required to evoke them, and, to…”
BackgroundMethodInfluentialSchmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672 · cited 11×
“Silicon is highly biocompatible (Stensaas & Stensaas, 1978; Yuen et al., 1987; Schmidt et al., 1993), can be micromachined using standard microfabrication technologies, and can incorporate integrated electronics .”
BackgroundMethodInfluentialFactors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 479
Dobelle, W. H., & Mladejovsky, M. G. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010766 · Cited by 468
Veraart, C., Raftopoulos, C., Mortimer, J. T., Delbeke, J., Pins, D., Michaux, G., Vanlierde, A., Parrini, S., & Wanet-Defalque, M.-C. (1998) · Brain Research · doi:10.1016/s0006-8993(98)00977-9 · Cited by 405
A three-dimensional microelectrode array for chronic neural recording
Hoogerwerf, A. C., & Wise, K. D. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.335862 · Cited by 371
Single unit recording capabilities of a 100 microelectrode array
Nordhausen, C. T., Maynard, E. M., & Normann, R. A. (1996) · Brain Research · doi:10.1016/0006-8993(96)00321-6 · Cited by 358
Self-citationA glass/silicon composite intracortical electrode array
Jones, K. E., Campbell, P. K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368134 · Cited by 354
Self-citationNeural prostheses : fundamental studies
Agnew, W. F., & McCreery, D. B. (1990) · Medical Entomology and Zoology · Cited by 316
Microfabrication Techniques for Integrated Sensors and Microsystems
Wise, K. D., & Najafi, K. (1991) · Science · doi:10.1126/science.1962192 · Cited by 309
A method for pneumatically inserting an array of penetrating electrodes into cortical tissue
Rousche, P. J., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368133 · Cited by 306
Self-citationLearning Retina Implants with Epiretinal Contacts
Eckmiller, R. (1997) · Ophthalmic Research · doi:10.1159/000268026 · Cited by 257
Subretinal electrical stimulation of the rabbit retina
Chow, A. Y., & Chow, V. Y. (1997) · Neuroscience Letters · doi:10.1016/s0304-3940(97)00185-7 · Cited by 242
Mobility performance with a pixelized vision system.
Cha, K., Horch, K. W., & Normann, R. A. (1992) · Vision Research · doi:10.1016/0042-6989(92)90229-c · Cited by 226 · cited 1×
“In a series of psychophysical experiments conducted with a portable simulator of pixelized images, we suggest that a functional visual sense might be restored in those with profound blindness with arrays containing as few as 625 electrodes (Cha et al., 1992a, b,c).”
BackgroundThe Development of Subretinal Microphotodiodes for Replacement of Degenerated Photoreceptors
Zrenner, E., Miliczek, K.-D., Gabel, V. P., Graf, H. G., Guenther, E., Haemmerle, H., Hoefflinger, B., Kohler, K., Nisch, W., Schubert, M., et al. (1997) · Ophthalmic Research · doi:10.1159/000268025 · Cited by 214
Simulation of a phosphene-based visual field: Visual acuity in a pixelized vision system
Cha, K., Horch, K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368135 · Cited by 198
Self-citationRousche, P. J., & Normann, R. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.750552 · Cited by 187 · cited 1×
“In order to determine the levels of current injections via the UEA that are required to evoke sensory percepts, we have conducted a series of behavioral experiments in cats (Rousche & Normann, 1999).”
MethodSelf-citationBiocompatibility of silicon‐based electrode arrays implanted in feline cortical tissue
Schmidt, S., Horch, K., & Normann, R. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820271106 · Cited by 183
Self-citationHistopathological evaluation of materials implanted in the cerebral cortex
Stensaas, S. S., & Stensaas, L. J. (1978) · Acta Neuropathologica · doi:10.1007/bf00689766 · Cited by 176
Wyatt, J., & Rizzo, J. (1996) · IEEE Spectrum · doi:10.1109/6.490056 · Cited by 175
An implantable CMOS circuit interface for multiplexed microelectrode recording arrays
Ji, J., & Wise, K. D. (1992) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.121568 · Cited by 173
Reading speed with a pixelized vision system
Cha, K., Boman, D. K., Horch, K. W., & Normann, R. A. (1992) · Journal of the Optical Society of America A · doi:10.1364/josaa.9.000673 · Cited by 167
Self-citationKewley, D. T., Hills, M. D., Borkholder, D. A., Opris, I. E., Maluf, N. I., Storment, C. W., Bower, J. M., & Kovacs, G. T. A. (1997) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(97)80221-x · Cited by 131
Tissue response to potential neuroprosthetic materials implanted subdurally
Yuen, T. G. H., Agnew, W. F., & Bullara, L. A. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90103-7 · Cited by 91
McCreery, D. B., Yuen, T. G. H., Agnew, W. F., & Bullara, L. A. (1994) · Hearing Research · doi:10.1016/0378-5955(94)90258-5 · Cited by 80 · cited 4×
“Schmidt et al. (1996) has demonstrated that safe levels of currents (McCreery et al., 1994) can evoke individual phosphenes when delivered via electrodes that penetrate the cortex.”
BackgroundInfluentialAn advanced demultiplexing system for physiological stimulation
Jones, K. E., & Normann, R. A. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.649992 · Cited by 60
Self-citationHumayun, M. S., Sato, Y., Propst, R., & de Juan, E. (1995) · PubMed · Cited by 41
Research works printed but not linked: 1
- Jones, K. E., & Normann, R. A. (1998). Demultiplexing of an intracortical electrode array: circuitry and interconnect techniques. Annals of Biomedical Engineering, (in press).
Cited by
A sensorimotor account of vision and visual consciousness
O'Regan, J. K., & Noë, A. (2001) · Behavioral and Brain Sciences · doi:10.1017/s0140525x01000115 · Cited by 3,126
Microneedles for drug and vaccine delivery
Kim, Y.-C., Park, J.-H., & Prausnitz, M. R. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.04.005 · Cited by 1,760
Modelling and analysis of local field potentials for studying the function of cortical circuits
Einevoll, G. T., Kayser, C., Logothetis, N. K., & Panzeri, S. (2013) · Nature Reviews Neuroscience · doi:10.1038/nrn3599 · Cited by 857
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Connecting cortex to machines: recent advances in brain interfaces
Donoghue, J. P. (2002) · Nature Neuroscience · doi:10.1038/nn947 · Cited by 721
Metadata
- Authors
- Normann, R. A., Maynard, E. M., Rousche, P. J., & Warren, D. J.
- Venue
- Vision Research
- Publisher
- Elsevier BV
- Published
- 1999-07
- Volume
- 39
- Issue
- 15
- Pages
- 2577-2587
- ISSN
- 0042-6989 (ISSN-L)
- OpenAlex
- W2011029963
- Cited by
- 409
- References
- 29
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- bronze
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/open-access/userlicense/1.0/ (vor, 5131 d)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.