High-performance neuroprosthetic control by an individual with tetraplegia
Open accessAbstract
Background Paralysis or amputation of an arm results in the loss of the ability to orient the hand and grasp, manipulate, and carry objects, functions that are essential for activities of daily living. Brain-machine interfaces could provide a solution to restoring many of these lost functions. We therefore tested whether an individual with tetraplegia could rapidly achieve neurological control of a high-performance prosthetic limb using this type of an interface.Methods We implanted two 96-channel intracortical microelectrodes in the motor cortex of a 52-year-old individual with tetraplegia. Brain-machine-interface training was done for 13 weeks with the goal of controlling an anthropomorphic prosthetic limb with seven degrees of freedom (three-dimensional translation, three-dimensional orientation, one-dimensional grasping). The participant's ability to control the prosthetic limb was assessed with clinical measures of upper limb function. This study is registered with ClinicalTrials.gov, NCT01364480.Findings The participant was able to move the prosthetic limb freely in the three-dimensional workspace on the second day of training. After 13 weeks, robust seven-dimensional movements were performed routinely. Mean success rate on target-based reaching tasks was 91·6% (SD 4·4) versus median chance level 6·2% (95% CI 2·0-15·3). Improvements were seen in completion time (decreased from a mean of 148 s [SD 60] to 112 s [6]) and path efficiency (increased from 0·30 [0·04] to 0·38 [0·02]). The participant was also able to use the prosthetic limb to do skilful and coordinated reach and grasp movements that resulted in clinically significant gains in tests of upper limb function. No adverse events were reported.Interpretation With continued development of neuroprosthetic limbs, individuals with long-term paralysis could recover the natural and intuitive command signals for hand placement, orientation, and reaching, allowing them to perform activities of daily living.Funding Defense Advanced Research Projects Agency, National Institutes of Health, Department of Veterans Affairs, and UPMC Rehabilitation Institute.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“First, using the same fundamental neural decoding and control methods, two participants have achieved similar scores on functional tasks with vision alone (5, 6, 28).”
From A brain-computer interface that evokes tactile sensations improves robotic arm control (2021) · cites this paper as [6]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The flexibility of ConvNets might also be a limitation in some brain‐signal decoding scenarios. For example if the user of a brain–computer interface should learn to adapt her or his brain signals to the decoding model, a simpler feature‐based model might yield better results.”
From Deep learning with convolutional neural networks for EEG decoding and visualization (2017) · cites this paper as Collinger et al., 2013
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“ICMS can also be employed to deliver localized tactile percepts with natural features as well as in human-brain-computer interface applications for better control using area S1 (Collinger et al., 2013; Wodlinger et al., 2015; Downey et al., 2016).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Collinger et al., 2013
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“For depth electrodes, there is also the potential to implant multiple locations, widening coverage [21].”
From Ethical considerations for the use of brain–computer interfaces for cognitive enhancement (2024) · cites this paper as [21]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Prior BCI studies have shown that the motor intention for gross motor skills, such as reaching, grasping or moving a computer cursor, remains neurally encoded in motor cortex after paralysis1–7.”
From High-performance brain-to-text communication via handwriting (2021) · cites this paper as [2]
The cited source says what the claim attributes to it.
In the citing paper
“and has enabled the highest BCI performance to date compared to other recording technologies (EEG, ECoG) for restoring communication7, arm control2,5, and general-purpose computer use39.”
From High-performance brain-to-text communication via handwriting (2021) · cites this paper as [2]
The cited source says what the claim attributes to it.
In the citing paper
“By combining these innovations, it is now possible for a human patient to perform tasks with a bionic arm by thoughts alone (Collinger et al., 2013; Wodlinger et al., 2015).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Collinger et al., 2013
In the citing paper
“Currently, all reported BMI experiments with human patients [26, 35, 57, 58, 150] require the subjects tethered percutaneously to a bench-top computer for neural signal acquisition and decoding.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [26]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal Population Coding of Movement Direction
Georgopoulos, A. P., Schwartz, A. B., & Kettner, R. E. (1986) · Science · doi:10.1126/science.3749885 · Cited by 3,219
Self-citationReach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Generalized Inverses, Ridge Regression, Biased Linear Estimation, and Nonlinear Estimation
Marquardt, D. W. (1970) · Technometrics · doi:10.2307/1267205 · Cited by 2,284
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Self-citationDirect Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,542
Self-citationLyle, R. C. (1981) · International Journal of Rehabilitation Research · doi:10.1097/00004356-198112000-00001 · Cited by 1,335
Postural Hand Synergies for Tool Use
Santello, M., Flanders, M., & Soechting, J. F. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-23-10105.1998 · Cited by 1,215
(1950) · Archives of Pediatrics and Adolescent Medicine · doi:10.1001/archpedi.1950.04040020187020 · Cited by 1,108
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Motor Cortical Representation of Speed and Direction During Reaching
Moran, D. W., & Schwartz, A. B. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.82.5.2676 · Cited by 809
Self-citation
Cited by
Sorted by citations
Items 501–600 of 1,004
An Implantable Neural Sensing Microsystem with Fiber-Optic Data Transmission and Power Delivery
Park, S., Borton, D. A., Kang, M., Nurmikko, A. V., & Song, Y. (2013) · Sensors · doi:10.3390/s130506014 · Cited by 34
Marathe, A. R., & Taylor, D. M. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036015 · Cited by 34
Law, A. J. J., Rivlis, G., & Schieber, M. H. (2014) · Journal of Neurophysiology · doi:10.1152/jn.00373.2013 · Cited by 36
Mrachacz-Kersting, N., Voigt, M., Stevenson, A. J. T., Aliakbaryhosseinabadi, S., Jiang, N., Dremstrup, K., & Farina, D. (2017) · Brain Research · doi:10.1016/j.brainres.2017.08.025 · Cited by 35
Augmenting intracortical brain-machine interface with neurally driven error detectors
Even-Chen, N., Stavisky, S. D., Kao, J. C., Ryu, S. I., & Shenoy, K. V. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8dc1 · Cited by 35
Demonstration of a portable intracortical brain-computer interface
Weiss, J. M., Gaunt, R. A., Franklin, R. K., Boninger, M. L., & Collinger, J. L. (2019) · Brain-Computer Interfaces · doi:10.1080/2326263x.2019.1709260 · Cited by 37
Self-citationReal-time prediction learning for the simultaneous actuation of multiple prosthetic joints
Pilarski, P. M., Dick, T., & Sutton, R. S. (2013) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2013.6650435 · Cited by 34
Harnessing Prefrontal Cognitive Signals for Brain–Machine Interfaces
Min, B., Chavarriaga, R., & Millán, J. D. R. (2017) · Trends in biotechnology · doi:10.1016/j.tibtech.2017.03.008 · Cited by 35
Lee, M.-C., Karimi-Bidhendi, A., Malekzadeh-Arasteh, O., Wang, P. T., Do, A. H., Nenadić, Z., & Heydari, P. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2899521 · Cited by 34
Flexible Micropillar Electrode Arrays for In Vivo Neural Activity Recordings
Du, M., Guan, S., Gao, L., Lv, S., Yang, S., Shi, J., Wang, J., Li, H., & Fang, Y. Z. (2019) · Small · doi:10.1002/smll.201900582 · Cited by 34
Pels, E. G. M., Aarnoutse, E. J., Ramsey, N. F., & Vansteensel, M. J. (2017) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968317714577 · Cited by 33
Farisco, M., Pennartz, C. M. A., Annen, J., Cecconi, B., & Evers, K. (2022) · BMC Medical Ethics · doi:10.1186/s12910-022-00770-3 · Cited by 32
3D-printed flexible neural probes for recordings at single-neuron level
Momin, M., Feng, L., Ahmed, S., Ren, J., Hossain, A., Zhang, S., & Zhou, T. (2024) · Device · doi:10.1016/j.device.2024.100519 · Cited by 33
Restoring Speech Using Brain–Computer Interfaces
Stavisky, S. D. (2025) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110122-012818 · Cited by 42
Hettick, M., Ho, E., Poole, A. J., Monge, M., Papageorgiou, D., Takahashi, K., LaMarca, M., Trietsch, D., Reed, K., Murphy, M. E., et al. (2025) · Nature Biomedical Engineering · doi:10.1038/s41551-025-01501-w · Cited by 43
Sensitivity to microstimulation of somatosensory cortex distributed over multiple electrodes
Kim, S., Callier, T., Tabot, G. A., Tenore, F. V., & Bensmaı̈a, S. J. (2015) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2015.00047 · Cited by 33
Recent advances in bioelectric prostheses
Pasquina, P. F., Perry, B. N., Miller, M. E., Ling, G. S. F., & Tsao, J. W. (2015) · Neurology Clinical Practice · doi:10.1212/cpj.0000000000000132 · Cited by 33
Key considerations in designing a somatosensory neuroprosthesis
Delhaye, B. P., Saal, H. P., & Bensmaı̈a, S. J. (2016) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2016.11.001 · Cited by 35
An, H., Nason, S. R., Lim, J., Kwon, K., Willsey, M. S., Patil, P. G., Kim, H.-S., Sylvester, D., Chestek, C. A., & Blaauw, D. T. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3175926 · Cited by 33
Sensory control of normal movement and of movement aided by neural prostheses
Procházka, A. (2015) · Journal of Anatomy · doi:10.1111/joa.12311 · Cited by 37
Give Me a Sign: Decoding Complex Coordinated Hand Movements Using High-Field fMRI
Bleichner, M. G., Jansma, J. M., Sellmeijer, J., Raemaekers, M. A. H., & Ramsey, N. F. (2013) · Brain Topography · doi:10.1007/s10548-013-0322-x · Cited by 33
Bonding Brains to Machines: Ethical Implications of Electroceuticals for the Human Brain
Clausen, J. (2013) · Neuroethics · doi:10.1007/s12152-013-9186-8 · Cited by 34
Vadera, S., Marathe, A. R., Gonzalez-Martinez, J. A., & Taylor, D. M. (2013) · Neurosurgical FOCUS · doi:10.3171/2013.3.focus1373 · Cited by 33
Lampe, T., Fiederer, L. D. J., Voelker, M., Knorr, A. G., Riedmiller, M., & Ball, T. (2014) · ACM International Conference on Intelligent User Interfaces (IUI) · doi:10.1145/2557500.2557533 · Cited by 34
Yang, Y., Wang, J., Bailer, C., Cherkassky, V. L., & Just, M. A. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.10.029 · Cited by 34
Dai, J., Zhang, P., Sun, H., Qiao, X., Zhao, Y., Ma, J., Li, S., Zhou, J., & Wang, C. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab0bfb · Cited by 33
Shaikh, S., So, R. Q., Sibindi, T. M., Libedinsky, C., & Basu, A. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2944486 · Cited by 33
BRAND: a platform for closed-loop experiments with deep network models
Ali, Y. H., Bodkin, K., Rigotti-Thompson, M., Patel, K., Card, N. S., Bhaduri, B., Nason-Tomaszewski, S. R., Mifsud, D. M., Hou, X., Nicolas, C., et al. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad3b3a · Cited by 32
Transfer of information by BMI
Tehovnik, E. J., Woods, L., & Slocum, W. M. (2013) · Neuroscience · doi:10.1016/j.neuroscience.2013.10.003 · Cited by 32
Lobel, D. A., & Lee, K. H. (2014) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2014.02.003 · Cited by 32
Long-term decoding of movement force and direction with a wireless myoelectric implant
Morel, P., Ferrea, E., Taghizadeh, B., Audí, J. M. C., Ruff, R., Hoffmann, K., Lewis, S., Russold, M., Dietl, H., Saleh, L. A., et al. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/1/016002 · Cited by 32
Rose, N. (2016) · Body & Society · doi:10.1177/1357034x15623363 · Cited by 39
Perruchoud, D., Pisotta, I., Carda, S., Murray, M. M., & Ionta, S. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/041001 · Cited by 32
Decoding Information for Grasping from the Macaque Dorsomedial Visual Stream
Filippini, M., Breveglieri, R., Akhras, M. A., Bosco, A., Chinellato, E., & Fattori, P. (2017) · Journal of Neuroscience · doi:10.1523/jneurosci.3077-16.2017 · Cited by 33
Functional remodeling of subtype-specific markers surrounding implanted neuroprostheses
Salatino, J. W., Winter, B. M., Drazin, M. H., & Purcell, E. K. (2017) · Journal of Neurophysiology · doi:10.1152/jn.00162.2017 · Cited by 32
Zhang, M., Schwemmer, M. A., Ting, J. E., Majstorovic, C., Friedenberg, D. A., Bockbrader, M. A., Mysiw, W. J., Rezai, A. R., Annetta, N. V., Bouton, C. E., et al. (2018) · Bioelectronic Medicine · doi:10.1186/s42234-018-0011-x · Cited by 33
The role of inflammation on the functionality of intracortical microelectrodes
Gaire, J., Lee, H. C., Hilborn, N., Ward, R., Regan, M., & Otto, K. J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae4b6 · Cited by 35
Bypassing stroke-damaged neural pathways via a neural interface induces targeted cortical adaptation
Kato, K., Sawada, M., & Nishimura, Y. (2019) · Nature Communications · doi:10.1038/s41467-019-12647-y · Cited by 33
Carìa, A., da Rocha, J. L. D., Gallitto, G., Birbaumer, N., Sitaram, R., & Ramos‐Murguialday, A. (2019) · Neurotherapeutics · doi:10.1007/s13311-019-00816-2 · Cited by 32
The sensory representation of causally controlled objects
Clancy, K. B., & Mrsic‐Flogel, T. D. (2020) · Neuron · doi:10.1016/j.neuron.2020.12.001 · Cited by 32
A modular strategy for next-generation upper-limb sensory-motor neuroprostheses
Shokur, S., Mazzoni, A., Schiavone, G., Weber, D. J., & Micera, S. (2021) · Med · doi:10.1016/j.medj.2021.05.002 · Cited by 35
Self-citationIntracortical Microelectrode Array Unit Yield under Chronic Conditions: A Comparative Evaluation
Usoro, J. O., Sturgill, B. S., Musselman, K. C., Capadona, J. R., & Pancrazio, J. J. (2021) · Micromachines · doi:10.3390/mi12080972 · Cited by 34
Deep brain–machine interfaces: sensing and modulating the human deep brain
Sui, Y., Yu, H., Zhang, C., Chen, Y., Jiang, C., & Li, L. (2022) · National Science Review · doi:10.1093/nsr/nwac212 · Cited by 33
Closed-Loop Control of a Neuroprosthetic Hand by Magnetoencephalographic Signals
Fukuma, R., Yanagisawa, T., Yorifuji, S., Kato, R., Yokoi, H., Hirata, M., Saitoh, Y., Kishima, H., Kamitani, Y., & Yoshimine, T. (2015) · PLoS ONE · doi:10.1371/journal.pone.0131547 · Cited by 32
Chen, C., Shin, D., Watanabe, H., Nakanishi, Y., Kambara, H., Yoshimura, N., Nambu, A., Isa, T., Nishimura, Y., & Koike, Y. (2014) · Neuroscience Research · doi:10.1016/j.neures.2014.03.010 · Cited by 33
Lahr, J., Schwartz, C., Heimbach, B., Aertsen, A., Rickert, J., & Tonio Ball, A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/4/043001 · Cited by 32
Qualitative assessment of Tongue Drive System by people with high-level spinal cord injury
Kim, J., Park, H., Bruce, J. A., MSPT, Rowles, D. M., Holbrook, J. S., Nardone, B., West, D. P., Laumann, A. E., UK, et al. (2014) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2013.08.0178 · Cited by 32
The future of upper extremity rehabilitation robotics: research and practice
Vu, P. P., Chestek, C. A., Nason, S. R., Kung, T. A., Kemp, S. W. P., & Cederna, P. S. (2020) · Muscle & Nerve · doi:10.1002/mus.26860 · Cited by 33
The Layer 7 Cortical Interface: A Scalable and Minimally Invasive Brain–Computer Interface Platform
Hettick, M., Ho, E., Poole, A. J., Monge, M., Papageorgiou, D., Takahashi, K., LaMarca, M., Trietsch, D., Reed, K., Murphy, M., et al. (2022) · doi:10.1101/2022.01.02.474656 · Cited by 31
An Ultraflexible Electrode Array for Large‐Scale Chronic Recording in the Nonhuman Primate Brain
Tian, Y., Yin, J., Wang, C., He, Z., Xie, J., Feng, X., Zhou, Y., Ma, T., Xie, Y., Li, X., et al. (2023) · Advanced Science · doi:10.1002/advs.202302333 · Cited by 32
Defining Ecological Strategies in Neuroprosthetics
Courtine, G., & Bloch, J. (2015) · Neuron · doi:10.1016/j.neuron.2015.02.039 · Cited by 31
Mahajan, R., & Bansal, D. (2017) · Procedia Computer Science · doi:10.1016/j.procs.2017.09.158 · Cited by 32
Neurorestorative interventions involving bioelectronic implants after spinal cord injury
Cho, N., Squair, J. W., Bloch, J., & Courtine, G. (2019) · Bioelectronic Medicine · doi:10.1186/s42234-019-0027-x · Cited by 32
A 25 Mbps, 12.4 pJ/b DQPSK Backscatter Data Uplink for the NeuroDisc Brain–Computer Interface
Rosenthal, J., Sharma, A., Kampianakis, E., & Reynolds, M. S. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2938511 · Cited by 31
Kumaravelu, K., Tomlinson, T., Callier, T., Sombeck, J. T., Bensmaı̈a, S. J., Miller, L. E., & Grill, W. M. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abacd8 · Cited by 32
The Hybridization of the Human with Brain Implants: The Neuralink Project
Fourneret, É. (2020) · Cambridge Quarterly of Healthcare Ethics · doi:10.1017/s0963180120000419 · Cited by 31
Generalizable cursor click decoding using grasp-related neural transients
Dekleva, B. M., Weiss, J. M., Boninger, M. L., & Collinger, J. L. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac16b2 · Cited by 33
Self-citationImplicit mechanisms of intention
Aflalo, T., Zhang, C. Y., Revechkis, B., Rosario, E. R., Pouratian, N., & Andersen, R. A. (2022) · Current Biology · doi:10.1016/j.cub.2022.03.047 · Cited by 33
Designing Dynamical Properties of Brain–Machine Interfaces to Optimize Task-Specific Performance
Gowda, S., Orsborn, A. L., Overduin, S. A., Moorman, H. G., & Carmena, J. M. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2309673 · Cited by 33
Multisession, noninvasive closed-loop neuroprosthetic control of grasping by upper limb amputees
Agashe, H. A., Paek, A. Y., & Contreras-Vidal, J. L. (2016) · Progress in brain research · doi:10.1016/bs.pbr.2016.04.016 · Cited by 32
Endovascular Brain-Computer Interfaces in Poststroke Paralysis
Brannigan, J., Fry, A., Opie, N. L., Campbell, B. C. V., Mitchell, P. J., & Oxley, T. J. (2023) · Stroke · doi:10.1161/strokeaha.123.037719 · Cited by 32
What is the optimal task difficulty for reinforcement learning of brain self-regulation?
Bauer, R. H., Vukelić, M., & Gharabaghi, A. (2016) · Clinical Neurophysiology · doi:10.1016/j.clinph.2016.06.016 · Cited by 30
A neural network for online spike classification that improves decoding accuracy
Issar, D., Williamson, R. C., Khanna, S. B., & Smith, M. A. (2020) · Journal of Neurophysiology · doi:10.1152/jn.00641.2019 · Cited by 30
Cortical Control of Virtual Self-Motion Using Task-Specific Subspaces
Schroeder, K. E., Perkins, S. M., Wang, Q., & Churchland, M. M. (2021) · Journal of Neuroscience · doi:10.1523/jneurosci.2687-20.2021 · Cited by 31
Nicolelis, M. A. L., Alho, E. J. L., Donati, A. R. C., Yamauti, S. Y., Aratanha, M. A., Bao, G., Campos, D. S. F., Almeida, S. B., Fischer, D., & Shokur, S. (2022) · Scientific Reports · doi:10.1038/s41598-022-24864-5 · Cited by 31
Toward Building Hybrid Biological/in silico Neural Networks for Motor Neuroprosthetic Control
Kocatürk, M., Gülçür, H. Ö., & Canbeyli, R. S. (2015) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2015.00008 · Cited by 30
Degraded EEG decoding of wrist movements in absence of kinaesthetic feedback
Galán, F., Baker, M. R., Alter, K., & Baker, S. N. (2014) · Human Brain Mapping · doi:10.1002/hbm.22653 · Cited by 30
A survey of brain computer interfaces and their applications
Major, T. C., & Conrad, J. M. (2014) · IEEE SoutheastCon · doi:10.1109/secon.2014.6950751 · Cited by 30
Huggins, J. E., Guger, C., Ziat, M., Zander, T. O., Taylor, D., Tangermann, M., Soria‐Frisch, A., Simeral, J. D., Scherer, R., Rupp, R., et al. (2017) · Brain-Computer Interfaces · doi:10.1080/2326263x.2016.1275488 · Cited by 32
Self-citationNeuroplasticity subserving the operation of brain–machine interfaces
Oweiss, K. G., & Badreldin, I. S. (2015) · Neurobiology of Disease · doi:10.1016/j.nbd.2015.05.001 · Cited by 33
In-home and remote use of robotic body surrogates by people with profound motor deficits
Grice, P. M., & Kemp, C. C. (2019) · PLoS ONE · doi:10.1371/journal.pone.0212904 · Cited by 33
Endovascular neuromodulation: safety profile and future directions
Raza, S. A., Opie, N. L., Morokoff, A., Sharma, R. P., Mitchell, P. J., & Oxley, T. J. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.00351 · Cited by 29
Closed-Loop Stimulation in Emotional Circuits for Neuro-Psychiatric Disorders
Widge, A. S., & Moritz, C. T. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-802452-2.00017-2 · Cited by 29
Mang, J., Xu, Z., Qi, Y., & Zhang, T. (2023) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2023.1271967 · Cited by 29
Reward signals in the motor cortex: from biology to neurotechnology
Derosière, G., Shokur, S., & Vassiliadis, P. (2025) · Nature Communications · doi:10.1038/s41467-024-55016-0 · Cited by 30
In vivo microelectrode arrays for neuroscience
Williams, N. P., Vöröslakos, M., Shi, D., Pwint, M. Y., Lanzio, V., Mao, H., Zolotavin, P., Yoon, E., Stieglitz, T., Xie, C., et al. (2025) · Nature Reviews Methods Primers · doi:10.1038/s43586-025-00399-7 · Cited by 30
Self-citationNew Perspectives on Neuroengineering and Neurotechnologies: NSF-DFG Workshop Report
Moritz, C. T., Ruther, P., Goering, S., Stett, A., Ball, T., Burgard, W., Chudler, E. H., & Rao, R. P. N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2543662 · Cited by 30
Sensorimotor experience and verb-category mapping in human sensory, motor and parietal neurons
Yang, Y., Dickey, M. W., Fiez, J. A., Murphy, B., Mitchell, T. M., Collinger, J. L., Tyler‐Kabara, E. C., Boninger, M. L., & Wang, W. (2017) · Cortex · doi:10.1016/j.cortex.2017.04.021 · Cited by 30
Self-citationEven-Chen, N., Stavisky, S. D., Pandarinath, C., Nuyujukian, P., Blabe, C. H., Hochberg, L. R., Henderson, J. M., & Shenoy, K. V. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2776204 · Cited by 31
Clinical neuroprosthetics: Today and tomorrow
Lee, M. B., Kramer, D. R., Peng, T. D., Barbaro, M. F., Liu, C. Y., Kellis, S., & Lee, B. (2019) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2019.07.056 · Cited by 29
Dunlap, C. F., Colachis, S. C., Meyers, E., Bockbrader, M. A., & Friedenberg, D. A. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.558987 · Cited by 30
Adaptive latent state modeling of brain network dynamics with real-time learning rate optimization
Yang, Y., Ahmadipour, P., & Shanechi, M. M. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abcefd · Cited by 31
Davis, K., Meschede-Krasa, B., Cajigas, I., Prins, N. W., Alver, C. G., Gallo, S., Bhatia, S., Abel, J. H., Naeem, J., Fisher, L., et al. (2022) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-022-01026-2 · Cited by 31
Xia, M., Agca, B. N., Yoshida, T., Choi, J., Amjad, U., Bose, K., Keren, N., Zukerman, S., Cima, M. J., Graybiel, A. M., et al. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115625 · Cited by 29
Colamarino, E., Lorusso, M., Pichiorri, F., Toppi, J., Tamburella, F., Serratore, G., Riccio, A., Tomaiuolo, F., Bigioni, A., Giove, F., et al. (2023) · BMC Neurology · doi:10.1186/s12883-023-03442-w · Cited by 29
Coarse Electrocorticographic Decoding of Ipsilateral Reach in Patients with Brain Lesions
Hotson, G., Fifer, M. S., Acharya, S., Benz, H. L., Anderson, W. S., Thakor, N. V., & Crone, N. E. (2014) · PLoS ONE · doi:10.1371/journal.pone.0115236 · Cited by 30
Prediction of muscle activity during loaded movements of the upper limb
Tibold, R., & Fuglevand, A. J. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-6 · Cited by 29
Optoelectronic system for brain neuronal network stimulation
Mishchenko, M. A., Gerasimova, S. A., Lebedeva, A., Lepekhina, L. S., Pisarchik, A. N., & Kazantsev, V. (2018) · PLoS ONE · doi:10.1371/journal.pone.0198396 · Cited by 29
A Survey of EEG and Machine Learning-Based Methods for Neural Rehabilitation
Singh, J., Ali, F., Gill, R., Shah, B., & Kwak, D. (2023) · IEEE Access · doi:10.1109/access.2023.3321067 · Cited by 28
Wang, X., Wu, S. P., Yang, H., Bao, Y., Li, Z., Gan, C., Deng, Y., Cao, J., Li, X., Wang, Y., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-53720-5 · Cited by 29
Brain–computer interface control with artificial intelligence copilots
Lee, J. Y., Lee, S., Mishra, A., Xu, Y., McMahan, B., Gaisford, B., Kobashigawa, C., Qu, M., Xie, C., & Kao, J. C. (2025) · Nature Machine Intelligence · doi:10.1038/s42256-025-01090-y · Cited by 40
Emerging Neural Stimulation Technologies for Bladder Dysfunctions
Lee, J. W., Kim, D., Yoo, S., Lee, H., Lee, G.-H., & Nam, Y. (2015) · International Neurourology Journal · doi:10.5213/inj.2015.19.1.3 · Cited by 28
Brain–computer interfaces for patients with disorders of consciousness
Gibson, R. M., Owen, A. M., & Cruse, D. (2016) · Progress in brain research · doi:10.1016/bs.pbr.2016.04.003 · Cited by 29
Huang, H., Sharma, H. S., Chen, L., Otom, A. H., Zoubi, Z. M. A., Saberi, H., Muresanu, D. F., & He, X. (2018) · Journal of Neurorestoratology · doi:10.26599/jnr.2018.9040013 · Cited by 28
Kalaska, J. F. (2019) · F1000Research · doi:10.12688/f1000research.17161.1 · Cited by 28
Transcending the brain: is there a cost to hacking the nervous system?
Khan, S., & Aziz, T. Z. (2019) · Brain Communications · doi:10.1093/braincomms/fcz015 · Cited by 28
Akan, O. B., Ramezani, H., Civas, M., Cetinkaya, O., Bilgin, B. A., & Abbasi, N. A. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3056455 · Cited by 28
Zaer, H., Deshmukh, A., Orłowski, D., Fan, W., Prouvot, P.-H., Glud, A. N., Jensen, M. B., Worm, E. S., Lukacova, S., Mikkelsen, T. W., et al. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2021.618626 · Cited by 30
Cross-Platform Implementation of an SSVEP-Based BCI for the Control of a 6-DOF Robotic Arm
Quiles, E., Dadone, J., Chio, N., & García, E. (2022) · Sensors · doi:10.3390/s22135000 · Cited by 28
Song, S., Regan, B., Ereifej, E. S., Chan, E. R., & Capadona, J. R. (2022) · Cells · doi:10.3390/cells11152348 · Cited by 28
Metadata
- Authors
- Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B.
- Affiliations
- University of Pittsburgh (US)
- Corresponding author
- Schwartz, Andrew B
- ORCID
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2013-02
- Volume
- 381
- Issue
- 9866
- Pages
- 557-564
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- PMC
- PMC3641862
- OpenAlex
- W2144910141
- Cited by
- 1,848
- References
- 31
- Citations by year
- 2026: 87 · 2025: 120 · 2024: 120 · 2023: 140 · 2022: 123 · 2021: 143 · 2020: 157 · 2019: 143 · 2018: 147 · 2017: 129 · 2016: 145 · 2015: 144 · 2014: 158 · 2013: 90
- FWCI
- 64.30
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- U.S. Department of Defense
- University of Pittsburgh
- National Institutes of Health (UL1TR000005, 5r01ns050256-05, KL2TR000146)
- Defense Advanced Research Projects Agency
- National Institute of Neurological Disorders and Stroke (RC1NS070311, R01-NS050256)
- National Center for Advancing Translational Sciences
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- brain-computer interface, tetraplegia, intracortical microelectrodes, motor cortex, upper limb function, reach-to-grasp, upper limb paralysis, activities of daily living, prosthetic control
- MeSH terms
- Arm, Artificial Limbs, Female, Humans, Microelectrodes, Middle Aged, Psychomotor Performance, Quadriplegia, Hand Strength, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review