The DOI matches its Crossref record; 30 of the 31 references it cites were found in a registry or an index.
High-performance neuroprosthetic control by an individual with tetraplegia
Open accessAbstract
Background Paralysis or amputation of an arm results in the loss of the ability to orient the hand and grasp, manipulate, and carry objects, functions that are essential for activities of daily living. Brain-machine interfaces could provide a solution to restoring many of these lost functions. We therefore tested whether an individual with tetraplegia could rapidly achieve neurological control of a high-performance prosthetic limb using this type of an interface.Methods We implanted two 96-channel intracortical microelectrodes in the motor cortex of a 52-year-old individual with tetraplegia. Brain-machine-interface training was done for 13 weeks with the goal of controlling an anthropomorphic prosthetic limb with seven degrees of freedom (three-dimensional translation, three-dimensional orientation, one-dimensional grasping). The participant's ability to control the prosthetic limb was assessed with clinical measures of upper limb function. This study is registered with ClinicalTrials.gov, NCT01364480.Findings The participant was able to move the prosthetic limb freely in the three-dimensional workspace on the second day of training. After 13 weeks, robust seven-dimensional movements were performed routinely. Mean success rate on target-based reaching tasks was 91·6% (SD 4·4) versus median chance level 6·2% (95% CI 2·0-15·3). Improvements were seen in completion time (decreased from a mean of 148 s [SD 60] to 112 s [6]) and path efficiency (increased from 0·30 [0·04] to 0·38 [0·02]). The participant was also able to use the prosthetic limb to do skilful and coordinated reach and grasp movements that resulted in clinically significant gains in tests of upper limb function. No adverse events were reported.Interpretation With continued development of neuroprosthetic limbs, individuals with long-term paralysis could recover the natural and intuitive command signals for hand placement, orientation, and reaching, allowing them to perform activities of daily living.Funding Defense Advanced Research Projects Agency, National Institutes of Health, Department of Veterans Affairs, and UPMC Rehabilitation Institute.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“First, using the same fundamental neural decoding and control methods, two participants have achieved similar scores on functional tasks with vision alone (5, 6, 28).”
From A brain-computer interface that evokes tactile sensations improves robotic arm control (2021) · cites this paper as [6]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The flexibility of ConvNets might also be a limitation in some brain‐signal decoding scenarios. For example if the user of a brain–computer interface should learn to adapt her or his brain signals to the decoding model, a simpler feature‐based model might yield better results.”
From Deep learning with convolutional neural networks for EEG decoding and visualization (2017) · cites this paper as Collinger et al., 2013
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“ICMS can also be employed to deliver localized tactile percepts with natural features as well as in human-brain-computer interface applications for better control using area S1 (Collinger et al., 2013; Wodlinger et al., 2015; Downey et al., 2016).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Collinger et al., 2013
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“For depth electrodes, there is also the potential to implant multiple locations, widening coverage [21].”
From Ethical considerations for the use of brain–computer interfaces for cognitive enhancement (2024) · cites this paper as [21]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Prior BCI studies have shown that the motor intention for gross motor skills, such as reaching, grasping or moving a computer cursor, remains neurally encoded in motor cortex after paralysis1–7.”
From High-performance brain-to-text communication via handwriting (2021) · cites this paper as [2]
The cited source says what the claim attributes to it.
In the citing paper
“and has enabled the highest BCI performance to date compared to other recording technologies (EEG, ECoG) for restoring communication7, arm control2,5, and general-purpose computer use39.”
From High-performance brain-to-text communication via handwriting (2021) · cites this paper as [2]
The cited source says what the claim attributes to it.
In the citing paper
“By combining these innovations, it is now possible for a human patient to perform tasks with a bionic arm by thoughts alone (Collinger et al., 2013; Wodlinger et al., 2015).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Collinger et al., 2013
In the citing paper
“Currently, all reported BMI experiments with human patients [26, 35, 57, 58, 150] require the subjects tethered percutaneously to a bench-top computer for neural signal acquisition and decoding.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [26]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal Population Coding of Movement Direction
Georgopoulos, A. P., Schwartz, A. B., & Kettner, R. E. (1986) · Science · doi:10.1126/science.3749885 · Cited by 3,219
Self-citationReach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Generalized Inverses, Ridge Regression, Biased Linear Estimation, and Nonlinear Estimation
Marquardt, D. W. (1970) · Technometrics · doi:10.2307/1267205 · Cited by 2,284
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Self-citationDirect Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,542
Self-citationLyle, R. C. (1981) · International Journal of Rehabilitation Research · doi:10.1097/00004356-198112000-00001 · Cited by 1,335
Postural Hand Synergies for Tool Use
Santello, M., Flanders, M., & Soechting, J. F. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-23-10105.1998 · Cited by 1,215
(1950) · Archives of Pediatrics and Adolescent Medicine · doi:10.1001/archpedi.1950.04040020187020 · Cited by 1,108
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Motor Cortical Representation of Speed and Direction During Reaching
Moran, D. W., & Schwartz, A. B. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.82.5.2676 · Cited by 809
Self-citation
Cited by
Sorted by citations
Items 701–800 of 1,004
Commonly Overlooked Factors in Biocompatibility Studies of Neural Implants
Kumosa, L. S. (2023) · Advanced Science · doi:10.1002/advs.202205095 · Cited by 21
Challenges of neural interfaces for stroke motor rehabilitation
Vidaurre, C., Irastorza-Landa, N., Sarasola-Sanz, A., Insausti-Delgado, A., Ray, A. M., Bibián, C., Helmhold, F., Mahmoud, W. J., Ortego-Isasa, I., López‐Larraz, E., et al. (2023) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2023.1070404 · Cited by 23
Zschorlich, V. R., & Köhling, R. (2013) · PLoS ONE · doi:10.1371/journal.pone.0083845 · Cited by 21
Zhao, Y., Tang, L. J., Rennaker, R. L., Hutchens, C., & Ibrahim, T. S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0077759 · Cited by 21
Severely affected ALS patients have broad and high expectations for brain-machine interfaces
Kageyama, Y., Hirata, M., Yanagisawa, T., Shimokawa, T., Sawada, J., Morris, S., 水島, 希., Kishima, H., Sakura, O., & Yoshimine, T. (2014) · Amyotrophic Lateral Sclerosis and Frontotemporal Degeneration · doi:10.3109/21678421.2014.951943 · Cited by 21
Young, D. R., Willett, F. R., Memberg, W. D., Murphy, B., Rezaii, P. G., Walter, B. L., Sweet, J., Miller, J. P., Shenoy, K. V., Hochberg, L. R., et al. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf606 · Cited by 22
Design and testing of a 96-channel neural interface module for the Networked Neuroprosthesis system
Bullard, A. J., Nason, S. R., Irwin, Z. T., Nu, C. S., Smith, B., Campean, A., Peckham, P. H., Kilgore, K. L., Willsey, M. S., Patil, P. G., et al. (2019) · Bioelectronic Medicine · doi:10.1186/s42234-019-0019-x · Cited by 21
Decoding neural activity to predict rat locomotion using intracortical and epidural arrays
Barroso, F. O., Yoder, B., Tentler, D. P., Wallner, J. J., Kinkhabwala, A. A., Jantz, M., Flint, R. D., Tostado-Marcos, P., Pei, E., Satish, A. D. R., et al. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab0698 · Cited by 21
Decoding visual information from high-density diffuse optical tomography neuroimaging data
Tripathy, K., Markow, Z. E., Fishell, A. K., Sherafati, A., Burns‐Yocum, T. M., Schroeder, M. L., Svoboda, A. M., Eggebrecht, A. T., Anastasio, M. A., Schlaggar, B. L., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117516 · Cited by 21
SSVEP-assisted RSVP brain–computer interface paradigm for multi-target classification
Ko, L., Sankar, D. S. V., Huang, Y., Lu, Y.-C., Shaw, S., & Jung, T. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abd1c0 · Cited by 21
Microelectrode Array Recordings from the Ventral Roots in Chronically Implanted Cats
Debnath, S., Bauman, M. J., Fisher, L. E., Weber, D. J., & Gaunt, R. A. (2014) · Frontiers in Neurology · doi:10.3389/fneur.2014.00104 · Cited by 21
Self-citationArduin, P.-J., Frégnac, Y., Shulz, D. E., & Ego‐Stengel, V. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00206 · Cited by 22
Scientific profile of brain–computer interfaces: Bibliometric analysis in a 10-year period
Hu, K., Chen, C., Meng, Q., Williams, Z. M., & Xu, W. (2016) · Neuroscience Letters · doi:10.1016/j.neulet.2016.10.022 · Cited by 21
BCI Use and Its Relation to Adaptation in Cortical Networks
Casimo, K., Weaver, K. E., Wander, J. D., & Ojemann, J. G. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2681963 · Cited by 21
Liu, K., Zhang, H., Hu, M., Li, Z., Xu, K., Chen, D., Cui, W., Lv, C., Ding, R., Geng, X., et al. (2024) · Materials Advances · doi:10.1039/d3ma01105d · Cited by 23
Bonanno, M., Saracino, B., Ciancarelli, I., Panza, G., Manuli, A., Morone, G., & Calabrò, R. S. (2025) · Healthcare · doi:10.3390/healthcare13131580 · Cited by 23
Kumar, N., & Michmizos, K. P. (2022) · Scientific Reports · doi:10.1038/s41598-022-05079-0 · Cited by 21
Vansteensel, M. J., Branco, M. P., Leinders, S., Freudenburg, Z. V., Schippers, A., Geukes, S. H., Gaytant, M. A., Gosselaar, P. H., Aarnoutse, E. J., & Ramsey, N. F. (2022) · Neurorehabilitation and neural repair · doi:10.1177/15459683221125788 · Cited by 21
Martínez, S., Veirano, F., Constandinou, T. G., & Silveira, F. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3228895 · Cited by 20
Calibration-Free and Hardware-Efficient Neural Spike Detection for Brain Machine Interfaces
Zhang, Z., Feng, P., Oprea, A., & Constandinou, T. G. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3278531 · Cited by 20
Tao, G., Yang, S., Xu, J., Wang, L., & Yang, B. (2024) · Frontiers in Neurology · doi:10.3389/fneur.2024.1361235 · Cited by 20
Wu, X., Metcalfe, B., He, S., Tan, H., & Zhang, D. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3421551 · Cited by 24
Bertrand, A., Seo, D., Maksimovic, F., Carmena, J. M., Maharbiz, M. M., Alon, E., & Rabaey, J. M. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944161 · Cited by 21
Sugata, H., Hirata, M., Yanagisawa, T., Matsushita, K., Yorifuji, S., & Yoshimine, T. (2016) · Scientific Reports · doi:10.1038/srep24663 · Cited by 23
Hagengruber, A., & Vogel, J. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512703 · Cited by 20
External Robotic Arm vs. Upper Limb Exoskeleton: What Do Potential Users Need?
Nam, H. S., Seo, H. G., Leigh, J., Kim, Y. J., Kim, S., & Bang, M. S. (2019) · Applied Sciences · doi:10.3390/app9122471 · Cited by 20
Yao, Z., Hessburg, J. P., Kumar, J. N. A., & Francis, J. T. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00579 · Cited by 22
A Robust Encoding Scheme for Delivering Artificial Sensory Information via Direct Brain Stimulation
Bjånes, D. A., & Moritz, C. T. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2936739 · Cited by 20
LSTM Improves Accuracy of Reaching Trajectory Prediction From Magnetoencephalography Signals
Yeom, H. G., Kim, J. S., & Chung, C. K. (2020) · IEEE Access · doi:10.1109/access.2020.2969720 · Cited by 20
Studies to Overcome Brain–Computer Interface Challenges
Choi, W.-S., & Yeom, H. G. (2022) · Applied Sciences · doi:10.3390/app12052598 · Cited by 20
Asynchronous Decoding of Error Potentials during the Monitoring of a Reaching Task
Omedes, J., Iturrate, I., Chavarriaga, R., & Montesano, L. (2015) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2015.541 · Cited by 20
Management of Chronic Spinal Cord Dysfunction
Abrams, G., & Ganguly, K. (2015) · CONTINUUM Lifelong Learning in Neurology · doi:10.1212/01.con.0000461092.86865.a4 · Cited by 20
Prins, N. W., Sanchez, J. C., & Prasad, A. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00111 · Cited by 20
Single-trial decoding of intended eye movement goals from lateral prefrontal cortex neural ensembles
Boulay, C., Pieper, F., Leavitt, M. L., Martínez-Trujillo, J., & Sachs, A. J. (2015) · Journal of Neurophysiology · doi:10.1152/jn.00788.2015 · Cited by 20
Using machine learning to reveal the population vector from EEG signals
Kobler, R. J., Almeida, I. A. T., Sburlea, A. I., & Muller-Putz, G. R. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab7490 · Cited by 20
Thukral, A., Ershad, F., Enan, N., Rao, Z., & Yu, C. (2018) · IEEE Nanotechnology Magazine · doi:10.1109/mnano.2017.2781290 · Cited by 19
Brain-Machine Interfaces: The Perception-Action Closed Loop: A Two-Learner System
Millan, J. D. R. (2015) · IEEE Systems, Man, and Cybernetics Magazine · doi:10.1109/msmc.2014.2386901 · Cited by 19
The Pursuit of Chronically Reliable Neural Interfaces: A Materials Perspective
Guo, L. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00599 · Cited by 19
Artificial Intelligence in Science and Society: The Vision of USERN
Dorigo, T., Brown, G. D., Casonato, C., Cerdà, A., Ciarrochi, J., Lio, M. D., D’Souza, N., Gauger, N. R., Hayes, S. C., Hofmann, S. G., et al. (2025) · IEEE Access · doi:10.1109/access.2025.3529357 · Cited by 21
Park, J. Y., Barrera, N. D., Bai, T., Meng, E. F., Fang, H., & Lee, H. (2025) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110122-121128 · Cited by 19
A mosaic of whole-body representations on the human precentral gyrus
Deo, D. R., Okorokova, E. V., Pritchard, A. L., Hahn, N. V., Card, N. S., Nason, S. R., Jude, J. J., Hosman, T., Choi, E. Y., Qiu, D., et al. (2026) · Nature · doi:10.1038/s41586-026-10653-x · Cited by 21
Self-citationBrain-Computer Interface, Neuromodulation, and Neurorehabilitation Strategies for Spinal Cord Injury
Cajigas, I., & Vedantam, A. (2021) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2021.03.012 · Cited by 23
Bavishi, S., Rosenthal, J., & Bockbrader, M. A. (2018) · Elsevier eBooks · doi:10.1016/b978-0-323-54456-6.00017-7 · Cited by 19
Clinical neuroscience and neurotechnology: An amazing symbiosis
Cometa, A., Falasconi, A., Biasizzo, M., Carpaneto, J., Horn, A., Mazzoni, A., & Micera, S. (2022) · iScience · doi:10.1016/j.isci.2022.105124 · Cited by 21
Thin flexible arrays for long-term multi-electrode recordings in macaque primary visual cortex
Merken, L., Schelles, M., Ceyssens, F., Kraft, M. D., & Janssen, P. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac98e2 · Cited by 19
Biosignal-based co-adaptive user-machine interfaces for motor control
Madduri, M. M., Burden, S. A., & Orsborn, A. L. (2023) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2023.100462 · Cited by 22
A Brain-Controlled Quadruped Robot: A Proof-of-Concept Demonstration
Kosmyna, N., Hauptmann, E., & Hmaidan, Y. (2023) · Sensors · doi:10.3390/s24010080 · Cited by 19
Alawieh, H., Liu, D. H., Madera, J., Kumar, S., Rácz, F. S., Fey, A. M., & Millán, J. D. R. (2025) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2418920122 · Cited by 20
Measurement of Wireless Link for Brain–Machine Interface Systems Using Human-Head Equivalent Liquid
Moradi, E., Björninen, T., Sydanheimo, L. T., Carmena, J. M., Rabaey, J. M., & Ukkonen, L. (2013) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2013.2283737 · Cited by 19
Asymmetric Sensory-Motor Regeneration of Transected Peripheral Nerves Using Molecular Guidance Cues
Anand, S., Desai, V. H., Alsmadi, N. Z., Kanneganti, A., Nguyen, D. H., Tran, M., Patil, L. S., Vasudevan, S., Xu, C., Hong, Y., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-14331-x · Cited by 19
Correlation of mRNA Expression and Signal Variability in Chronic Intracortical Electrodes
Falcone, J., Carroll, S. L., Saxena, T. K., Mandavia, D., Clark, A., Yarabarla, V., & Bellamkonda, R. V. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00026 · Cited by 19
Yang, X., Zhang, D., Wang, Y., Feng, J., & Xu, W. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0376-9 · Cited by 19
Brain-Computer Interfaces in Quadriplegic Patients
Lee, M. B., Kramer, D. R., Peng, T. D., Barbaro, M. F., Liu, C. Y., Kellis, S., & Lee, B. (2019) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2018.12.009 · Cited by 20
Khorasani, A., Shalchyan, V., & Daliri, M. R. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00350 · Cited by 19
Kim, Y. J., Nam, H. S., Lee, W. H., Seo, H. G., Leigh, J., Oh, B., Bang, M. S., & Kim, S. (2019) · BioMedical Engineering OnLine · doi:10.1186/s12938-019-0633-6 · Cited by 19
Single-cell selectivity and functional architecture of human lateral occipital complex
Decramer, T., Premereur, E., Uytterhoeven, M., Paesschen, W. V., Loon, J. V., Janssen, P., & Theys, T. (2019) · PLoS Biology · doi:10.1371/journal.pbio.3000280 · Cited by 22
Industrial perspectives on brain-computer interface technology
Pulliam, C. L., Stanslaski, S. R., & Denison, T. (2020) · Handbook of clinical neurology · doi:10.1016/b978-0-444-63934-9.00025-1 · Cited by 19
McMullen, D. P., Thomas, T. M., Fifer, M. S., Candrea, D. N., Tenore, F. V., Nickl, R. W., Pohlmeyer, E. A., Coogan, C. G., Osborn, L. E., Schiavi, A. J., et al. (2021) · Journal of neurosurgery · doi:10.3171/2020.9.jns202675 · Cited by 20
Adaptive Offset Correction for Intracortical Brain–Computer Interfaces
Homer, M. L., Perge, J. A., Black, M. J., Harrison, M. T., Cash, S. S., & Hochberg, L. R. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2287768 · Cited by 25
Control of Hand Prostheses: A Literature Review
Cloutier, A., & Yang, J. (2013) · ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference (IDETC/CIE) · doi:10.1115/detc2013-13349 · Cited by 19
Ahmadi, N., Adiono, T., Purwarianti, A., Constandinou, T. G., & Bouganis, C.-S. (2022) · IEEE Access · doi:10.1109/access.2022.3159225 · Cited by 18
Short report: surgery for implantable brain-computer interface assisted by robotic navigation system
Jiang, H., Wang, R., Zheng, Z., Zhu, J., Qi, Y., Xu, K., & Zhang, J. (2022) · Acta Neurochirurgica · doi:10.1007/s00701-022-05235-5 · Cited by 18
Jeon, B. B., Fuchs, T. A. E., Chase, S. M., & Kuhlman, S. J. (2022) · Nature Communications · doi:10.1038/s41467-022-31440-y · Cited by 18
Structural, Functional, and Genetic Changes Surrounding Electrodes Implanted in the Brain
Gupta, B., Saxena, A., Perillo, M. L., Wade-Kleyn, L. C., Thompson, C. H., & Purcell, E. K. (2024) · Accounts of Chemical Research · doi:10.1021/acs.accounts.4c00057 · Cited by 19
RETRACTED: Decoding thoughts, encoding ethics: A narrative review of the BCI-AI revolution
Rudroff, T. (2024) · Brain Research · doi:10.1016/j.brainres.2024.149423 · Cited by 18
RetractedYin, M., Li, H., Bull, C. W., Borton, D. A., Aceros, J. C., Larson, L. E., & Nurmikko, A. V. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610199 · Cited by 18
Wang, Y., Shé, X., Liao, Y., Li, H., Zhang, Q., Zhang, S., Zheng, X., & Príncipe, J. C. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2500585 · Cited by 18
Schaeffer, M.-C., & Aksenova, T. (2016) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2017.03.002 · Cited by 18
Towards Real-Time, Continuous Decoding of Gripping Force From Deep Brain Local Field Potentials
Shah, S. A., Tan, H., Tinkhauser, G., & Brown, P. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2837500 · Cited by 18
Intelligent Multimodal Framework for Human Assistive Robotics Based on Computer Vision Algorithms
Ivorra, E., Ortega, M., Catalan, J. M., Ezquerro, S., Lledó, L. D., García-Aracil, N., & Alcañíz, M. (2018) · Sensors · doi:10.3390/s18082408 · Cited by 18
Age-dependent differences in learning to control a robot arm using a body-machine interface
Ranganathan, R., Lee, M.-H., Padmanabhan, M. R., Aspelund, S., Kagerer, F. A., & Mukherjee, R. (2019) · Scientific Reports · doi:10.1038/s41598-018-38092-3 · Cited by 18
Maiolo, L., Polese, D., & Convertino, A. (2019) · Advances in Physics X · doi:10.1080/23746149.2019.1664319 · Cited by 20
Quick, K. M., Weiss, J. M., Clemente, F., Gaunt, R. A., & Collinger, J. L. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175926 · Cited by 18
Self-citationDatta-Chaudhuri, T., Zanos, T. P., Chang, E. H., Olofsson, P. S., Bickel, S., Bouton, C. E., Grande, D. A., Rieth, L. W., Aranow, C. B., Bloom, O., et al. (2021) · Bioelectronic Medicine · doi:10.1186/s42234-021-00068-6 · Cited by 18
Self-citationWolpaw, J. R., & Boulay, C. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9780511995583.041 · Cited by 18
Modulation Depth Estimation and Variable Selection in State-Space Models for Neural Interfaces
Malik, W. Q., Hochberg, L. R., Donoghue, J. P., & Brown, E. N. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2360393 · Cited by 18
Debnath, S., Prins, N. W., Pohlmeyer, E. A., Mylavarapu, R. V., Geng, S., Sanchez, J. C., & Prasad, A. (2018) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aada67 · Cited by 18
Wang, M., Li, G., Jiang, S., Wei, Z., Hu, J. Z., Chen, L., & Zhang, D. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9987 · Cited by 18
Concerns in the Blurred Divisions Between Medical and Consumer Neurotechnology
Paek, A. Y., Brantley, J. A., Evans, B. J., & Contreras-Vidal, J. L. (2020) · IEEE Systems Journal · doi:10.1109/jsyst.2020.3032609 · Cited by 22
Dynamic Ensemble Modeling Approach to Nonstationary Neural Decoding in Brain-Computer InterfacesPreprint
Qi, Y., Liu, B., Wang, Y., & Pan, G. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1911.00714 · Cited by 18
The potential power of Neuralink – how brain-machine interfaces can revolutionize medicine
Kumar, R., Waisberg, E., Ong, J., & Lee, A. G. (2025) · Expert Review of Medical Devices · doi:10.1080/17434440.2025.2498457 · Cited by 20
Ahmed, B., Khan, S., Lim, H., & Ku, J. H. (2025) · Electronics · doi:10.3390/electronics14030491 · Cited by 18
Feature-Selection-Based Transfer Learning for Intracortical Brain–Machine Interface Decoding
Zhang, P., Li, W., Ma, X., He, J., Huang, J., & Li, Q. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3034234 · Cited by 17
Robust neural decoding by kernel regression with Siamese representation learning
Li, Y., Qi, Y., Wang, Y., Wang, Y., Xu, K., & Pan, G. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac2c4e · Cited by 18
Workshops of the eighth international brain–computer interface meeting: BCIs: the next frontier
Huggins, J. E., Krusienski, D. J., Vansteensel, M. J., Valeriani, D., Thelen, A., Stavisky, S. D., Norton, J. J. S., Nijholt, A., Müller-Putz, G., Kosmyna, N., et al. (2022) · Brain-Computer Interfaces · doi:10.1080/2326263x.2021.2009654 · Cited by 18
Srisrisawang, N., & Müller-Putz, G. (2022) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2022.830221 · Cited by 18
Neuromotor prosthetic to treat stroke-related paresis: N-of-1 trial
Serruya, M. D., Napoli, A., Satterthwaite, N., Kardine, J., McCoy, J., Grampurohit, N., Talekar, K. S., Middleton, D. M., Mohamed, F. B., Kogan, M., et al. (2022) · Communications Medicine · doi:10.1038/s43856-022-00105-8 · Cited by 17
Impact of dataset size and long-term ECoG-based BCI usage on deep learning decoders performance
Śliwowski, M., Martin, M., Souloumiac, A., Blanchart, P., & Aksenova, T. (2023) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2023.1111645 · Cited by 20
Neuronal Spiking Responses to Direct Electrical Microstimulation in the Human Cortex
Youssef, D., Wittig, J. H., Jackson, S. N., Inati, S. K., & Zaghloul, K. A. (2023) · Journal of Neuroscience · doi:10.1523/jneurosci.1666-22.2023 · Cited by 17
Application of advanced biosensors in nervous system diseases
Meng, Z., Zhang, Y., Lu, Y., Yuan, F., Wang, J., Chen, J., Liu, J., Wang, G., & Zang, G. (2024) · Interdisciplinary medicine · doi:10.1002/inmd.20240024 · Cited by 17
Recapitulating Flesh with Silicon and Steel: Advancements in Upper Extremity Robotic Prosthetics
Lee, B., Attenello, F. J., Liu, C. Y., McLoughlin, M. P., & Apuzzo, M. L. J. (2014) · World Neurosurgery · doi:10.1016/j.wneu.2014.03.012 · Cited by 17
Noninvasive control of a robotic arm in multiple dimensions using scalp electroencephalogram
Baxter, B., Decker, A., & He, B. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6695867 · Cited by 17
Design and optimization of mm-size implantable and wearable on-body antennas for biomedical systems
Amendola, S., Moradi, E., Koski, K., Björninen, T., Sydanheimo, L. T., Ukkonen, L., Rabaey, J. M., & Rahmat‐Samii, Y. (2014) · European Conference on Antennas and Propagation · doi:10.1109/eucap.2014.6901807 · Cited by 17
Schroeder, K. E., Irwin, Z. T., Bullard, A. J., Thompson, D. E., Bentley, J. N., Stacey, W. C., Patil, P. G., & Chestek, C. A. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa7329 · Cited by 17
Khorasani, A., Foodeh, R., Shalchyan, V., & Daliri, M. R. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2751579 · Cited by 17
HD-EEG Based Classification of Motor-Imagery Related Activity in Patients With Spinal Cord Injury
Höller, Y., Thomschewski, A. C., Uhl, A., Bathke, A. C., Nardone, R., Leis, S., Trinka, E., & Höller, P. (2018) · Frontiers in Neurology · doi:10.3389/fneur.2018.00955 · Cited by 17
Real-time Closed Loop Neural Decoding on a Neuromorphic chip
Shaikh, S., So, R. Q., Sibindi, T. M., Libedinsky, C., & Basu, A. (2019) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2019.8717122 · Cited by 17
Real-Time Performance of a Tactile Neuroprosthesis on Awake Behaving Rats
Öztürk, S., Devecıoğlu, İ., Beygi, M., Atasoy, A., Mutlu, S., Özkan, M., & Güçlü, B. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2910320 · Cited by 17
Dubaniewicz, M. T., Eles, J. R., Lam, S., Song, S., Cambi, F., Sun, D., Wellman, S. M., & Kozai, T. D. Y. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abe8f1 · Cited by 17
Brain-Computer Interface Use to Control Military Weapons and Tools
Czech, A. (2021) · Advances in intelligent systems and computing · doi:10.1007/978-3-030-72254-8_20 · Cited by 17
Metadata
- Authors
- Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B.
- Affiliations
- University of Pittsburgh (US)
- Corresponding author
- Schwartz, Andrew B
- ORCID
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2013-02
- Volume
- 381
- Issue
- 9866
- Pages
- 557-564
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- PMC
- PMC3641862
- OpenAlex
- W2144910141
- Cited by
- 1,848
- References
- 31
- Citations by year
- 2026: 87 · 2025: 120 · 2024: 120 · 2023: 140 · 2022: 123 · 2021: 143 · 2020: 157 · 2019: 143 · 2018: 147 · 2017: 129 · 2016: 145 · 2015: 144 · 2014: 158 · 2013: 90
- FWCI
- 64.30
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- U.S. Department of Defense
- University of Pittsburgh
- National Institutes of Health (UL1TR000005, 5r01ns050256-05, KL2TR000146)
- Defense Advanced Research Projects Agency
- National Institute of Neurological Disorders and Stroke (RC1NS070311, R01-NS050256)
- National Center for Advancing Translational Sciences
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- brain-computer interface, tetraplegia, intracortical microelectrodes, motor cortex, upper limb function, reach-to-grasp, upper limb paralysis, activities of daily living, prosthetic control
- MeSH terms
- Arm, Artificial Limbs, Female, Humans, Microelectrodes, Middle Aged, Psychomotor Performance, Quadriplegia, Hand Strength, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review