The DOI matches its Crossref record; 30 of the 31 references it cites were found in a registry or an index.
High-performance neuroprosthetic control by an individual with tetraplegia
Open accessAbstract
Background Paralysis or amputation of an arm results in the loss of the ability to orient the hand and grasp, manipulate, and carry objects, functions that are essential for activities of daily living. Brain-machine interfaces could provide a solution to restoring many of these lost functions. We therefore tested whether an individual with tetraplegia could rapidly achieve neurological control of a high-performance prosthetic limb using this type of an interface.Methods We implanted two 96-channel intracortical microelectrodes in the motor cortex of a 52-year-old individual with tetraplegia. Brain-machine-interface training was done for 13 weeks with the goal of controlling an anthropomorphic prosthetic limb with seven degrees of freedom (three-dimensional translation, three-dimensional orientation, one-dimensional grasping). The participant's ability to control the prosthetic limb was assessed with clinical measures of upper limb function. This study is registered with ClinicalTrials.gov, NCT01364480.Findings The participant was able to move the prosthetic limb freely in the three-dimensional workspace on the second day of training. After 13 weeks, robust seven-dimensional movements were performed routinely. Mean success rate on target-based reaching tasks was 91·6% (SD 4·4) versus median chance level 6·2% (95% CI 2·0-15·3). Improvements were seen in completion time (decreased from a mean of 148 s [SD 60] to 112 s [6]) and path efficiency (increased from 0·30 [0·04] to 0·38 [0·02]). The participant was also able to use the prosthetic limb to do skilful and coordinated reach and grasp movements that resulted in clinically significant gains in tests of upper limb function. No adverse events were reported.Interpretation With continued development of neuroprosthetic limbs, individuals with long-term paralysis could recover the natural and intuitive command signals for hand placement, orientation, and reaching, allowing them to perform activities of daily living.Funding Defense Advanced Research Projects Agency, National Institutes of Health, Department of Veterans Affairs, and UPMC Rehabilitation Institute.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“First, using the same fundamental neural decoding and control methods, two participants have achieved similar scores on functional tasks with vision alone (5, 6, 28).”
From A brain-computer interface that evokes tactile sensations improves robotic arm control (2021) · cites this paper as [6]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The flexibility of ConvNets might also be a limitation in some brain‐signal decoding scenarios. For example if the user of a brain–computer interface should learn to adapt her or his brain signals to the decoding model, a simpler feature‐based model might yield better results.”
From Deep learning with convolutional neural networks for EEG decoding and visualization (2017) · cites this paper as Collinger et al., 2013
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“ICMS can also be employed to deliver localized tactile percepts with natural features as well as in human-brain-computer interface applications for better control using area S1 (Collinger et al., 2013; Wodlinger et al., 2015; Downey et al., 2016).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Collinger et al., 2013
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“For depth electrodes, there is also the potential to implant multiple locations, widening coverage [21].”
From Ethical considerations for the use of brain–computer interfaces for cognitive enhancement (2024) · cites this paper as [21]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Prior BCI studies have shown that the motor intention for gross motor skills, such as reaching, grasping or moving a computer cursor, remains neurally encoded in motor cortex after paralysis1–7.”
From High-performance brain-to-text communication via handwriting (2021) · cites this paper as [2]
The cited source says what the claim attributes to it.
In the citing paper
“and has enabled the highest BCI performance to date compared to other recording technologies (EEG, ECoG) for restoring communication7, arm control2,5, and general-purpose computer use39.”
From High-performance brain-to-text communication via handwriting (2021) · cites this paper as [2]
The cited source says what the claim attributes to it.
In the citing paper
“By combining these innovations, it is now possible for a human patient to perform tasks with a bionic arm by thoughts alone (Collinger et al., 2013; Wodlinger et al., 2015).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Collinger et al., 2013
In the citing paper
“Currently, all reported BMI experiments with human patients [26, 35, 57, 58, 150] require the subjects tethered percutaneously to a bench-top computer for neural signal acquisition and decoding.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [26]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal Population Coding of Movement Direction
Georgopoulos, A. P., Schwartz, A. B., & Kettner, R. E. (1986) · Science · doi:10.1126/science.3749885 · Cited by 3,219
Self-citationReach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Generalized Inverses, Ridge Regression, Biased Linear Estimation, and Nonlinear Estimation
Marquardt, D. W. (1970) · Technometrics · doi:10.2307/1267205 · Cited by 2,284
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Self-citationDirect Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,542
Self-citationLyle, R. C. (1981) · International Journal of Rehabilitation Research · doi:10.1097/00004356-198112000-00001 · Cited by 1,335
Postural Hand Synergies for Tool Use
Santello, M., Flanders, M., & Soechting, J. F. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-23-10105.1998 · Cited by 1,215
(1950) · Archives of Pediatrics and Adolescent Medicine · doi:10.1001/archpedi.1950.04040020187020 · Cited by 1,108
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Motor Cortical Representation of Speed and Direction During Reaching
Moran, D. W., & Schwartz, A. B. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.82.5.2676 · Cited by 809
Self-citation
Cited by
Sorted by citations
Items 301–400 of 1,004
Grimm, F., Walter, A., Spüler, M., Naros, G., Rosenstiel, W., & Gharabaghi, A. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00367 · Cited by 68
In vivo spatiotemporal dynamics of NG2 glia activity caused by neural electrode implantation
Wellman, S. M., & Kozai, T. D. Y. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.02.037 · Cited by 67
Dendritic calcium signals in rhesus macaque motor cortex drive an optical brain-computer interface
Trautmann, E. M., O’Shea, D. J., Sun, X., Marshel, J. H., Crow, A., Hsueh, B., Vesuna, S. S., Cofer, L. B., Bohner, G., Allen, W., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-23884-5 · Cited by 68
Multi-Channel Neural Recording Implants: A Review
Hashemi Noshahr, F., Nabavi, M., & Sawan, M. (2020) · Sensors · doi:10.3390/s20030904 · Cited by 66
Sponheim, C., Papadourakis, V., Collinger, J. L., Downey, J., Weiss, J., Pentousi, L., Elliott, K., & Hatsopoulos, N. G. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac3eaf · Cited by 66
Self-citationPerformance sustaining intracortical neural prostheses
Nuyujukian, P., Kao, J. C., Fan, J. M., Stavisky, S. D., Ryu, S. I., & Shenoy, K. V. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/6/066003 · Cited by 68
Krämer, P., & Bressan, P. (2015) · Perspectives on Psychological Science · doi:10.1177/1745691615583131 · Cited by 68
Classification of different reaching movements from the same limb using EEG
Shiman, F., López‐Larraz, E., Sarasola-Sanz, A., Irastorza-Landa, N., Spüler, M., Birbaumer, N., & Ramos‐Murguialday, A. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa70d2 · Cited by 67
Bullard, A. J., Hutchison, B. C., Lee, J., Chestek, C. A., & Patil, P. G. (2020) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.13069 · Cited by 65
Moly, A., Costecalde, T., Martel, F., Martin, M., Larzabal, C., Karakas, S., Verney, A., Charvet, G., Chabardes, S., Benabid, A. L., et al. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac59a0 · Cited by 65
Welle, E. J., Patel, P. R., Woods, J. E., Petrossians, A., della Valle, E., Vega-Medina, A., Richie, J. M., Cai, D., Weiland, J. D., & Chestek, C. A. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab8343 · Cited by 68
Bockbrader, M. A., Annetta, N. V., Friedenberg, D. A., Schwemmer, M. A., Skomrock, N. D., Colachis, S. C., Zhang, M., Bouton, C. E., Rezai, A. R., Sharma, G., et al. (2019) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2018.07.445 · Cited by 65
Ethical considerations for the use of brain–computer interfaces for cognitive enhancement
Gordon, E. C., & Seth, A. K. (2024) · PLOS Biology · doi:10.1371/journal.pbio.3002899 · Cited by 64
Brain-Computer-Spinal Interface Restores Upper Limb Function After Spinal Cord Injury
Samejima, S., Khorasani, A., Ranganathan, V. N., Nakahara, J., Tolley, N. M., Boissenin, A., Shalchyan, V., Daliri, M. R., Smith, J. R., & Moritz, C. T. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3090269 · Cited by 69
Long-term intracortical microelectrode array performance in a human: a 5 year retrospective analysis
Colachis, S. C., Dunlap, C. F., Annetta, N. V., Tamrakar, S., Bockbrader, M. A., & Friedenberg, D. A. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac1add · Cited by 67
Cajigas, I., Davis, K., Meschede-Krasa, B., Prins, N. W., Gallo, S., Naeem, J., Palermo, A. E., Wilson, A., Guerra, S., Parks, B. A., et al. (2021) · Brain Communications · doi:10.1093/braincomms/fcab248 · Cited by 65
A BMI-based occupational therapy assist suit: asynchronous control by SSVEP
Sakurada, T., Kawase, T., Takano, K., Komatsu, T., & Kansaku, K. (2013) · Frontiers in Neuroscience · doi:10.3389/fnins.2013.00172 · Cited by 64
Spüler, M., Walter, A., Ramos‐Murguialday, A., Naros, G., Birbaumer, N., Gharabaghi, A., Rosenstiel, W., & Bogdan, M. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/6/066008 · Cited by 64
Motor cortical activity changes during neuroprosthetic-controlled object interaction
Downey, J. E., Brane, L., Gaunt, R. A., Tyler-Kabara, E. C., Boninger, M. L., & Collinger, J. L. (2017) · Scientific Reports · doi:10.1038/s41598-017-17222-3 · Cited by 63
Self-citationTing, J. E., Vecchio, A. D., Sarma, D., Verma, N., Colachis, S. C., Annetta, N. V., Collinger, J. L., Farina, D., & Weber, D. J. (2021) · Journal of Neurophysiology · doi:10.1152/jn.00220.2021 · Cited by 68
Self-citationRochford, A. E., Carnicer‐Lombarte, A., Kawan, M., Jin, A. T., Hilton, S., Curto, V. F., Rutz, A. L., Moreau, T., Kotter, M., Malliaras, G. G., et al. (2023) · Science Advances · doi:10.1126/sciadv.add8162 · Cited by 63
Deeny, S. P., Chicoine, C. L., Hargrove, L. J., Parrish, T. B., & Jayaraman, A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0112091 · Cited by 62
Ethical issues in neuroprosthetics
Glannon, W. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/021002 · Cited by 63
Volitional Modulation of Primary Visual Cortex Activity Requires the Basal Ganglia
Neely, R., Koralek, A. C., Athalye, V. R., Costa, R. M., & Carmena, J. M. (2018) · Neuron · doi:10.1016/j.neuron.2018.01.051 · Cited by 62
A High-Performance Keyboard Neural Prosthesis Enabled by Task Optimization
Nuyujukian, P., Fan, J. M., Kao, J. C., Ryu, S. I., & Shenoy, K. V. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2354697 · Cited by 61
Feedback control policies employed by people using intracortical brain–computer interfaces
Willett, F. R., Pandarinath, C., Jarosiewicz, B., Murphy, B. A., Memberg, W. D., Blabe, C. H., Saab, J., Walter, B. L., Sweet, J. A., Miller, J. P., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/14/1/016001 · Cited by 67
Self-recalibrating classifiers for intracortical brain–computer interfaces
Bishop, W. E., Chestek, C. A., Gilja, V., Nuyujukian, P., Foster, J. D., Ryu, S. I., Shenoy, K. V., & Yu, B. M. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026001 · Cited by 64
Progress in the Field of Micro-Electrocorticography
Shokoueinejad, M., Park, D., Jung, Y. H., Brodnick, S. K., Novello, J., Dingle, A. M., Swanson, K. I., Baek, D.-H., Suminski, A. J., Lake, W. B., et al. (2019) · Micromachines · doi:10.3390/mi10010062 · Cited by 65
Liao, X., Wang, W., Wang, L., Jin, H., Shu, L., Xu, X., & Zheng, Y. (2020) · Nano Energy · doi:10.1016/j.nanoen.2020.105548 · Cited by 63
Self-citationBrain–Machine Interface Control Algorithms
Shanechi, M. M. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2639501 · Cited by 61
The effect of chronic intracortical microstimulation on the electrode–tissue interface
Chen, K. H., Dammann, J. F., Boback, J. L., Tenore, F. V., Otto, K. J., Gaunt, R. A., & Bensmaia, S. J. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026004 · Cited by 59
Muscle synergies evoked by microstimulation are preferentially encoded during behavior
Overduin, S. A., d’Avella, A., Carmena, J. M., & Bizzi, E. (2014) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2014.00020 · Cited by 61
Vogel, J., Haddadin, S., Jarosiewicz, B., Simeral, J. D., Bacher, D., Hochberg, L. R., Donoghue, J. P., & van der Smagt, P. (2015) · The International Journal of Robotics Research · doi:10.1177/0278364914561535 · Cited by 64
A cortical–spinal prosthesis for targeted limb movement in paralysed primate avatars
Shanechi, M. M., Hu, R. C., & Williams, Z. M. (2014) · Nature Communications · doi:10.1038/ncomms4237 · Cited by 62
Bidirectional brain-computer interfaces
Hughes, C. L., Herrera, A. J., Gaunt, R. A., & Collinger, J. L. (2020) · Handbook of clinical neurology · doi:10.1016/b978-0-444-63934-9.00013-5 · Cited by 65
Self-citationElectrical Stimulation as a Tool to Promote Plasticity of the Injured Spinal Cord
Jack, A. S., Hurd, C., Martin, J. H., & Fouad, K. (2020) · Journal of Neurotrauma · doi:10.1089/neu.2020.7033 · Cited by 58
Defining Surgical Terminology and Risk for Brain Computer Interface Technologies
Leuthardt, E. C., Moran, D. W., & Mullen, T. R. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.599549 · Cited by 62
Shared Control of Bimanual Robotic Limbs With a Brain-Machine Interface for Self-Feeding
Handelman, D. A., Osborn, L. E., Thomas, T. M., Badger, A. R., Thompson, M. C., Nickl, R. W., Anaya, M. A., Wormley, J. M., Cantarero, G. L., McMullen, D. P., et al. (2022) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2022.918001 · Cited by 61
Kosnoff, J., Yu, K., Liu, C., & He, B. (2024) · Nature Communications · doi:10.1038/s41467-024-48576-8 · Cited by 64
Wang, D., Zhang, Q., Li, Y., Wang, Y., Zhu, J., Zhang, S., & Zheng, X. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/036009 · Cited by 60
Yang, Y., Boling, S., & Mason, A. J. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2679032 · Cited by 58
Bioinspired Underwater Propulsors
Buren, T. W. V., Floryan, D., & Smits, A. J. (2020) · Cambridge University Press eBooks · doi:10.1017/9781139058995.006 · Cited by 57
Young, D. R., Willett, F. R., Memberg, W. D., Murphy, B., Walter, B. L., Sweet, J., Miller, J. P., Hochberg, L. R., Kirsch, R. F., & Ajiboye, A. B. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9ee8 · Cited by 58
Yang, X., Zhang, H., Cao, L., Shu, X., & Zhang, D. (2020) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2020.3034826 · Cited by 56
Brain–computer interfaces: a powerful tool for scientific inquiry
Wander, J. D., & Rao, R. P. N. (2014) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2013.11.013 · Cited by 59
Inner speech in motor cortex and implications for speech neuroprostheses
Kunz, E. M., Abramovich Krasa, B., Kamdar, F., Avansino, D. T., Hahn, N., Yoon, S., Singh, A., Nason-Tomaszewski, S. R., Card, N. S., Jude, J. J., et al. (2025) · Cell · doi:10.1016/j.cell.2025.06.015 · Cited by 55
Goss-Varley, M., Dona, K. R., McMahon, J. A., Shoffstall, A. J., Ereifej, E. S., Lindner, S. C., & Capadona, J. R. (2017) · Scientific Reports · doi:10.1038/s41598-017-15623-y · Cited by 57
Artifact-free recordings in human bidirectional brain–computer interfaces
Weiss, J. M., Flesher, S. N., Franklin, R. K., Collinger, J. L., & Gaunt, R. A. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae748 · Cited by 60
Self-citationAn Analysis of Deep Learning Models in SSVEP-Based BCI: A Survey
Xu, D., Tang, F., Li, Y., Zhang, Q., & Feng, X. (2023) · Brain Sciences · doi:10.3390/brainsci13030483 · Cited by 57
Corticospinal neuroprostheses to restore locomotion after spinal cord injury
Borton, D. A., Bonizzato, M., Beauparlant, J., DiGiovanna, J., Moraud, E. M., Wenger, N., Евгеньевич, М. П., Minev, I. R., Lacour, S. P., Millán, J. D. R., et al. (2013) · Neuroscience Research · doi:10.1016/j.neures.2013.10.001 · Cited by 60
Local field potentials in primate motor cortex encode grasp kinetic parameters
Milekovic, T., Truccolo, W., Grün, S., Riehle, A., & Brochier, T. G. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.04.008 · Cited by 55
Mahan, M. Y., & Georgopoulos, A. P. (2013) · Frontiers in Neural Circuits · doi:10.3389/fncir.2013.00092 · Cited by 55
Dziemian, S., Abbott, W. W., & Faisal, A. A. (2016) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2016.7523807 · Cited by 55
Findlater, S. E., & Dukelow, S. P. (2016) · Journal of Motor Behavior · doi:10.1080/00222895.2016.1219303 · Cited by 55
Interfacing to the brain’s motor decisions
Mirabella, G., & Lebedev, M. (2016) · Journal of Neurophysiology · doi:10.1152/jn.00051.2016 · Cited by 55
Meng, J., Streitz, T. D., Gulachek, N., Suma, D., & He, B. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2872855 · Cited by 59
Batzianoulis, I., Iwane, F., Wei, S., Correia, C., Chavarriaga, R., Millán, J. D. R., & Billard, A. (2021) · Communications Biology · doi:10.1038/s42003-021-02891-8 · Cited by 57
Chronic impedance spectroscopy of an endovascular stent-electrode array
Opie, N. L., John, S. E., Rind, G. S., Ronayne, S. M., Grayden, D. B., Burkitt, A. N., May, C. N., O'Brien, T. J., & Oxley, T. J. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046020 · Cited by 54
Neural control of finger movement via intracortical brain–machine interface
Irwin, Z. T., Schroeder, K. E., Vu, P. P., Bullard, A. J., Tat, D. M., Nu, C. S., Vaskov, A. K., Nason, S. R., Thompson, D. E., Bentley, J. N., et al. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa80bd · Cited by 56
Hiremath, S. V., Chen, W., Wang, W., Foldes, S., Yang, Y., Tyler-Kabara, E. C., Collinger, J. L., & Boninger, M. L. (2015) · Frontiers in Integrative Neuroscience · doi:10.3389/fnint.2015.00040 · Cited by 53
Self-citationSense of agency for intracortical brain–machine interfaces
Serino, A., Bockbrader, M. A., Bertoni, T., Colachis, S. C., Solcà, M., Dunlap, C. F., Eipel, K., Ganzer, P. D., Annetta, N., Sharma, G., et al. (2022) · Nature Human Behaviour · doi:10.1038/s41562-021-01233-2 · Cited by 54
BCI Control of a Robotic Arm Based on SSVEP With Moving Stimuli for Reach and Grasp Tasks
Ai, J., Meng, J., Mai, X., & Zhu, X. (2023) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2023.3277612 · Cited by 58
Backscattering Neural Tags for Wireless Brain-Machine Interface Systems
Moradi, E., Amendola, S., Björninen, T., Sydanheimo, L. T., Carmena, J. M., Rabaey, J. M., & Ukkonen, L. (2014) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2014.2384038 · Cited by 55
O’Shea, D. J., Trautmann, E. M., Chandrasekaran, C., Stavisky, S. D., Kao, J. C., Sahani, M., Ryu, S. I., Deisseroth, K. A., & Shenoy, K. V. (2016) · Experimental Neurology · doi:10.1016/j.expneurol.2016.08.003 · Cited by 54
Çeltikçi, E. (2017) · Turkish Neurosurgery · doi:10.5137/1019-5149.jtn.20059-17.1 · Cited by 53
Greenwald, E., Masters, M. R., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1429-x · Cited by 53
Recording and decoding for neural prostheses
Warren, D. J., Kellis, S., Nieveen, J. G., Wendelken, S. M., Dantas, H., Davis, T. S., Hutchinson, D. T., Normann, R. A., Clark, G. A., & Mathews, V. J. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2507180 · Cited by 52
Nason, S. R., Mender, M. J., Vaskov, A. K., Willsey, M. S., Kumar, N. G., Kung, T. A., Patil, P. G., & Chestek, C. A. (2021) · Neuron · doi:10.1016/j.neuron.2021.08.009 · Cited by 55
Conductive Polymer Enabled Biostable Liquid Metal Electrodes for Bioelectronic Applications
Lim, T., Kim, M., Akbarian, A., Kim, J., Tresco, P. A., & Zhang, H. (2022) · Advanced Healthcare Materials · doi:10.1002/adhm.202102382 · Cited by 53
Creating new functional circuits for action via brain-machine interfaces
Orsborn, A. L., & Carmena, J. M. (2013) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2013.00157 · Cited by 55
A Spatio-Temporal Fractal Model for a CPS Approach to Brain-Machine-Body Interfaces
Xue, Y., Rodríguez, S. H., & Bogdan, P. (2016) · Design, Automation, and Test in Europe · doi:10.3850/9783981537079_0502 · Cited by 52
Independent Mobility Achieved through a Wireless Brain-Machine Interface
Libedinsky, C., So, R. Q., Xu, Z., Kyar, T. K., Ho, D., Lim, C., Chan, L., Chua, Y., Yao, L., Cheong, J. H., et al. (2016) · PLoS ONE · doi:10.1371/journal.pone.0165773 · Cited by 52
Degenhart, A. D., Hiremath, S. V., Yang, Y., Foldes, S. T., Collinger, J. L., Boninger, M. L., Tyler‐Kabara, E. C., & Wang, W. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9bfb · Cited by 53
Self-citationCollinger, J. L., Gaunt, R. A., & Schwartz, A. B. (2018) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2018.11.005 · Cited by 53
Self-citationPrincipled BCI Decoder Design and Parameter Selection Using a Feedback Control Model
Willett, F. R., Young, D. R., Murphy, B. A., Memberg, W. D., Blabe, C. H., Pandarinath, C., Stavisky, S. D., Rezaii, P. G., Saab, J., Walter, B. L., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-44166-7 · Cited by 54
Decoding upper limb residual muscle activity in severe chronic stroke
Ramos‐Murguialday, A., García‐Cossio, E., Walter, A., Cho, W., Broetz, D., Bogdan, M., Cohen, L. G., & Birbaumer, N. (2014) · Annals of Clinical and Translational Neurology · doi:10.1002/acn3.122 · Cited by 51
Perel, S., Sadtler, P. T., Oby, E. R., Ryu, S. I., Tyler‐Kabara, E. C., Batista, A. P., & Chase, S. M. (2015) · Journal of Neurophysiology · doi:10.1152/jn.00293.2014 · Cited by 55
Self-citationClinical guidelines for neurorestorative therapies in spinal cord injury (2021 China version)
Guo, X., Feng, Y., Sun, T., Feng, S., Tang, J., Chen, L., Cao, X., Lin, H., He, X., Li, M.-H., et al. (2021) · Journal of Neurorestoratology · doi:10.26599/jnr.2021.9040003 · Cited by 50
Learning to control a BMI-driven wheelchair for people with severe tetraplegia
Tonin, L., Perdikis, S., Kuzu, T. D., Pardo, J., Orset, B., Lee, K., Aach, M., Schildhauer, T. A., Martínez, R., & Millán, J. D. R. (2022) · iScience · doi:10.1016/j.isci.2022.105418 · Cited by 53
Language Model Applications to Spelling with Brain-Computer Interfaces
Mora-Cortes, A., Manyakov, N. V., Chumerin, N., & Hulle, M. M. V. (2014) · Sensors · doi:10.3390/s140405967 · Cited by 50
Acquisition of Neural Action Potentials Using Rapid Multiplexing Directly at the Electrodes
Sharma, M., Gardner, A. T., Strathman, H. J., Warren, D. J., Silver, J., & Walker, R. M. (2018) · Micromachines · doi:10.3390/mi9100477 · Cited by 52
Plasticity and Adaptation in Neuromorphic Biohybrid Systems
George, R., Chiappalone, M., Giugliano, M., Levi, T., Vassanelli, S., Partzsch, J., & Mayr, C. (2020) · iScience · doi:10.1016/j.isci.2020.101589 · Cited by 56
Patel, P. R., Welle, E. J., Letner, J. G., Shen, H., Bullard, A. J., Caldwell, C. M., Vega-Medina, A., Richie, J. M., Thayer, H. E., Patil, P. G., et al. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acab86 · Cited by 49
Lee, S., Thunemann, M., Lee, K., Cleary, D. R., Tonsfeldt, K. J., Oh, H., Azzazy, F., Tchoe, Y., Bourhis, A. M., Hossain, L., et al. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202112045 · Cited by 50
Saway, B. F., Palmer, C., Hughes, C. L., Triano, M. J., Suresh, R. E., Gilmore, J., George, M. S., Kautz, S. A., & Rowland, N. C. (2024) · Neurotherapeutics · doi:10.1016/j.neurot.2024.e00337 · Cited by 53
Brain–machine interface: closer to therapeutic reality?
Courtine, G., Micera, S., DiGiovanna, J., & Millán, J. D. R. (2012) · The Lancet · doi:10.1016/s0140-6736(12)62164-3 · Cited by 51
Combat casualty care and lessons learned from the past 100 years of war
Bradley, M. J., Nealeigh, M. D., Oh, J. S., Rothberg, P., Elster, E. A., & Rich, N. M. (2017) · Current Problems in Surgery · doi:10.1067/j.cpsurg.2017.02.004 · Cited by 49
Performance of Forearm FMG for Estimating Hand Gestures and Prosthetic Hand Control
Ha, N., Withanachchi, G. P., & Yihun, Y. (2019) · Journal of Bionic Engineering · doi:10.1007/s42235-019-0009-4 · Cited by 51
Mixed Spatial and Movement Representations in the Primate Posterior Parietal Cortex
Hadjidimitrakis, K., Bakola, S., Wong, Y. T., & Hagan, M. A. (2019) · Frontiers in Neural Circuits · doi:10.3389/fncir.2019.00015 · Cited by 49
Hammer, J., Fischer, J., Ruescher, J., Schulze-Bonhage, A., Aertsen, A., & Ball, T. (2013) · Frontiers in Neuroscience · doi:10.3389/fnins.2013.00200 · Cited by 49
Adversarial Domain Adaptation for Stable Brain-Machine Interfaces
Farshchian, A., Gallego, J. A., Cohen, J. P., Bengio, Y., Miller, L. E., & Solla, S. A. (2018) · arXiv · doi:10.48550/arxiv.1810.00045 · Cited by 48
Sombeck, J. T., Heye, J. O., Kumaravelu, K., Goetz, S. M., Peterchev, A. V., Grill, W. M., Bensmaı̈a, S. J., & Miller, L. E. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac63e8 · Cited by 50
Bergeron, D., Iorio‐Morin, C., Bonizzato, M., Lajoie, G., Gaucher, N. O., Racine, É., & Weil, A. G. (2023) · Journal of Child Neurology · doi:10.1177/08830738231167736 · Cited by 50
de Oliveira, D. S., Ponfick, M., Braun, D. I., Oßwald, M., Sierotowicz, M., Chatterjee, S., Weber, D. J., Eskofier, B. M., Castellini, C., Farina, D., et al. (2024) · Brain · doi:10.1093/brain/awae088 · Cited by 51
Self-citationLong-term stability of sensitivity to intracortical microstimulation of somatosensory cortex
Callier, T., Schluter, E. W., Tabot, G. A., Miller, L. E., Tenore, F. V., & Bensmaı̈a, S. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/5/056010 · Cited by 48
A collaborative BCI approach to autonomous control of a prosthetic limb system
Katyal, K. D., Johannes, M. S., Kellis, S., Aflalo, T., Klaes, C., McGee, T. G., Para, M. P., Shi, Y., Lee, B., Pejsa, K., et al. (2014) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2014.6974124 · Cited by 48
Autonomy Infused Teleoperation with Application to BCI Manipulation
Mülling, K., Venkatraman, A., Valois, J., Downey, J. E., Weiss, J. M., Javdani, S., Hebert, M., Schwartz, A. B., Collinger, J. L., & Bagnell, A. (2015) · Robotics: Science and Systems · doi:10.15607/rss.2015.xi.039 · Cited by 47
Self-citationCortical Decoding of Individual Finger Group Motions Using ReFIT Kalman Filter
Vaskov, A. K., Irwin, Z. T., Nason, S. R., Vu, P. P., Nu, C. S., Bullard, A. J., Hill, M., North, N., Patil, P. G., & Chestek, C. A. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00751 · Cited by 50
Spatiotemporal patterns of gene expression around implanted silicon electrode arrays
Thompson, C. H., Saxena, A., Heelan, N., Salatino, J. W., & Purcell, E. K. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abf2e6 · Cited by 47
Szymanski, L. J., Kellis, S., Liu, C. Y., Jones, K. T., Andersen, R. A., Commins, D., Lee, B., McCreery, D. B., & Miller, C. A. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac127e · Cited by 48
Metadata
- Authors
- Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B.
- Affiliations
- University of Pittsburgh (US)
- Corresponding author
- Schwartz, Andrew B
- ORCID
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2013-02
- Volume
- 381
- Issue
- 9866
- Pages
- 557-564
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- PMC
- PMC3641862
- OpenAlex
- W2144910141
- Cited by
- 1,848
- References
- 31
- Citations by year
- 2026: 87 · 2025: 120 · 2024: 120 · 2023: 140 · 2022: 123 · 2021: 143 · 2020: 157 · 2019: 143 · 2018: 147 · 2017: 129 · 2016: 145 · 2015: 144 · 2014: 158 · 2013: 90
- FWCI
- 64.30
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- U.S. Department of Defense
- University of Pittsburgh
- National Institutes of Health (UL1TR000005, 5r01ns050256-05, KL2TR000146)
- Defense Advanced Research Projects Agency
- National Institute of Neurological Disorders and Stroke (RC1NS070311, R01-NS050256)
- National Center for Advancing Translational Sciences
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- brain-computer interface, tetraplegia, intracortical microelectrodes, motor cortex, upper limb function, reach-to-grasp, upper limb paralysis, activities of daily living, prosthetic control
- MeSH terms
- Arm, Artificial Limbs, Female, Humans, Microelectrodes, Middle Aged, Psychomotor Performance, Quadriplegia, Hand Strength, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review