Forehead or ear temperature measurement cannot replace rectal measurements, except for screening purposes
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Measuring rectal temperature in children is the gold standard, but ear or forehead measures are less traumatic and faster. The quality of non-invasive devices has improved but concerns remain whether they are reliable enough to substitute rectal thermometers. The aim was to evaluate in a real-life children population whether the forehead or ear temperature measurements could be used in screening to detect fever and if the agreement with the rectal temperature for different age groups is acceptable for clinical use. METHODS: Cross-sectional clinical study comparing temporal and tympanic temperatures to rectal temperature in 0-18-year-old children. The ear thermometer was a Pro 4000 Thermoscan, the temporal Exergen TAT. Rectal temperature ≥ 38.0 °C was defined as fever. RESULTS: Among 995 children, 39% had a fever. The ear thermometer had a significantly greater ability to detect fever than the temporal thermometer (AUC 0.972; 95% CI: 0.963-0.981 versus AUC 0.931; 95% CI: 0.915-0.947, p < 0.0001). Both devices had the lowest sensitivity in the youngest and oldest children, and only the ear thermometer reached a sensitivity above 90% in the 0.5-5-year age group. The Bland-Altman analysis showed that the 95% limits of agreement for the temporal thermometer was between - 1.2 to + 1.5 °C and for the ear thermometer between - 0.97 to + 1.07 °C. CONCLUSIONS: Based on a large sample of children, the temporal measurement of temperature is not currently recommendable, but with the technology used in this study the ear measurement proved useful for screening purposes, especially among children aged 6 months to 5 years. For the exact measurement of temperature, the rectal method is still recommended.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Niven, D. J., Gaudet, J. E., Laupland, K. B., Mrklas, K. J., Roberts, D. J., & Stelfox, H. T. (2015) · Annals of Internal Medicine · doi:10.7326/m15-1150 · Cited by 240
Dodd, S. R., Lancaster, G. A., Craig, J. V., Smyth, R. L., & Williamson, P. R. (2006) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.10.004 · Cited by 90 · cited 1×
“Several reviews have reported disappointing results [2, 10, 11].”
Research works printed but not linked: 17
- El-Radhi AS. Determining fever in children: the search for an ideal thermometer. Br J Nurs (Mark Allen Publishing. 2014;23(2):91–4. · DOI
- Hurwitz B, Brown J, Altmiller G. Improving pediatric temperature measurement in the ED. Am J Nurs. 2015;115(9):48–55. · DOI
- Bahorski J, Repasky T, Ranner D, Fields A, Jackson M, Moultry L, Pierce K, Sandell M. Temperature measurement in pediatrics: a comparison of the rectal method versus the temporal artery method. J Pediatr Nurs. 2012;27(3):243–7. · DOI
- Batra P, Goyal S. Comparison of rectal, axillary, tympanic, and temporal artery thermometry in the pediatric emergency room. Pediatr Emerg Care. 2013;29(1):63–6. · DOI · Paper page
- Isler A, Aydin R, Tutar Guven S, Gunay S. Comparison of temporal artery to mercury and digital temperature measurement in pediatrics. Int Emerg Nurs. 2014;22(3):165–8. · DOI
- El-Radhi AS. Infrared thermometers for assessing fever in children: the ThermoScan PRO 4000 ear thermometer is more reliable than the temporal scanner TAT-500. Evid Based Nurs. 2014;17(4):115. · DOI
- Allegaert K, Casteels K, van Gorp I, Bogaert G. Tympanic, infrared skin, and temporal artery scan thermometers compared with rectal measurement in children: a real-life assessment. Curr Ther Res Clin Exp. 2014;76:34–8. · DOI · Paper page
- Haugan B, Langerud AK, Kalvoy H, Froslie KF, Riise E, Kapstad H. Can we trust the new generation of infrared tympanic thermometers in clinical practice? J Clin Nurs. 2013;22(5-6):698–709. · DOI
- Siberry GK, Diener-West M, Schappell E, Karron RA. Comparison of temple temperatures with rectal temperatures in children under two years of age. Clin Pediatr. 2002;41(6):405–14. · DOI
- Hebbar K, Fortenberry JD, Rogers K, Merritt R, Easley K. Comparison of temporal artery thermometer to standard temperature measurements in pediatric intensive care unit patients. Pediatr Crit Care Med. 2005;6(5):557–61. · DOI · Paper page
- Reynolds M, Bonham L, Gueck M, Hammond K, Lowery J, Redel C, Rodriguez C, Smith S, Stanton A, Sukosd S, et al. Are temporal artery temperatures accurate enough to replace rectal temperature measurement in pediatric ED patients? J Emerg Nurs. 2014;40(1):46–50. · DOI
- Hoffman RJ, Etwaru K, Dreisinger N, Khokhar A, Husk G. Comparison of temporal artery thermometry and rectal thermometry in febrile pediatric emergency department patients. Pediatr Emerg Care. 2013;29(3):301–4. · DOI
- Holzhauer JK, Reith V, Sawin KJ, Yen K. Evaluation of temporal artery thermometry in children 3-36 months old. J Spec Pediatr Nurs. 2009;14(4):239–44. · DOI
- Odinaka KK, Edelu BO, Nwolisa CE, Amamilo IB, Okolo SN. Temporal artery thermometry in children younger than 5 years: a comparison with rectal thermometry. Pediatr Emerg Care. 2014;30(12):867–70. · DOI · Paper page
- Hamilton PA, Marcos LS, Secic M. Performance of infrared ear and forehead thermometers: a comparative study in 205 febrile and afebrile children. J Clin Nurs. 2013;22(17-18):2509–18. · DOI
- Teller J, Ragazzi M, Simonetti GD, Lava SA. Accuracy of tympanic and forehead thermometers in private paediatric practice. Acta Paediatr (Oslo, Norway: 1992). 2014;103(2):e80–3. · DOI · Paper page
- Hanneman SK. Design, analysis, and interpretation of method-comparison studies. AACN Adv Crit Care. 2008;19(2):223–34.
Cited by
Circadian rhythmicity of body temperature and metabolism
Refinetti, R. (2020) · Temperature · doi:10.1080/23328940.2020.1743605 · Cited by 155
Chen, H.-Y., Chen, A., & Chen, C. (2020) · Sensors · doi:10.3390/s20102885 · Cited by 139
“[46] used the rectal temperature as a standard value.”
MethodPecoraro, V., Petri, D., Costantino, G., Squizzato, A., Moja, L., Virgili, G., & Lucenteforte, E. (2021) · Internal and Emergency Medicine · doi:10.1007/s11739-020-02556-0 · Cited by 49
“Mogensen 2018 [48] Cross-sectional Pediatric department Children 995 Rectal, digital Tympanic, infrared Temporal artery, infrared”
Non-contact infrared assessment of human body temperature: The journal Temperature toolbox
Foster, J., Lloyd, A. B., & Havenith, G. (2021) · Temperature · doi:10.1080/23328940.2021.1899546 · Cited by 46
“Therefore, the consensus among hospital-based studies is that Tforehead does not always track Tcore and therefore cannot replace contact methods for an accurate assessment, but it appears that Tforehead is useful for screening purposes, preceding a more invasive contact assessment of Tcore [5,61].”
BackgroundChen, G., Xie, J., Dai, G., Zheng, P., Hu, X., Lu, H., Xu, L., Chen, X., & Chen, X. (2020) · doi:10.1101/2020.03.02.20030148 · Cited by 40
Metadata
- Authors
- Mogensen, C. B., Wittenhoff, L., Fruerhøj, G., & Hansen, S.
- Venue
- BMC Pediatrics
- Published
- 2018-01-26
- Volume
- 18
- Issue
- 1
- Pages
- 15-15
- ISSN
- 1471-2431 (ISSN-L)
- OpenAlex
- W2785001501
- Cited by
- 54
- References
- 3
- FWCI
- 5.11
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Forehead or ear temperature measurement cannot replace rectal measurements, except for screening purposes. https://app.cochat.ai/papers/10.1186/s12887-018-0994-1
- The paper
- Mogensen, C. B., Wittenhoff, L., Fruerhøj, G., & Hansen, S. (2018). Forehead or ear temperature measurement cannot replace rectal measurements, except for screening purposes. BMC Pediatrics. https://doi.org/10.1186/s12887-018-0994-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.