In vitro and in vivo degradation of porous poly(dl-lactic-co-glycolic acid) foams
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
This study investigated the in vitro degradation of porous poly(DL-lactic-co-glycolic acid) (PLGA) foams during a 20-week period in pH 7.4 phosphate-buffered saline (PBS) at 37 degrees C and their in vivo degradation following implantation in rat mesentery for up to 8 weeks. Three types of PLGA 85 : 15 and three types of 50 : 50 foams were fabricated using a solvent-casting, particulate-leaching technique. The two types had initial salt weight fraction of 80 and 90%, and a salt particle size of 106-150 microm, while the third type had 90% initial weight fraction of salt in the size range 0-53 microm. The porosities of the resulting foams were 0.82, 0.89, and 0.85 for PLGA 85 : 15, and 0.73, 0.87, and 0.84 for PLGA 50 : 50 foams, respectively. The corresponding median pore diameters were 30, 50, and 17 microm for PLGA 85: 15, and 19, 17, and 17 microm for PLGA 50 : 50. The in vitro and in vivo degradation kinetics of PLGA 85: 15 foams were independent of pore morphology with insignificant variation in foam weight, thickness, pore distribution, compressive creep behavior, and morphology during degradation. The in vitro foam half-lives based on the weight average molecular weight were 11.1 +/- 1.8 (80%, 106-150 microm), 12.0 +/- 2.0 (90%, 106-150 microm), and 11.6 +/- 1.3 (90%, 0-53 microm) weeks, similar to the corresponding values of 9.4 +/- 2.2, 14.3 +/- 1.5, and 13.7 +/- 3.3 weeks for in vivo degradation. In contrast, all PLGA 50 : 50 foams exhibited significant change in fo…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Polymer composition is the most important factor to determine the hydrophilicity and rate of degradation of a delivery matrix which influence the rate of degradation.”
From Poly Lactic-co-Glycolic Acid (PLGA) as Biodegradable Controlled Drug Delivery Carrier (2011) · cites this paper as [77]
In the citing paper
“These results show that increase in glycolic acid percentage in the oligomers accelerates the weight loss of polymer.”
From Poly Lactic-co-Glycolic Acid (PLGA) as Biodegradable Controlled Drug Delivery Carrier (2011) · cites this paper as [77]
Citations
Cites
Applied Linear Statistical Models
Ziegel, E. R., Neter, J., Wasserman, W., & Kutner, M. (1992) · Technometrics · doi:10.2307/1269588 · Cited by 9,907
(2013) · doi:10.1016/c2009-0-02433-7 · Cited by 5,127
Mechanisms of polymer degradation and erosion
Göpferich, A. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85755-3 · Cited by 1,781
Applied Linear Statistical Models
Senter, H. F. (2008) · Journal of the American Statistical Association · doi:10.1198/016214508000000300 · Cited by 1,387
Biodegradable polymers for use in surgery—polyglycolic/poly(actic acid) homo- and copolymers: 1
Gilding, D. K., & Reed, A. M. (1979) · Polymer · doi:10.1016/0032-3861(79)90009-0 · Cited by 1,345
Preparation and characterization of poly(l-lactic acid) foams
Mikos, A. G., Thorsen, A. J., Czerwonka, L. A., Bao, Y., Langer, R., Winslow, D. N., & Vacanti, J. P. (1994) · Polymer · doi:10.1016/0032-3861(94)90953-9 · Cited by 1,187
Self-citationBone formation by three-dimensional stromal osteoblast culture in biodegradable polymer scaffolds
Ishaug, S. L., Crane, G. M., Miller, M. J., Yasko, A. W., Yaszemski, M. J., & Mikos, A. G. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199707)36:1<17::aid-jbm3>3.0.co;2-o · Cited by 833
Self-citationLi, S. M., Garreau, H., & Vert, M. (1990) · Journal of Materials Science: Materials in Medicine · doi:10.1007/bf00700871 · Cited by 733
Miller, R. A., Brady, J. M., & Cutright, D. E. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110507 · Cited by 722
Laminated three-dimensional biodegradable foams for use in tissue engineering
Mikos, A. G., Sarakinos, G., Leite, S. M., Vacant, J. P., & Langer, R. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90049-8 · Cited by 666
Self-citation
Cited by
Items 101–200 of 680
In vitro–in vivo characterization of gentamicin bone implants
Baro, M., Sánchez, E., Delgado, A., Perera, A., & Évora, C. (2002) · Journal of Controlled Release · doi:10.1016/s0168-3659(02)00179-7 · Cited by 120
Gene delivery from polymer scaffolds for tissue engineering
Jang, J., Houchin‐Ray, T., & Shea, L. D. (2004) · Expert Review of Medical Devices · doi:10.1586/17434440.1.1.127 · Cited by 127
Kauffman, K. J., Do, C., Sharma, S., Gallovic, M. D., Bachelder, E. M., & Ainslie, K. M. (2012) · ACS Applied Materials & Interfaces · doi:10.1021/am3008888 · Cited by 118
A comparative study on Poly(ε-caprolactone) film degradation at extreme pH values
Sailema-Palate, G. P., Vidaurre, A., Campillo-Fernández, A. J., & Castilla-Cortázar, I. (2016) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2016.06.005 · Cited by 115
Biodegradable Polymer Grafts for Surgical Repair of the Injured Spinal Cord
Friedman, J. A., Windebank, A. J., Moore, M. J., Spinner, R. J., Currier, B. L., & Yaszemski, M. J. (2002) · Neurosurgery · doi:10.1097/00006123-200209000-00024 · Cited by 120
Single-injection vaccines: Progress, challenges, and opportunities
McHugh, K. J., Guarecuco, R., Langer, R., & Jaklenec, A. (2015) · Journal of Controlled Release · doi:10.1016/j.jconrel.2015.07.029 · Cited by 112
Self-citationTruong-Le, V. L., Lovalenti, P. M., & Abdul‐Fattah, A. M. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.08.001 · Cited by 104
In vitro and in vivo degradation of poly(l-lactide-co-glycolide) films and scaffolds
Pamuła, E., & Menaszek, E. (2007) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-007-3292-2 · Cited by 115
Zhang, Q., Jiang, Y., Zhang, Y., Ye, Z., Tan, W., & Lang, M. (2013) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2012.10.008 · Cited by 102
Synthetic Biomaterials for Regenerative Medicine Applications
Samavedi, S., Poindexter, L. K., Dyke, M. E. V., & Goldstein, A. S. (2013) · Elsevier eBooks · doi:10.1016/b978-0-12-398523-1.00007-0 · Cited by 132
Hoornaert, A., d’Arros, C., Heymann, M., & Layrolle, P. (2016) · Biomedical Materials · doi:10.1088/1748-6041/11/4/045012 · Cited by 112
Hu, Y. Y., Hoerle, R., Ehrich, M. F., & Zhang, C. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.09.032 · Cited by 102
“For example, early study on PLGA degradation showed that the half-lives of PLGA structures were less than 4 weeks [24].”
“Wet‐state” mechanical properties of three‐dimensional polyester porous scaffolds
Wu, L., Zhang, J., Jing, D., & Ding, J. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30544 · Cited by 114
Mao, D., Li, Q., Li, D., Chen, Y., Chen, X., & Xu, X. (2018) · Materials & Design · doi:10.1016/j.matdes.2018.01.016 · Cited by 101
Yang, Y., Zhao, Y., Tang, G., Li, H., Yuan, X., & Fan, Y. (2008) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2008.07.007 · Cited by 112
Poly(α-hydroxy acid) based polymers: A review on material and degradation aspects
Ginjupalli, K., Shavi, G. V., Averineni, R. K., Bhat, M., Udupa, N., & Upadhya, N. P. (2017) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2017.08.024 · Cited by 105
Oh, S. H., Kang, S. G., & Lee, J. H. (2006) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-006-6816-2 · Cited by 100
Pinto, M., Silva, V., Barreiro, S., Silva, R. V. D. S., Remião, F., Borges, F., & Fernandes, C. (2022) · Ageing Research Reviews · doi:10.1016/j.arr.2022.101658 · Cited by 100
Delivery systems for small molecule drugs, proteins, and DNA: the neuroscience/biomaterial interface
Whittlesey, K. J., & Shea, L. D. (2004) · Experimental Neurology · doi:10.1016/j.expneurol.2004.06.020 · Cited by 111
Patil, P. S., Fountas-Davis, N., Huang, H., Michelle Evancho-Chapman, M., Fulton, J. A., Shriver, L. P., & Leipzig, N. D. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.03.022 · Cited by 98
“Thus, it is likely that the degradation observed in vitro was greater than what the hydrogel would experience in vivo when used as a wound dressing [56].”
BackgroundMarković, M., Hoorick, J. V., Hölzl, K., Tromayer, M., Gruber, P., Nürnberger, S., Dubruel, P., Vlierberghe, S. V., Liska, R., & Ovsianikov, A. (2015) · Journal of Nanotechnology in Engineering and Medicine · doi:10.1115/1.4031466 · Cited by 109
“The use of the low pressure vacuum for prewetting in the experiment ensures that the scaffolds are free of air bubbles or residues of chemicals like ethanol frequently used in these procedures [45,46].”
MethodCiprofloxacin implants for bone infection. In vitro–in vivo characterization
Castro, C., Sánchez, E., Delgado, A., Soriano, I., Núñez, P., Baro, M., Perera, A., & Évora, C. (2003) · Journal of Controlled Release · doi:10.1016/j.jconrel.2003.09.004 · Cited by 95
Engineering nanomedicines using stimuli-responsive biomaterials
Wang, Y., Byrne, J. D., Napier, M. E., & DeSimone, J. M. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.01.003 · Cited by 104
“PLGA degrades by hydrolysis of its ester linkages in the presence of water, which can shift the local pH when PLGA is given in large quantities [69].”
BackgroundElectrospray for generation of drug delivery and vaccine particles applied in vitro and in vivo
Stiepel, R. T., Gallovic, M. D., Batty, C. J., Bachelder, E. M., & Ainslie, K. M. (2019) · Materials Science and Engineering C · doi:10.1016/j.msec.2019.110070 · Cited by 96
Huang, W., Carlsen, B. T., Wulur, I. H., Rudkin, G. H., Ishida, K., Wu, B. M., Yamaguchi, D. T., & Miller, T. A. (2004) · Experimental Cell Research · doi:10.1016/j.yexcr.2004.04.051 · Cited by 94
Degradation of synthetic polymeric scaffolds for bone and cartilage tissue repairs
Eglin, D., Mortisen, D. J., & Alini, M. (2009) · Soft Matter · doi:10.1039/b803718n · Cited by 108
Constructing conductive conduit with conductive fibrous infilling for peripheral nerve regeneration
Wei, J., Ao, Q., Wang, L., Huang, Z., Cai, Q., Chen, G., Yang, X., & Zhong, W. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2018.04.044 · Cited by 95
Schantz, J., Hutmacher, D. W., Chim, H., Ng, K. W., Lim, T. C., & Teoh, S. H. (2002) · Cell Transplantation · doi:10.3727/096020198389852 · Cited by 93
The bone formation in vitro and mandibular defect repair using PLGA porous scaffolds
Ren, T., Ren, J., Jia, X., & Pan, K. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30324 · Cited by 92
Liu, H., Li, X., Niu, X., Zhou, G., Li, P., & Fan, Y. (2011) · Biomacromolecules · doi:10.1021/bm200479f · Cited by 90
Li, B., & Yang, M. (2006) · Polymers for Advanced Technologies · doi:10.1002/pat.731 · Cited by 88
Application of biomaterials to advance induced pluripotent stem cell research and therapy
Tong, Z., Solanki, A., Hamilos, A. E., Levy, O., Wen, K., Yin, X., & Karp, J. M. (2015) · The EMBO Journal · doi:10.15252/embj.201490756 · Cited by 99
“Its degradation rate can be tailored by balancing the ratio of lactic acid and glycolic acid and altering the molecular weight, thereby enabling controlled release of encapsulated genetic materials (Lu et al, 2000; Danhier et al, 2012).”
BackgroundKim, J., Yaszemski, M. J., & Lu, L. (2009) · Tissue Engineering Part C Methods · doi:10.1089/ten.tec.2008.0642 · Cited by 90
“32 Therefore, micro-CT technique may provide more accurate assessment of scaffold’s porosity because the FIG.”
Self-citationHong, Z., Zhang, P., Liu, A., Chen, L., Chen, X., & Jing, X. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31038 · Cited by 95
Biodegradation of a silkworm silk/PLA composite
Cheung, H., Lau, K.-T., Pow, Y.-F., Zhao, Y., & Hui, D. (2009) · Composites Part B Engineering · doi:10.1016/j.compositesb.2009.09.004 · Cited by 95
“Silk fiber has long been used as surgical sutures in medical history; their substantial biomechanical properties are the main advantage for utilizing them in biomedical applications [1-7].”
BackgroundHuang, Y., Huang, C., Huang, Y., & Chen, K. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31036 · Cited by 89
Deschamps, A. A., van Apeldoorn, A. A., Hayen, H., de Bruijn, J. D., Kärst, U., Grijpma, D. W., & Feijén, J. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00495-2 · Cited by 97
Biodegradability and Biocompatibility Study of Poly(Chitosan-g-lactic Acid) Scaffolds
Zhang, Z., & Cui, H. (2012) · Molecules · doi:10.3390/molecules17033243 · Cited by 92
Electrospun acid-neutralizing fibers for the amelioration of inflammatory response
Shen, Y., Tu, T., Yi, B., Wang, X., Tang, H., Liu, W., & Zhang, Y. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.08.014 · Cited by 87
Roces, C. B., Christensen, D., & Perrie, Y. (2020) · Drug Delivery and Translational Research · doi:10.1007/s13346-019-00699-y · Cited by 92
Regulation of Drug Release by Tuning Surface Textures of Biodegradable Polymer Microparticles
Hussain, M., Xie, J., Hou, Z., Shezad, K., Xu, J., Wang, K., Gao, Y., Shen, L., & Zhu, J. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b02002 · Cited by 95
Hydroxyapatite Nanoparticle Coating on Polymer for Constructing Effective Biointeractive Interfaces
Galindo, T. G. P., Chai, Y., & Tagaya, M. (2019) · Journal of Nanomaterials · doi:10.1155/2019/6495239 · Cited by 107
Recombinant human collagen/chitosan-based soft hydrogels as biomaterials for soft tissue engineering
Yang, Y., Ritchie, A. C., & Everitt, N. M. (2021) · Materials Science and Engineering C · doi:10.1016/j.msec.2020.111846 · Cited by 87
Lu, L., Yaszemski, M. J., & Mikos, A. G. (2001) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200100002-00002 · Cited by 101
Self-citationIn vitro degradation of porous degradable and bioactive PHBV/wollastonite composite scaffolds
Li, H., & Chang, J. (2004) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2004.09.001 · Cited by 90
Polymer Design and Development
Arakawa, C. K., & DeForest, C. A. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-802734-9.00019-6 · Cited by 94
“PLGA is especially appealing as one can alter the degradation rate of the material by altering the ratio of glycolic acid to lactic acid during polymer synthesis, where higher glycolic acid contents yield faster degradation.(84)”
BackgroundDevelopment of biodegradable scaffolds for tissue engineering: A perspective on emerging technology
Liu, C., & Czernuszka, J. T. (2007) · Materials Science and Technology · doi:10.1179/174328407x177027 · Cited by 89
Yuan, L., Li, X., Ge, L., Jia, X., Lei, J., Mu, C., & Li, D. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b17555 · Cited by 85
Hofer, S. O. P., Knight, K. M., Cooper-White, J. J., O’Connor, A. J., Perera, J. M., Romeo-Meeuw, R., Penington, A., Knight, K. R., Morrison, W. A., & Messina, A. (2003) · Plastic & Reconstructive Surgery · doi:10.1097/01.prs.0000046034.02158.eb · Cited by 90
Pini, R., Storti, G., Mazzotti, M., Tai, H., Shakesheff, K. M., & Howdle, S. M. (2008) · Journal of Polymer Science Part B Polymer Physics · doi:10.1002/polb.21382 · Cited by 85
SIKVAV-modified highly superporous PHEMA scaffolds with oriented pores for spinal cord injury repair
Kubinová, Š., Horák, D., Hejčl, A., Plichta, Z., Kotek, J., Proks, V., Forostyak, S., & Syková, E. (2013) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.1694 · Cited by 84
“Pores can be introduced into scaffolds by a variety of processes involving salt-leaching (Lu et al., 2000; Murphy et al., 2002), phase inversion (Holy et al., 1999, 2000), high-pressure gasification (Holy et al., 1999; Riddle and Mooney, 2004), gas-forming foam, thermal-induced phase separation,…”
BackgroundZhu, X. H., Lee, L. Y., Jackson, J. S. H., Tong, Y. W., & Wang, C. (2008) · Biotechnology and Bioengineering · doi:10.1002/bit.21824 · Cited by 87
“It has been shown recently that aggregated cells retain differentiated properties much better than cells in ordinary monolayers (Lu et al., 2000; Mooney et al., 1996).”
Xiang, P., Wang, S.-S., He, M., Han, Y.-H., Zhou, Z.-H., Chen, D.-L., Li, M., & Ma, L. Q. (2017) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2017.12.020 · Cited by 83
Ho, S. T. B., Hutmacher, D. W., Ekaputra, A. K., Hitendra, D., & Hui, J. H. P. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2009.0471 · Cited by 83
“11 Niederauer et al. resorted to fiber reinforcement so as to achieve a stiffness of 32 MPa for the PLGA matrix.”
Optimization of rapamycin-loaded acetalated dextran microparticles for immunosuppression
Kauffman, K. J., Kanthamneni, N., Meenach, S. A., Pierson, B. C., Bachelder, E. M., & Ainslie, K. M. (2011) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2011.10.034 · Cited by 76
Methods for in vitro characterization of multichannel nerve tubes
de Ruiter, G. C., Onyeneho, I. A., Liang, E. T., Moore, M. J., Knight, A. M., Malessy, M. J. A., Spinner, R. J., Lu, L., Currier, B. L., Yaszemski, M. J., et al. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31298 · Cited by 83
Self-citationMeenach, S. A., Kim, Y. J., Kauffman, K. J., Kanthamneni, N., Bachelder, E. M., & Ainslie, K. M. (2011) · Molecular Pharmaceutics · doi:10.1021/mp2003785 · Cited by 76
Phototherapy and optical waveguides for the treatment of infection
Wang, D., Kuzma, M. L., Tan, X., He, T., Dong, C., Liu, Z., & Yang, J. Y. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.114036 · Cited by 77
Bryan, D. J., Tang, J. B., Doherty, S. A., Hile, D. D., Trantolo, D. J., Wise, D. L., & Summerhayes, I. C. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/2/004 · Cited by 74
“In this report (Lu et al 2000) the in vivo half-life ranged between 9 and 14 weeks, consistent with our observations and those reported by the manufacturer.”
MethodResultThe intracellular uptake ability of chitosan-coated Poly (D,L-lactideco-glycolide) nanoparticles
Kim, B., Kim, C.-S., & Lee, K. (2008) · Archives of Pharmacal Research · doi:10.1007/s12272-001-1267-5 · Cited by 82
“…degradation rate of a PLGA polymer can be controlled by fine-tuning the molar ratios of the lactic and glycolic acids in the polymer chain, the degree of crystallinity, and the molecular weight and stereochemistry of the polyester (Holy et al., 1999; Lu et al., 1999; Lu et al., 2000; Park, 1995).”
BackgroundBiomatrices for bladder reconstruction
Lin, H., Madihally, S. V., Palmer, B. W., Frimberger, D. C., Fung, K.-M. A., & Kropp, B. P. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.11.020 · Cited by 76
Polímeros bioreabsorvíveis na engenharia de tecidos
Barbanti, S. H., Zavaglia, C. A. C., & Duek, E. A. D. R. (2005) · Polímeros · doi:10.1590/s0104-14282005000100006 · Cited by 192
Modeling the dynamic composition of engineered cartilage
Wilson, C. G., Bonassar, L. J., & Kohles, S. S. (2002) · Archives of Biochemistry and Biophysics · doi:10.1016/s0003-9861(02)00562-3 · Cited by 73
Santo, V. E., Duarte, A. R. C., Gomes, M. E., Mano, J. F., & Reis, R. L. (2010) · The Journal of Supercritical Fluids · doi:10.1016/j.supflu.2010.05.021 · Cited by 79
“Common scaffold fabrication techniques include solvent casting/salt leaching [17], moulding/salt leaching [18], and gas foaming/salt leaching [19].”
MethodIn vitro Study on Biodegradable AZ31 Magnesium Alloy Fibers Reinforced PLGA Composite
Wu, Y., Li, N., Cheng, Y., Zheng, Y., & Han, Y. N. (2013) · Journal of Material Science and Technology · doi:10.1016/j.jmst.2013.03.004 · Cited by 69
Liu, X., Wei, D., Zhong, J. Q., Ma, M., Zhou, J., Peng, X., Ye, Y., Sun, G., & He, D. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b04868 · Cited by 70
Multilayer porous UHMWPE scaffolds for bone defects replacement
Maksimkin, A. V., Senatov, F. S., Anisimova, N. Y., Kiselevskiy, M. V., Zalepugin, D. Y., Chernyshova, I. V., Tilkunova, N. A., & Kaloshkin, S. D. (2016) · Materials Science and Engineering C · doi:10.1016/j.msec.2016.12.104 · Cited by 70
Immunogenicity of pulsatile-release PLGA microspheres for single-injection vaccination
Guarecuco, R., Lu, J., McHugh, K. J., Norman, J. J., Thapa, L. S., Lydon, E., Langer, R., & Jaklenec, A. (2017) · Vaccine · doi:10.1016/j.vaccine.2017.05.094 · Cited by 69
“…degree of acceleration in vivo is similar to other studies that have estimated microsphere degradation to be 1.7–2.6 times more rapid in vivo than in vitro [39] because of prolonged autocatalytic action of acid [17] as well as plasticization of PLGA by lipids and other biological molecules [40].”
BackgroundInfluentialSelf-citationCostantini, M., Colosi, C., Jaroszewicz, J., Tosato, A., Święszkowski, W., Dentini, M., Garstecki, P., & Barbetta, A. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b08221 · Cited by 68
Davison, N. L., Groot, F. B., & Grijpma, D. W. (2014) · Elsevier eBooks · doi:10.1016/b978-0-12-420145-3.00006-7 · Cited by 86
“Implants based on PEOT/PBT copolymers have been evaluated extensively in various implantation sites and extensive fragmentation of the implants was visible within 4weeks, thereby significantly enlarging the implant surface (Lu et al., 2000).”
BackgroundTailoring the Interface of Biomaterials to Design Effective Scaffolds
Parisi, L., Toffoli, A. S., Ghiacci, G., & Macaluso, G. M. (2018) · Journal of Functional Biomaterials · doi:10.3390/jfb9030050 · Cited by 71
“After polymerization, porogens are thus leached away from the scaffold leaving a structure with the 94–95% of percentage porosity [74].”
BackgroundKim, H. Y., Kim, H., Lee, S. J., Song, J. E., Kwon, S. Y., Chung, J. W., Lee, D., & Khang, G. (2014) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.1856 · Cited by 67
“…with high porosity provide a high surface area to facilitate cell adhesion and cell–polymer interactions and offer sufficient space for cell proliferation and tissue growth during in vitro culture (Murphy et al., 2000; Freed et al., 1994; Liao et al., 2005; Lu et al., 2000; Kim et al., 2007).”
BackgroundMethodWang, M. O., Piard, C., Melchiorri, A. J., Dreher, M. L., & Fisher, J. P. (2015) · Tissue Engineering Part A · doi:10.1089/ten.tea.2014.0495 · Cited by 68
“40,41 For PPF in vivo , the acidic byproduct is fumaric acid and it would be metabolized as a part of the Kreb’s cycle; whereas in vitro we are unable mimic this process.”
Lange, J., de Souza, F. G., Nele, M., Tavares, F. W., Segtovich, I. S. V., da Silva, G. C. Q., & Pinto, J. C. (2015) · Macromolecular Theory and Simulations · doi:10.1002/mats.201500049 · Cited by 68
In vitro and in vivo changes to PLGA/sirolimus coating on drug eluting stents
Xi, T., Gao, R., Xu, B., Chen, L., Luo, T., Liu, J., Wei, Y., & Zhong, S. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.02.003 · Cited by 73
“According to the published research, the accelerated degradation in the in vivo conditions normally attributed to the free radicals, enzymes or acidic products caused by the foreign body response [31], the lipids [17] or other substances in the in vivo environment acting as the plasticizers [29].”
BackgroundLi, H., Du, R., & Chang, J. (2005) · Journal of Biomaterials Applications · doi:10.1177/0885328205049472 · Cited by 73
Kanthamneni, N., Sharma, S., Meenach, S. A., Billet, B., Zhao, J., Bachelder, E. M., & Ainslie, K. M. (2012) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2012.04.043 · Cited by 74
Ouhsti, M., Haddadi, B. E., & Belhouideg, S. (2018) · Mechanics and Mechanical Engineering · doi:10.2478/mme-2018-0070 · Cited by 54
Development of Intrinsically Photoluminescent and Photostable Polylactones
Xie, Z., Zhang, Y. L., Liu, L., Weng, H., Mason, R. P., Tang, L., Nguyen, K. T., Hsieh, J., & Yang, J. Y. (2014) · Advanced Materials · doi:10.1002/adma.201306070 · Cited by 65
Accelerating protein release from microparticles for regenerative medicine applications
White, L. J., Kirby, G. T. S., Cox, H. C., Qodratnama, R., Qutachi, O., Rose, F. R. A. J., & Shakesheff, K. M. (2013) · Materials Science and Engineering C · doi:10.1016/j.msec.2013.02.020 · Cited by 74
Handa, H., Brisbois, E. J., Major, T. C., Refahiyat, L., Amoako, K. A., Annich, G. M., Bartlett, R. H., & Meyerhoff, M. E. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb20277a · Cited by 64
In vitro evaluation of porous poly( L ‐lactic acid) scaffold reinforced by chitin fibers
Li, X., Liu, X., Wei, D., Feng, Q., Cui, F., Uo, M., Akasaka, T., & Watari, F. (2009) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31311 · Cited by 64
Yang, J., Tian, W., Li, Q., Li, Y., & 曹阿民 (2004) · Biomacromolecules · doi:10.1021/bm049705+ · Cited by 64
Optimisation of polymer scaffolds for retinal pigment epithelium (RPE) cell transplantation
Thomson, H. A., Treharne, A. J., Walker, P., Grossel, M. C., & Lotery, A. J. (2009) · British Journal of Ophthalmology · doi:10.1136/bjo.2009.166728 · Cited by 64
“However, there have only been limited studies to identify the optimal polymer composition for such grafts.”
BackgroundZhang, J. C., Liu, H., Ding, J., Wu, J., Zhuang, X., Chen, X., Wang, J., Yin, J., & Li, Z. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.6b00202 · Cited by 64
Hydrogel and Nanomedicine‐Based Multimodal Therapeutic Strategies for Spinal Cord Injury
Yin, P., Liang, W., Han, B. R., Yang, Y., Sun, D., Qu, X., Hai, Y., & Luo, D. (2023) · Small Methods · doi:10.1002/smtd.202301173 · Cited by 66
Effects of HAp and TCP in constructing tissue engineering scaffolds for bone repair
Xu, S., Liu, J. F., Zhang, L., Yang, F., Tang, P., & Wu, D. (2017) · Journal of Materials Chemistry B · doi:10.1039/c7tb00790f · Cited by 63
Gomes, M. E., & Reis, R. L. (2004) · International Materials Reviews · doi:10.1179/095066004225021927 · Cited by 70
Targeting Glucose Metabolism in Cancer Cells as an Approach to Overcoming Drug Resistance
Cunha, A., Silva, P. M. A., Sarmento, B. F. C. C., & Queirós, O. (2023) · Pharmaceutics · doi:10.3390/pharmaceutics15112610 · Cited by 64
Liu, T., Wang, Y., & Kuang, T. (2023) · Macromolecular Materials and Engineering · doi:10.1002/mame.202300246 · Cited by 62
In vitro degradation of porous PLLA/pearl powder composite scaffolds
Liu, Y. S., Huang, Q., Kienzle, A., Müller, W. E. G., & Feng, Q. (2014) · Materials Science and Engineering C · doi:10.1016/j.msec.2014.02.007 · Cited by 62
Kim, S. H., Kim, S. H., & Jung, Y. (2015) · Journal of Controlled Release · doi:10.1016/j.jconrel.2015.03.026 · Cited by 64
Inverse opal scaffolds for applications in regenerative medicine
Zhang, Y. S., Choi, S., & Xia, Y. (2013) · Soft Matter · doi:10.1039/c3sm52063c · Cited by 63
El Khatib, M., Mauro, A., Di Mattia, M., Wyrwa, R., Schweder, M., Ancora, M., Lazzaro, F., Berardinelli, P., Valbonetti, L., Di Giacinto, O., et al. (2020) · Cells · doi:10.3390/cells9051207 · Cited by 59
“It is known that PLGA, in particular, provides sufficient control of degradation [77,78] conjugated to adequate mechanical strength that fosters its application in tissue remodeling and regeneration [79,80], and thus widely used in tendon tissue engineering.”
BackgroundMaterial-related effects of BMP-2 delivery systems on bone regeneration
Hernández, A., Sánchez, E., Soriano, I., Reyes, R., Delgado, A., & Évora, C. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.10.008 · Cited by 63
“[28].”
Dånmark, S., Finne‐Wistrand, A., Wendel, M., Arvidson, K., Albertsson, A., & Mustafa, K. (2010) · Journal of Bioactive and Compatible Polymers · doi:10.1177/0883911509358812 · Cited by 62
Keshaw, H., Georgiou, G., Blaker, J. J., Forbes, A., Knowles, J. C., & Day, R. M. (2008) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0203 · Cited by 62
Rahman, M. S., & Tsuchiya, T. (2001) · Tissue Engineering · doi:10.1089/107632701753337726 · Cited by 66
“15 16–21 To perform adequately during many years of service, biodegradable implants in particular should serve their intended functions by releasing products of degradation, without producing locally and systemically toxic effects, and without interfering with tissue healing.”
Alam, A. M. M. N., Kim, C.-J., Kim, S.-H., Kumari, S., Lee, E.-Y., Hwang, Y.-H., & Joo, S.-T. (2024) · Food Research International · doi:10.1016/j.foodres.2024.114549 · Cited by 71
“(Lanza et al., 2020; Leong et al., 2003; Liao et al., 2002; Lu et al., 2000; Taqvi & Roy, 2006; Yang et al., 2002) Collagen Chicken The utilization of collagen microcarriers was investigated in order to enhance the process of myogenesis and replicate the characteristics of muscle fibers resembling…”
MethodPeine, K. J., Bachelder, E. M., VanGundy, Z., Papenfuss, T. L., Brackman, D. J., Gallovic, M. D., Schully, K. L., Pesce, J. T., Keane‐Myers, A., & Ainslie, K. M. (2013) · Molecular Pharmaceutics · doi:10.1021/mp300643d · Cited by 62
Metadata
- Authors
- Lu, L., Peter, S. J., D. Lyman, M., Lai, H.-L., Leite, S. M., Tamada, J. A., Uyama, S., Vacanti, J. P., Langer, R., & Mikos, A. G.
- Affiliations
- Rice University (US)
- Massachusetts Institute of Technology (US)
- Boston Children's Hospital (US)
- Corresponding author
- Mikos, Antonios G
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2000-09
- Volume
- 21
- Issue
- 18
- Pages
- 1837-1845
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2049435279
- Semantic Scholar
- 0b11d421cc2573858f7b2fb6643958e95e4929cf
- Cited by
- 668
- References
- 31
- Citations by year
- 2026: 13 · 2025: 14 · 2024: 18 · 2023: 23 · 2022: 27 · 2021: 22 · 2020: 29 · 2019: 28 · 2018: 45 · 2017: 41 · 2016: 29 · 2015: 32 · 2014: 29 · 2013: 32 · 2012: 43
- FWCI
- 8.49
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Aeronautics and Space Administration
- National Institutes of Health (5r29ar042639-03, 5r01ar044381-04, 5r01de013031-05)
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (R29-AR42639, R01-AR44381)
- National Institute of Dental and Craniofacial Research (R01 DE13031)
- Topics
- Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- biodegradation, porous polymers, salt leaching, pore size, degradation kinetics, half-life, water absorption, compressive creep, biodegradable scaffolds, tissue engineering
- MeSH terms
- Polylactic Acid-Polyglycolic Acid Copolymer, Animals, Biocompatible Materials, Biodegradation, Environmental, Half-Life, Hot Temperature, Hydrogen-Ion Concentration, Kinetics, Mercury, Mesentery, Polyglycolic Acid, Polymers, Thermodynamics, Lactic Acid, Prostheses and Implants, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.