Multi-electrode stimulation and recording in the isolated retina
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DISCHARGE PATTERNS AND FUNCTIONAL ORGANIZATION OF MAMMALIAN RETINA
Kuffler, S. W. (1953) · Journal of Neurophysiology · doi:10.1152/jn.1953.16.1.37 · Cited by 2,609
Which elements are excited in electrical stimulation of mammalian central nervous system: A review
Ranck, J. B. (1975) · Brain Research · doi:10.1016/0006-8993(75)90364-9 · Cited by 2,024
Analysis of Models for External Stimulation of Axons
Rattay, F. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325670 · Cited by 681
Pattern electrical stimulation of the human retina
Humayun, M. S., de Juan Jr., E., Weiland, J. D., Dagnelie, G., Katona, S., Greenberg, R., & Suzuki, S. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00052-8 · Cited by 592
Multi-neuronal signals from the retina: acquisition and analysis
Meister, M., Pine, J., & Baylor, D. A. (1994) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(94)90030-2 · Cited by 411
A neural interface for a cortical vision prosthesis
Normann, R. A., Maynard, E. M., Rousche, P. J., & Warren, D. J. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00040-1 · Cited by 409
Medical Physiology and Biophysics.
(1960) · Annals of Internal Medicine · doi:10.7326/0003-4819-53-4-856 · Cited by 361
Plonsey, R. (1999) · Wiley Encyclopedia of Electrical and Electronics Engineering · doi:10.1002/047134608x.w1403 · Cited by 335
In Vitro Retina as an Experimental Model of the Central Nervous System
Ames, A., & Nesbett, F. B. (1981) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1981.tb04473.x · Cited by 326
Mosaic Arrangement of Ganglion Cell Receptive Fields in Rabbit Retina
Devries, S. H., & Baylor, D. A. (1997) · Journal of Neurophysiology · doi:10.1152/jn.1997.78.4.2048 · Cited by 313
Cited by
Multi-electrode array technologies for neuroscience and cardiology
Spira, M. E., & Hai, A. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2012.265 · Cited by 991
“Increasing the surface area by using nanostructures such as spongy platinum black or Ti 3 N 4 (refs 48–50), gold nanoflakes and nanopillars 51,52 , or carbon nanotubes 53,54 is used to compensate for the dimensions of the electrode surface ‘visible’ to the cell.”
MethodWill Retinal Implants Restore Vision?
Zrenner, E. (2002) · Science · doi:10.1126/science.1067996 · Cited by 724
Retinal Prosthesis for the Blind
Margalit, E., Maia, M., Weiland, J. D., Greenberg, R. J., Fujii, G. Y., Torres, G., Piyathaisere, D. V., O'Hearn, T. M., Liu, W., Lazzi, G., et al. (2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00311-9 · Cited by 427
Weiland, J. D., Liu, W., & Humayun, M. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100435 · Cited by 371
Direct and Indirect Activation of Cortical Neurons by Electrical Microstimulation
Tehovnik, E. J., Tolias, A. S., Sultan, F., Slocum, W. M., & Logothetis, N. K. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00126.2006 · Cited by 357
Electrical Stimulation of Mammalian Retinal Ganglion Cells With Multielectrode Arrays
Sekirnjak, C., Hottowy, P., Sher, A., Dabrowski, W., Litke, A. M., & Chichilnisky, E. J. (2006) · Journal of Neurophysiology · doi:10.1152/jn.01168.2005 · Cited by 337
Effective parameters for stimulation of dissociated cultures using multi-electrode arrays
Wagenaar, D. A., Pine, J., & Potter, S. M. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.03.005 · Cited by 304
Pattern recognition with the optic nerve visual prosthesis
Veraart, C., Wanet‐Defalque, M., Gérard, B., Vanlierde, A., & Delbeke, J. (2003) · Artificial Organs · doi:10.1046/j.1525-1594.2003.07305.x · Cited by 259
Real-time multi-channel stimulus artifact suppression by local curve fitting
Wagenaar, D. A., & Potter, S. M. (2002) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00149-8 · Cited by 227
“In addition, electrical stimulation through such arrays has been reported in a wide variety of preparations, such as murine spinal cord (Gross et al. 1993), rat cortex (Jimbo et al. 1999), cat sciatic nerve (Branner and Normann 2000) and rabbit retina ( Grumet et al. 2000 ).”
BackgroundMethodInfluentialHigh-Resolution Electrical Stimulation of Primate Retina for Epiretinal Implant Design
Sekirnjak, C., Hottowy, P., Sher, A., Dabrowski, W., Litke, A. M., & Chichilnisky, E. J. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.5138-07.2008 · Cited by 194
“…in diameter (Humayun, 2003; Mahadevappa et al., 2005), but prototype arrays with much smaller electrodes placed in close proximity to the ganglion cell layer have been developed (Rizzo et al., 1996; Grumet et al., 2000; Stett et al., 2000; Litke et al., 2003; Wilms et al., 2003; Shah et al., 2007).”
BackgroundNeuroMEMS: Neural Probe Microtechnologies
HajjHassan, M., Chodavarapu, V., & Musallam, S. (2008) · Sensors · doi:10.3390/s8106704 · Cited by 190
Jensen, R. J., Rizzo, J. F., Ziv, O. R., Grumet, A., & Wyatt, J. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-1041 · Cited by 145
Self-citationMaynard, E. M. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.145 · Cited by 126
“Further experiments have shown that arrays of disk electrodes can be used to evoke neural activity in an isolated retina (41) and that passive devices seem to be exceedingly well tolerated by the retina (42).”
BackgroundTimko, B. P., Cohen-Karni, T., Qing, Q., Tian, B., & Lieber, C. M. (2010) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2009.2031807 · Cited by 114
“NW devices that form intimate extracellular or IC connections with excitable cells and tissue might furthermore be used for functional prosthetics, which could complement current technology used to address problems such as spinal cord injuries [90] and blindness [ 91 ], [92].”
BackgroundResolution of the epiretinal prosthesis is not limited by electrode size
Behrend, M. R., Ahuja, A. K., Humayun, M. S., Chow, R. H., & Weiland, J. D. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2140132 · Cited by 102
“percepts using microelectrode arrays (MEAs) with very small electrodes [10]–[12].”
An integrated system for simultaneous, multichannel neuronal stimulation and recording.
Blum, R. A., Ross, J. D., Brown, E. A., & DeWeerth, S. P. (2007) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2007.906071 · Cited by 74
Improved focalization of electrical microstimulation using microelectrode arrays: a modeling study
Joucla, S., & Yvert, B. (2009) · PLoS ONE · doi:10.1371/journal.pone.0004828 · Cited by 68
“Conventional bipolar configurations with two nearby electrodes actually focalize the stimulation, but create anisotropic potential fields [13,24].”
BackgroundHigh-frequency electrical stimulation of cardiac cells and application to artifact reduction.
Dura, B., Chen, M. Q., Inan, O. T., Kovacs, G. T. A., & Giovangrandi, L. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2188136 · Cited by 15
“artifacts (artifacts appear as common-mode signal) [34], [37].”
Metadata
- Authors
- Grumet, A. E., Wyatt, J. L., & Rizzo, J. F.
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2000-08
- Volume
- 101
- Issue
- 1
- Pages
- 31-42
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2034875812
- Cited by
- 167
- References
- 28
- FWCI
- 1.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.