Implications of SENSE MR in routine clinical practice
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303 · cited 2×
“The first method poses significant overhead by requiring full sampling of central k -space to provide the coil sensitivity maps, compromising the maximum attainable effective reduction factor [19] (Fig.”
BackgroundMethodImage Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance
LAUTERBUR, P. C. (1973) · Nature · doi:10.1038/242190a0 · Cited by 3,611
Roemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322 · cited 3×
“This ‘ideal’ phased-array reconstruction method [3] is known as constant level appearance (CLEAR).”
BackgroundMethodInfluentialSimultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
RARE imaging: A fast imaging method for clinical MR
Hennig, J., Nauerth, A., & Friedburg, H. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030602 · Cited by 2,081 · cited 1×
“Other substantial increases in imaging speed providing new diagnostic opportunities have been achieved by implementing rapid imaging techniques, such as EPI [4], FLASH [5] or FFE [6,7] and RARE [8] or TSE, and their variants and hybrids.”
MethodTracking neuronal fiber pathways in the living human brain
Conturo, T. E., Lori, N. F., Cull, T. S., Akbudak, E., Snyder, A. Z., Shimony, J. S., McKinstry, R. C., Burton, H., & Raichle, M. E. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.18.10422 · Cited by 1,774 · cited 2×
“To obtain a sufficiently high SNR, averaging over ten times has been employed [53,54].”
MethodAdvances in sensitivity encoding with arbitrary k‐space trajectories
Pruessmann, K. P., Weiger, M., Börnert, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1241 · Cited by 1,211 · cited 1×
“Combination of these techniques with SENSE has been shown to be feasible [66], but requiring even more processing power.”
MethodKatscher, U., Börnert, P., Leussler, C., & van den Brink, J. S. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10353 · Cited by 719
Self-citationDejerine, J. (1895) · Biblioteca Digital (Real Academia Nacional de Medicina) · Cited by 565
Analysis of connectivity in the cat cerebral cortex
Scannell, J., Blakemore, C., & Young, M. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-02-01463.1995 · Cited by 553
Turner, B. H., Mishkin, M., & Knapp, M. (1980) · Journal of Comparative Neurology · doi:10.1002/cne.901910402 · Cited by 534
Dynamic gadolinium‐enhanced three‐dimensional abdominal MR arteriography
Prince, M. R., Yucel, E. K., Kaufman, J. A., Harrison, D. C., & Geller, S. C. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030614 · Cited by 499 · cited 2×
“Since the introduction of contrast-enhanced magnetic resonance angiogram (CE-MRA) nearly a decade ago [23], this technique is now the most commonly used technique for obtaining MR angiograms of the chest or abdomen in the adult population.”
MethodDiffusion Tensor Imaging and Axonal Tracking in the Human Brainstem
Stieltjes, B., Kaufmann, W. E., van Zijl, P. C. M., Fredericksen, K., Pearlson, G. D., Solaiyappan, M., & Mori, S. (2001) · NeuroImage · doi:10.1006/nimg.2001.0861 · Cited by 492 · cited 2×
“To reduce image distortion, multishot-EPI with cardiac gating is used instead of single-shot EPI [53].”
MethodFiber Crossing in Human Brain Depicted with Diffusion Tensor MR Imaging
Wiegell, M. R., Larsson, H. B. W., & Wedeen, V. J. (2000) · Radiology · doi:10.1148/radiology.217.3.r00nv43897 · Cited by 380 · cited 1×
“Diffusion-tensor imaging (DTI) is a technique that allows us to visualize the anisotropy (directionality) of water movement caused by the presence of axons, axonal sheaths, glia cells and vasculature [50].”
MethodDiffusion magnetic resonance imaging: Its principle and applications
Mori, S., & Barker, P. B. (1999) · The Anatomical Record · doi:10.1002/(sici)1097-0185(19990615)257:3<102::aid-ar7>3.0.co;2-6 · Cited by 317
Bammer, R., Keeling, S. L., Augustin, M., Pruessmann, K. P., Wolf, R., Stollberger, R., Hartung, H., & Fazekas, F. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1226 · Cited by 311
Diffusion tensor imaging using single‐shot SENSE‐EPI
Bammer, R., Auer, M., Keeling, S. L., Augustin, M., Stables, L. A., Prokesch, R. W., Stollberger, R., Moseley, M. E., & Fazekas, F. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10184 · Cited by 279
A generalized approach to parallel magnetic resonance imaging
Sodickson, D. K., & McKenzie, C. A. (2001) · Medical Physics · doi:10.1118/1.1386778 · Cited by 245 · cited 1×
“The mathematical formalism underlying this method has been described in detail elsewhere [9,16].”
MethodContrast-enhanced 3D MRA using SENSE
Weiger, M., Pruessmann, K. P., Kassner, A., Roditi, G., Lawton, T., Reid, A., & Boesiger, P. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200011)12:5<671::aid-jmri3>3.0.co;2-f · Cited by 224 · cited 1×
“Along the same line, SENSE decreases the number of phase encodings and thereby acquisition time without compromising spatial resolution or volume coverage [9,35].”
BackgroundSpecific coil design for SENSE: A six-element cardiac array
Weiger, M., Pruessmann, K. P., Leussler, C. G., R�schmann, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200103)45:3<495::aid-mrm1065>3.0.co;2-v · Cited by 203 · cited 1×
“and engineering [61,62].”
Design of a SENSE‐optimized high‐sensitivity MRI receive coil for brain imaging
de Zwart, J. A., Ledden, P. J., Kellman, P., van Gelderen, P., & Duyn, J. H. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10169 · Cited by 192 · cited 1×
“and engineering [61,62].”
Fast imaging using subencoding data sets from multiple detectors
Ra, J. B., & Rim, C. Y. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300123 · Cited by 163
Kelekis, N. L., Semelka, R. C., Worawattanakul, S., de Lange, E. E., Ascher, S. M., Ahn, I. O., Reinhold, C., Remer, E. M., Brown, J. J., Bis, K. G., et al. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.170.4.9530051 · Cited by 161
Experimental strategies to promote axonal regeneration after traumatic central nervous system injury
Stichel, C. C., & Müller, H. W. (1998) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00033-1 · Cited by 157
Imaging time reduction through multiple receiver coil data acquisition and image reconstruction
Carlson, J. W., & Minemura, T. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290516 · Cited by 120
Detection and elimination of motion artifacts by regeneration of k ‐space
Bydder, M., Larkman, D. J., & Hajnal, J. V. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10093 · Cited by 80 · cited 1×
“Motion artifact correction Apart from SENSE’s capability to reduce the sensitivity to involuntary patient motion by scanning faster, the concept of parallel imaging has been shown to provide unique opportunities to detect and correct for motion artifacts [63].”
BackgroundKorst, M. B. J. M., Joosten, F. B. M., Postma, C. T., Jager, G. J., Krabbe, J. K., & Barentsz, J. O. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.174.3.1740629 · Cited by 75
A three‐dimensional spin‐echo or inversion pulse
Pauly, J. M., Hu, B. S., Wang, S. J., Nishimura, D. G., & Macovski, A. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290103 · Cited by 57 · cited 1×
“Transmit SENSE Spatially-confined excitations can be defined using socalled 2D and 3D RF pulses [70,71].”
BackgroundNonuniform Phase-Encode Distributions for MRI Scan Time Reduction
Marseille, G. J., de Beer, R., Fuderer, M., Mehlkopf, A. F., & ORMONDT, D. V. (1996) · Journal of Magnetic Resonance Series B · doi:10.1006/jmrb.1996.0061 · Cited by 54 · cited 1×
“Higher reduction factors can be achieved by sparse sampling [67,68] when taking into account appropriate prior knowledge [69].”
BackgroundCoil Sensitivity Encoding in MR Imaging: Advantages and Disadvantages in Clinical Practice
Kurihara, Y., Yakushiji, Y. K., Tani, I., Nakajima, Y., & CAUTEREN, M. V. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.178.5.1781087 · Cited by 53 · cited 1×
“Clinical advantages of SENSE for several MR imaging techniques have been discussed in terms of increased speed and/or reduced artifact sensitivity in [11].”
BackgroundCONTRAST-ENHANCED THORACIC 3D-MR ANGIOGRAPHY IN INFANTS AND CHILDREN
Holmqvist, C., Larsson, E., Ståhlberg, F., & Laurin, S. (2001) · Acta Radiologica · doi:10.1080/028418501127346233 · Cited by 39
Functional recovery of vision in regenerated optic nerve fibers
Fukuda, Y., Watanabe, M., Sawai, H., & Miyoshi, T. (1998) · Vision Research · doi:10.1016/s0042-6989(98)00005-4 · Cited by 20
Larkman (2001) · doi:10.1002/1522-2586(200102)13:2<313::aid-jmri1045>3.0.co;2-w · cited 1×
“Due to alterations of coil sensitivities in patients which may amount up to some 20%, in-vivo calibration is essential for accurate SENSE reconstruction [9,17].”
Background(1999) · doi:10.1002/1531-8249(199902)45:2<265::aid-ana21>3.0.co;2-3
Cited by
Superparamagnetic Colloids: Controlled Synthesis and Niche Applications
Jeong, U., Teng, X., Wang, Y., Yang, H., & Xia, Y. (2007) · Advanced Materials · doi:10.1002/adma.200600674 · Cited by 982
Kuhl, C. K., Schild, H. H., & Morakkabati, N. (2005) · Radiology · doi:10.1148/radiol.2363040811 · Cited by 263
Self-citationCardiovascular magnetic resonance physics for clinicians: part II
Biglands, J. D., Radjenovic, A., & Ridgway, J. P. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-66 · Cited by 241
A Review of MR Physics: 3T versus 1.5T
Soher, B. J., Dale, B. M., & Merkle, E. M. (2007) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2007.06.002 · Cited by 235
“can also be useful for alleviating SAR levels, either on their own or in conjunction with new RF technologies [36,48,49].”
BackgroundCardiovascular magnetic resonance physics for clinicians: part I
Ridgway, J. P. (2010) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-12-71 · Cited by 218
“Real time imaging therefore suffers from poor temporal and spatial resolution, although the use of parallel imaging [38-40] can help to preserve spatio-temporal resolution.”
Metadata
- Authors
- van den Brink, J. S., Watanabe, Y., Kuhl, C. K., Chung, T., Muthupillai, R., Van Cauteren, M., Yamada, K., Dymarkowski, S., Bogaert, J., Maki, J. H., Matos, C., Casselman, J. W., & Hoogeveen, R. M.
- Venue
- European Journal of Radiology
- Publisher
- Elsevier BV
- Published
- 2003-04
- Volume
- 46
- Issue
- 1
- Pages
- 3-27
- ISSN
- 0720-048X (ISSN-L)
- OpenAlex
- W2097595736
- Cited by
- 160
- References
- 35
- FWCI
- 17.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.