Comparison of the resistance to infection of intestinal submucosa arterial autografts versus polytetrafluoroethylene arterial prostheses in a dog model
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Small intestinal submucosa as a large diameter vascular graft in the dog
Badylak, S. F., Lantz, G. C., Coffey, A., & Geddes, L. A. (1989) · Journal of Surgical Research · doi:10.1016/0022-4804(89)90050-4 · Cited by 613
Self-citationInfection in vascular prostheses
Goldstone, J., & Moore, W. S. (1974) · The American Journal of Surgery · doi:10.1016/s0002-9610(74)80048-6 · Cited by 314
Small Intestinal Submucosa as a Small-Diameter Arterial Graft in the Dog
Lantz, G. C., Badylak, S. F., Coffey, A. C., Geddes, L. A., & Blevins, W. E. (1990) · Journal of Investigative Surgery · doi:10.3109/08941939009140351 · Cited by 210
Self-citationSandusky, G. E., Badylak, S. F., Morff, R. J., Johnson, W. D., & Lantz, G. C. (1992) · PubMed Central · Cited by 177
Self-citationSmall intestinal submucosa as a superior vena cava graft in the dog
Lantz, G. C., Badylak, S. F., Coffey, A. C., Geddes, L. A., & Sandusky, G. E. (1992) · Journal of Surgical Research · doi:10.1016/0022-4804(92)90031-t · Cited by 152
Self-citationRichardson, R. L., Pate, J. W., Wolf, R. Y., Ledes, C. P., & Hopson, W. B. (1970) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)42421-5 · Cited by 34
The development of vasa vasorum of the human aorta in various conditions. A morphometric study.
Okuyama, K., Yaginuma, G.-Y., Takahashi, T., Sasaki, H., & Mori, S. (1988) · PubMed · Cited by 25
Infrarenal Aortic Aneurysmectomy
Smead, W. L., & Vaccaro, P. S. (1983) · Surgical Clinics of North America · doi:10.1016/s0039-6109(16)43188-9 · Cited by 12
Cited by
Breuing, K., Butler, C. E., Ferzoco, S., Franz, M., Hultman, C. S., Kilbridge, J. F., Rosen, M., Silverman, R. P., & Vargo, D. (2010) · Surgery · doi:10.1016/j.surg.2010.01.008 · Cited by 1,031
The extracellular matrix as a biologic scaffold material
Badylak, S. F. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.04.043 · Cited by 1,022
Self-citationImmune response to biologic scaffold materials
Badylak, S. F., & Gilbert, T. W. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.003 · Cited by 857
Self-citationAcellular vascular tissues: natural biomaterials for tissue repair and tissue engineering
Schmidt, C. E., & Baier, J. M. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00148-4 · Cited by 762
Xenogeneic extracellular matrix as a scaffold for tissue reconstruction
Badylak, S. F. (2004) · Transplant Immunology · doi:10.1016/j.trim.2003.12.016 · Cited by 747
Self-citationBadylak, S. F., Tullius, R., Kokini, K., Shelbourne, K. D., Klootwyk, T., Voytik, S. L., Kraine, M. R., & Simmons, C. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290809 · Cited by 501
Self-citationMacrophage Participation in the Degradation and Remodeling of Extracellular Matrix Scaffolds
Valentin, J. E., Stewart-Akers, A. M., Gilbert, T. W., & Badylak, S. F. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0419 · Cited by 356
Self-citationBrennan, E. P., Reing, J., Chew, D., Myers-Irvin, J. M., Young, E. J., & Badylak, S. F. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.2949 · Cited by 239
Self-citationChemoattraction of Progenitor Cells by Remodeling Extracellular Matrix Scaffolds
Beattie, A. J., Gilbert, T. W., Guyot, J. P., Yates, A. J., & Badylak, S. F. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0162 · Cited by 219
“ECM scaffolds have been shown to resist infection following deliberate bacterial contamination in preclinical studies 28,29 and spon-taneous contamination in the clinical environment.”
InfluentialSelf-citationShort-term Outcomes With Small Intestinal Submucosa for Ventral Abdominal Hernia
Helton, W. S. (2005) · Archives of Surgery · doi:10.1001/archsurg.140.6.549 · Cited by 196
“Extracellular matrices derived from porcine small intestinal submucosa possess antimicrobial activity(37) and have been reported to be resistant to bacterial infection due to rapid angiogenesis and integration in host tissues.(35,36,38) Based on this experimental evidence, Franklin and colleagues(18,34) investigated t…”
Zantop, T., Gilbert, T. W., Yoder, M. C., & Badylak, S. F. (2006) · Journal of Orthopaedic Research · doi:10.1002/jor.20071 · Cited by 186
Self-citationSmall Bowel Tissue Engineering Using Small Intestinal Submucosa as a Scaffold
Chen, M. K., & Badylak, S. F. (2001) · Journal of Surgical Research · doi:10.1006/jsre.2001.6199 · Cited by 183
Self-citationAntimicrobial Activity Associated with Extracellular Matrices
Sarikaya, A., Record, R., Wu, C.-C., Tullius, B., Badylak, S., & Ladisch, M. (2002) · Tissue Engineering · doi:10.1089/107632702753503063 · Cited by 180
“…repair, 1 Achilles tendon repair, 2,3 dura mater replacement 4,5 and body wall repair, 6,7 SIS has also showed a resistance to deliberate infection in preclinical animal studies 8,9 and has now been utilized in over 10,000 human patients without reports of complications, including injection.”
Self-citationFranklin, M. E., Gonzalez, J. J., & Glass, J. L. (2004) · Hernia · doi:10.1007/s10029-004-0208-7 · Cited by 174
“Badylak and colleagues deliberately challenged SIS and expanded polytetrafluoroethylene (ePTFE) infrarenal aortic grafts with Staphylococcus aureus [9].”
BackgroundFranklin, M. E., Treviño, J. M., Portillo, G., Vela, I., Glass, J. L., & González, J. J. (2008) · Surgical Endoscopy · doi:10.1007/s00464-008-0005-y · Cited by 173
“In 1994, Badylak and colleagues deliberately challenged SIS and expanded polytetrafluoroethylene infrarenal aortic grafts with Staphylococcus aureus [1].”
BackgroundAn extracellular matrix scaffold for esophageal stricture prevention after circumferential EMR
Nieponice, A., McGrath, K., Qureshi, I., Beckman, E. J., Luketich, J. D., Gilbert, T. W., & Badylak, S. F. (2009) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2008.04.022 · Cited by 170
Self-citationUeno, T., Pickett, L. C., de la Fuente, S. G., Lawson, D. C., & Pappas, T. N. (2004) · Journal of Gastrointestinal Surgery · doi:10.1016/j.gassur.2003.09.025 · Cited by 161
He, M., & Callanan, A. (2013) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2012.0340 · Cited by 159
Regulation of decellularized matrix mediated immune response
Chakraborty, J., Roy, S., & Ghosh, S. (2020) · Biomaterials Science · doi:10.1039/c9bm01780a · Cited by 130
Crosslinking decreases the hemocompatibility of decellularized, porcine small intestinal submucosa
Glynn, J. J., Polsin, E. G., & Hinds, M. T. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.11.038 · Cited by 30
“Studies using SIS for cardiovascular applications have generally demonstrated low rates of thrombosis that were similar to autologous saphenous vein[18] and ePTFE.[22] However, unlike the thorough characterization of the inflammatory and immune responses to SIS, the thrombotic response has not been well-studied.”
Method
Metadata
- Authors
- Badylak, S. F., Coffey, A. C., Lantz, G. C., Tacker, W. A., & Geddes, L. A.
- Venue
- Journal of Vascular Surgery
- Publisher
- Elsevier BV
- Published
- 1994-03
- Volume
- 19
- Issue
- 3
- Pages
- 465-472
- ISSN
- 0741-5214 (ISSN-L)
- OpenAlex
- W1987495865
- Cited by
- 159
- References
- 8
- FWCI
- 1.23
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.