Reproducibility of home, ambulatory, and clinic blood pressure: implications for the design of trials for the assessment of antihypertensive drug efficacy
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Background The aims of this study were to compare the reproducibility of blood pressure (BP) measured in the clinic (CBP), at home (HBP), and by ambulatory monitoring (ABP), and to assess its implications on the accuracy of antihypertensive drug trials. Methods A total of 133 untreated subjects with elevated CBP were assessed with repeated measurements of CBP (five visits within 3 months), HBP (6 workdays within 2 weeks), and ABP (twice, 2 weeks apart). The reproducibility of CBP (one visit), HBP (2 days), and ABP (24 h) was quantified using the SD of differences (SDD) between repeated measurements. The number of subjects required in a comparative trial of two drugs was calculated for each measurement method. Results We found that HBP provided the lowest SDD values (6.9/4.7 mm Hg, systolic/diastolic, compared with 8.3/5.6 for ABP and 11.0/6.6 for CBP). For a parallel trial aiming to detect a difference in the effect of two drugs of 10 mm Hg systolic BP, 51 subjects would be required when using CBP compared with 29 using ABP and 20 using HBP (73, 53 and 37 subjects, respectively, for the detection of a 5 mm Hg difference in diastolic BP). Conclusions The study shows that HBP seems to have superior reproducibility compared with both CBP and ABP. In addition, HBP can improve the accuracy of antihypertensive drug trials, thereby reducing the sample size required.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“BP readings obtained using traditional methods show only moderate reproducibility, with out-of-office BP measurements being more reproducible than those taken in the office63.”
From Blood pressure and its variability: classic and novel measurement techniques (2022) · cites this paper as [63]
In the citing paper
“The reproducibility of any BP measurement method improves by increasing the number of BP readings”
In the citing paper
“one of the advantages of HBPM is the larger number of readings that can be obtained compared with office BP (OBP) measurement [17,18].”
In the citing paper
“Cross-sectional studies have mainly focused on the effect of different numbers of readings and days on average HBP, HBP variability and reproducibility; cross-classification according to office and home BP (normotension, white-coat, masked and sustained hypertension); association with ABPM values and association with indices of preclinical target-organ damage [17,18,127–133]”
In the citing paper
“During the last two decades, HBPM has been used increasingly in clinical hypertension research [17,155,267–273].”
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The reproducibility of average ambulatory, home, and clinic pressures.
James, G. D., Pickering, T. G., Yee, L. S., Harshfield, G. A., Riva, S., & Laragh, J. H. (1988) · Hypertension · doi:10.1161/01.hyp.11.6.545 · Cited by 249
Asmar, R., & Zanchetti, A. (2000) · Journal of Hypertension · doi:10.1097/00004872-200018050-00001 · Cited by 213
Self-monitoring of blood pressure at home: how many measurements are needed?
Stergiou, G. S., Skeva, I. I., Zourbaki, A. S., & Mountokalakis, T. D. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816060-00002 · Cited by 212
Self-citationTrazzi, S., Mutti, E., Frattola, A., Imholz, B., Parati, G., & Mancia, G. (1991) · Journal of Hypertension · doi:10.1097/00004872-199102000-00003 · Cited by 158
Stergiou, G. S., Zourbaki, A. S., Skeva, I. I., & Mountokalakis, T. D. (1998) · American Journal of Hypertension · doi:10.1016/s0895-7061(98)00038-7 · Cited by 132
Self-citationStergiou, G. S., Skeva, I. I., Baibas, N. M., Kalkana, C. B., Roussias, L. G., & Mountokalakis, T. D. (2000) · Journal of Hypertension · doi:10.1097/00004872-200018120-00007 · Cited by 128
Self-citationReproducibility of Home Blood Pressure Measurements Over a 1-Year Period
Sakuma, M. (1997) · American Journal of Hypertension · doi:10.1016/s0895-7061(97)00117-9 · Cited by 121
Coats, A. J. S., Radaelli, A., Clark, S. J., Conway, J., & Sleight, P. (1992) · Journal of Hypertension · doi:10.1097/00004872-199204000-00011 · Cited by 96
Feasibility Study of N-of-1 Trials With Blood Pressure Self-Monitoring in Hypertension
Chatellier, G., Day, M., Bobrie, G., & Menard, J. (1995) · Hypertension · doi:10.1161/01.hyp.25.2.294 · Cited by 72
Vaur, L., Dubroca, I., Dutrey-Dupagne, C., Genes, N., Châtellier, G., Bouvier-d'Yvoire, M., Elkik, F., & Ménard (1998) · PubMed · Cited by 70
Research works printed but not linked: 3
- 1988, Hypertension, 1, 545
- 1995, ARCH MAL COEUR, 88, 1165
- 1998, Blood pressure monitoring, 3, 19
Cited by
Items 201–267 of 267
Dominiczak, A. F., Champvallins, M. D., Brzozowska-Villatte, R., & Asmar, R. G. (2019) · Journal of Hypertension · doi:10.1097/hjh.0000000000002177 · Cited by 4
“In that context, these last two measurements are a valuable supplement to office values [6,35,36] to overcome issues such as white-coat hypertension [5,6,10,37] and have been shown to be more predictive of cardiovascular risk than office BP [38–40].”
BackgroundClinical Significance of Home Blood Pressure and Its Possible Practical Application
Imai, Y. (2012) · Journal of the Korean Society of Hypertension · doi:10.5646/jksh.2012.18.1.1 · Cited by 3
Kyriakoulis, K. G., Κόλλιας, Α., Bilo, G., Soranna, D., Liu, C., Pengo, M. F., Zambon, A., Zhang, W., Destounis, A., Wang, J., et al. (2024) · Journal of Hypertension · doi:10.1097/hjh.0000000000003730 · Cited by 4
Self-citationValidity of ambulatory blood pressure monitoring in daily primary healthcare practice in France
Mazalovic, K., Morlon, F., Beis, J. N., Duglet, P.-E., Cottin, Y., & Zabawa, C. (2018) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000342 · Cited by 4
Feitosa, A. D. M., Gomes, M. A. M., & Júnior, D. M. (2005) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x2005001600012 · Cited by 18
Self-monitoring for improving control of blood pressure in patients with hypertension
Qamar, N., Bray, E. P., Glynn, L. G., Fahey, T. P., Mant, J., HOLDER, R. L., & McManus, R. J. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010311 · Cited by 3
Home (Self) Monitoring of Blood Pressure
Parati, G., & Ochoa, J. E. (2015) · Springer eBooks · doi:10.1007/978-3-319-22771-9_2 · Cited by 4
Flaws in Dose-Finding of Antihypertensive Drugs
Stergiou, G. S. (2007) · American Journal of Cardiovascular Drugs · doi:10.2165/00129784-200707050-00005 · Cited by 3
Self-citationRenal denervation for hypertension: what is needed, and what is next
Kandzari, D. E. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehz369 · Cited by 5
“Although paralleled by office measurements, the study relies on ABPM as a more stable and reproducible assessment of blood pressure that is less susceptible to measurement bias, placebo effects, and day to day variability.(14) In addition, ambulatory blood pressure is more strongly correlated with cardiovascular risk…”
MethodTanner, R. M., Jaeger, B. C., Bradley, C., Thomas, S. J., Min, Y., Hardy, S. T., Irvin, M. R., Shimbo, D., Schwartz, J. E., & Muntner, P. (2024) · American Journal of Hypertension · doi:10.1093/ajh/hpae133 · Cited by 3
European Hypertension Guidelines: Similarities and What the Practicing Physician Should Keep in Mind
Zeniodi, M. E., Τσαγανός, Θ., Menti, A., Komnianou, A., Κόλλιας, Α., & Stambolliu, E. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15020859 · Cited by 4
Methodology and Applicability of Home Blood Pressure Monitoring in Children and Adolescents
Stergiou, G. S., & Ntineri, A. (2017) · Springer eBooks · doi:10.1007/978-3-319-31420-4_45-1 · Cited by 3
Self-citationReproducibility of ambulatory blood pressure measurement in patients with coronary heart disease
(2014) · Cardiovascular Medicine · doi:10.4414/cvm.2014.00266 · Cited by 2
Self-monitoring for improving control of blood pressure in patients with hypertension
Doogue, R., Hayes, P., Tucker, K. L., Fahey, T. P., Sheikhi, A., Koshiaris, C., & Glynn, L. G. (2021) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010311.pub2 · Cited by 3
Exarchakis, A., Bayo, S., Fink, A. M., & Martinez, D. (2025) · Pediatric Research · doi:10.1038/s41390-025-04199-3 · Cited by 3
“12,13 14 – 17 Additionally, studies have shown that ambulatory blood pressure monitoring itself may disrupt sleep due to cuff in fl ation, particularly within the fi rst 24 h of use, potentially compromising both sleep quality and the accuracy of the measurements.”
Stergiou, G. S., Kyriakoulis, K. G., & Κόλλιας, Α. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001466 · Cited by 2
“ABP and HBP are more standardized methods in terms of devices (automated) and observers (self-measured HBP and automated ABP) and are known to provide more reproducible BP values, which can identify BP differences with higher accuracy [11].”
MethodSelf-citationMethodology and Applicability of Home Blood Pressure Monitoring in Children and Adolescents
Stergiou, G. S., & Ntineri, A. (2023) · Springer eBooks · doi:10.1007/978-3-031-06231-5_45 · Cited by 2
Self-citationHome Monitoring of Blood Pressure
Pickering, T. G. (2007) · Elsevier eBooks · doi:10.1016/b978-1-4160-3053-9.50012-3 · Cited by 2
Donald, G., Lorimer, K., Lawrence, M., Stringer, J., Wong, R., Winter, A., & Flowers, P. (2020) · European Journal of Integrative Medicine · doi:10.1016/j.eujim.2020.101088 · Cited by 2
Baker-Smith, C. M., & Seeman, T. (2026) · Pediatric Nephrology · doi:10.1007/s00467-026-07242-5 · Cited by 2
“…(3) only ABPM can detect isolated nocturnal hypertension; and (4) when combined with education and counseling, HBPM, compared to office BP assessment alone, is best for improved long-term BP control (combined with self-titration of medication) [11, 12], including in children and adolescents [13].”
Improving blood pressure control using digital communication methods in Serbia
Tasic, N., Tasic, D., Kovacevic, Z., Filipovic, M., Arsic, M., Bozovic-Ogarevic, S., Despotovic, B., Bojic, M., Maksimovic, Z., Zdravkovic, N., et al. (2022) · Diagnostics · doi:10.3390/diagnostics12040914 · Cited by 1
“13 billion people in the world suffer from HTA [1,2], and the prevalence of hypertension in Europe ranges from 9% to”
BackgroundHome Blood Pressure Monitoring Schedule
Niiranen, T. J., McManus, R. J., Ohkubo, T., & Stergiou, G. S. (2020) · Updates in Hypertension and Cardiovascular Protection · doi:10.1007/978-3-030-23065-4_6 · Cited by 1
Self-citationStyczyński, G., Kalinowski, P., Cienszkowska, K., Ludwiczak, M., Strzelczyk, J., & Szmigielski, C. A. (2026) · Hypertension Research · doi:10.1038/s41440-026-02602-y · Cited by 1
van Vliet, M., Aalberts, J. J. J., Hamelinck, C., Hauer, A. D., Hoftijzer, D., Monnink, S. H. J., Schipper, J., & Ronner, E. (2026) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000804 · Cited by 1
Lee, J., Wang, X., Liu, C., Pathiravasan, C. H., Benjamin, E. J., McManus, D. D., & Murabito, J. M. (2024) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2024.01.001 · Cited by 1
“HBPM has some advantages compared to of fi ce-based measurements, including enabling the diagnosis of white-coat and masked hypertension, 17 being more reproducible, 18 and better predicting CVD morbidity and mortality.”
Karnjanapiboonwong, A., Chaikledkaew, U., Anothaisintawee, T., Praditsitthikorn, N., Dejthevaporn, C., & Thakkinstian, A. (2024) · PLoS ONE · doi:10.1371/journal.pone.0308851 · Cited by 1
Odaguchi, H., Wakasugi, A., Oikawa, T., & Hanawa, T. (2012) · 和漢医薬学雑誌 · doi:10.11339/jtm.29.10 · Cited by 1
1年間の介入指導に伴う睡眠,運動,体重からの家庭血圧変動要因の推定
水庫, 功., 正樹, 関., 俊世, 田., & 穣, 木. (2010) · Seitai ikougaku/Seitai ikogaku · doi:10.11239/jsmbe.48.139 · Cited by 1
Home Blood Pressure Measurement: A Review
Kaur, G., Arora, A. S., & Jain, V. K. (2010) · International Journal of Computational Models and Algorithms in Medicine · doi:10.4018/jcmam.2010100104 · Cited by 1
Andrade-Lima, A., Chehuen, M. D. R., da Silva, N. D., Fecchio, R. Y., Peçanha, T., Brito, L. C., Miyasato, R. S., Leicht, A. S., & Forjaz, C. L. M. (2018) · Annals of Vascular Surgery · doi:10.1016/j.avsg.2018.08.089 · Cited by 1
Home Monitoring of Blood Pressure
Stergiou, G. S., & Κόλλιας, Α. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-88369-6.00010-4 · Cited by 1
Self-citationHome blood pressure monitoring in an ethnically diverse inner-city cardiology practice.
Qureshi, G. H., Salciccioli, L. F., Clark, L. T., & Lazar, J. (2008) · PubMed · Cited by 1
Home Monitoring of Blood Pressure
Campbell, P. T., & White, W. B. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4377-2766-1.00005-3 · Cited by 1
Why it is Important to Measure Blood Pressure at Home Rather than Just at the Clinic?
Daud, A. M. (2011) · Asia Pacific Cardiology · doi:10.15420/apc.2011:3:1:41 · Cited by 1
Home Blood Pressure Monitoring in Prehypertension and Hypertension
Ntineri, A., Κόλλιας, Α., & Stergiou, G. S. (2018) · Updates in hypertension and cardiovascular protection · doi:10.1007/978-3-319-75310-2_29 · Cited by 3
Self-citationLa automedida de la presión arterial en el domicilio
Vinyoles, E., Soldevila, N., Tafalla, M., Vanrell, M., & Agudo-Ugena, J. (2022) · FMC - Formación Médica Continuada en Atención Primaria · doi:10.1016/j.fmc.2022.01.016 · Cited by 1
Protocolos de validación de los dispositivos automáticos de medición de la presión arterial
Caro, J. L. L., Roca, G. C. R., Moreno, F. J. A., & Ródenas, L. M. A. (2004) · Medicina de Familia SEMERGEN · doi:10.1016/s1138-3593(04)74278-1 · Cited by 1
Stergiou, G. S., Efstathiou, S. P., Inglis, G., Connell, J. M. C., McInnes, G. T., & Mountokalakis, T. D. (2005) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001918 · Cited by 1
Self-citationSelf-Monitoring of Blood Pressure
Pickering, T. G. (2007) · Humana Press eBooks · doi:10.1007/978-1-59259-978-3_1 · Cited by 2
Klinik der koronaren Herzerkrankung I: Stabile Angina pectoris, stumme Myokardischämie
Bestehorn, H.-P., & Roskamm, H. (2004) · Springer eBooks · doi:10.1007/978-3-642-18649-3_21
¿Sabemos manejar la hipertensión arterial refractaria?
Peña, O. G., de Vigón, R. O., Ugarte, I., Moina, I., & Lezama, J. A. (2005) · Gaceta Médica de Bilbao · doi:10.1016/s0304-4858(05)74497-8
Home Blood Pressure Measurement - Epidemiology and Clinical Application
Niiranen, T. (2008) · STM:n Hallinnonalan avoin julkaisuarkisto (Julkari) · Cited by 2
The Clinical Utility of Patient-Measured Blood Pressure at Home in the Management of Hypertension
Dart, R. A. (2005) · Clinical Medicine & Research · doi:10.3121/cmr.3.3.134
Reproducibility of ambulatory blood pressure mea- surement in patients with coronary heart disease
Roas, S., Sudano, I., Ruschitzka, F. T., Lüscher, T. F., & Noll, G. (2014) · Zurich Open Repository and Archive (University of Zurich)
24-hour blood pressure monitoring: its efficacy and techniques
O'Brien, E. T., & Verdecchia, P. (2011) · Hot Topics in Hypertension · doi:10.4147/hth-111200
A relevância da monitorização residencial da pressão arterial - MRPA
Antônio, M., Gomes, M., & Mion, D. (2003)
[Home blood pressure measurement].
Niiranen, T., & Jula, A. (2009) · PubMed · Cited by 6
Kontrola ciśnienia tętniczego w warunkach domowych
Parati, G., Bilo, G., Kjeldsen, S. E., & Mancia, G. (2009) · Choroby Serca i Naczyń · Cited by 1
HIV infection and hypertension: Epidemiological and pathogenetic aspects
Manner, I. W. (2013) · NVA (Nasjonalt vitenarkiv)
Nahler, A., Lambert, T., & Reiter, C. G. (2016) · Archives of Medicine · doi:10.21767/1989-5216.1000174
“It is well established that the reproducibility of BP levels is much higher by using ABPM [11,12].”
BackgroundNeto, J. D. D. S. (2016) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.5.2016.tde-06012016-111038
Reprodutibilidade da hipotensão pós-exercício e de seus mecanismos hemodinâmicos e autonômicos
Fecchio, R. Y. (2018) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.39.2018.tde-20122017-113940
Out-of-Office Blood Pressure Monitoring
Pickering, T. G. (2007) · Elsevier eBooks · doi:10.1016/b978-0-323-03961-1.50048-9
Home Blood Pressure Monitoring in Clinical Research
Ntineri, A., Kario, K., Wang, J., White, W. B., & Stergiou, G. S. (2019) · Updates in hypertension and cardiovascular protection · doi:10.1007/978-3-030-23065-4_10
Self-citationImproving the quality of blood pressure measurements in an outpatient diabetes clinic
Iyengar, J. J., Johnson, M., Khairi, S., Fennelly, J. E., & Wyckoff, J. (2021) · BMJ Open Quality · doi:10.1136/bmjoq-2020-000917 · Cited by 1
Yeung, S. E. (2014) · Summit (Simon Fraser University)
Vazeou, A., & Stergiou, G. S. (2022) · Biomarkers in disease · doi:10.1007/978-3-030-81303-1_37-1
Self-citationShin, J., Lee, Y., Ihm, S., Shin, J., Kim, H., Kim, B. S., Park, H.-C., Lim, Y., Park, J., Heo, R., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-04913-9
Home Blood Pressure Measurement: A Review
Kaur, G., Arora, A. S., & Jain, V. K. (2012) · IGI Global eBooks · doi:10.4018/978-1-4666-0282-3.ch017
Methodology and Applicability of Home Blood Pressure Monitoring in Children and Adolescents
Stergiou, G. S., & Ntineri, A. (2022) · Springer eBooks · doi:10.1007/978-3-319-31420-4_45-2
Self-citationVazeou, A., & Stergiou, G. S. (2022) · Biomarkers in disease · doi:10.1007/978-3-031-08014-2_37
Self-citationWeihrauch, T., Lemcke, J., Büschges, J. C., Allen, J., Schmich, P., Kintscher, U., Maier, B., & Neuhauser, H. K. (2024) · Journal of Hypertension · doi:10.1097/hjh.0000000000003932
Miao, H., Zhou, Z., Yin, Z., Li, X., Zhang, J., & Zhang, Y. (2025) · BMJ Open · doi:10.1136/bmjopen-2025-100482
Actualización en monitoreo domiciliario de la presión arterial
Waisman, G. D., Barochiner, J., Aparicio, L. S., & Cuffaro, P. E. (2011) · Revista del Hospital Italiano de Buenos Aires · doi:10.51987/rev.hosp.ital.b.aires.v31i3.970
Mancusi, C., Šinigoj, P., Antza, C., Belančić, A., Motiejūnaitė, J., Tähtisalo, H. S., Ferrão, D., & Palatini, P. (2026) · Blood Pressure · doi:10.1080/08037051.2026.2646368
The PLANET-KT Randomized Controlled Trial: Plant-Based Diet Beyond Blood Pressure Control
Kitpermkiat, R., Thotsiri, S., Shantavasinkul, P. C., Payungporn, S., Tantisattamo, E., Butsing, N., Charoenthanakit, C., Thanachoterassakul, A., Rodphech, V., Taonam, N., et al. (2026) · Kidney International Reports · doi:10.1016/j.ekir.2026.107174
Simple Screening Instruments for Chronic Disease & Personalised Prevention at the Workplace
Niessen, M. A. J. (2014)
Metadata
- Authors
- Stergiou, G. S., Baibas, N. M., Gantzarou, A. P., Skeva, I. I., Kalkana, C. B., Roussias, L. G., & Mountokalakis, T. D.
- Affiliations
- Sotiria General Hospital (GR)
- Corresponding author
- Stergiou, G. S.
- ORCID
- Stergiou, G. S.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 2002-02-01
- Volume
- 15
- Issue
- 2
- Pages
- 101-104
- ISSN
- 0895-7061 (ISSN-L)
- 1941-7225
- OpenAlex
- W2101549027
- Semantic Scholar
- fd59daf9b2e546a8f9a47788ac3613a683fb083c
- Cited by
- 268
- References
- 17
- Citations by year
- 2026: 5 · 2025: 3 · 2024: 11 · 2023: 9 · 2022: 13 · 2021: 12 · 2020: 8 · 2019: 11 · 2018: 13 · 2017: 10 · 2016: 9 · 2015: 15 · 2014: 13 · 2013: 10 · 2012: 13
- FWCI
- 7.42
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Hypertension (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Clinical Trials
- Keywords
- home blood pressure monitoring, ambulatory blood pressure monitoring, office blood pressure, antihypertensive drug trials, sample size determination, measurement variability, hypertension
- MeSH terms
- Adult, Antihypertensive Agents, Blood Pressure Determination, Clinical Trials as Topic, Female, Home Care Services, Humans, Hypertension, Male, Middle Aged, Office Visits, Research Design, Reproducibility of Results, Blood Pressure Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.