Reproducibility of home, ambulatory, and clinic blood pressure: implications for the design of trials for the assessment of antihypertensive drug efficacy
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Background The aims of this study were to compare the reproducibility of blood pressure (BP) measured in the clinic (CBP), at home (HBP), and by ambulatory monitoring (ABP), and to assess its implications on the accuracy of antihypertensive drug trials. Methods A total of 133 untreated subjects with elevated CBP were assessed with repeated measurements of CBP (five visits within 3 months), HBP (6 workdays within 2 weeks), and ABP (twice, 2 weeks apart). The reproducibility of CBP (one visit), HBP (2 days), and ABP (24 h) was quantified using the SD of differences (SDD) between repeated measurements. The number of subjects required in a comparative trial of two drugs was calculated for each measurement method. Results We found that HBP provided the lowest SDD values (6.9/4.7 mm Hg, systolic/diastolic, compared with 8.3/5.6 for ABP and 11.0/6.6 for CBP). For a parallel trial aiming to detect a difference in the effect of two drugs of 10 mm Hg systolic BP, 51 subjects would be required when using CBP compared with 29 using ABP and 20 using HBP (73, 53 and 37 subjects, respectively, for the detection of a 5 mm Hg difference in diastolic BP). Conclusions The study shows that HBP seems to have superior reproducibility compared with both CBP and ABP. In addition, HBP can improve the accuracy of antihypertensive drug trials, thereby reducing the sample size required.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“BP readings obtained using traditional methods show only moderate reproducibility, with out-of-office BP measurements being more reproducible than those taken in the office63.”
From Blood pressure and its variability: classic and novel measurement techniques (2022) · cites this paper as [63]
In the citing paper
“The reproducibility of any BP measurement method improves by increasing the number of BP readings”
In the citing paper
“one of the advantages of HBPM is the larger number of readings that can be obtained compared with office BP (OBP) measurement [17,18].”
In the citing paper
“Cross-sectional studies have mainly focused on the effect of different numbers of readings and days on average HBP, HBP variability and reproducibility; cross-classification according to office and home BP (normotension, white-coat, masked and sustained hypertension); association with ABPM values and association with indices of preclinical target-organ damage [17,18,127–133]”
In the citing paper
“During the last two decades, HBPM has been used increasingly in clinical hypertension research [17,155,267–273].”
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The reproducibility of average ambulatory, home, and clinic pressures.
James, G. D., Pickering, T. G., Yee, L. S., Harshfield, G. A., Riva, S., & Laragh, J. H. (1988) · Hypertension · doi:10.1161/01.hyp.11.6.545 · Cited by 249
Asmar, R., & Zanchetti, A. (2000) · Journal of Hypertension · doi:10.1097/00004872-200018050-00001 · Cited by 213
Self-monitoring of blood pressure at home: how many measurements are needed?
Stergiou, G. S., Skeva, I. I., Zourbaki, A. S., & Mountokalakis, T. D. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816060-00002 · Cited by 212
Self-citationTrazzi, S., Mutti, E., Frattola, A., Imholz, B., Parati, G., & Mancia, G. (1991) · Journal of Hypertension · doi:10.1097/00004872-199102000-00003 · Cited by 158
Stergiou, G. S., Zourbaki, A. S., Skeva, I. I., & Mountokalakis, T. D. (1998) · American Journal of Hypertension · doi:10.1016/s0895-7061(98)00038-7 · Cited by 132
Self-citationStergiou, G. S., Skeva, I. I., Baibas, N. M., Kalkana, C. B., Roussias, L. G., & Mountokalakis, T. D. (2000) · Journal of Hypertension · doi:10.1097/00004872-200018120-00007 · Cited by 128
Self-citationReproducibility of Home Blood Pressure Measurements Over a 1-Year Period
Sakuma, M. (1997) · American Journal of Hypertension · doi:10.1016/s0895-7061(97)00117-9 · Cited by 121
Coats, A. J. S., Radaelli, A., Clark, S. J., Conway, J., & Sleight, P. (1992) · Journal of Hypertension · doi:10.1097/00004872-199204000-00011 · Cited by 96
Feasibility Study of N-of-1 Trials With Blood Pressure Self-Monitoring in Hypertension
Chatellier, G., Day, M., Bobrie, G., & Menard, J. (1995) · Hypertension · doi:10.1161/01.hyp.25.2.294 · Cited by 72
Vaur, L., Dubroca, I., Dutrey-Dupagne, C., Genes, N., Châtellier, G., Bouvier-d'Yvoire, M., Elkik, F., & Ménard (1998) · PubMed · Cited by 70
Research works printed but not linked: 3
- 1988, Hypertension, 1, 545
- 1995, ARCH MAL COEUR, 88, 1165
- 1998, Blood pressure monitoring, 3, 19
Cited by
Items 101–200 of 267
Bell, K., Doust, J. A., McGeechan, K., Horvath, A. R., Barratt, A. L., Hayen, A. D., Semsarian, C., & Irwig, L. (2020) · Journal of Hypertension · doi:10.1097/hjh.0000000000002614 · Cited by 29
Do we need out-of-office blood pressure in every patient?
Parati, G., & Valentini, M. (2007) · Current Opinion in Cardiology · doi:10.1097/hco.0b013e3281bd8835 · Cited by 31
Stergiou, G. S., Alamara, C. V., Skeva, I., & Mountokalakis, T. D. (2004) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001640 · Cited by 30
Self-citationMonitoring and Evaluation of Blood Pressure Changes With a Home Healthcare System
TAMURA, T., Mizukura, I., Sekine, M., & Kimura, Y. (2011) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2156804 · Cited by 27
Self-monitoring of blood pressure should be used in clinical trials
Baguet, J.-P., & Mallion, J.-M. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200202000-00011 · Cited by 27
Thirty-minute compared to standardised office blood pressure measurement in general practice
Haan, N. S., van der Wel, M., Schoenmakers, G., Boudewijns, S., Peer, P. G. M., van Weel, C., Thien, T. A., & Bakx, C. (2011) · British Journal of General Practice · doi:10.3399/bjgp11x593875 · Cited by 25
Phenotypes of masked hypertension: Isolated ambulatory, isolated home and dual masked hypertension
Stergiou, G. S., Kyriakoulis, K. G., McManus, R. J., Andreadis, E. A., Jula, A., Kollias, A., Lindroos, A., Ntineri, A., Schwartz, C., & Niiranen, T. J. (2020) · Journal of Hypertension · doi:10.1097/hjh.0000000000002270 · Cited by 24
“Several studies have shown that the reproducibility of both ABP and HBP is superior to that of OBP, yet this is still imperfect and diagnostic disagreement of repeated ABP or HBP is not uncommon [16].”
BackgroundSelf-citationJohnson, J. A., Gong, Y., Bailey, K. R., COOPERDEHOFF, R., Chapman, A., Turner, S. T., Schwartz, G. L., Campbell, K. M., Schmidt, S. O., Beitelshees, A. L., et al. (2009) · Clinical Pharmacology & Therapeutics · doi:10.1038/clpt.2009.101 · Cited by 25
Rasmussen, P. V., Nielsen, J. B., Pietersen, A. H., Graff, C., Lind, B., Struijk, J. J., OLESEN, M. S., Haunsø, S., Køber, L., Svendsen, J. H., et al. (2014) · Journal of the American Heart Association · doi:10.1161/jaha.113.000549 · Cited by 25
Race differences in the physical and psychological impact of hypertension labeling
Spruill, T. M., Gerber, L. M., Schwartz, J. E., Pickering, T. G., & Ogedegbe, G. G. (2012) · American Journal of Hypertension · doi:10.1038/ajh.2011.258 · Cited by 27
Kawabe, H., & Saito, I. (2007) · Hypertension Research · doi:10.1291/hypres.30.845 · Cited by 24
“However, the correlation between the periods for casual blood pressure in this study was similar to that of a former report (27).”
ResultMoffatt, F. W., HODNETT, E. D., Esplen, M. J., & Watt‐Watson, J. (2010) · Birth · doi:10.1111/j.1523-536x.2010.00424.x · Cited by 34
Chazova, I. E., Михайловна, Ч. Н., Blinova, N. V., Владимировна, А. А., Alekseeva, T. A., Ambatiello, L. G., Balanova, Y. А., Bragina, A. E., Danilov, N. M., Drapkina, O. M., et al. (2024) · Systemic Hypertension · doi:10.38109/2075-082x-2024-4-5-109 · Cited by 28
Ku, E., McCulloch, C. E., Warady, B. A., Furth, S. L., Grimes, B. A., & Mitsnefes, M. M. (2018) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.09630917 · Cited by 23
Reproducibility of ambulatory blood pressure changes from the initial values on two different days
Ash, G. I., Walker, T. J., Olson, K. M., Stratton, J. H., Gómez, A. L., Kraemer, W. J., Volek, J. S., & Pescatello, L. S. (2013) · Clinics · doi:10.6061/clinics/2013(12)06 · Cited by 28
“In contrast, studies that included subjects with hypertension found higher standard deviation of the difference values ranging from 4–13 mmHg, independent of whether ambulatory BP measurements were separated by several weeks (4,5,7,9,12) or by several months (6,10,13).”
ResultThe optimal schedule for self-home blood pressure monitoring
Stergiou, G. S., & Ntineri, A. (2015) · Journal of Hypertension · doi:10.1097/hjh.0000000000000509 · Cited by 22
“reproducible values than the 24-h average [22] and nocturnal ABPM is omitted, which appears to be the best aspect of the method in terms of prognostic ability [32].”
BackgroundMethodSelf-citationGanti, V. G., Carek, A. M., Jung, H., Srivatsa, A. V., Cherry, D., Johnson, L. N., & Inan, O. T. (2021) · JMIR mhealth and uhealth · doi:10.2196/27466 · Cited by 25
“In addition, digital health technologies that accurately estimate BP could potentially be used to titrate BP medications for patients with hypertension from the comfort of their homes [7,74].”
MethodJohansson, J. K., Niiranen, T., Puukka, P. J., & Jula, A. (2010) · Blood Pressure · doi:10.3109/08037051.2010.518675 · Cited by 24
“If the answer to the question “ Do you snore when sleeping? (Ask others if you are not sure) ” was “ yes ” , then the following additional questions were addressed: (1) “ How often do you snore? ” ; (2) “ How does your snoring sound like? (Ask others if needed) ” and (3) “ Have you noticed (or have others noticed) res…”
BackgroundCuspidi, C., Meani, S., Sala, C., Valerio, C., Fusi, V., Zanchetti, A., & Mancia, G. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e3280119025 · Cited by 22
Uneven Accuracy of Home Blood Pressure Measurement: A Multicentric Survey
Flacco, M. E., Manzoli, L., Bucci, M., Capasso, L., Comparcini, D., Simonetti, V., Gualano, M. R., Nocciolini, M., D’Amario, C., & Cicolini, G. (2015) · Journal of Clinical Hypertension · doi:10.1111/jch.12552 · Cited by 24
Parker, R. A., Paterson, M., Padfield, P. L., Pinnock, H., Hanley, J., Hammersley, V., Steventon, A., & McKinstry, B. (2018) · BMJ Open · doi:10.1136/bmjopen-2017-019431 · Cited by 21
Keating, S. E., Barnett, A., Croci, I., Hannigan, A., Elvin‐Walsh, L., Coombes, J. S., Campbell, K. L., Macdonald, G. A., & Hickman, I. J. (2020) · Archives of Rehabilitation Research and Clinical Translation · doi:10.1016/j.arrct.2020.100066 · Cited by 23
Stergiou, G. S., Christodoulakis, G. R., Nasothimiou, E. G., Giovas, P. P., & Kalogeropoulos, P. G. (2008) · American Journal of Hypertension · doi:10.1038/ajh.2008.176 · Cited by 21
Self-citationCandesartan Cilexetil Effectively Reduces Blood Pressure in Hypertensive Children
Franks, A. M., O’Brien, C. E., Stowe, C. D., Wells, T. G., & Gardner, S. F. (2008) · Annals of Pharmacotherapy · doi:10.1345/aph.1l212 · Cited by 21
Stergiou, G., Efstathiou, S., Roussias, L. G., & Mountokalakis, T. (2003) · Journal of Cardiovascular Pharmacology · doi:10.1097/00005344-200310000-00006 · Cited by 25
Self-citationImai, Y., Hosaka, M., Elnagar, N., & Satoh, M. (2013) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/1440-1681.12142 · Cited by 24
Nyklíček, I., & Vingerhoets, A. J. J. M. (2009) · International Journal of Behavioral Medicine · doi:10.1007/s12529-008-9019-z · Cited by 21
“Because of evidence that the kind of setting (home versus clinic) is more important than the number of measurements on separate days for clinical prognosis [19, 20], four consecutive blood pressure measurements were taken while participants were sitting in a quiet room in their homes, with two-minutes intervals betwee…”
BackgroundHome blood pressure monitoring in paediatric chronic hypertension
Furusawa, É. A., Filho, U. D., & Koch, V. H. K. (2009) · Journal of Human Hypertension · doi:10.1038/jhh.2008.167 · Cited by 20
Skirrow, C., Cashdollar, N. M., Granger, K. T., Jennings, S., Baker, E. K., Barnett, J. H., & Cormack, F. K. (2021) · Applied Neuropsychology Adult · doi:10.1080/23279095.2020.1860987 · Cited by 27
Ikeda, T., Gomi, T., Shibuya, Y., Shinozaki, S., Suzuki, Y., & MATSUDA, N. (2007) · Hypertension Research · doi:10.1291/hypres.30.1097 · Cited by 18
“Although it has been reported that home blood pressure monitoring has superior reproducibility compared to both office blood pressure measurement and ABPM, and can improve the accuracy of antihypertensive drug trials (33), it may be necessary to clarify in detail the time course of the effect of doxazosin by ABPM.”
BackgroundWeeks, D. L. (2007) · Evaluation & the Health Professions · doi:10.1177/0163278707304043 · Cited by 23
Self-Monitoring of Blood Pressure
Pickering, T. G. (2001) · Blood Pressure Monitoring in Cardiovascular Medicine and Therapeutics · doi:10.1007/978-1-59259-004-9_1 · Cited by 17
Zweiker, D., Lambert, T., Steinwender, C., Weber, T., Suppan, M., Brussee, H., Koppelstätter, C., Kerschbaum, J., Watschinger, B., Hohenstein-Scheibenecker, K., et al. (2016) · PLoS ONE · doi:10.1371/journal.pone.0161250 · Cited by 21
“Moreover, the most commonly used surrogate of effective RDN treatment is the change in office blood pressure, despite its limited prognostic value in individual patients compared to home [11] or ambulatory blood pressure (ABP) [12, 13].”
BackgroundResultThe predictive ability of blood pressure in elderly trial patients
Carr, M., Bao, Y., Pan, J., Cruickshank, K. J., & McNamee, R. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e3283568a73 · Cited by 19
Stergiou, G. S., Jaenecke, B., Giovas, P. P., Chang, A., Chung-Yueh, Y., & Tan, T.-M. (2007) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e32809efa38 · Cited by 20
Self-citationAutomedida da pressão arterial para o controle das cifras tensionais e para a adesão ao tratamento
Barroso, W. K. S., Jardim, P. C. B. V., Brito, L. P., Araújo, F. A., & Sousa, A. L. L. (2012) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x2012005000010 · Cited by 26
Shahin, M. H., Sá, A. C. C., Webb, A., Gong, Y., Langaee, T. Y., McDonough, C. W., Riva, A., Beitleshees, A. L., Chapman, A. B., Gums, J. G., et al. (2017) · Circulation Cardiovascular Genetics · doi:10.1161/circgenetics.116.001404 · Cited by 15
“Home DBP response was used for selection of participants for RNA-Seq analyses because it exhibits less variability and superior reproducibility compared with office BP response.(20) Of note, out of the 50 samples used for the RNA-Seq analysis in PEAR, 1 sample was removed because it did not pass quality control.”
Stergiou, G. S., Nasothimiou, E. G., & Roussias, L. G. (2010) · Journal of Hypertension · doi:10.1097/hjh.0b013e32833b497d · Cited by 16
Self-citationEguchi, K., Kuruvilla, S., Ishikawa, J., Ogedegbe, G. G., Gerin, W., Schwartz, J. E., & Pickering, T. G. (2011) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e328346d669 · Cited by 16
Mehanna, M., Gong, Y., McDonough, C. W., Beitelshees, A. L., Gums, J. G., Chapman, A. B., Schwartz, G. L., Johnson, J. A., Turner, S. T., & Cooper‐DeHoff, R. M. (2017) · Journal of Clinical Hypertension · doi:10.1111/jch.13094 · Cited by 15
Lambert, T., Blessberger, H., Gammer, V., Nahler, A., Grund, M., Kerschner, K., Buchmayr, G., Saleh, K., Kammler, J., & Steinwender, C. (2014) · Clinical Cardiology · doi:10.1002/clc.22269 · Cited by 14
Huangfu, W., Duan, P., Xiang, D., & Gao, R. (2015) · PubMed Central · Cited by 18
Uen, S., Fimmers, R., Brieger, M., Nickenig, G., & Mengden, T. (2009) · BMC Cardiovascular Disorders · doi:10.1186/1471-2261-9-20 · Cited by 14
“A recently published study of Stergiou demonstrated that the reproducibility was indeed even better with a newer validated upper-arm instrument with digital print-outs and standardized measurement than with a standardized 24-h ABPM [5].”
BackgroundMethodShimada, K., Kario, K., Kushiro, T., Teramukai, S., Ishikawa, Y., Kobayashi, F., & Saito, I. (2015) · Hypertension Research · doi:10.1038/hr.2015.88 · Cited by 14
A 5-year follow-up of ambulatory blood pressure in healthy older adults
Goldstein, I. (2003) · American Journal of Hypertension · doi:10.1016/s0895-7061(03)00906-3 · Cited by 13
Home Blood Pressure Monitoring: A Tool for Better Hypertension Control
Mancia, G., & Parati, G. (2010) · Hypertension · doi:10.1161/hypertensionaha.110.163188 · Cited by 17
“The average values derived from repeated home BP measurements are more reproducible than office BP [5, 6], are not affected by observer bias or end digit preference [7], and are devoid of a systematic error related to the presence of the white coat effect [8].”
BackgroundHer, A.-Y., Kim, Y. H., Rim, S.-J., Kim, J.-Y., Choi, E.-Y., Min, P.-K., Lee, B.-K., Hong, B.-K., & Kwon, H. M. (2014) · Anadolu Kardiyoloji Dergisi/The Anatolian Journal of Cardiology · doi:10.5152/akd.2014.5119 · Cited by 12
“Previous studies showed that ambulatory blood pressure (ABP) and home blood pressure (HBP) measurements are more reproducible than OBP measurements (5).”
BackgroundPragmatic Method Using Blood Pressure Diaries to Assess Blood Pressure Control
Sharman, J. E., Blizzard, C. L., Kosmala, W., & Nelson, M. R. (2016) · The Annals of Family Medicine · doi:10.1370/afm.1883 · Cited by 13
Blood pressure reduction after gastric bypass surgery is explained by a decrease in cardiac output
van Brussel, P. M., van den Bogaard, B., de Weijer, B. A., Truijen, J., Krediet, C. T. P., Janssen, I. M. C., van de Laar, A. W. J. M., Kaasjager, K. A. H., Fliers, E., LIESHOUT, J. J. V., et al. (2016) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00362.2016 · Cited by 13
“3 mmHg (35), resulting in a sample size of 9 patients using paired observations.”
BackgroundUtilidad de la monitorización ambulatoria de la presión arterial en la toma de decisiones clínicas
Sabater‐Hernández, D., Fikri-Benbrahim, O., & Faus, M. J. (2009) · Medicina Clínica · doi:10.1016/j.medcli.2009.07.019 · Cited by 22
Monte, M., Cambão, M., Bastos, J. M., & Polónia, J. J. (2015) · Revista Portuguesa de Cardiologia · doi:10.1016/j.repc.2015.05.005 · Cited by 13
Agreement comparison between home and clinic blood pressure measurements in 200 Chinese participants
Wang, W., Xie, J.-X., Liu, L., Ai, X.-H., Zhang, J., Sun, J.-Y., Wang, S.-Y., Shang, Z., Liu, L., Zhang, G. Q., et al. (2011) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e32834e3ba6 · Cited by 12
Natoli, A. P., & Rodriguez, C. M. (2024) · Discover Mental Health · doi:10.1007/s44192-024-00059-4 · Cited by 15
“One prospective solution to this issue involves averaging results from a repeated administration of the LPFS-qIAT at a single timepoint, a strategy often successfully used in research and clinical practice for other measures (e.g., blood pressure) [74].”
BackgroundScisney‐Matlock, M., Grand, A., Steigerwalt, S. P., & Normolle, D. P. (2009) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3283263064 · Cited by 12
Diagnostic tests: Home monitoring of blood pressure
McGrath, B. P. (2015) · Australian Prescriber · doi:10.18773/austprescr.2015.005 · Cited by 13
Clinical significance of home blood pressure and its possible practical application
Imai, Y. (2013) · Clinical and Experimental Nephrology · doi:10.1007/s10157-013-0831-7 · Cited by 13
“Home BP in the morning has been reported to more accurately reflect target organ damage than CBP in diabetic patients [103, 127, 157].”
BackgroundInfluentialPractical Aspects of Home and Ambulatory Blood Pressure Monitoring
Peixoto, A. J. (2015) · Methodist DeBakey Cardiovascular Journal · doi:10.14797/mdcj-11-4-214 · Cited by 15
Direct comparison of the reproducibility of in-office and self-measured home blood pressures
Asayama, K., Ohkubo, T., Rakugi, H., Miyakawa, M., Mori, H., Katsuya, T., Ikehara, Y., Ueda, S., Ohya, Y., Tsuchihashi, T., et al. (2021) · Journal of Hypertension · doi:10.1097/hjh.0000000000003026 · Cited by 10
“Although the present results are in partial agreement with the previous studies [4,7,29], they might not be generalizable to other populations.”
BackgroundResultA renoprotective effect of low dose losartan in patients with type 2 diabetes
Sawaki, H., Terasaki, J., Fujita, A., Nakagawa, S., Kanatsuna, N., Sadahiro, K., Isotani, H., Imagawa, A., & Hanafusa, T. (2007) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2007.08.004 · Cited by 10
“[20] G.”
MethodKhan, A., Mar, K. F., Schilling, J. P., & Brown, W. A. (2018) · PLoS ONE · doi:10.1371/journal.pone.0193043 · Cited by 15
Undetected, uncontrolled blood pressure in type 2 diabetes: self‐monitored blood pressure profiles
Mazze, R. S., Robinson, R., Simonson, G. D., Idrogo, M., Simpson, B. H., Kendall, D. M., & Bergenstal, R. M. (2004) · Blood Pressure · doi:10.1080/08037050410004774 · Cited by 12
Assessment of Nocturnal Blood Pressure: Importance of Determining the Time in Bed—A Pilot Study
Pilz, N., Heinz, V., Parati, G., Haberl, R., Hofmann, E., Küchler, G., Patzak, A. R., & Bothe, T. L. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13082170 · Cited by 10
“Ambulatory blood pressure monitoring (ABPM) is the gold-standard method for evaluating nocturnal BP, automatically capturing BP measurements at regular intervals over a 24 h period [8,9].”
MethodSatoh, M., Yoshida, T., Metoki, H., Murakami, T., Tatsumi, Y., Hirose, T., Takabatake, K., Tsubota‐Utsugi, M., Hara, A., Nomura, K., et al. (2023) · Scientific Reports · doi:10.1038/s41598-023-31861-9 · Cited by 14
How to best monitor blood pressure at home? Assessing numbers and individual patients
Stergiou, G. S., & Parati, G. (2010) · Journal of Hypertension · doi:10.1097/hjh.0b013e3283346e0b · Cited by 11
Self-citationO'Brien, E. T. (2011) · Hot Topics in Hypertension · doi:10.4147/hth-111207 · Cited by 14
Home blood pressure monitoring in clinical practice: how many measurements and when?
Padfield, P. L., & Parati, G. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e32826388e9 · Cited by 10
Terra, S. G., Blum, R. A., Wei, G. C. G., Lew, R., DIGENIO, A. G., Rajman, I., & Kazierad, D. J. (2004) · The Journal of Clinical Pharmacology · doi:10.1177/0091270004264167 · Cited by 9
“Some studies in hypertensive patients demonstrate that the initial blood pressure reading is highest secondary to an alert or nervous reaction,(8) and consequently, some investigators advocate dropping the first blood pressure measurement when calculating the mean blood pressure.(3,5,7) However, this same finding was…”
BackgroundResultStergiou, G. S., Roussias, L. G., & Mountokalakis, T. D. (2005) · Journal of Clinical Hypertension · doi:10.1111/j.1524-6175.2005.03859.x · Cited by 9
Self-citationHome or ambulatory blood pressure monitoring for the diagnosis of hypertension?
Stergiou, G. S., Omboni, S., & Parati, G. (2015) · Journal of Hypertension · doi:10.1097/hjh.0000000000000677 · Cited by 11
“First, the reproducibility of both HBP and ABP, although being clearly superior to that of office BP, is still imperfect, which means that some level of diagnostic disagreement would be expected even when the same BP monitoring method (HBP or ABP) is applied twice [13].”
MethodSelf-citationPalatini, P., Battista, F., Mos, L., Rattazzi, M., Ermolao, A., Vriz, O., Mazzer, A., & Saladini, F. (2024) · Journal of Hypertension · doi:10.1097/hjh.0000000000003874 · Cited by 9
Satoh, A., Arima, H., Hozawa, A., Ohkubo, T., Hisamatsu, T., Kadowaki, S., Kadota, A., Fujiyoshi, A., Miyagawa, N., Zaid, M., et al. (2019) · Journal of Hypertension · doi:10.1097/hjh.0000000000002080 · Cited by 8
“The stronger association of HBP with CVD appears to be attributable to lower measurement error and/or lower measurement bias [5].”
BackgroundGarnett, C. E., Johannesen, L., & McDowell, T. (2019) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt.1690 · Cited by 8
Chekka, L. M. S., Chapman, A. B., Gums, J. G., Cooper‐DeHoff, R. M., & Johnson, J. A. (2021) · The American Journal of Medicine · doi:10.1016/j.amjmed.2020.12.015 · Cited by 8
Thomopoulos, C., Andrikou, I., Konstantinidis, D., Iliakis, P., Kalos, T., Polyzos, D., Drogkaris, S., Siafi, E. P., Tousoulis, D. M., Stergiou, G. S., et al. (2021) · Journal of Hypertension · doi:10.1097/hjh.0000000000002887 · Cited by 9
“Thus, even if ambulatory BP monitoring has been performed twice, a within-phenotype classification disagreement would be expected in a considerable proportion of individuals [17,18].”
BackgroundSelf-citationKeehn, L., Hall, W. L., Berry, S. E., Sanders, T. A. B., Chowienczyk, P., & Floyd, C. N. (2022) · Journal of Hypertension · doi:10.1097/hjh.0000000000003290 · Cited by 9
Liu, T., Rao, H., Wang, M., Xu, H., Wang, W. J., Li, G., Wang, H., & Mu, L. (2021) · Scientific Reports · doi:10.1038/s41598-020-79282-2 · Cited by 8
Can NPs Rely on Self-Blood Pressure Measurements?
Artinian, N. T. (2004) · The Nurse Practitioner · doi:10.1097/00006205-200405000-00009 · Cited by 8
How to Cope With Unreliable Office Blood Pressure Measurement?
Stergiou, G. S. (2005) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.07.014 · Cited by 8
Self-citationHome (Self) Monitoring of Blood Pressure in Clinical Trials
Stergiou, G. S., & Ntineri, A. (2016) · Blood Pressure Monitoring in Cardiovascular Medicine and Therapeutics · doi:10.1007/978-3-319-22771-9_19 · Cited by 7
Self-citationMethodology and Applicability of Home Blood Pressure Monitoring in Children and Adolescents
Stergiou, G. S., & Ntineri, A. (2018) · Pediatric Hypertension · doi:10.1007/978-3-319-31107-4_45 · Cited by 7
Self-citation2022 Thai Hypertension Society guidelines on home blood pressure monitoring
Kunanon, S., Roubsanthisuk, W., Chattranukulchai, P., Sangwatanaroj, S., Ophascharoensuk, V., Sitthisook, S., & Sukonthasarn, A. (2022) · Journal of Clinical Hypertension · doi:10.1111/jch.14569 · Cited by 11
Beger, C., Rüegger, D., Lenz, A., Wagner, S., Haller, H., Schmidt-Ott, K. M., Volland, D., & Limbourg, F. P. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1115987 · Cited by 8
“Several studies have investigated how many measurement days are required to determine true BP (17, 20, 30).”
BackgroundLambert, T., Gammer, V., Nahler, A., Blessberger, H., Kammler, J., Grund, M., Kerschner, K., Buchmayr, G., Saleh, K., Kypta, A., et al. (2014) · International Journal of Cardiology · doi:10.1016/j.ijcard.2014.12.001 · Cited by 8
Kim, C. H., Kim, J. S., & Rhee, M. (2020) · Healthcare · doi:10.3390/healthcare8040457 · Cited by 7
Home Blood Pressure Monitoring And Nocturia In Adults
Lazar, J., Posner, A., Akbar, K., Tologonova, G., Monaghan, T. F., Murray, C., Weiss, J. P., Everaert, K., DeBacker, T., Helzner, E., et al. (2022) · Journal of Community Health · doi:10.1007/s10900-022-01171-8 · Cited by 7
Karotsis, A. K., Symeonidis, A. N., Mastorantonakis, S. E., Stergiou, G. S., & for the home-Di-plus study group (2006) · Clinical and Experimental Hypertension · doi:10.1080/10641960600946429 · Cited by 7
Self-citationHome Blood Pressure Monitoring: A Few minutes of Rest Before Measurement May Not Be Appropriate
Boivin, J., Boutte, E., Fay, R., Rossignol, P., & Zannad, F. M. (2014) · American Journal of Hypertension · doi:10.1093/ajh/hpu001 · Cited by 9
Monte, M., Cambão, M., Bastos, J. M., & Polónia, J. J. (2015) · Revista Portuguesa de Cardiologia (English Edition) · doi:10.1016/j.repce.2015.10.001 · Cited by 7
Loaned self-measurement equipment model compared with ambulatory blood pressure monitoring
Vargas, C. G. C., Rios, V. P., & Troyo‐Sanromán, R. (2003) · Blood Pressure Monitoring · doi:10.1097/00126097-200304000-00002 · Cited by 8
Kawabe, H., & Saito, I. (2008) · Clinical and Experimental Hypertension · doi:10.1080/10641960701815911 · Cited by 8
“Furthermore, a recent study shows that home BP seems to have superior reproducibility compared with both casual BP and ambulatory BP (11).”
BackgroundStergiou, G. S., Zourbaki, A. S., Efstathiou, S. P., Stathopoulos, G. P., Keramopoulos, A., & Mountokalakis, T. D. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(02)02951-5 · Cited by 6
Self-citationNiessen, M. A. J., van der Hoeven, N. V., van den Born, B. H., van Kalken, C. K., & Kraaijenhagen, R. A. (2013) · European Journal of Public Health · doi:10.1093/eurpub/ckt144 · Cited by 10
Improving Blood Pressure Management and Control With Out-of-Office Blood Pressure Monitoring
Nugent, J. T., Binka, E., & Brady, T. M. (2025) · American Journal of Hypertension · doi:10.1093/ajh/hpaf222 · Cited by 6
Gazzola, K., Cammenga, M., van der Hoeven, N. V., van Montfrans, G. A., & van den Born, B. H. (2017) · Journal of Human Hypertension · doi:10.1038/jhh.2017.27 · Cited by 5
Tzamouranis, D., Alexopoulou, A. A., Dourakis, S. P., & Stergiou, G. S. (2010) · BMC Gastroenterology · doi:10.1186/1471-230x-10-143 · Cited by 7
“Even if 24-hour ABP is proved accurate and valuable in hypertensive patients [18-25], its usefulness in the population of cirrhotic patients is therefore not well documented.”
BackgroundSelf-citationGriep, L. M. O., Frost, G. S., Holmes, E. C., Wareham, N. J., & Elliott, P. (2024) · Nutrients · doi:10.3390/nu16172923 · Cited by 5
“We also invited a subset of participants to wear a 24 h ABPM device to provide multiple and more reproducible BP readings throughout the day in the usual environment of the participant [48].”
MethodArtinian, N. T., Goff, D. C., Pickering, T. G., Miller, N. H., & Ogedegbe, G. G. (2008) · Cited by 4
Monitoring of Treatment for Arterial Hypertension
Mengden, T., & Weisser, B. (2021) · Deutsches Ärzteblatt international · doi:10.3238/arztebl.m2021.0158 · Cited by 17
Home Monitoring of Blood Pressure
Stergiou, G. S., & Κόλλιας, Α. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-42973-3.00010-x · Cited by 3
Self-citationFactors Affecting Home Health Monitoring in a 1-Year On-Going Monitoring Study in Osaka
TAMURA, T., Mizukura, I., & Kimura, Y. (2010) · Communications in medical and care compunetics · doi:10.1007/8754_2010_9 · Cited by 3
Metadata
- Authors
- Stergiou, G. S., Baibas, N. M., Gantzarou, A. P., Skeva, I. I., Kalkana, C. B., Roussias, L. G., & Mountokalakis, T. D.
- Affiliations
- Sotiria General Hospital (GR)
- Corresponding author
- Stergiou, G. S.
- ORCID
- Stergiou, G. S.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 2002-02-01
- Volume
- 15
- Issue
- 2
- Pages
- 101-104
- ISSN
- 0895-7061 (ISSN-L)
- 1941-7225
- OpenAlex
- W2101549027
- Semantic Scholar
- fd59daf9b2e546a8f9a47788ac3613a683fb083c
- Cited by
- 268
- References
- 17
- Citations by year
- 2026: 5 · 2025: 3 · 2024: 11 · 2023: 9 · 2022: 13 · 2021: 12 · 2020: 8 · 2019: 11 · 2018: 13 · 2017: 10 · 2016: 9 · 2015: 15 · 2014: 13 · 2013: 10 · 2012: 13
- FWCI
- 7.42
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Hypertension (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Clinical Trials
- Keywords
- home blood pressure monitoring, ambulatory blood pressure monitoring, office blood pressure, antihypertensive drug trials, sample size determination, measurement variability, hypertension
- MeSH terms
- Adult, Antihypertensive Agents, Blood Pressure Determination, Clinical Trials as Topic, Female, Home Care Services, Humans, Hypertension, Male, Middle Aged, Office Visits, Research Design, Reproducibility of Results, Blood Pressure Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.