Reproducibility of home, ambulatory, and clinic blood pressure: implications for the design of trials for the assessment of antihypertensive drug efficacy
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Background The aims of this study were to compare the reproducibility of blood pressure (BP) measured in the clinic (CBP), at home (HBP), and by ambulatory monitoring (ABP), and to assess its implications on the accuracy of antihypertensive drug trials. Methods A total of 133 untreated subjects with elevated CBP were assessed with repeated measurements of CBP (five visits within 3 months), HBP (6 workdays within 2 weeks), and ABP (twice, 2 weeks apart). The reproducibility of CBP (one visit), HBP (2 days), and ABP (24 h) was quantified using the SD of differences (SDD) between repeated measurements. The number of subjects required in a comparative trial of two drugs was calculated for each measurement method. Results We found that HBP provided the lowest SDD values (6.9/4.7 mm Hg, systolic/diastolic, compared with 8.3/5.6 for ABP and 11.0/6.6 for CBP). For a parallel trial aiming to detect a difference in the effect of two drugs of 10 mm Hg systolic BP, 51 subjects would be required when using CBP compared with 29 using ABP and 20 using HBP (73, 53 and 37 subjects, respectively, for the detection of a 5 mm Hg difference in diastolic BP). Conclusions The study shows that HBP seems to have superior reproducibility compared with both CBP and ABP. In addition, HBP can improve the accuracy of antihypertensive drug trials, thereby reducing the sample size required.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“BP readings obtained using traditional methods show only moderate reproducibility, with out-of-office BP measurements being more reproducible than those taken in the office63.”
From Blood pressure and its variability: classic and novel measurement techniques (2022) · cites this paper as [63]
In the citing paper
“The reproducibility of any BP measurement method improves by increasing the number of BP readings”
In the citing paper
“one of the advantages of HBPM is the larger number of readings that can be obtained compared with office BP (OBP) measurement [17,18].”
In the citing paper
“Cross-sectional studies have mainly focused on the effect of different numbers of readings and days on average HBP, HBP variability and reproducibility; cross-classification according to office and home BP (normotension, white-coat, masked and sustained hypertension); association with ABPM values and association with indices of preclinical target-organ damage [17,18,127–133]”
In the citing paper
“During the last two decades, HBPM has been used increasingly in clinical hypertension research [17,155,267–273].”
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The reproducibility of average ambulatory, home, and clinic pressures.
James, G. D., Pickering, T. G., Yee, L. S., Harshfield, G. A., Riva, S., & Laragh, J. H. (1988) · Hypertension · doi:10.1161/01.hyp.11.6.545 · Cited by 249
Asmar, R., & Zanchetti, A. (2000) · Journal of Hypertension · doi:10.1097/00004872-200018050-00001 · Cited by 213
Self-monitoring of blood pressure at home: how many measurements are needed?
Stergiou, G. S., Skeva, I. I., Zourbaki, A. S., & Mountokalakis, T. D. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816060-00002 · Cited by 212
Self-citationTrazzi, S., Mutti, E., Frattola, A., Imholz, B., Parati, G., & Mancia, G. (1991) · Journal of Hypertension · doi:10.1097/00004872-199102000-00003 · Cited by 158
Stergiou, G. S., Zourbaki, A. S., Skeva, I. I., & Mountokalakis, T. D. (1998) · American Journal of Hypertension · doi:10.1016/s0895-7061(98)00038-7 · Cited by 132
Self-citationStergiou, G. S., Skeva, I. I., Baibas, N. M., Kalkana, C. B., Roussias, L. G., & Mountokalakis, T. D. (2000) · Journal of Hypertension · doi:10.1097/00004872-200018120-00007 · Cited by 128
Self-citationReproducibility of Home Blood Pressure Measurements Over a 1-Year Period
Sakuma, M. (1997) · American Journal of Hypertension · doi:10.1016/s0895-7061(97)00117-9 · Cited by 121
Coats, A. J. S., Radaelli, A., Clark, S. J., Conway, J., & Sleight, P. (1992) · Journal of Hypertension · doi:10.1097/00004872-199204000-00011 · Cited by 96
Feasibility Study of N-of-1 Trials With Blood Pressure Self-Monitoring in Hypertension
Chatellier, G., Day, M., Bobrie, G., & Menard, J. (1995) · Hypertension · doi:10.1161/01.hyp.25.2.294 · Cited by 72
Vaur, L., Dubroca, I., Dutrey-Dupagne, C., Genes, N., Châtellier, G., Bouvier-d'Yvoire, M., Elkik, F., & Ménard (1998) · PubMed · Cited by 70
Mengden, T., Battig, B., & Vetter, W. (1991) · Journal of Hypertension · doi:10.1097/00004872-199112000-00152 · Cited by 45
Groppelli, A., Omboni, S., Ravogli, A., Villani, A., Parati, G., & Mancia, G. (1991) · Journal of Hypertension · doi:10.1097/00004872-199112000-00151 · Cited by 36
Brueren, M. (1997) · American Journal of Hypertension · doi:10.1016/s0895-7061(97)00125-8 · Cited by 35
Sample size for short‐term trials of antihypertensive drugs.
Freestone, S. H., Silas, J., & Ramsay, L. (1982) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.1982.tb01971.x · Cited by 25
Stergiou, G. S. (2000) · American Journal of Hypertension · doi:10.1016/s0895-7061(00)00725-1 · Cited by 24
Self-citation(1960) · Anesthesiology · doi:10.1097/00000542-196001000-00075 · Cited by 23
Reeves, R. A., Leenen, F. H. H., & Joyner, C. D. (1992) · Journal of Hypertension · doi:10.1097/00004872-199210000-00020 · Cited by 20
Research works printed but not linked: 3
- 1988, Hypertension, 1, 545
- 1995, ARCH MAL COEUR, 88, 1165
- 1998, Blood pressure monitoring, 3, 19
Cited by
Mancia, G., Kreutz, R., Brunström, M., Burnier, M., Grassi, G., Januszewicz, A., Muiesan, M. L., Tsioufis, K., Agabiti-Rosei, E., Algharably, E. A. E., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003480 · Cited by 3,473
Self-citationMeasurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
Parati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Self-citationKandzari, D. E., Böhm, M., Mahfoud, F., Townsend, R. R., Weber, M. A., Pocock, S., Tsioufis, K., Tousoulis, D., Choi, J. W., East, C., et al. (2018) · The Lancet · doi:10.1016/s0140-6736(18)30951-6 · Cited by 793
Pickering, T. G., Miller, N. H., Ogedegbe, G., Krakoff, L. R., Artinian, N. T., & Goff, D. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.189010 · Cited by 668
Metadata
- Authors
- Stergiou, G. S., Baibas, N. M., Gantzarou, A. P., Skeva, I. I., Kalkana, C. B., Roussias, L. G., & Mountokalakis, T. D.
- Affiliations
- Sotiria General Hospital (GR)
- Corresponding author
- Stergiou, G. S.
- ORCID
- Stergiou, G. S.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 2002-02-01
- Volume
- 15
- Issue
- 2
- Pages
- 101-104
- ISSN
- 0895-7061 (ISSN-L)
- 1941-7225
- OpenAlex
- W2101549027
- Semantic Scholar
- fd59daf9b2e546a8f9a47788ac3613a683fb083c
- Cited by
- 268
- References
- 17
- Citations by year
- 2026: 5 · 2025: 3 · 2024: 11 · 2023: 9 · 2022: 13 · 2021: 12 · 2020: 8 · 2019: 11 · 2018: 13 · 2017: 10 · 2016: 9 · 2015: 15 · 2014: 13 · 2013: 10 · 2012: 13
- FWCI
- 7.42
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Hypertension (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Clinical Trials
- Keywords
- home blood pressure monitoring, ambulatory blood pressure monitoring, office blood pressure, antihypertensive drug trials, sample size determination, measurement variability, hypertension
- MeSH terms
- Adult, Antihypertensive Agents, Blood Pressure Determination, Clinical Trials as Topic, Female, Home Care Services, Humans, Hypertension, Male, Middle Aged, Office Visits, Research Design, Reproducibility of Results, Blood Pressure Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.