Tissue engineering of small caliber vascular grafts
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Previous tissue engineering approaches to create small caliber vascular grafts have been limited by the structural and mechanical immaturity of the constructs. This study uses a novel in vitro pulse duplicator system providing a 'biomimetic' environment during tissue formation to yield more mature, implantable vascular grafts. METHODS: Vascular grafts (I.D. 0.5 cm) were fabricated from novel bioabsorbable polymers (polyglycolic-acid/poly-4-hydroxybutyrate) and sequentially seeded with ovine vascular myofibroblasts and endothelial cells. After 4 days static culture, the grafts (n=24) were grown in vitro in a pulse duplicator system (bioreactor) for 4, 7, 14, 21, and 28 days. Controls (n=24) were grown in static culture conditions. Analysis of the neo-tissue included histology, scanning electron microscopy (SEM), and biochemical assays (DNA for cell content, 5-hydroxyproline for collagen). Mechanical testing was performed measuring the burst pressure and the suture retention strength. RESULTS: Histology showed viable, dense tissue in all samples. SEM demonstrated confluent smooth inner surfaces of the grafts exposed to pulsatile flow after 14 days. Biochemical analysis revealed a continuous increase of cell mass and collagen to 21 days compared to significantly lower values in the static controls. The mechanical properties of the pulsed vascular grafts comprised supra-physiological burst strength and suture retention strength appropriate for surgical implantation. CONCLUSIONS: This study demonstrates the feasibility of tissue engineering of viable, surgically implantable small caliber vascular grafts and the important effect of a 'biomimetic' in vitro environment on tissue maturation and extracellular matrix formation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Functional Arteries Grown in Vitro
Niklason, L. E., Gao, J., Abbott, W. M., Hirschi, K. K., Houser, S., Marini, R., & Langer, R. (1999) · Science · doi:10.1126/science.284.5413.489 · Cited by 1,766
Two Improved and Simplified Methods for the Spectrophotometric Determination of Hydroxyproline.
Bergman, I., & Loxley, R. (1963) · Analytical Chemistry · doi:10.1021/ac60205a053 · Cited by 1,525
A completely biological tissue-engineered human blood vessel
L'heureux, N., Pâquet, S., Labbé, R., Germain, L., & Auger, F. A. (1998) · The FASEB Journal · doi:10.1096/fasebj.12.1.47 · Cited by 1,402
Vacanti, J. P., & Langer, R. (1999) · The Lancet · doi:10.1016/s0140-6736(99)90247-7 · Cited by 1,323
A Blood Vessel Model Constructed from Collagen and Cultured Vascular Cells
Weinberg, C. B., & Bell, E. (1986) · Science · doi:10.1126/science.2934816 · Cited by 1,240
THE USE OF TUBES CONSTRUCTED FROM VINYON “N” CLOTH IN BRIDGING ARTERIAL DEFECTS A PRELIMINARY REPORT
Voorhees, A. B., Jaretzki, A., & Blakemore, A. H. (1952) · Annals of Surgery · doi:10.1097/00000658-195203000-00006 · Cited by 569
In vitro construction of a human blood vessel from cultured vascular cells: A morphologic study
L'Heureux, N., Germain, L., Labbé, R., & Auger, F. A. (1993) · Journal of Vascular Surgery · doi:10.1016/0741-5214(93)90150-k · Cited by 337
A thirty-year survey of the reconstructive surgical treatment of aortoiliac occlusive disease
Szilagyi, D. E., Elliott, J. P., Smith, R. F., Reddy, D. J., & McPharlin, M. (1986) · Journal of Vascular Surgery · doi:10.1016/0741-5214(86)90104-7 · Cited by 312
Long-term results of femorotibial bypass with vein or polytetrafluoroethylene
Sayers, R. D., Raptis, S., Berce, M., & Miller, J. H. (1998) · Journal of British Surgery · doi:10.1046/j.1365-2168.1998.00765.x · Cited by 194
Cited by
Bishop, E. S., Mostafa, S., Pakvasa, M., Luu, H. H., Lee, M. J., Wolf, J. M., Ameer, G. A., He, T.-C., & Reid, R. R. (2017) · Genes & Diseases · doi:10.1016/j.gendis.2017.10.002 · Cited by 683
Medical applications of poly-4-hydroxybutyrate: A strong flexible absorbable biomaterial
Martin, D. P., & Williams, S. F. (2003) · Biochemical Engineering Journal · doi:10.1016/s1369-703x(03)00040-8 · Cited by 510
Medical applications of membranes: Drug delivery, artificial organs and tissue engineering
Stamatialis, D. F., Papenburg, B. J., Gironés, M., Saiful, S., Bettahalli, S. N. M., Schmitmeier, S., & Wessling, M. (2008) · Journal of Membrane Science · doi:10.1016/j.memsci.2007.09.059 · Cited by 473
“mall diameter tissue-engineered vascular grafts are grown sing the pulsatile flow of the nutrient media which is geneated by periodical expansion of a highly elastic membrane, dend inflated by an air pump [304].”
BackgroundSmall-Diameter Artificial Arteries Engineered In Vitro
Isenberg, B. C., Williams, C., & Tranquillo, R. T. (2006) · Circulation Research · doi:10.1161/01.res.0000196867.12470.84 · Cited by 469
Vaz, C. M., van Tuijl, S., Bouten, C. V. C., & Baaijens, F. P. T. (2005) · Acta Biomaterialia · doi:10.1016/j.actbio.2005.06.006 · Cited by 459
Decellularized vein as a potential scaffold for vascular tissue engineering
Schaner, P. J., Martin, N. D., Tulenko, T. N., Shapiro, I. M., Tarola, N. A., Leichter, R. F., Carabasi, R. A., & DiMuzio, P. J. (2004) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2004.03.033 · Cited by 339
Elastin biosynthesis: The missing link in tissue-engineered blood vessels
PATEL, A., FINE, B., SANDIG, M., & MEQUANINT, K. (2006) · Cardiovascular Research · doi:10.1016/j.cardiores.2006.02.021 · Cited by 328
Artificial blood vessel: The Holy Grail of peripheral vascular surgery
Kakisis, J. D., Liapis, C. D., Breuer, C., & Sumpio, B. E. (2005) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2004.12.026 · Cited by 310
The Mechanical Properties of Infrainguinal Vascular Bypass Grafts: Their Role in Influencing Patency
Sarkar, S., Salacinski, H. J., Hamilton, G., & Seifalian, A. M. (2006) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2006.01.006 · Cited by 301
L'Heureux, N., Dusserre, N., Marini, A., Garrido, S., de la Fuente, L., & McAllister, T. (2007) · Nature Clinical Practice Cardiovascular Medicine · doi:10.1038/ncpcardio0930 · Cited by 292
Silk-based electrospun tubular scaffolds for tissue-engineered vascular grafts
Soffer, L., Wang, X., Zhang, X., Kluge, J., Dorfmann, L., Kaplan, D. L., & Leisk, G. (2008) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856208784089607 · Cited by 278
Bioreactors for tissue engineering
Chen, H.-C., & Hu, Y.-C. (2006) · Biotechnology Letters · doi:10.1007/s10529-006-9111-x · Cited by 256
Syedain, Z. H., Meier, L. A., Bjork, J. W., Lee, A., & Tranquillo, R. T. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.09.019 · Cited by 254
Guan, J., Sacks, M. S., Beckman, E. J., & Wagner, W. R. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00476-9 · Cited by 250
Implanted cardiovascular polymers: Natural, synthetic and bio-inspired
Venkatraman, S., Boey, F., & Lao, L. L. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.07.001 · Cited by 246
Tissue Engineering of Functional Trileaflet Heart Valves From Human Marrow Stromal Cells
Hoerstrup, S. P., Kadner, A., Melnitchouk, S., Trojan, A., Eid, K., Tracy, J., Sodian, R., Visjager, J. F., Kolb, S. A., Grunenfelder, J., et al. (2002) · Circulation · doi:10.1161/01.cir.0000032872.55215.05 · Cited by 240
Self-citationSmall-Diameter Blood Vessels Engineered With Bone Marrow–Derived Cells
Cho, S.-W., Lim, S. H., Kim, I.-K., Hong, Y. S., Kim, S.-S., Yoo, K. J., Park, H.-Y., Jang, Y., Chang, B. C., Choi, C. Y., et al. (2005) · Annals of Surgery · doi:10.1097/01.sla.0000154268.12239.ed · Cited by 239
“Suture Retention Strength Measurement The suture retention strength of the vascular grafts was measured using an Instron mechanical tester (Instron 4465; Instron, Canton, MA) as previously described.(26) One end of the specimen was fixed by stage clamp of Instron tester, and the other end was connected to another clam…”
BackgroundMethodEngineering thick tissues - the vascularisation problem
Graduate School of Biomedical Engineering, U. O. N. S. W., Ko, H., Milthorpe, B., & McFarland, C. (2007) · European Cells and Materials · doi:10.22203/ecm.v014a01 · Cited by 238
“…mechanical stimulation regimes, such as cyclical radial distension and/or shear stress, in bioreactors (Braddon et al., 2002; Chappell et al., 1998; Hoerstrup et al., 2001; Imberti et al., 2002; Nerem et al., 1998; Thomas et al., 2002; Ziegler et al., 1995), as well as the use of various…”
BackgroundIn Jeong, S., Kim, S. Y., Cho, S. K., Chong, M. S., Kim, K. S., Kim, H., Lee, S. B., & Lee, Y. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.10.025 · Cited by 238
In vitro study of directly bioprinted perfusable vasculature conduits
Zhang, Y., Yu, Y., Akkouch, A., Dababneh, A., Dolati, F., & Ozbolat, I. T. (2015) · Biomaterials Science · doi:10.1039/c4bm00234b · Cited by 226
Whitley, G. S. J., & Cartwright, J. E. (2010) · Placenta · doi:10.1016/j.placenta.2010.03.002 · Cited by 211
“cells of the vessel wall: for instance EC modulate VSMC phenotype which affects matrix deposition [126] whereas VSMC can influence the EC response to shear stress [127,128].”
BackgroundFabrication of cell microintegrated blood vessel constructs through electrohydrodynamic atomization
Stankus, J. J., Soletti, L., Fujimoto, K., Hong, Y., Vorp, D. A., & Wagner, W. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.02.012 · Cited by 198
Kelm, J. M., Lorber, V., Snedeker, J. G., Schmidt, D., Broggini-Tenzer, A., Weisstanner, M., Odermatt, B., Mol, A., Zünd, G., & Hoerstrup, S. P. (2010) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2010.03.002 · Cited by 191
Self-citationBioreactors for Cardiovascular Cell and Tissue Growth: A Review
Barron, V., Lyons, E., Stenson-Cox, C., McHugh, P. E., & Pandit, A. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1603260 · Cited by 182
Wang, C., Cen, L., Yin, S., Liu, Q., Liu, W., Cao, Y., & Cui, L. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.09.086 · Cited by 172
Wang, D., Xu, Y., Li, Q., & Turng, L.-S. (2020) · Journal of Materials Chemistry B · doi:10.1039/c9tb01849b · Cited by 171
Bioreactors for Tissue Engineering: Focus on Mechanical Constraints. A Comparative Review
Bilodeau, K., & Mantovani, D. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.2367 · Cited by 170
“The artery-like tissue obtained had a burst strength of approximately 2000 mm Hg. Hoerstrup et al. 4 designed and used a pulsed perfusion bioreactor specific to small vessel culture.”
Chung, S., Ingle, N. P., Montero, G. A., Kim, S. H., & King, M. W. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.12.007 · Cited by 165
“On the other hand, implantation of native vessels is limited by themismatch of dimensional and mechanical properties [2,6].”
BackgroundVascular tissue engineering: from in vitro to in situ
Li, S., Sengupta, D., & Chien, S. (2014) · WIREs Systems Biology and Medicine · doi:10.1002/wsbm.1246 · Cited by 164
Stekelenburg, M., Rutten, M. C. M., Snoeckx, L. H. E. H., & Baaijens, F. P. T. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0183 · Cited by 164
“have already used the combination of PGA and P4HB in vascular tissue engineering.(11) These investigators did not use fibrin gel, and the constructs were seeded with ovine cells.”
Living, autologous pulmonary artery conduits tissue engineered from human umbilical cord cells
Hoerstrup, S. P., Kadner, A., Breymann, C., Maurus, C. F., Guenter, C. I., Sodian, R., Visjager, J. F., Zund, G., & Turina, M. I. (2002) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(02)03649-4 · Cited by 164
“In previous studies, based on peripheral vascular cells, we and others have shown that pulsatile flow in vitro conditioning enhanced autologous matrix formation, therefore allowing the use of more rapidly bioabsorbable scaffold materials [7, 16].”
BackgroundMethodSelf-citationFlanagan, T. C., Sachweh, J. S., Frese, J., Schnöring, H., Gronloh, N., Koch, S., Tolba, R. H., Schmitz-Rode, T., & Jockenhoevel, S. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2009.0018 · Cited by 160
“These structures contained a slowly degrading, biodegradable supporting polylactide material (poly(L=D)lactide 96=4), with burst pressures comparing more favorably with others reported using alternative cell-seeded scaffold materials, including a collagen gel=polyethylene terephthalate (PET) composite (with two non-de…”
Dynamic culture conditions to generate silk-based tissue-engineered vascular grafts
Zhang, X., Wang, X., Keshav, V., Wang, X., Johanas, J. T., Leisk, G. G., & Kaplan, D. L. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.02.002 · Cited by 160
“Biodegradable synthetic materials have been widely studied because of their relative ease in processing and controllable mechanical properties [14,15], including polylactic acid (PLA)- or polyglycolic acid (PGA)-based scaffolds [14,16–19].”
Deeken, C. R., & Matthews, B. D. (2013) · ISRN Surgery · doi:10.1155/2013/238067 · Cited by 139
Metadata
- Authors
- Hoerstrup, S.
- Venue
- European Journal of Cardio-Thoracic Surgery
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-07
- Volume
- 20
- Issue
- 1
- Pages
- 164-169
- ISSN
- 1010-7940 (ISSN-L)
- OpenAlex
- W2141480483
- Cited by
- 281
- References
- 17
- FWCI
- 9.32
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.