External accumulation of ions for enhanced electrospray ionization fourier transform ion cyclotron resonance mass spectrometry
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Electrospray ionization (ESI) in combination with Fourier transform ion cyclotron resonance (FTICR) mass spectrometry provides for mass analysis of biological molecules with unrivaled mass accuracy, resolving power and sensitivity. However, ESI FTICR MS performance with on-line separation techniques such as liquid chromatography (LC) and capillary electrophoresis has to date been limited primarily by pulsed gas assisted accumulation and the incompatibility of the associated pump-down time with the frequent ion beam sampling requirement of on-line chromatographic separation. Here we describe numerous analytical advantages that accrue by trapping ions at high pressure in the first rf-only octupole of a dual octupole ion injection system before ion transfer to the ion trap in the center of the magnet for high performance mass analysis at low pressure. The new configuration improves the duty cycle for analysis of continuously generated ions, and is thus ideally suited for on-line chromatographic applications. LC/ESI FTICR MS is demonstrated on a mixture of 500 fmol of each of three peptides. Additional improvements include a fivefold increase in signal-to-noise ratio and resolving power compared to prior methods on our instrument.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray ionization–principles and practice
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1990) · Mass Spectrometry Reviews · doi:10.1002/mas.1280090103 · Cited by 1,569
Tailored excitation for Fourier transform ion cyclotron mass spectrometry
Marshall, A. G., Wang, T. C. L., & Ricca, T. L. (1985) · Journal of the American Chemical Society · doi:10.1021/ja00312a015 · Cited by 631
Self-citationSmith, R. D., Loo, J. A., Loo, R. R. O., Busman, M., & Udseth, H. R. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100504 · Cited by 569
Micro-electrospray mass spectrometry: Ultra-high-sensitivity analysis of peptides and proteins
Emmett, M. R., & Caprioli, R. M. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)85001-1 · Cited by 510
Self-citationCovey, T. R., Huang, E. C., & Henion, J. D. (1991) · Analytical Chemistry · doi:10.1021/ac00013a003 · Cited by 446
Attomole Protein Characterization by Capillary Electrophoresis-Mass Spectrometry
Valaskovic, G. A., Kelleher, N. L., & McLafferty, F. W. (1996) · Science · doi:10.1126/science.273.5279.1199 · Cited by 398
An electrospray‐ionization mass spectrometer with new features
Chowdhury, S. K., Katta, V., & Chait, B. T. (1990) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290040305 · Cited by 323
High-resolution electrospray mass spectra of large molecules
Henry, K. D., Quinn, J. P., & McLafferty, F. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00014a043 · Cited by 309
Collisional Activation of Large Multiply Charged Ions Using Fourier Transform Mass Spectrometry
Senko, M. W., Speir, J. P., & McLafferty, F. W. (1994) · Analytical Chemistry · doi:10.1021/ac00090a003 · Cited by 263
Self-citationFourier-transform mass spectrometry of large molecules by electrospray ionization.
Henry, K. D., Williams, E. R., Wang, B. H., McLafferty, F. W., Shabanowitz, J., & Hunt, D. F. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.23.9075 · Cited by 215
Electrospray Ionization Fourier Transform Ion Cyclotron Resonance at 9.4 T
Senko, M. W., Hendrickson, C. L., Paša-Tolić, L., Marto, J. A., White, F. M., Guan, S., & Marshall, A. G. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(199611)10:14<1824::aid-rcm695>3.0.co;2-e · Cited by 212
Self-citationHigh-resolution tandem FT mass spectrometry above 10 kDa
McLafferty, F. W. (1994) · Accounts of Chemical Research · doi:10.1021/ar00047a009 · Cited by 194
Fourier transform ion cyclotron resonance mass spectrometry: technique developments
Marshall, A. G., & Schweikhard, L. (1992) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(92)85058-8 · Cited by 170
Self-citationBeu, S. C., Senko, M. W., Quinn, J. P., Wampler, F. M., & McLafferty, F. W. (1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)85017-r · Cited by 157
Self-citationSchweikhard, L., Guan, S., & Marshall, A. G. (1992) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(92)80053-4 · Cited by 155
Self-citationHofstadler, S. A., Severs, J. C., Smith, R. D., Swanek, F. D., & Ewing, A. G. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19960610)10:8<919::aid-rcm597>3.0.co;2-8 · Cited by 137
Online Time-of-Flight Mass Spectrometric Analysis of Peptides Separated by Capillary Electrophoresis
Fang, L., Zhang, R., Williams, E. R., & Zare, R. N. (1994) · Analytical Chemistry · doi:10.1021/ac00093a025 · Cited by 129
Unit resolution mass spectra of 112 kDa molecules with 3 Da accuracy
Kelleher, N. L., Senko, M. W., Siegel, M. M., & McLafferty, F. W. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00060-3 · Cited by 122
Self-citationMitchell, D. W., & Smith, R. D. (1995) · Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics · doi:10.1103/physreve.52.4366 · Cited by 115
Guan, S., Kim, H. S., Marshall, A. G., Wahl, M. C., Wood, T. D., & Xiang, X. (1994) · Chemical Reviews · doi:10.1021/cr00032a001 · Cited by 111
Self-citationEmmett, M. R., Andrén, P. E., & Caprioli, R. M. (1995) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00070-4 · Cited by 94
Self-citationHigh‐resolution tandem mass spectra of 37‐67 kDa proteins
Speir, J. P., Senko, M. W., Little, D. P., Loo, J. A., & McLafferty, F. W. (1995) · Journal of Mass Spectrometry · doi:10.1002/jms.1190300108 · Cited by 86
Self-citationImproved fourier-transform ion-cyclotron-resonance mass spectrometry of large biomolecules
Beu, S. C., Senko, M. W., Quinn, J. P., & McLafferty, F. W. (1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)85077-b · Cited by 84
Self-citationOn-line capillary electrophoresis with Fourier transform ion cyclotron resonance mass spectrometry
Hofstadler, S. A., Wahl, J. H., Bruce, J. E., & Smith, R. D. (1993) · Journal of the American Chemical Society · doi:10.1021/ja00068a070 · Cited by 72
External-ion accumulation in a Penning trap with quadrupole excitation assisted buffer gas cooling
Hasse, H., Becker, S., Dietrich, G., Klisch, N., Kluge, H. ‐., Lindinger, M. I., Lützenkirchen, K., Schweikhard, L., & Ziegler, J. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(93)03924-b · Cited by 68
Yao, J., Dey, M., Pastor, S. J., & Wilkins, C. L. (1995) · Analytical Chemistry · doi:10.1021/ac00116a004 · Cited by 34
Linear excitation and detection in Fourier transform ion cyclotron resonance mass spectrometry
Grosshans, P. B., Chen, R., Limbach, P. A., & Marshall, A. G. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)90034-5 · Cited by 32
Self-citationStacey, C. C., Kruppa, G. H., Watson, C. H., Wronka, J., Laukien, F. H., Banks, J. F., Whitehouse, C. M., & Voyksner, R. D. (1994) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290080704 · Cited by 31
Radial ion transport due to resistive-wall destabilization in Fourier transform mass spectrometry
Beu, S. C., & Laude, D. A. (1991) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(91)85038-n · Cited by 26
Quadrupolar Axialization for Improved Control of Electrosprayed Proteins in FTICR Mass Spectrometry
Hendrickson, C. L., & Laude, D. A. (1995) · Analytical Chemistry · doi:10.1021/ac00106a011 · Cited by 22
Self-citation
Cited by
Mass Spectrometry and Protein Analysis
Domon, B., & Aebersold, R. (2006) · Science · doi:10.1126/science.1124619 · Cited by 2,181
Fourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1<1::aid-mas1>3.0.co;2-k · Cited by 1,990
Self-citationKim, S., Kramer, R. W., & Hatcher, P. G. (2003) · Analytical Chemistry · doi:10.1021/ac034415p · Cited by 1,336
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
Hughey, C. A., Hendrickson, C. L., Rodgers, R. P., Marshall, A. G., & Qian, K. (2001) · Analytical Chemistry · doi:10.1021/ac010560w · Cited by 851
Self-citation
Metadata
- Authors
- Senko, M. W., Hendrickson, C. L., Emmett, M. R., Shi, S. D. H., & Marshall, A. G.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-09-01
- Volume
- 8
- Issue
- 9
- Pages
- 970-976
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W1981001077
- Cited by
- 462
- References
- 30
- FWCI
- 15.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.