An improved method for the automatic mapping of computed tomography numbers onto finite element models
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
The assignment of bone tissue material properties is a fundamental step in the generation of subject-specific finite element models from computed tomography data. Aim of the present work is to investigate the influence of the material mapping algorithm on the results predicted by the finite element analysis. Two models, a coarse and a refined one, of a human ileum, femur and tibia, were generated from CT data and used for the tests. In addition a convergence analysis was carried out for the femur model, using six refinement levels, to verify whether the inclusion of the material properties would significantly alter the convergence behaviour of the mesh. The results showed that the choice of the mapping algorithm influences the material distribution. However, this did not always propagate into the finite element results. The difference between the maximum Von Mises stress remained always lower than 10%, apart one case when it reached the 13%. However, the global behaviour of the meshes showed more marked differences between the two algorithms: in the finer meshes of the two long bones 20-30% of the bone volume showed differences in the predicted Von Mises stresses greater than 10%. The convergence behaviour of the model was not worsened by the introduction of inhomogeneous material properties. The software was made available in the public domain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001 · cited 2×
“The relationship between apparent density and Young’s modulus was derived from Carter and Heyes [9] for the whole density range.”
BackgroundMethodRelations of mechanical properties to density and CT numbers in human bone
Rho, J. Y., Hobatho, M. C., & Ashman, R. B. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)97314-f · Cited by 822
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
Predicting the compressive mechanical behavior of bone
Keller, T. S. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90056-6 · Cited by 667
Prediction of vertebral body compressive fracture using quantitative computed tomography.
McBroom, R. J., Hayes, W. C., Edwards, W. T., Goldberg, R. P., & White, A. A. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567080-00010 · Cited by 432
Ciarelli, M. J., Goldstein, S. A., Kuhn, J. L., Cody, D. D., & Brown, M. B. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090507 · Cited by 401 · cited 1×
“logical tissues [6–8] over a wide range of density values.”
BackgroundFracture Prediction for the Proximal Femur Using Finite Element Models: Part I—Linear Analysis
Lotz, J. C., Cheal, E. J., & Hayes, W. C. (1991) · Journal of Biomechanical Engineering · doi:10.1115/1.2895412 · Cited by 309
Development and Validation of a Three-Dimensional Finite Element Model of the Pelvic Bone
Dalstra, M., Huiskes, R., & van Erning, L. (1995) · Journal of Biomechanical Engineering · doi:10.1115/1.2794181 · Cited by 303
Statistical Methods in Medical Research.
Armitage, P., & Berry, G. (1997) · Biometrics · doi:10.2307/2533132 · Cited by 259
Keyak, J. H., & Rossi, S. A. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00152-9 · Cited by 250
Material properties assignment to finite element models of bone structures: a new method
Zannoni, C., Mantovani, R., & Viceconti, M. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(98)00081-2 · Cited by 210
Self-citationA three-dimensional finite element model from computed tomography data: A semi-automated method
Cattaneo, P. M., Dalstra, M., & Frich, L. H. (2001) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/0954411011533760 · Cited by 108
The prediction of stress fractures using a ‘stressed volume’ concept
Taylor, D. M., & Kuiper, J. (2001) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(01)00009-2 · Cited by 93
Femoral structure and stiffness in patients with femoral neck fracture
CODY, D. D., Hou, F. J., Divine, G., & Fyhrie, D. P. (2000) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100180317 · Cited by 50
Computer aided stress analysis of long bones utilizing computed tomography
Marom, S. A., & Linden, M. J. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90294-d · Cited by 50
Tho, M. H. B., Darmana, R., Pastor, P., Barrau, J. J., Laroze, S., & Morucci, J. P. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90026-j · Cited by 49
Automated Finite Element Analysis of Excised Human Femora Based on Precision-QCT
Merz, B., Niederer, P. F., Müller, R., & Ruegsegger, P. (1996) · Journal of Biomechanical Engineering · doi:10.1115/1.2796021 · Cited by 40
Cited by
Mathematical relationships between bone density and mechanical properties: A literature review
Helgason, B., Perilli, E., Schileo, E., Taddei, F., Brynjólfsson, S., & Viceconti, M. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.08.024 · Cited by 589
Self-citationSchileo, E., Dall’Ara, E., Taddei, F., Malandrino, A., Schotkamp, T., Baleani, M., & Viceconti, M. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.05.017 · Cited by 372
Self-citationTaddei, F., Schileo, E., Helgason, B., Cristofolini, L., & Viceconti, M. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.10.014 · Cited by 339
Self-citationSubject-specific finite element models can accurately predict strain levels in long bones
Schileo, E., Taddei, F., Malandrino, A., Cristofolini, L., & Viceconti, M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.02.010 · Cited by 330
Self-citationPeng, L., Bai, J., Zeng, X., & Zhou, Y. (2006) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2005.06.003 · Cited by 262
Metadata
- Authors
- Taddei, F., Pancanti, A., & Viceconti, M.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2003-09-19
- Volume
- 26
- Issue
- 1
- Pages
- 61-69
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2023878636
- Cited by
- 274
- References
- 17
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.