Serial registration of intraoperative MR images of the brain
The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kass, M., Witkin, A., & Terzopoulos, D. (1988) · International Journal of Computer Vision · doi:10.1007/bf00133570 · Cited by 17,070 · cited 1×
“Classically, the image force is computed as a decreasing function of the gradient of the target image so as to be minimized at the edges in the target image ( Kass et al., 1988; Cohen and Cohen, 1993).”
BackgroundZienkiewicz, O. C. (1989) · Cited by 14,802
(1973) · CERN Document Server (European Organization for Nuclear Research) · Cited by 12,895
Horn, B. K., & Schunck, B. G. (1981) · SPIE Proceedings · doi:10.1117/12.965761 · Cited by 7,394 · cited 1×
“Early work for recovering image deformation was based on the minimization of the sum of squared differences (SSD) between the images to be matched using a quadratic regularizer (Horn and Schunck, 1981).”
MethodNonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265 · cited 2×
“The opening of the skull and the dura cause 1998; Gaens et al., 1998; Rueckert et al., 1999; Thiran and several parts of the brain to be removed on the image, Butz, 2000), and normalized cross-correlation (e.g. Bajcsy creating black holes, and thus sudden discontinuities at and Kovacic, 1989;…”
BackgroundMedical image analysis: progress over two decades and the challenges ahead
Duncan, J. S., & Ayache, N. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.824822 · Cited by 4,140
Automatic 3D intersubject registration of MR volumetric data in standardized Talairach space
Collins, D. L., Neelin, P., Peters, T. M., & Evans, A. C. (1994) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199403000-00005 · Cited by 3,431 · cited 3×
“…et al., 1999; Thiran and several parts of the brain to be removed on the image, Butz, 2000), and normalized cross-correlation (e.g. Bajcsy creating black holes, and thus sudden discontinuities at and Kovacic, 1989; Collins et al., 1994; Rexilius et al., some locations in the image sequence.”
BackgroundMethodMulti-modal volume registration by maximization of mutual information
Wells, W. M., Viola, P., Atsumi, H., Nakajima, S., & Kikinis, R. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80004-9 · Cited by 1,959 · cited 2×
“…it) is aligned with several image voxels so as to limit computational complex- the intraoperative data using a mutual information (MI)ity without sacrificing accuracy. based rigid registration method (Wells et al., 1996; Gering We generate tetrahedral meshes with a multi-resolution et al., 1999).”
BackgroundMethodFinite-element methods for active contour models and balloons for 2-D and 3-D images
Cohen, L. D., & Cohen, I. (1993) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.244675 · Cited by 1,378 · cited 4×
“This task is extremely difficult equation (Cohen and Cohen, 1993): because the intraoperatively acquired data have limited t21t t21 vresolution and contrast, and it is therefore often difficult to (I 1tA)v 5 v 2tF , (1) distinguish between tissue types.”
BackgroundMethodInfluentialThe computation of optical flow
Beauchemin, S. S., & Barron, J. L. (1995) · ACM Computing Surveys · doi:10.1145/212094.212141 · Cited by 1,278 · cited 1×
“Successive evolutions of similar techniques have been proposed, and are often being referred to as optical flow methods (see Bauchemin and Barron (1995) for a complete review).”
MethodMultiresolution elastic matching
Bajcsy, R., & Kovačič, S. (1989) · Computer Vision, Graphics, and Image Processing · doi:10.1016/s0734-189x(89)80014-3 · Cited by 1,106 · cited 1×
“Exploiting a suggestion of Dengler and Schmidt (1988a), Previous algorithms developed to capture brain deforma- Bajcsy and Kovacic (1989) and Gee et al. (1993) sub- sequently implemented multiresolution versions of Broits 1 .3.”
MethodConstitutive modelling of brain tissue: Experiment and theory
Miller, K., & Chinzei, K. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00092-4 · Cited by 526 · cited 1×
“However, it must be noted that the pathway (2000), Miller and Chinzei (1997) and Miller et al. leading to the tumor for instance is not resected but just In this study, we have tracked brain deformation using a has been observed to swell at the boundaries with the fully 3D finite element…”
BackgroundA surface-based technique for warping three-dimensional images of the brain
Thompson, P., & Toga, A. W. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.511745 · Cited by 516 · cited 1×
“(Davatzikos, 1997; Thompson and Toga, 1996 )) that provide a way to match boundaries of common image structures in the images.”
BackgroundMechanical properties of brain tissue in-vivo: experiment and computer simulation
Miller, K., Chinzei, K., Orssengo, G., & Bednarz, P. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00120-2 · Cited by 501 · cited 1×
“For larger displacements, we are intending to investigate non-linear elasticity models such as the models described by Picinbono and Ayache (2000) and Miller and Chinzei (1997); Miller et al. (2000) .”
MethodSerial Intraoperative Magnetic Resonance Imaging of Brain Shift
Nabavi, A., Black, P. M., Gering, D. T., Westin, C.-F., Mehta, V., Pergolizzi, R. S., Ferrant, M., Warfield, S. K., Hata, N., Schwartz, R. B., et al. (2001) · Neurosurgery · doi:10.1097/00006123-200104000-00019 · Cited by 461 · cited 8×
“…a result, cortical surface shifts ranging between 1.2 registration techniques that have been proposed for intraand 20 mm have been observed (Nabavi et al., 2001; operative registration (Section 1.3) and biomechanical Roberts et al., 1998), while subsurface shift can range up models that…”
BackgroundMethodInfluentialSelf-citationVolumetric transformation of brain anatomy
Christensen, G. E., Joshi, S. C., & Miller, M. I. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.650882 · Cited by 438 · cited 1×
“The elastically deformable volumes have become a very active area of research and have been extended to viscous fluid deformable volumes (Christensen, 1994; BroNielsen and Gramkow, 1996; Christensen et al., 1997) in an attempt to overcome the small deformation assumptions inherent in the linear elastic formulations.”
BackgroundAutomated Segmentation of MR Images of Brain Tumors
Kaus, M. R., Warfield, S. K., Nabavi, A., Black, P. M., Jolesz, F. A., & Kikinis, R. (2001) · Radiology · doi:10.1148/radiology.218.2.r01fe44586 · Cited by 423
Measurement of Intraoperative Brain Surface Deformation under a Craniotomy
Hill, D. L. G., Maurer, C. R., Maciunas, R. J., Maciunas, R. J., Barwise, J. A., Fitzpatrick, J. M., & Wang, M. Y. (1998) · Neurosurgery · doi:10.1097/00006123-199809000-00066 · Cited by 404
Adaptive, template moderated, spatially varying statistical classification
Warfield, S. K., Kaus, M., Jolesz, F. A., & Kikinis, R. (2000) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00003-7 · Cited by 402 · cited 3×
“The algorithm uses the segmentation of pre- right minimum provided time stept is small enough and operative data as a template for the segmentation of the initial surface not too far from its target shape. intraoperative data (Warfield et al., 2000a,b).”
MethodSelf-citationFast Fluid Registration of medical images
Bro-Nielsen, M., & Gramkow, C. (1996) · Lecture Notes in Computer Science · doi:10.1007/bfb0046964 · Cited by 395 · cited 2×
“…main issues when matching intraoperative images to have been extended to viscous fluid deformable volumes pre-operative images: (Christensen, 1994; Bro-Nielsen and Gramkow, 1996; • Intensity variations between the pre-operative and intraChristensen et al., 1997) in an attempt to overcome the…”
BackgroundSpatial Transformation and Registration of Brain Images Using Elastically Deformable Models
Davatzikos, C. (1997) · Computer Vision and Image Understanding · doi:10.1006/cviu.1997.0605 · Cited by 375 · cited 1×
“…of brain matching a volumetric deformation field from surface-based de- applications (Warfield et al., 1995, 1999; Warfield, 1996; formations (e.g. Davatzikos, 1997; Thompson and Toga, Nakajima et al., 1997; Hata et al., 1998, 2000; Ferrant et 1996) that provide a way to match boundaries of…”
MethodElastically Deforming 3D Atlas to Match Anatomical Brain Images
Gee, J. C., Reivich, M., & Bajcsy, R. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199303000-00011 · Cited by 342 · cited 1×
“Exploiting a suggestion of Dengler and Schmidt (1988a), Previous algorithms developed to capture brain deforma- Bajcsy and Kovacic (1989) and Gee et al. (1993) sub- sequently implemented multiresolution versions of Broits 1 .3.”
MethodRegistration of 3-d intraoperative MR images of the brain using a finite-element biomechanical model
Ferrant, M., Nabavi, A., Macq, B., Jolesz, F. A., Kikinis, R., & Warfield, S. K. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.974933 · Cited by 339 · cited 4×
“The intraoperative image data then together volumetric version of the marching tetrahedra algorithm with the spatial localization model form a multichannel 3D (Ferrant et al., 2001).”
BackgroundMethodInfluentialSelf-citationOptimal registration of deformed images
Broit, C. (1981) · Scholarly Commons (University of Pennsylvania) · Cited by 329
Grimson, W. E. L., Ettinger, G. J., White, S. J., Lozano-Perez, T., Wells, W. M., & Kikinis, R. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.491415 · Cited by 316
Toward realistic soft-tissue modeling in medical simulation
Delingette, H. (1998) · Proceedings of the IEEE · doi:10.1109/5.662876 · Cited by 303 · cited 1×
“There has also been a significant amount of work directed towards simulation (see Delinguette (1998) for a review) using models driven by physics-based forces such as gravity.”
BackgroundConstitutive model of brain tissue suitable for finite element analysis of surgical procedures
Miller, K. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00010-x · Cited by 263
Frameless stereotaxic integration of CT imaging data: accuracy and initial applications.
Zinreich, S. J., Tebo, S. A., Long, D. M., Brem, H., Mattox, D. E., Loury, M. E., vander Kolk, C. A., Koch, W. M., Kennedy, D. W., & Bryan, R. N. (1993) · Radiology · doi:10.1148/radiology.188.3.8351341 · Cited by 244 · cited 1×
“This can be done using a stereotactic frame (Kelly, 1986), or with frameless registration systems (Zamorano et al., 1992; Zinreich et al., 1993; Grimson et al., 1996).”
MethodRoutine quantitative analysis of brain and cerebrospinal fluid spaces with MR imaging
Kikinis, R., Shenton, M. E., Gerig, G., Martin, J., Anderson, M., Metcalf, D., Guttmann, C. R. G., McCarley, R. W., Jolesz, F. A., Lorensen, W., et al. (1992) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880020603 · Cited by 237 · cited 2×
“In our laboratory, preoperative data is segmented with a variety of manual (Gering et al., 1999), semi-automated ( Kikinis et al., 1992 ) or automated (Warfield et al., 1995, 2000a; Kaus et al., 2000) approaches.”
MethodGuimond, A., Roche, A., Ayache, N., & Meunier, J. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906425 · Cited by 215 · cited 2×
“To circumvent that problem, methods have been proposed so as to be able to cope with images imaged with different parameters or modalities (e.g. Guimond et al. (2001) ).”
MethodPhysics-Based Deformable Models: Applications to Computer Vision, Graphics, and Medical Imaging
Metaxas, D. (1996) · Kluwer Academic Publishers eBooks · Cited by 205
Maurer, C. R., Hill, D. L. G., Martin, A. J., Liu, H., McCue, M., Rueckert, D., Lloret, D., Hall, W. A., Maxwell, R. E., Hawkes, D. J., et al. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.736050 · Cited by 195 · cited 2×
“…image-based disappearance of tension and pressure forces at the brain models and those using biomechanical simulation models. and ventricular boundaries (Bucholz et al., 1997; Hill et Image-based models are typically used when intraoperative al., 1998; Maurer et al., 1998; Nabavi et al., 2001).”
BackgroundMethodWarfield, S. K., Dengler, J., Zaers, J., Guttmann, C. R. G., Wells, W. M., Ettinger, G. J., Hiller, J. B., & Kikinis, R. (1995) · Journal of Image Guided Surgery · doi:10.1002/(sici)1522-712x(1995)1:6<326::aid-igs4>3.0.co;2-c · Cited by 183 · cited 5×
“Preoperative segmentation: key objects whose shape will change over the course of surgery are precisely segmented from preoperatively acquired images using the algorithm described by Warfield et al. (2000a),”
MethodInfluentialKyriacou, S. K., Davatzikos, C., Zinreich, S. J., & Bryan, R. N. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.790458 · Cited by 164 · cited 2×
“linear elasticity models discretized using the Finite Element (FE) Method) have been explicitly proposed to constrain image registration (Kyriacou et al., 1999; Hagemann et al., 1999).”
MethodNonrigid registration of 3D tensor medical data
Ruiz‐Alzola, J., Westin, C., Warfield, S. K., Alberola‐López, C., Maier, S. E., & Kikinis, R. (2002) · Medical Image Analysis · doi:10.1016/s1361-8415(02)00055-5 · Cited by 156
Fast Euclidean Distance Transformation by Propagation Using Multiple Neighborhoods
Cuisenaire, O., & Macq, B. M. M. (1999) · Computer Vision and Image Understanding · doi:10.1006/cviu.1999.0783 · Cited by 148 · cited 2×
“…(linear computational preoperative data (including any MRI/ fMRI/PET/MRA cost with respect to the amount of voxels in the image) using a fast Euclidean distance transformation algorithm In the case of linear elasticity, with no initial stresses or (Cuisenaire and Macq, 1999; Cuisenaire, 1999).”
MethodThree-dimensional multimodal image-guidance for neurosurgery
Peters, T., Davey, B., Munger, P., Comeau, R., Evans, A., & Olivier, A. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.491414 · Cited by 128 · cited 2×
“…1999; Nimsky et al., 2000; Nabavi et al., 2001): imaging (MRI), computed tomography (CT), positron • physical manipulation of the brain: dura opening, emission tomography (PET), etc.) with the patients posi- retraction and resection, draining and leakage of the tion in the OR (Peters et al., 1996).”
BackgroundMethodTroccaz, J., Mösges, R., & Grimson, W. E. L. (1997) · Lecture notes in computer science · doi:10.1007/bfb0029218 · Cited by 117
Physical model-based non-rigid registration incorporating statistical shape information
Wang, Y., & Staib, L. H. (2000) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00004-9 · Cited by 111 · cited 2×
“Using a statistical shape information of the objects to be matched volumetric optical flow approach, Hata et al. (2000) (e.g. Wang and Staib, 2000; Papademetris et al., 1999a). showed that because of the varying contrast intensity of the These methods use statistical boundary shape information…”
BackgroundMethodGeneral multimodal elastic registration based on mutual information
Maintz, J. B. A., Meijering, E. H. W., & Viergever, M. A. (1998) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.310845 · Cited by 94 · cited 1×
“(Maintz et al., 1998; Gaens et al., 1998; Rueckert et al., 1999; Thiran and Butz, 2000)), and normalized crosscorrelation (e.”
Registration of 3D Intraoperative MR Images of the Brain Using a Finite Element Biomechanical Model
Ferrant, M., Warfield, S. K., Nabavi, A., Jolesz, F. A., & Kikinis, R. (2000) · Lecture notes in computer science · doi:10.1007/978-3-540-40899-4_3 · Cited by 93 · cited 4×
“As in our previous work ( Ferrant et al., 2000b, 2001 ), we rely on the study of Paulsen et al. (1999) and Miga et al. (1999) for choosing our coefficients ( ).”
BackgroundMethodInfluentialSelf-citationFast k-NN classification for multichannel image data
Warfield, S. K. (1996) · Pattern Recognition Letters · doi:10.1016/0167-8655(96)00036-0 · Cited by 90 · cited 2×
“Our laboratory has had extensive experience with image-based matching models for a variety of brain matching applications (Warfield et al., 1995; Warfield, 1996; Nakajima et al., 1997; Hata et al., 1998; Warfield et al., 1999; Ferrant et al., 1999b; Hata et al., 2000; Kaus, 2000; Ruiz-Alzola et al., 2001; Rexilius and…”
BackgroundMethodAutomated Segmentation of MRI of Brain Tumors
Kaus, M. R., Warfield, S. K., Nabavi, A., et al. (2001) · Cited by 87
Hata, N., Nabavi, A., Wells, W. M., Warfield, S. K., Kikinis, R., Black, P. M., & Jolesz, F. A. (2000) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200007000-00004 · Cited by 81 · cited 6×
“Using a statistical shape information of the objects to be matched volumetric optical flow approach, Hata et al. (2000) (e.g. Wang and Staib, 2000; Papademetris et al., 1999a). showed that because of the varying contrast intensity of the These methods use statistical boundary shape information…”
BackgroundMethodInfluentialNonlinear Registration and Template-Driven Segmentation
Warfield, S. K., Robatino, A., Dengler, J., Jolesz, F. A., & Kikinis, R. (1999) · Elsevier eBooks · doi:10.1016/b978-012692535-7/50080-x · Cited by 63
Multimodality deformable registration of pre- and intraoperative images for MRI-guided brain surgery
Hata, N., Dohi, T., Warfield, S. K., Wells, W. M., Kikinis, R., & Jolesz, F. A. (1998) · Lecture notes in computer science · doi:10.1007/bfb0056296 · Cited by 56 · cited 2×
“…de- applications (Warfield et al., 1995, 1999; Warfield, 1996; formations (e.g. Davatzikos, 1997; Thompson and Toga, Nakajima et al., 1997; Hata et al., 1998, 2000; Ferrant et 1996) that provide a way to match boundaries of common al., 1999b; Kaus, 2000; Ruiz-Alzola et al., 2002; Rexilius…”
BackgroundIntraoperative diffusion imaging on a 0.5 Tesla interventional scanner
Mamata, Y., Mamata, H., Nabavi, A., Kacher, D. F., Pergolizzi, R. S., Schwartz, R. B., Kikinis, R., Jolesz, F. A., & Maier, S. E. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200101)13:1<115::aid-jmri1017>3.0.co;2-x · Cited by 53 · cited 2×
“To this effect, tensor diffusion images are currently being acquired before and during surgery ( Mamata et al., 2001 ), and can help measure anisotropy directions within white and gray matter.”
BackgroundA Novel Nonrigid Registration Algorithm and Applications
Rexilius, J., Warfield, S. K., Guttmann, C. R. G., Wei, X., Benson, R. R., WOLFSON, L. I., Shenton, M. E., Heinz Handels, A., & Kikinis, R. (2001) · Lecture notes in computer science · doi:10.1007/3-540-45468-3_110 · Cited by 43
Deformable Modeling for Characterizing Biomedical Shape Changes
Ferrant, M., Macq, B. M. M., Nabavi, A., & Warfield, S. K. (2000) · Lecture notes in computer science · doi:10.1007/3-540-44438-6_20 · Cited by 31 · cited 7×
“This model will be (Ferrant et al., 2000b, 2001). deformed during surgery to match the shape changes of the • Interpolate deformation field and deform image: the objects it represents.”
BackgroundMethodInfluentialSelf-citationIntraoperative Segmentation and Nonrigid Registration for Image Guided Therapy
Warfield, S. K., Nabavi, A., Butz, T., Tuncali, K., Silverman, S. G., Black, P. M., Jolesz, F. A., & Kikinis, R. (2000) · Lecture notes in computer science · doi:10.1007/978-3-540-40899-4_18 · Cited by 28 · cited 7×
“whose shape will change over the course of surgery are precisely segmented from preoperatively acquired images using the algorithm described by Warfield et al. (2000a) ,”
MethodInfluential
Cited by
Medical image registration: a review
Oliveira, F. P. M., & Tavares, J. M. R. S. (2014) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2012.670855 · Cited by 737
Non-rigid image registration: theory and practice
Crum, W. R., Hartkens, T., & Hill, D. L. G. (2004) · The British Journal of Radiology · doi:10.1259/bjr/25329214 · Cited by 719
Brain shift in neuronavigation of brain tumors: A review
Gerard, I. J., Kersten-Oertel, M., Petrecca, K., Sirhan, D., Hall, J. A., & Collins, D. L. (2017) · Medical Image Analysis · doi:10.1016/j.media.2016.08.007 · Cited by 324
Neuronavigation in the surgical management of brain tumors: current and future trends
Orringer, D. A., Golby, A., & Jolesz, F. (2012) · Expert Review of Medical Devices · doi:10.1586/erd.12.42 · Cited by 267
Robust nonrigid registration to capture brain shift from intraoperative MRI
Clatz, O., Delingette, H., Talos, I.-F., Golby, A. J., Kikinis, R., Jolesz, F. A., Ayache, N., & Warfield, S. K. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.856734 · Cited by 234
“[24] extracted the full cortex and ventricles surfaces from intraoperative MR images to constrain the displacement of the surface of a linear finite element model.”
Method
Metadata
- Authors
- Ferrant, M.
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 2002-12
- Volume
- 6
- Issue
- 4
- Pages
- 337-359
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W2066805957
- Cited by
- 203
- References
- 50
- FWCI
- 15.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.