Scalp electrode impedance, infection risk, and EEG data quality
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electric Fields of the Brain: The Neurophysics of EEG
Nunez, P. L., & Harth, E. (1982) · Physics Today · doi:10.1063/1.2915137 · Cited by 2,232
Picton, T. W., Bentin, S., Berg, P., Donchin, E., Hillyard, S. A., Johnson, R., Miller, G. A., Ritter, W., Ruchkin, D. S., Rugg, M. D., et al. (2000) · Psychophysiology · doi:10.1111/1469-8986.3720127 · Cited by 2,157
Report of the Committee on Infectious Diseases
Nider, H. (1989) · Archives of Dermatology · doi:10.1001/archderm.1989.01670190156031 · Cited by 1,911
Electric Fields of the Brain: The Neurophysics of EEG
Fermaglich, J. (1982) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1982.03320380071046 · Cited by 1,543
Spatial sampling of head electrical fields: the geodesic sensor net
Tucker, D. M. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90121-b · Cited by 751
Self-citationEEG Electrode Sensitivity-An Application of Reciprocity
Rush, S., & Driscoll, D. A. (1969) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1969.4502598 · Cited by 448
60-Hz Interference in Electrocardiography
Huhta, J. C., & Webster, J. G. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324169 · Cited by 412
Estimating the spatial Nyquist of the human EEG
Srinivasan, R., Tucker, D. M., & Murias, M. (1998) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03209412 · Cited by 247
Self-citationMinimizing Electrode Motion Artifact by Skin Abrasion
Tam, H., & Webster, J. G. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326117 · Cited by 220
Analysis and Control of the Current Distribution under Circular Dispersive Electrodes
Wiley, J. D., & Webster, J. G. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324910 · Cited by 181
Cited by
Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review
Chi, Y. M., Jung, T.-P., & Cauwenberghs, G. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084078 · Cited by 1,061
Electrophysiological correlates for response inhibition in a Go/NoGo task
Bokura, H., Yamaguchi, S., & Kobayashi, S. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00691-5 · Cited by 767
Keil, A., Debener, S., Gratton, G., Junghöfer, M., Kappenman, E. S., Luck, S. J., Luu, P., Miller, G. A., & Yee, C. M. (2014) · Psychophysiology · doi:10.1111/psyp.12147 · Cited by 699
Self-citationIssues and assumptions on the road from raw signals to metrics of frontal EEG asymmetry in emotion
Allen, J. J. B., Coan, J. A., & Nazarian, M. (2004) · Biological Psychology · doi:10.1016/j.biopsycho.2004.03.007 · Cited by 645
Flexible Hybrid Electronics for Digital Healthcare
Ma, Y., Zhang, Y., Cai, S., Han, Z., Liu, X., Wang, F., Cao, Y., Wang, Z., Li, H., Chen, Y., et al. (2020) · Advanced Materials · doi:10.1002/adma.201902062 · Cited by 620
Mu rhythm modulation during observation of an object-directed grasp
Muthukumaraswamy, S. D., Johnson, B. W., & McNair, N. A. (2004) · Cognitive Brain Research · doi:10.1016/j.cogbrainres.2003.12.001 · Cited by 585
The effects of electrode impedance on data quality and statistical significance in ERP recordings
Kappenman, E. S., & Luck, S. J. (2010) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01009.x · Cited by 447
Tokowicz, N., & MacWhinney, B. (2005) · Studies in Second Language Acquisition · doi:10.1017/s0272263105050102 · Cited by 419
Lopez-Gordo, M., Sanchez-Morillo, D., & Valle, F. (2014) · Sensors · doi:10.3390/s140712847 · Cited by 410
Gu, X., Cao, Z., Jolfaei, A., Xu, P., Wu, D., Jung, T.-P., & Lin, C.-T. (2021) · IEEE/ACM Transactions on Computational Biology and Bioinformatics · doi:10.1109/tcbb.2021.3052811 · Cited by 395
Norton, J. J. S., Lee, D. S., Lee, J. W., Lee, W., Kwon, O., Won, P., Jung, S.-Y., Cheng, H., Jeong, J.-W., Akce, A., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1424875112 · Cited by 387
Interpersonal body and neural synchronization as a marker of implicit social interaction
Yun, K., Watanabe, K., & Shimojo, S. (2012) · Scientific Reports · doi:10.1038/srep00959 · Cited by 379
EEG-based workers' stress recognition at construction sites
Jebelli, H., Hwang, S., & Lee, S. (2018) · Automation in Construction · doi:10.1016/j.autcon.2018.05.027 · Cited by 339
Novel Dry Polymer Foam Electrodes for Long-Term EEG Measurement
Lin, C.-T., Liao, L.-D., Liu, Y.-H., Wang, I.-J., Lin, B.-S., & Chang, J.-Y. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2102353 · Cited by 336
Reynolds, G. D., & Richards, J. E. (2005) · Developmental Psychology · doi:10.1037/0012-1649.41.4.598 · Cited by 321
Cognition in action: imaging brain/body dynamics in mobile humans
Gramann, K., Gwin, J. T., Ferris, D. P., Oie, K., Jung, T.-P., Lin, C.-T., Liao, L.-D., & Makeig, S. (2011) · Reviews in the Neurosciences · doi:10.1515/rns.2011.047 · Cited by 302
Berkovich-Ohana, A., Glicksohn, J., & Goldstein, A. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2011.07.048 · Cited by 298
Emerging Neurophysiological Specialization for Letter Strings
Maurer, U., Brem, S., Bucher, K., & Brandeis, D. (2005) · Journal of Cognitive Neuroscience · doi:10.1162/089892905774597218 · Cited by 294
Wearable, Wireless EEG Solutions in Daily Life Applications: What are we Missing?
Mihajlovic, V., Grundlehner, B., Vullers, R., & Penders, J. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2328317 · Cited by 289
Debener, S., Makeig, S., Delorme, A., & Engel, A. K. (2005) · Cognitive Brain Research · doi:10.1016/j.cogbrainres.2004.09.006 · Cited by 287
Maurer, U., Brandeis, D., & McCandliss, B. D. (2005) · Behavioral and Brain Functions · doi:10.1186/1744-9081-1-13 · Cited by 284
EEG-based brain–computer interfaces
McFarland, D. J., & Wolpaw, J. R. (2017) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.11.004 · Cited by 283
Coarse neural tuning for print peaks when children learn to read
Maurer, U., Brem, S., Kranz, F., Bucher, K., Benz, R., Halder, P., Steinhausen, H.-C., & Brandeis, D. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.06.025 · Cited by 281
A 3D printed dry electrode for ECG/EEG recording
Salvo, P., Raedt, R., Carrette, E., Schaubroeck, D., Vanfleteren, J., & Cardon, L. (2012) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2011.12.017 · Cited by 264
The neurophysiological bases of EEG and EEG measurement: A review for the rest of us
Jackson, A. F., & Bolger, D. J. (2014) · Psychophysiology · doi:10.1111/psyp.12283 · Cited by 264
EEG applications for sport and performance
Thompson, T., Steffert, T., Ros, T., Leach, J., & Gruzelier, J. (2008) · Methods · doi:10.1016/j.ymeth.2008.07.006 · Cited by 260
Liao, L.-D., Chen, C.-Y., Wang, I.-J., Chen, S.-F., Li, S.-Y., Chen, B.-W., Chang, J.-Y., & Lin, C.-T. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-5 · Cited by 258
Bristle-sensors—low-cost flexible passive dry EEG electrodes for neurofeedback and BCI applications
Grozea, C., Voinescu, C. D., & Fazli, S. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025008 · Cited by 256
Human Brain Distinctiveness Based on EEG Spectral Coherence Connectivity
Rocca, D. L., Campisi, P., Vegso, B., Cserti, P., Kozmann, G., Babiloni, F., & Fallani, F. D. V. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2317881 · Cited by 256
A generic EEG artifact removal algorithm based on the multi-channel Wiener filter
Somers, B., Francart, T., & Bertrand, A. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaac92 · Cited by 255
Wireless and Wearable EEG System for Evaluating Driver Vigilance
Lin, C.-T., Chuang, C.-H., Huang, C.-S., Tsai, S.-F., Lu, S.-W., Chen, Y.-H., & Ko, L.-W. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2316224 · Cited by 250
“These procedures are time consuming, uncomfortable, and even painful for participants [18], [19].”
BackgroundChanges in rolandic mu rhythm during observation of a precision grip
Muthukumaraswamy, S. D., & Johnson, B. W. (2004) · Psychophysiology · doi:10.1046/j.1469-8986.2003.00129.x · Cited by 249
Supervised Network-Based Fuzzy Learning of EEG Signals for Alzheimer's Disease Identification
Yu, H., Lei, X., Song, Z., Liu, C., & Wang, J. (2020) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2019.2903753 · Cited by 246
“Studies have demonstrated that there is no significant change in EEG amplitude across frequency bands as scalp–electrode impedance less than 10 kΩ [46].”
BackgroundSoft, Comfortable Polymer Dry Electrodes for High Quality ECG and EEG Recording
Chen, Y.-H., De Beeck, M., Vanderheyden, L., Carrette, E., Mihajlović, V., Vanstreels, K., Grundlehner, B., Gadeyne, S., Boon, P., & Van Hoof, C. (2014) · Sensors · doi:10.3390/s141223758 · Cited by 238
“Moreover, since these electrodes penetrate into the SC, they might cause irritation and infections, especially in case of breached skin [10].”
Meghdadi, A. H., Stevanović Karić, M., McConnell, M., Rupp, G., Richard, C., Hamilton, J., Salat, D., & Berka, C. (2021) · PLOS ONE · doi:10.1371/journal.pone.0244180 · Cited by 229
Imaging natural cognition in action
Gramann, K., Ferris, D. P., Gwin, J., & Makeig, S. (2014) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2013.09.003 · Cited by 227
“In case of high-density EEG recordings, connecting electrodes to the scalp using conductive gel can lead to short circuits between proximal electrodes (Roberto, 2010) and degradation of signal quality over longer measurement periods may be observed (Ferree et al., 2001).”
Primary motor cortex activation during action observation revealed by wavelet analysis of the EEG
Muthukumaraswamy, S. D., & Johnson, B. W. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.03.004 · Cited by 224
“Electrode impedances were below 40 kV, an acceptable level for this system (Ferree et al., 2001).”
BackgroundSkin Conformal Polymer Electrodes for Clinical ECG and EEG Recordings
Stauffer, F., Thielen, M., Sauter, C., Chardonnens, S., Bachmann, S., Tybrandt, K., Peters, C., Hierold, C., & Vörös, J. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700994 · Cited by 223
Size matters: effects of stimulus size, duration and eccentricity on the visual gamma-band response
Busch, N. A., Debener, S., Kranczioch, C., Engel, A. K., & Herrmann, C. S. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.03.015 · Cited by 221
“Sensor impedances were maintained below 20 kV prior data acquisition (Ferree et al., 2001).”
Simultaneous EEG-fMRI during a Working Memory Task: Modulations in Low and High Frequency Bands
Michels, L., Bucher, K., Lüchinger, R., Klaver, P., Martin, E., Jeanmonod, D., & Brandeis, D. (2010) · PLoS ONE · doi:10.1371/journal.pone.0010298 · Cited by 220
“The few electrodes with high impedances (between 20–50 kOhm) nonetheless delivered reliable EEG-signal [38].”
BackgroundHigh and dry? Comparing active dry EEG electrodes to active and passive wet electrodes
Mathewson, K. E., Harrison, T. J. L., & Kizuk, S. A. D. (2017) · Psychophysiology · doi:10.1111/psyp.12536 · Cited by 211
The effect of a naturalistic stressor on frontal EEG asymmetry, stress, and health
Lewis, R. S., Weekes, N. Y., & Wang, T. H. (2007) · Biological Psychology · doi:10.1016/j.biopsycho.2007.03.004 · Cited by 203
Towards multilevel mental stress assessment using SVM with ECOC: an EEG approach
Al-shargie, F., Tang, T. B., Badruddin, N., & Kiguchi, M. (2018) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-017-1733-8 · Cited by 192
The time course of brain activity in reading English and Chinese: An ERP study of Chinese bilinguals
Liu, Y., & Perfetti, C. A. (2003) · Human Brain Mapping · doi:10.1002/hbm.10090 · Cited by 189
“All impedances were kept below 40K [Ferree et al., 2001].”
BackgroundEEG-based mild depressive detection using feature selection methods and classifiers
Li, X., Hu, B., Sun, S., & Cai, H. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2016.08.010 · Cited by 189
Towards gel-free electrodes: A systematic study of electrode-skin impedance
Li, G., Wang, S., & Duan, Y. Y. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.10.005 · Cited by 187
A robust adaptive denoising framework for real-time artifact removal in scalp EEG measurements
Kilicarslan, A., Grossman, R. G., & Contreras-Vidal, J. L. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026013 · Cited by 184
“These are relatively low impedance changes, and according to [19, 20], are not expected to have major amplitude changes especially under cool and dry experimental conditions.”
BackgroundLiao, L.-D., Wang, I.-J., Chen, S.-F., Chang, J.-Y., & Lin, C.-T. (2011) · Sensors · doi:10.3390/s110605819 · Cited by 181
“The impedance variation of the dry EEG sensor was in the range from 4 to 14 kΩ, which is in the acceptable range for normal EEG measurements [11,37,38].”
BackgroundMXene-infused bioelectronic interfaces for multiscale electrophysiology and stimulation
Driscoll, N., Erickson, B., Murphy, B. B., Richardson, A. G., Robbins, G., Apollo, N. V., Mentzelopoulos, G., Mathis, T., Hantanasirisakul, K., Bagga, P., et al. (2021) · Science Translational Medicine · doi:10.1126/scitranslmed.abf8629 · Cited by 180
Longitudinal EEG power in the first postnatal year differentiates autism outcomes
Gabard-Durnam, L. J., Wilkinson, C., Kapur, K., Tager-Flusberg, H., Levin, A. R., & Nelson, C. A. (2019) · Nature Communications · doi:10.1038/s41467-019-12202-9 · Cited by 179
Maurer, U., Zevin, J. D., & McCandliss, B. D. (2008) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2008.20125 · Cited by 178
“Data were sampled at 500 Hz/channel with filter settings 0.1– 100 Hz. Impedance was kept below 50 k, which is a standard procedure that is specific to use with the particular combination of high impedance amplifiers and geodesic sensor nets employed in this study ( Ferree, Luu, Russell, & Tucker, 2001 ).”
MethodInfluentialReview of semi-dry electrodes for EEG recording
Li, G.-L., Wu, J.-T., Xia, Y.-H., He, Q.-G., & Jin, H.-G. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abbd50 · Cited by 178
Long‐term potentiation of human visual evoked responses
Teyler, T. J., Hamm, J. P., Clapp, W. C., Johnson, B. W., Corballis, M. C., & Kirk, I. J. (2005) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2005.04007.x · Cited by 174
“Electrode impedances were kept below 30 kW, an acceptable level for this system (Ferree et al., 2001).”
BackgroundWang, M., El-Fiqi, H., Hu, J., & Abbass, H. A. (2019) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2019.2916403 · Cited by 172
“More importantly, uni-variate features can be easily affected by the changes of EEG amplitudes which are caused by inevitable physiologic or psychological factors such as circadian rhythms [24], different signal acquisition solutions or simply recording conditions [25].”
BackgroundYang, S., Cheng, J., Shang, J., Hang, C., Qi, J., Zhong, L., Rao, Q., He, L., Liu, C., Ding, L., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-42149-x · Cited by 172
“It alsoreleases highlytoxic metalions intothe tissue and hasa risk of infection 26 .”
Sun, S., Li, X., Zhu, J., Wang, Y., La, R., Zhang, X., Wei, L., & Hu, B. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2894423 · Cited by 171
“Electrode impedance was kept below 50 k [39].”
BackgroundBiosensor Technologies for Augmented Brain–Computer Interfaces in the Next Decades
Liao, L.-D., Lin, C.-T., McDowell, K., Wickenden, A. E., Gramann, K., Jung, T.-P., Ko, L.-W., & Chang, J.-Y. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2012.2184829 · Cited by 169
Dong, G., Zhou, H., & Zhao, X. (2011) · Neuroscience Letters · doi:10.1016/j.neulet.2011.05.047 · Cited by 167
Liu, Y., Perfetti, C. A., & Hart, L. (2003) · Journal of Experimental Psychology: Learning, Memory, and Cognition · doi:10.1037/0278-7393.29.6.1231 · Cited by 166
“All impedances were kept below 40K ( Ferree, Luu, Russell, & Tucker, 2001 ).”
Automatic and robust noise suppression in EEG and MEG: The SOUND algorithm
Mutanen, T. P., Metsomaa, J., Liljander, S., & Ilmoniemi, R. J. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.10.021 · Cited by 162
“Because MEG and EEG sensors are very sensitive, they are highly susceptible to noise contamination (Ferree et al., 2001; Vrba and Robinson, 2001), which may lead to erroneous interpretations of the cortical activity.”
BackgroundPollonini, L., Bortfeld, H., & Oghalai, J. S. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.005104 · Cited by 159
Alderman, B. L., Olson, R. L., Brush, C. J., & Shors, T. J. (2016) · Translational Psychiatry · doi:10.1038/tp.2015.225 · Cited by 125
Lewis, R. S., Goto, S. G., & Kong, L. L. (2008) · Personality and Social Psychology Bulletin · doi:10.1177/0146167207313731 · Cited by 118
Time course of electrocortical food-cue responses during cognitive regulation of craving
Meule, A., Kübler, A., & Blechert, J. (2013) · Frontiers in Psychology · doi:10.3389/fpsyg.2013.00669 · Cited by 96
Studying the default mode and its mindfulness-induced changes using EEG functional connectivity
Berkovich-Ohana, A., Glicksohn, J., & Goldstein, A. (2014) · Social Cognitive and Affective Neuroscience · doi:10.1093/scan/nst153 · Cited by 87
Ose Askvik, E., van der Weel, F. R. (., & van der Meer, A. L. H. (2020) · Frontiers in Psychology · doi:10.3389/fpsyg.2020.01810 · Cited by 86
Carmeli, C., Knyazeva, M. G., Cuénod, M., & Do, K. Q. (2012) · PLoS ONE · doi:10.1371/journal.pone.0029341 · Cited by 81
“[35].”
Elgort, I., Perfetti, C. A., Rickles, B., & Stafura, J. Z. (2015) · Language, Cognition and Neuroscience · doi:10.1080/23273798.2014.942673 · Cited by 72
Tsolaki, A. C., Kosmidou, V., Kompatsiaris, I. (., Papadaniil, C., Hadjileontiadis, L., Adam, A., & Tsolaki, M. (2017) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2017.03.025 · Cited by 70
“All the electrode impedances were kept below 50 kΩ as recommended (Ferree et al., 2001) for the high-input impedance amplifier (NetAmps 300, EGI, Eugene, OR, USA).”
Myllymaa, S., Muraja‐Murro, A., Westeren‐Punnonen, S., Hukkanen, T., Lappalainen, R., Mervaala, E., Töyräs, J., Sipilä, K., & Myllymaa, K. (2016) · Journal of Sleep Research · doi:10.1111/jsr.12425 · Cited by 66
van der Meer, A. L. H., & van der Weel, F. R. (. (2017) · Frontiers in Psychology · doi:10.3389/fpsyg.2017.00706 · Cited by 62
“A high-input EGI amplifier ensured amplification of signals at maximum impedance of 50 k as recommended for an optimal signal-to-noise ratio (Picton et al., 2000; Ferree et al., 2001).”
MethodMultimodal mild depression recognition based on EEG-EM synchronization acquisition network
Zhu, J., Wang, Y., La, R., Zhan, J., Niu, J., Zeng, S., & Hu, X. (2019) · IEEE Access · doi:10.1109/access.2019.2901950 · Cited by 56
“The data collection software was Net Station, with the sampling frequency set as 250Hz, and electrode impedance maintained below 60 k [64].”
MethodDhar, M., Been, P. H., Minderaa, R. B., & Althaus, M. (2010) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2010.06.014 · Cited by 56
McCauley, S. M., Hestvik, A., & Vogel, I. (2013) · Language and Speech · doi:10.1177/0023830911434277 · Cited by 19
Vilhelmsen, K., Agyei, S. B., van der Weel, F. R. (., & van der Meer, A. L. H. (2019) · Psychophysiology · doi:10.1111/psyp.13281 · Cited by 16
Infants’ brain responses to looming danger: degeneracy of neural connectivity patterns
van der Weel, F. R. (., Agyei, S. B., & van der Meer, A. L. H. (2019) · Ecological Psychology · doi:10.1080/10407413.2019.1615210 · Cited by 15
Developmental language disorder as syntactic prediction impairment
Hestvik, A., Epstein, B., Schwartz, R. G., & Shafer, V. L. (2022) · Frontiers in Communication · doi:10.3389/fcomm.2021.637585 · Cited by 11
“Electrode impedances were below 60 kOhm, acceptable for high impedance amplifiers (Ferree et al., 2001).”
Background
Metadata
- Authors
- Ferree, T. C., Luu, P., Russell, G. S., & Tucker, D. M.
- Venue
- Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 2001-03
- Volume
- 112
- Issue
- 3
- Pages
- 536-544
- ISSN
- 1388-2457 (ISSN-L)
- OpenAlex
- W2100240292
- Cited by
- 1,005
- References
- 14
- FWCI
- 5.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.