Cited by 229Heart Rate Variability and Autonomic ControlNon-Invasive Vital Sign MonitoringPhysical Activity and Health

Heart rate variability with photoplethysmography in 8 million individuals: a cross-sectional study

Open access
Natarajan, Aravind, Pantelopoulos, Alexandros, Emir-Farinas, Hulya, Natarajan, Pradeep·2020·The Lancet Digital Health

Abstract

Background Heart rate variability, or the variation in the time interval between consecutive heart beats, is a non-invasive dynamic metric of the autonomic nervous system and an independent risk factor for cardiovascular death. Consumer wrist-worn tracking devices using photoplethysmography, such as Fitbit, now provide the unique potential of continuously measuring surrogates of sympathetic and parasympathetic nervous system activity through the analysis of interbeat intervals. We aimed to leverage wrist-worn trackers to derive and describe diverse measures of cardiac autonomic function among Fitbit device users. Methods In this cross-sectional study, we collected interbeat interval data that are sent to a central database from Fitbit devices during a randomly selected 24 h period. Age, sex, body-mass index, and steps per day in the 90 days preceding the measurement were extracted. Interbeat interval data were cleaned and heart rate variability features were computed. We analysed heart rate variability metrics across the time (measured via the root mean square of successive RR interval differences [RMSSD] and SD of the RR interval [SDRR]), frequency (measured by high-frequency and low-frequency power), and graphical (measured by Poincare plots) domains. We considered 5 min windows for the time and frequency domain metrics and 60 min measurements for graphical domain metrics. Data from participants were analysed to establish the correlation between heart rate variability metrics and age, sex, time of day, and physical activity. We also determined benchmarks for heart rate variability (HRV) metrics among the users. Findings We included data from 8 203 261 Fitbit users, collected on Sept 1, 2018. HRV metrics decrease with age, and parasympathetic function declines faster than sympathetic function. We observe a strong diurnal variation in the heart rate variability. SDRR, low-frequency power, and Poincare S 2 show a significant variation with sex, whereas such a difference is not seen with RMSSD, high-frequency power, and Poincare S 1 . For males, when measured from 0600 h to 0700 h, the mean low-frequency power decreased by a factor of 66·5% and high-frequency power decreased by a factor of 82·0% from the age of 20 years to 60 years. For females, the equivalent factors were 69·3% and 80·9%, respectively. Comparing low-frequency power between males and females at the ages of 40–41 years, measured from 0600 h to 0700 h, we found excess power in males, with a Cohen's d effect size of 0·33. For high-frequency power, the equivalent effect size was −0·04. Increased daily physical activity, across age and sex, was highly correlated with improvement in diverse measures of heart rate variability in a dose-dependent manner. We provide benchmark tables for RMSSD, SDRR, high and low frequency powers, and Poincare S 1 and S 2 , separately for different ages and sex and computed at two times of the day. Interpretation Diverse metrics of cardiac autonomic health can be derived from wrist-worn trackers. Empirical distributions of heart rate variability can potentially be used as a framework for individual-level interpretation. Increased physical activity might yield improvement in heart rate variability and requires prospective trials for confirmation. Funding Fitbit.

Integrity signals

Registry

Crossref · 10.1016/s2589-7500(20)30246-6

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • A study on over 8 million fitbit users reported that young people who took 12,000-13,000 steps a day displayed 21.2% (males) and 22.9% (females) greater high frequency HRV than those who took 5,000-6,000 steps.

    “For example, a study on over 8 million fitbit users (Natarajan et al., 2020) reported that young people who took 12,000–13,000 steps a day displayed 21.2% (males) and 22.9% (females) greater high frequency HRV than those who took 5,000–6,000 steps.”

    From The Complex Construct of Wellbeing and the Role of Vagal Function (2022) · cites this paper as Natarajan et al., 2020

  • The largest study was conducted in 2019 in North America and included over 8 million participants (75.71%).

    “The largest study we identified was conducted in 2019 in North America and included over 8 million participants (75.71%) [153]; the second largest was a European study comprising 742,000 participants (6.85%) [162].”
  • Some large-scale population-based studies (11/179, 6.1%) relied on secondary data collected with mobile apps or web-based wearable platforms or provided through a wearable company.

    “Some large-scale population-based studies (11/179, 6.1%) relied on secondary data collected with mobile apps [87] or web-based wearable platforms [153] or provided through a wearable company [189].”
  • One study in North America, conducted in 2019 with over 8 million participants, dominated the image of the distribution of participants.

    “One study in North America, conducted in 2019 with over 8 million participants [153], dominated the image of the distribution of participants.”

Cites

Flagged first, then by citations

1 of the 32 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Natarajan, A., Pantelopoulos, A., Emir-Farinas, H., & Natarajan, P.
Affiliations
  • Fitbit (United States) (US)
  • Broad Institute (US)
Corresponding author
Natarajan, Pradeep
Venue
The Lancet Digital Health
Publisher
Elsevier BV
Published
2020-12
Volume
2
Issue
12
Pages
e650-e657
ISSN
2589-7500 (ISSN-L)
OpenAlex
W3107602031
Cited by
229
References
32
Citations by year
2026: 44 · 2025: 39 · 2024: 41 · 2023: 52 · 2022: 29 · 2021: 22 · 2020: 2
FWCI
16.23
Type
journal article
Language
en
Open access
Locations
  • The Lancet Digital Health (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Physiology › Physical Activity and Health
Keywords
heart rate variability, photoplethysmography, Fitbit, autonomic nervous system, parasympathetic function, sympathetic function, diurnal variation, sex differences, age-related decline, physical activity, Poincaré plot, low-frequency power, cardiovascular risk, wearable health devices, RMSSD, high-frequency power, cardiovascular mortality risk factors
MeSH terms
Wearable Electronic Devices, Adolescent, Adult, Age Factors, Aged, Cardiovascular Diseases, Cross-Sectional Studies, Female, Heart Rate, Humans, Male, Middle Aged, Parasympathetic Nervous System, Prospective Studies, Sex Factors, Sympathetic Nervous System, Exercise, Photoplethysmography, Telemedicine, Monitoring, Ambulatory, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review