The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Dependence of ion intensity in electrospray mass spectrometry on the concentration of the analytes in the electrosprayed solution
Abstract
ADVERTISEMENT RETURN TO ISSUEPREVArticleNEXTDependence of ion intensity in electrospray mass spectrometry on the concentration of the analytes in the electrosprayed solutionLiang. Tang and Paul. KebarleCite this: Anal. Chem. 1993, 65, 24, 3654–3668Publication Date (Print):December 15, 1993Publication History Published online1 May 2002Published inissue 15 December 1993https://pubs.acs.org/doi/10.1021/ac00072a020https://doi.org/10.1021/ac00072a020research-articleACS PublicationsRequest reuse permissionsArticle Views3217Altmetric-Citations417LEARN ABOUT THESE METRICSArticle Views are the COUNTER-compliant sum of full text article downloads since November 2008 (both PDF and HTML) across all institutions and individuals. These metrics are regularly updated to reflect usage leading up to the last few days.Citations are the number of other articles citing this article, calculated by Crossref and updated daily. Find more information about Crossref citation counts.The Altmetric Attention Score is a quantitative measure of the attention that a research article has received online. Clicking on the donut icon will load a page at altmetric.com with additional details about the score and the social media presence for the given article. Find more information on the Altmetric Attention Score and how the score is calculated. Share Add toView InAdd Full Text with ReferenceAdd Description ExportRISCitationCitation and abstractCitation and referencesMore Options Share onFacebookTwitterWechatLinked InRedditEmail Other access optionsGet e-Alertsclose Get e-Alerts
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray ion source. Another variation on the free-jet theme
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a002 · Cited by 2,082
XX. On the equilibrium of liquid conducting masses charged with electricity
Rayleigh, L. (1882) · The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786448208628425 · Cited by 1,825
Dole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
On the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
Dzidic, I., & Kebarle, P. (1970) · The Journal of Physical Chemistry · doi:10.1021/j100702a013 · Cited by 710
Self-citationField induced ion evaporation from liquid surfaces at atmospheric pressure
Thomson, B. A., & Iribarne, J. V. (1979) · The Journal of Chemical Physics · doi:10.1063/1.438198 · Cited by 631
Covey, T. R., Bonner, R. F., Shushan, B. I., Henion, J., & Boyd, R. K. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290021111 · Cited by 593
The Electrohydrodynamic Atomization of Liquids
Smith, D. P. H. (1986) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1986.4504754 · Cited by 389
Electrified droplet fission and the Rayleigh limit
Taflin, D. C., Ward, T. L., & Davis, E. J. (1989) · Langmuir · doi:10.1021/la00086a016 · Cited by 266
Tang, L., & Kebarle, P. (1991) · Analytical Chemistry · doi:10.1021/ac00023a009 · Cited by 260
Self-citation
Cited by
Practical implications of some recent studies in electrospray ionization fundamentals
Cech, N. B., & Enke, C. G. (2001) · Mass Spectrometry Reviews · doi:10.1002/mas.10008 · Cited by 1,435
Taylor, P. J. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.11.007 · Cited by 1,248
Bonfiglio, R., King, R. C., Olah, T. V., & Merkle, K. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990630)13:12<1175::aid-rcm639>3.0.co;2-0 · Cited by 939
Electrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905
Self-citationSpontaneous Generation of Hydrogen Peroxide from Aqueous Microdroplets
Lee, J. K., Walker, K. L., Han, H. S., Kang, J., Prinz, F. B., Waymouth, R. M., Nam, H. G., & Zare, R. N. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1911883116 · Cited by 717
Definitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
Murray, K. K., Boyd, R. K., Eberlin, M. N., Langley, G. J., Li, L., & Naito, Y. (2013) · Pure and Applied Chemistry · doi:10.1351/pac-rec-06-04-06 · Cited by 687
A brief overview of the present status of the mechanisms involved in electrospray mass spectrometry
Kebarle, P. (2000) · Journal of Mass Spectrometry · doi:10.1002/1096-9888(200007)35:7<804::aid-jms22>3.0.co;2-q · Cited by 675
Self-citationBanerjee, S., & Mazumdar, S. (2012) · International Journal of Analytical Chemistry · doi:10.1155/2012/282574 · Cited by 662
Effect of eluent on the ionization process in liquid chromatography–mass spectrometry
Kostiainen, R., & Kauppila, T. J. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.08.095 · Cited by 402
Mechanistic aspects of electrospray ionization
Bruins, A. P. (1998) · Journal of Chromatography A · doi:10.1016/s0021-9673(97)01110-2 · Cited by 368
Renew, J. E., & Huang, C.-H. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.05.056 · Cited by 356
Electrospray mass spectrometry (ESI‐MS) in the study of metal–ligand solution equilibria
Di Marco, V. B., & Bombi, G. G. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20070 · Cited by 355
On the mechanisms by which the charged droplets produced by electrospray lead to gas phase ions
Kebarle, P., & Peschke, M. (2000) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00598-x · Cited by 352
Self-citationFatty acid synthesis is required for breast cancer brain metastasis
Ferraro, G. B., Ali, A., Luengo, A., Kodack, D. P., Deik, A., Abbott, K. L., Bezwada, D., Blanc, L., Prideaux, B., Jin, X., et al. (2021) · Nature Cancer · doi:10.1038/s43018-021-00183-y · Cited by 326
Principles of Electrospray Ionization
Wilm, M. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.009407 · Cited by 311
Secondary Electrospray Ionization Ion Mobility Spectrometry/Mass Spectrometry of Illicit Drugs
Wu, C., Siems, W. F., & Hill, H. H. (2000) · Analytical Chemistry · doi:10.1021/ac9907235 · Cited by 278
Nguyen, H. P., & Schug, K. A. (2008) · Journal of Separation Science · doi:10.1002/jssc.200700630 · Cited by 275
State-of-the-art in liquid chromatography–mass spectrometry
Niessen, W. M. A. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)00480-x · Cited by 267
Schnier, P. D., Gross, D. S., & Williams, E. R. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00532-3 · Cited by 258
Overcoming Matrix Effects in Liquid Chromatography−Mass Spectrometry
Cappiello, A., Famiglini, G., Palma, P., Pierini, E., Termopoli, V., & Trufelli, H. (2008) · Analytical Chemistry · doi:10.1021/ac8018312 · Cited by 253
Reaction Acceleration in Electrospray Droplets: Size, Distance, and Surfactant Effects
Marsh, B. M., Iyer, K., & Cooks, R. G. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02264-w · Cited by 97
Peptide Correlation Analysis (PeCorA) Reveals Differential Proteoform Regulation
Dermit, M., Peters-Clarke, T. M., Shishkova, E., & Meyer, J. G. (2021) · Journal of Proteome Research · doi:10.1021/acs.jproteome.0c00602 · Cited by 40
Metadata
- Authors
- Tang, L., & Kebarle, P.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1993-12-15
- Volume
- 65
- Issue
- 24
- Pages
- 3654-3668
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2065623041
- Cited by
- 506
- References
- 13
- FWCI
- 7.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.