Nitric Oxide-Releasing Xerogel-Based Fiber-Optic pH Sensors
Open accessAbstract
A xerogel-based optical pH sensor capable of releasing low levels of nitric oxide (NO) and measuring changes in solution pH is reported. Through simple dip-coating procedures, aminoalkoxysilane-based xerogel films modified with N-diazeniumdiolate NO donor precursors and the fluorescent pH indicator seminaphthorhodamine-1 carboxylate (SNARF-1) were sequentially deposited onto optical fibers. The resulting sensors were characterized by fast and linear response to pH throughout the physiological range (pH 7.0-7.8). Real-time chemiluminescence measurements confirmed that the presence of the overlying SNARF-1-containing TMOS layer did not have an inhibitory effect on N-diazeniumdiolate formation or NO release, and the NO-releasing coatings were capable of maintaining NO fluxes >0.4 pmol/cm(2) s up to 16 h. In vitro blood compatibility studies using porcine platelets confirmed the expected thromboresistivity of the NO-releasing xerogel coatings.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
NO releasing intravascular glucose, pH, and CO2 sensors using diazeniumdiolated NO donors demonstrated much improved electrochemical responses over corresponding control sensors.
“Similar to oxygen sensors, NO releasing intravascular glucose,271–275 pH,275,276 and CO2275,277 sensors using diazeniumdiolated NO donors have also been tested, demonstrating much improved electrochemical responses over the corresponding control sensors.”
From Recent advances in thromboresistant and antimicrobial polymers for biomedical applications: just say yes to nitric oxide (NO) (2016) · cites this paper as [276]
Cites
Fiber-Optic Chemical Sensors and Biosensors
Wolfbeis, O. S. (2006) · Analytical Chemistry · doi:10.1021/ac060490z · Cited by 1,629 · see citing works
Hybrid Inorganic-Organic Materials by Sol-Gel Processing of Organofunctional Metal Alkoxides
Schubert, U., Hüsing, N., & Lorenz, A. (1995) · Chemistry of Materials · doi:10.1021/cm00059a007 · Cited by 891 · see citing works
Methods in nitric oxide research
Feelisch, M., & Stamler, J. S. (1996) · Wiley-Blackwell eBooks · Cited by 819 · see citing works
New nitric oxide-releasing zwitterions derived from polyamines
Hrabie, J. A., Klose, J. R., Wink, D. A., & Keefer, L. K. (1993) · The Journal of Organic Chemistry · doi:10.1021/jo00058a030 · Cited by 593 · see citing works
Methods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543 · see citing works
S‐nitroso‐glutathione inhibits platelet activation in vitro and in vivo
Radomski, M. W., Rees, D. D., Noronha-Dutra, A. A., & Moncada, S. (1992) · British Journal of Pharmacology · doi:10.1111/j.1476-5381.1992.tb14517.x · Cited by 326 · see citing works
Fiber-Optic Chemical Sensors and Biosensors
Wolfbeis, O. S. (2004) · Analytical Chemistry · doi:10.1021/ac040049d · Cited by 297 · see citing works
Comparison of mechanically drawn and protection layer chemically etched optical fiber tips
Hoffmann, P., Dutoit, B., & Salathé, R.-P. (1995) · Ultramicroscopy · doi:10.1016/0304-3991(95)00122-0 · Cited by 251 · see citing works
Mowery, K. A., H. Schoenfisch, M., Saavedra, J. E., Keefer, L. K., & Meyerhoff, M. E. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00127-1 · Cited by 219 · see citing works
Self-citationpH optical sensors based on sol–gels: Chemical doping versus covalent immobilization
Lobnik, A., Oehme, I., Steinberg, I. M., & Wolfbeis, O. S. (1998) · Analytica Chimica Acta · doi:10.1016/s0003-2670(97)00708-3 · Cited by 218 · see citing works
Arteriovenous carbon dioxide and pH gradients during cardiac arrest.
GRUNDLER, W. G., Weil, M. H., & Rackow, E. C. (1986) · Circulation · doi:10.1161/01.cir.74.5.1071 · Cited by 190 · see citing works
Sol-gel coatings for optical chemical sensors and biosensors
MacCraith, B. D., McDonagh, C. M., O'Keeffe, G., McEvoy, A. K., Butler, T., & Sheridan, F. R. (1995) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(95)01662-7 · Cited by 187 · see citing works
Arteriovenous Differences in PCO2 and pH are Good Indicators of Critical Hypoperfusion
Zhang, H., & Vincent, J. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/148.4_pt_1.867 · Cited by 157 · see citing works
Implantable chemical sensors for real-time clinical monitoring: progress and challenges
Frost, M. C., & Meyerhoff, M. E. (2002) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(02)00371-x · Cited by 148 · see citing works
Characterisation of sol-gel-derived silica films
McDonagh, C. M., Sheridan, F. R., Butler, T., & MacCraith, B. D. (1996) · Journal of Non-Crystalline Solids · doi:10.1016/0022-3093(95)00488-2 · Cited by 139 · see citing works
Sol−Gel Derived Nitric-Oxide Releasing Materials that Reduce Bacterial Adhesion
Nablo, B. J., Chen, T.-Y., & Schoenfisch, M. H. (2001) · Journal of the American Chemical Society · doi:10.1021/ja0165077 · Cited by 134 · see citing works
Self-citationSchoenfisch, M. H., Mowery, K. A., Rader, M. V., Baliga, N., Wahr, J. A., & Meyerhoff, M. E. (2000) · Analytical Chemistry · doi:10.1021/ac991370c · Cited by 121 · see citing works
Self-citationA sol–gel based fiber optic sensor for local blood pH measurements
Grant, S. A., & Glass, R. S. (1997) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(97)00263-3 · Cited by 121 · see citing works
Zhou, Z., & Meyerhoff, M. E. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.04.046 · Cited by 115 · see citing works
Nivens, D. A. (2002) · Talanta · doi:10.1016/s0039-9140(02)00323-5 · Cited by 115 · see citing works
Organically modified silicate films for stable pH sensors
Makote, R., & Collinson, M. M. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00305-0 · Cited by 115 · see citing works
Preparation of Nitric Oxide (NO)-Releasing Sol−Gels for Biomaterial Applications
Marxer, S. M., Rothrock, A. R., Nablo, B. J., Robbins, M. E., & Schoenfisch, M. H. (2003) · Chemistry of Materials · doi:10.1021/cm034347n · Cited by 104 · see citing works
Self-citationMediation of <i>in vivo</i> glucose sensor inflammatory response via nitric oxide release
Gifford, R., Batchelor, M. M., Lee, Y., Gokulrangan, G., Meyerhoff, M. E., & Wilson, G. S. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30359 · Cited by 96 · see citing works
Frost, M. C., Rudich, S. M., Zhang, H., Maraschio, M., & Meyerhoff, M. E. (2002) · Analytical Chemistry · doi:10.1021/ac025944g · Cited by 93 · see citing works
Stability of new optical pH sensing material based on cross-linked poly(vinyl alcohol) copolymer
Čajlaković, M., Lobnik, A., & Werner, T. (2002) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)01598-7 · Cited by 89 · see citing works
An evanescent wave biosensor. II. Fluorescent signal acquisition from tapered fiber optic probes
Golden, J. P., Anderson, G. P., Rabbany, S. Y., & Ligler, F. S. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.293246 · Cited by 89 · see citing works
Fiber-optic sensors for pH and carbon dioxide using a self-referencing dye
Parker, J. W., Laksin, O., Yu, C., Lau, M. L., Klima, S., Fisher, R., Scott, I. L., & Atwater, B. W. (1993) · Analytical Chemistry · doi:10.1021/ac00065a027 · Cited by 80 · see citing works
Antibacterial properties of nitric oxide–releasing sol‐gels
Nablo, B. J., & Schoenfisch, M. H. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.20030 · Cited by 78 · see citing works
Self-citationEnhanced Fluorescence Sensing Using Sol-Gel Materials
MacCraith, B. D., & McDonagh, C. M. (2002) · Journal of Fluorescence · doi:10.1023/a:1021301723885 · Cited by 74 · see citing works
Nitric Oxide-Releasing Sol−Gel Particle/Polyurethane Glucose Biosensors
Shin, J. H., Marxer, S. M., & Schoenfisch, M. H. (2004) · Analytical Chemistry · doi:10.1021/ac049776z · Cited by 71 · see citing works
Self-citationGanter, M. T., & Zollinger, A. (2003) · British Journal of Anaesthesia · doi:10.1093/bja/aeg176 · Cited by 67 · see citing works
Improving the biocompatibility of in vivo sensors via nitric oxide release
Shin, J. H., & Schoenfisch, M. H. (2006) · The Analyst · doi:10.1039/b600129g · Cited by 66 · see citing works
Self-citationPreparation and characterization of implantable sensors with nitric oxide release coatings
Frost, M. C., Batchelor, M. M., Lee, Y.-M., Zhang, H., Kang, Y., Oh, B. K., Wilson, G. S., Gifford, R., Rudich, S. M., & Meyerhoff, M. E. (2003) · Microchemical Journal · doi:10.1016/s0026-265x(03)00033-x · Cited by 55 · see citing works
Alkali treatment of dye-doped sol–gel glass films for rapid optical pH sensing
Ismail, F., Malins, C., & Goddard, N. J. (2002) · The Analyst · doi:10.1039/b108370h · Cited by 48 · see citing works
Synthesis and Characterization of Nitric Oxide-Releasing Sol−Gel Microarrays
Robbins, M. E., Hopper, E. D., & Schoenfisch, M. H. (2004) · Langmuir · doi:10.1021/la048368n · Cited by 42 · see citing works
Self-citationSánchez-Barragán, I., Costa-Fernandez, J. M., & Sanz‐Medel, A. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.07.038 · Cited by 41 · see citing works
Developments in transcutaneous blood gas monitoring: a review
Rithalia, S. (1991) · Journal of Medical Engineering & Technology · doi:10.3109/03091909109023701 · Cited by 39 · see citing works
Clinical Use of Continuous Arterial Blood Gas Monitoring in the Pediatric Intensive Care Unit
Weiss, I. K., Fink, S., Harrison, R. E., Feldman, J. D., & Brill, J. E. (1999) · PEDIATRICS · doi:10.1542/peds.103.2.440 · Cited by 38 · see citing works
Miniaturized glucose biosensor modified with a nitric oxide-releasing xerogel microarray
Oh, B. K., Robbins, M. E., Nablo, B. J., & Schoenfisch, M. H. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.01.010 · Cited by 36 · see citing works
Self-citationNitric Oxide-Releasing Fluorescence-Based Oxygen Sensing Polymeric Films
Schoenfisch, M. H., Zhang, H., Frost, M. C., & Meyerhoff, M. E. (2002) · Analytical Chemistry · doi:10.1021/ac026075y · Cited by 34 · see citing works
Self-citationOptical chemo- and biosensors for use in clinical applications
Müller, C., Hitzmann, B., Schubert, F., & Scheper, T. H. (1997) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(97)00016-6 · Cited by 32 · see citing works
Continuous Fiberoptic Arterial and Venous Blood Gas Monitoring in Hemorrhagic Shock
Oropello, J. M., Manasia, A. R., Hannon, E. M., Leibowitz, A. B., & Benjamin, E. (1996) · CHEST Journal · doi:10.1378/chest.109.4.1049 · Cited by 31 · see citing works
Continuous intra-arterial blood gas monitoring during oesophagectomy
Ishikawa, S., Makita, K., Nakazawa, K., & Amaha, K. (1998) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03012916 · Cited by 24 · see citing works
Sol–gel derived nitric oxide-releasing oxygen sensors
Marxer, S. M., Robbins, M. E., & Schoenfisch, M. H. (2005) · The Analyst · doi:10.1039/b412079e · Cited by 23 · see citing works
Self-citationDevelopment of a quasi-distributed optical fibre pH sensor using a covalently bound indicator
Wallace, P. A., Elliott, N. J., Uttamlal, M., Holmes‐Smith, A. S., & Campbell, M. C. (2001) · Measurement Science and Technology · doi:10.1088/0957-0233/12/7/323 · Cited by 21 · see citing works
Diffusion of Redox Probes in Hydrated Sol−Gel-Derived Glasses. Effect of Gel Structure
Kanungo, M., & Collinson, M. M. (2003) · Analytical Chemistry · doi:10.1021/ac034658h · Cited by 20 · see citing works
Mulvihill, J. N., & Cazenave, J. (1993) · Springer eBooks · doi:10.1007/978-94-011-1745-6_6 · Cited by 11 · see citing works
Ganter, M. T., Hofer, C. K., Zollinger, A., Spahr, T., Pasch, T., & Zalunardo, M. P. (2004) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2004.07.017 · Cited by 9 · see citing works
Nitric oxide inhibition of platelet deposition on biomaterials.
Ramamurthi, A., & Lewis, R. S. (1999) · PubMed · Cited by 4 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Wo, Y., Brisbois, E. J., Bartlett, R. H., & Meyerhoff, M. E. (2016) · Biomaterials Science · doi:10.1039/c6bm00271d · Cited by 251 · see citing works
Zeolite thin film-coated long period fiber grating sensor for measuring trace organic vapors
Zhang, J., Tang, X., Dong, J., Wei, T., & Xiao, H. (2008) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2008.09.033 · Cited by 68 · see citing works
Wu, Y., & Meyerhoff, M. E. (2008) · Talanta · doi:10.1016/j.talanta.2007.06.022 · Cited by 65 · see citing works
Basic Science Review: Nitric Oxide—Releasing Prosthetic Materials
Varu, V. N., Tsihlis, N. D., & Kibbe, M. R. (2008) · Vascular and Endovascular Surgery · doi:10.1177/1538574408322752 · Cited by 58 · see citing works
Xerogel Optical Sensor Films for Quantitative Detection of Nitroxyl
Dobmeier, K. P., Riccio, D. A., & Schoenfisch, M. H. (2008) · Analytical Chemistry · doi:10.1021/ac702024t · Cited by 46 · see citing works
Self-citationMicro- and nanostructured sol-gel-based materials for optical chemical sensing (2005–2015)
Barczak, M., McDonagh, C. M., & Wencel, D. (2016) · Microchimica Acta · doi:10.1007/s00604-016-1863-y · Cited by 43 · see citing works
Dose controlled nitric oxide-based strategies for antibacterial property in biomedical devices
Mendhi, J., Asgari, M. S., Ratheesh, G., Prasadam, I., Yang, Y., & Xiao, Y. (2020) · Applied Materials Today · doi:10.1016/j.apmt.2020.100562 · Cited by 42 · see citing works
Rhodamine-based ratiometric fluorescent ion-selective bulk optodes
Xie, X., Li, X., Ge, Y., Qin, Y., & Chen, H. (2010) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2010.09.050 · Cited by 27 · see citing works
Nitric oxide release for improving performance of implantable chemical sensors – A review
Cha, K. H., Wang, X., & Meyerhoff, M. E. (2017) · Applied Materials Today · doi:10.1016/j.apmt.2017.10.002 · Cited by 27 · see citing works
Strength of interactions between immobilized dye molecules and sol–gel matrices
Ismail, F., Schoenleber, M., Mansour, R., Bastani, B., Fielden, P. R., & Goddard, N. J. (2010) · The Analyst · doi:10.1039/c0an00149j · Cited by 17 · see citing works
Thionine immobilized in crosslinked chitosan films
Gerbino, L., Riva, J. S., Strumia, M. C., Iglesias, R. A., & Baruzzi, A. M. (2008) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.12.006 · Cited by 14 · see citing works
Zhang, Q., & Meyerhoff, M. E. (2021) · Electroanalysis · doi:10.1002/elan.202100174 · Cited by 11 · see citing works
Mariello, M. (2026) · Advanced Sensor Research · doi:10.1002/adsr.202500111 · Cited by 9 · see citing works
Sol-Gel Environmental Sensors for Preventive Conservation of Cultural Heritage
Villegas, M.-A., Peña-Poza, J., & Heras, M. G. (2018) · Springer eBooks · doi:10.1007/978-3-319-32101-1_139 · Cited by 5 · see citing works
Yung, K. Y., Zhan, Z., Titus, A. H., Baker, G. A., & Bright, F. V. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.05.021 · Cited by 2 · see citing works
Improving the hemocompatibility of catheters via NO release/generation
Wo, Y., Brisbois, E. J., Bartlett, R. H., & Meyerhoff, M. E. (2017) · Elsevier eBooks · doi:10.1016/b978-0-08-100497-5.00013-6 · Cited by 2 · see citing works
Calibration Free and Fluorescein Based Fiber Optic pH Sensor for Clinical Applications
Gauthier‐Manuel, B., Kateklum, R., & Wacogne, B. (2018) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2018.8630296 · Cited by 1 · see citing works
Sol-Gel Environmental Sensors for Preventive Conservation of Cultural Heritage
Villegas, M.-A., Peña-Poza, J., & Heras, M. G. (2016) · Springer eBooks · doi:10.1007/978-3-319-19454-7_139-1 · Cited by 1 · see citing works
Mendhi, J. (2022) · Queensland University of Technology · doi:10.5204/thesis.eprints.227733 · Cited by 1 · see citing works
Simplifying ratiometric C-SNARF-1 pH calibration procedures with a simple post-processing
Kateklum, R., Gauthier‐Manuel, B., Pieralli, C., Mankhetkorn, S., & Wacogne, B. (2017) · HAL
Diazeniumdiolates, Polymeric: Nitric Oxide Donors
Zhang, T., & Zhang, Y. (2016) · Taylor & Francis eBooks · doi:10.1081/e-ebpp-120050808
- Authors
- Dobmeier, K. P., Charville, G. W., & Schoenfisch, M. H.
- Affiliations
- University of North Carolina at Chapel Hill (US)
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-10-07
- Volume
- 78
- Issue
- 21
- Pages
- 7461-7466
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- PMC
- PMC2564808
- OpenAlex
- W1968712331
- Cited by
- 22
- References
- 49
- Citations by year
- 2026: 1 · 2022: 1 · 2021: 1 · 2020: 1 · 2018: 2 · 2017: 4 · 2016: 4 · 2015: 1
- FWCI
- 1.10
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Carolina Digital Repository (University of North Carolina at Chapel Hill) (submittedVersion)
- UNC Libraries
- Funders
- National Science Foundation
- Frances C. and William P. Smallwood Foundation
- National Institutes of Health
- University of North Carolina at Chapel Hill
- National Institute of Biomedical Imaging and Bioengineering (EB 000708, R01EB000708)
- Topics
- Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Fiber Optic Sensors
- Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
- Keywords
- nitric oxide release, fiber optic pH sensor, optical pH sensing, SNARF-1, dip coating, chemiluminescence, platelet aggregation, hemocompatibility
- MeSH terms
- Animals, Benzopyrans, Blood Platelets, Cell Adhesion, Fiber Optic Technology, Fluorescent Dyes, Gels, Hydrogen-Ion Concentration, Microscopy, Electron, Scanning, Naphthols, Nitric Oxide, Rhodamines, Sensitivity and Specificity, Swine, Reproducibility of Results, Optical Fibers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review