Cited by 22Analytical Chemistry and SensorsAdvanced Fiber Optic SensorsMolecular Sensors and Ion Detection

Nitric Oxide-Releasing Xerogel-Based Fiber-Optic pH Sensors

Open access
Dobmeier, Kevin P., Charville, Gregory W., Schoenfisch, Mark H.·2006·Analytical Chemistry

Abstract

A xerogel-based optical pH sensor capable of releasing low levels of nitric oxide (NO) and measuring changes in solution pH is reported. Through simple dip-coating procedures, aminoalkoxysilane-based xerogel films modified with N-diazeniumdiolate NO donor precursors and the fluorescent pH indicator seminaphthorhodamine-1 carboxylate (SNARF-1) were sequentially deposited onto optical fibers. The resulting sensors were characterized by fast and linear response to pH throughout the physiological range (pH 7.0-7.8). Real-time chemiluminescence measurements confirmed that the presence of the overlying SNARF-1-containing TMOS layer did not have an inhibitory effect on N-diazeniumdiolate formation or NO release, and the NO-releasing coatings were capable of maintaining NO fluxes >0.4 pmol/cm(2) s up to 16 h. In vitro blood compatibility studies using porcine platelets confirmed the expected thromboresistivity of the NO-releasing xerogel coatings.

Integrity signals

Registry

Crossref · 10.1021/ac060995p

Cites

49 of 49 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Dobmeier, K. P., Charville, G. W., & Schoenfisch, M. H.
Affiliations
University of North Carolina at Chapel Hill (US)
Venue
Analytical Chemistry
Published
2006-10-07
Volume
78
Issue
21
Pages
7461-7466
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1968712331
Cited by
22
References
49
Citations by year
2026: 1 · 2022: 1 · 2021: 1 · 2020: 1 · 2018: 2 · 2017: 4 · 2016: 4 · 2015: 1
FWCI
1.10
Type
journal article
Language
en
Open access
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
  • Carolina Digital Repository (University of North Carolina at Chapel Hill) (submittedVersion)
  • UNC Libraries
Funders
  • National Science Foundation
  • Frances C. and William P. Smallwood Foundation
  • National Institutes of Health
  • University of North Carolina at Chapel Hill
  • National Institute of Biomedical Imaging and Bioengineering (EB 000708, R01EB000708)
Topics
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Fiber Optic Sensors
  • Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
Keywords
nitric oxide release, fiber optic pH sensor, optical pH sensing, SNARF-1, dip coating, chemiluminescence, platelet aggregation, hemocompatibility
MeSH terms
Animals, Benzopyrans, Blood Platelets, Cell Adhesion, Fiber Optic Technology, Fluorescent Dyes, Gels, Hydrogen-Ion Concentration, Microscopy, Electron, Scanning, Naphthols, Nitric Oxide, Rhodamines, Sensitivity and Specificity, Swine, Reproducibility of Results, Optical Fibers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review