The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Silicon Nanowire Arrays for Label-Free Detection of DNA
Abstract
Arrays of highly ordered n-type silicon nanowires (SiNW) are fabricated using complementary metal-oxide semiconductor (CMOS) compatible technology, and their applications in biosensors are investigated. Peptide nucleic acid (PNA) capture probe-functionalized SiNW arrays show a concentration-dependent resistance change upon hybridization to complementary target DNA that is linear over a large dynamic range with a detection limit of 10 fM. As with other SiNW biosensing devices, the sensing mechanism can be understood in terms of the change in charge density at the SiNW surface after hybridization, the so-called "field effect". The SiNW array biosensor discriminates satisfactorily against mismatched target DNA. It is also able to monitor directly the DNA hybridization event in situ and in real time. The SiNW array biosensor described here is ultrasensitive, non-radioactive, and more importantly, label-free, and is of particular importance to the development of gene expression profiling tools and point-of-care applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hutvágner, G., McLachlan, J., Pasquinelli, A. E., Bálint, E., Tuschl, T., & Zamore, P. D. (2001) · Science · doi:10.1126/science.1062961 · Cited by 2,781
Multiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,436
PNA hybridizes to complementary oligonucleotides obeying the Watson–Crick hydrogen-bonding rules
Egholm, M., Buchardt, O., Christensen, L., Behrens, C., Freier, S. M., Driver, D. A., Berg, R. H., Kim, S. K., Norden, B., & Nielsen, P. E. (1993) · Nature · doi:10.1038/365566a0 · Cited by 2,079
Hahm, J.-I., & Lieber, C. M. (2004) · Nano Letters · doi:10.1021/nl034853b · Cited by 1,308
Electrical detection of single viruses
Patolsky, F., Zheng, G., Hayden, O., Lakadamyali, M., Zhuang, X., & Lieber, C. M. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406159101 · Cited by 1,258
Patolsky, F., Zheng, G., & Lieber, C. M. (2006) · Analytical Chemistry · doi:10.1021/ac069419j · Cited by 710
Reliability and reproducibility issues in DNA microarray measurements
DRAGHICI, S., KHATRI, P., EKLUND, A., & SZALLASI, Z. (2006) · Trends in Genetics · doi:10.1016/j.tig.2005.12.005 · Cited by 590
Performance limits of nanobiosensors
Nair, P. R., & Alam, M. A. (2006) · Applied Physics Letters · doi:10.1063/1.2211310 · Cited by 341
Endo, T., Kerman, K., Nagatani, N., Takamura, Y., & Tamiya, E. (2005) · Analytical Chemistry · doi:10.1021/ac0513459 · Cited by 313
A structural state of the myosin V motor without bound nucleotide
Coureux, P.-D., Wells, A. L., Ménétrey, J., Yengo, C. M., Morris, C. A., Sweeney, H. L., & Houdusse, A. (2003) · Nature · doi:10.1038/nature01927 · Cited by 303
Cited by
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
Diverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
DNA Biosensors and Microarrays
Sassolas, A., Leca-Bouvier, B. D., & Blum, L. J. (2008) · Chemical Reviews · doi:10.1021/cr0684467 · Cited by 1,246
Importance of the Debye Screening Length on Nanowire Field Effect Transistor Sensors
Stern, E., Wagner, R., Sigworth, F. J., Breaker, R., Fahmy, T. M., & Reed, M. A. (2007) · Nano Letters · doi:10.1021/nl071792z · Cited by 806
Electrochemistry of Nucleic Acids
Paleček, E., & Bartošík, M. (2012) · Chemical Reviews · doi:10.1021/cr200303p · Cited by 668
Tissue–electronics interfaces: from implantable devices to engineered tissues
Feiner, R., & Dvir, T. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.76 · Cited by 595
TELES, F., & FONSECA, L. (2008) · Talanta · doi:10.1016/j.talanta.2008.07.024 · Cited by 405
Ramgir, N. S., Yang, Y., & Zacharias, M. (2010) · Small · doi:10.1002/smll.201000972 · Cited by 383
Structure, Synthesis, and Applications of TiO2 Nanobelts
Zhao, Z., Tian, J., Sang, Y., Cabot, A., & Liu, H. (2015) · Advanced Materials · doi:10.1002/adma.201405589 · Cited by 342
Nucleic Acid Conjugated Nanomaterials for Enhanced Molecular Recognition
Wang, H., Yang, R., Yang, L., & Tan, W. (2009) · ACS Nano · doi:10.1021/nn9006303 · Cited by 329
Silicon nanowires for advanced energy conversion and storage
Peng, K.-Q., Wang, X., Li, L., Hu, Y., & Lee, S.-T. (2013) · Nano Today · doi:10.1016/j.nantod.2012.12.009 · Cited by 298
Review—Field-Effect Transistor Biosensing: Devices and Clinical Applications
Syu, Y.-C., Hsu, W.-E., & Lin, C.-T. (2018) · ECS Journal of Solid State Science and Technology · doi:10.1149/2.0291807jss · Cited by 284
DNA Sensing by Silicon Nanowire: Charge Layer Distance Dependence
Zhang, G.-J., Zhang, G., Chua, J. H., Chee, R.-E., Wong, E. H., Agarwal, A., Buddharaju, K. D., Singh, N., Gao, Z., & Balasubramanian, N. (2008) · Nano Letters · doi:10.1021/nl072991l · Cited by 278
Self-citationMicrofluidic-based biosensors toward point-of-care detection of nucleic acids and proteins
Choi, S., Goryll, M., Sin, L. Y. M., Wong, P. K., & Chae, J. (2011) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0638-8 · Cited by 270
Silicon nanowire biosensor and its applications in disease diagnostics: A review
Zhang, G.-J., & Ning, Y. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.08.035 · Cited by 268
Chua, J. H., Chee, R.-E., Agarwal, A., Wong, S. M., & Zhang, G.-J. (2009) · Analytical Chemistry · doi:10.1021/ac901157x · Cited by 266
Self-citationLabel-free direct detection of MiRNAs with silicon nanowire biosensors
Zhang, G.-J., Chua, J. H., Chee, R.-E., Agarwal, A., & Wong, S. M. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.12.035 · Cited by 265
Self-citationSilicon nanowire biosensor for highly sensitive and rapid detection of Dengue virus
Zhang, G.-J., Zhang, L., Huang, M. J., Luo, Z. H. H., Tay, G. K. I., Lim, E.-J. A., Kang, T. G., & Chen, Y. (2010) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2010.02.021 · Cited by 258
Effect of Nanowire Number, Diameter, and Doping Density on Nano-FET Biosensor Sensitivity
Li, J., Zhang, Y., To, S., You, L., & Sun, Y. (2011) · ACS Nano · doi:10.1021/nn202182p · Cited by 138
Klinghammer, S., Voitsekhivska, T., Licciardello, N., Kim, K., Baek, C.-K., Cho, H., Wolter, K.-J., Kirschbaum, C., Baraban, L., & Cuniberti, G. (2020) · ACS Sensors · doi:10.1021/acssensors.0c02267 · Cited by 62
BioFET Technology: Aggressively Scaled pMOS FinFET as Biosensor
Martens, K., Santermans, S., Gupta, M., Hellings, G., Wuytens, R., Du Bois, B., Dupuy, E., Altamirano-Sanchez, E., Jans, K., Vos, R., et al. (2019) · 2019 IEEE International Electron Devices Meeting (IEDM) · doi:10.1109/iedm19573.2019.8993589 · Cited by 14
Metadata
- Authors
- Gao, Z., Agarwal, A., Trigg, A. D., Singh, N., Fang, C., Tung, C.-H., Fan, Y., Buddharaju, K. D., & Kong, J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-04-04
- Volume
- 79
- Issue
- 9
- Pages
- 3291-3297
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2089776731
- Cited by
- 430
- References
- 17
- FWCI
- 27.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.