The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Development of Ultrabright Semiconducting Polymer Dots for Ratiometric pH Sensing
Open accessAbstract
Semiconducting polymer-based nanoparticles (Pdots) have recently emerged as a new class of ultrabright probes for biological detection and imaging. This paper describes the development of poly(2,5-di(3',7'-dimethyloctyl)phenylene-1,4-ethynylene) (PPE) Pdots as a platform for designing Förster resonance energy transfer (FRET)-based ratiometric pH nanoprobes. We describe and compare three routes for coupling the pH-sensitive dye, fluorescein, to PPE Pdots, which is a pH-insensitive semiconducting polymer. This approach offers a rapid and robust sensor for pH determination using the ratiometric methodology where excitation at a single wavelength results in two emission peaks, one that is pH sensitive and the other one that is pH insensitive for use as an internal reference. The linear range for pH sensing of the fluorescein-coupled Pdots is between pH 5.0 and 8.0, which is suitable for most cellular studies. The pH-sensitive Pdots show excellent reversibility and stability in pH measurements. In this paper, we use them to measure the intracellular pH in HeLa cells following their uptake by endocytosis, thus demonstrating their utility for use in cellular and imaging experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantum Dots for Live Cells, in Vivo Imaging, and Diagnostics
Michalet, X., Pinaud, F. F., Bentolila, L. A., Tsay, J. M., Doose, S., Li, J. J., Sundaresan, G., Wu, A. M., Gambhir, S. S., & Weiss, S. (2005) · Science · doi:10.1126/science.1104274 · Cited by 7,790
Quantum dot bioconjugates for imaging, labelling and sensing
Medintz, I. L., Uyeda, H. T., Goldman, E. R., & Mattoussi, H. (2005) · Nature Materials · doi:10.1038/nmat1390 · Cited by 6,229
Probing the Cytotoxicity of Semiconductor Quantum Dots
Derfus, A. M., Chan, W. C. W., & Bhatia, S. N. (2004) · Nano Letters · doi:10.1021/nl0347334 · Cited by 3,391
Fluorescent Indicators for Intracellular pH
Han, J., & Burgess, K. (2010) · Chemical Reviews · doi:10.1021/cr900249z · Cited by 1,620
Gene Regulation at the Single-Cell Level
Rosenfeld, N., Young, J. W., Alon, U., Swain, P. S., & Elowitz, M. B. (2005) · Science · doi:10.1126/science.1106914 · Cited by 1,104
Absorption and fluorescence properties of fluorescein
Sjöback, R., Nygren, J., & Kubista, M. (1995) · Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · doi:10.1016/0584-8539(95)01421-p · Cited by 1,069
Burns, A., Ow, H., & Wiesner, U. (2006) · Chem. Soc. Rev. · doi:10.1039/b600562b · Cited by 849
Multicolor Conjugated Polymer Dots for Biological Fluorescence Imaging
Wu, C., Bull, B., Szymanski, C., Christensen, K., & McNeill, J. (2008) · ACS Nano · doi:10.1021/nn800590n · Cited by 724
Self-citationNanoparticles of Conjugated Polymers
Pecher, J., & Mecking, S. (2010) · Chemical Reviews · doi:10.1021/cr100132y · Cited by 715
Phagosome maturation: aging gracefully
VIEIRA, O. V., BOTELHO, R. J., & GRINSTEIN, S. (2002) · Biochemical Journal · doi:10.1042/bj20020691 · Cited by 686
Cited by
An overview of nanoparticles commonly used in fluorescent bioimaging
Wolfbeis, O. S. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00392f · Cited by 1,631
Highly Fluorescent Semiconducting Polymer Dots for Biology and Medicine
Wu, C., & Chiu, D. T. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201205133 · Cited by 1,101
Self-citationPolymer-encapsulated organic nanoparticles for fluorescence and photoacoustic imaging
Li, K., & Liu, B. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00014e · Cited by 987
Nie, H., Li, M., Li, Q., Liang, S., Tan, Y., Sheng, L., Shi, W., & Zhang, S. X.-A. (2014) · Chemistry of Materials · doi:10.1021/cm5003669 · Cited by 955
Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Wencel, D., Abel, T., & McDonagh, C. (2014) · Analytical Chemistry · doi:10.1021/ac4035168 · Cited by 541
Li, J., Rao, J., & Pu, K. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2017.11.025 · Cited by 469
Shi, W., Li, X., & Ma, H. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201202533 · Cited by 468
Soft fluorescent nanomaterials for biological and biomedical imaging
Peng, H.-S., & Chiu, D. T. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00294f · Cited by 407
Self-citationPhotostable Ratiometric Pdot Probe for in Vitro and in Vivo Imaging of Hypochlorous Acid
Wu, L., Wu, I.-C., DuFort, C. C., Carlson, M. A., Wu, X., Chen, L., Kuo, C.-T., Qin, Y., Yu, J., Hingorani, S. R., et al. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.7b01545 · Cited by 349
Self-citationYu, J., Rong, Y., Kuo, C.-T., Zhou, X.-H., & Chiu, D. T. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04672 · Cited by 262
Self-citationFluorescent Conjugated Polyelectrolytes for Bioimaging
Pu, K., & Liu, B. (2011) · Advanced Functional Materials · doi:10.1002/adfm.201101153 · Cited by 257
Liu, H.-Y., Wu, P.-J., Kuo, S.-Y., Chen, C.-P., Chang, E.-H., Wu, C.-Y., & Chan, Y.-H. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b06710 · Cited by 181
Self-citationHighly luminescent, fluorinated semiconducting polymer dots for cellular imaging and analysis
Zhang, Y., Yu, J., Gallina, M. E., Sun, W., Rong, Y., & Chiu, D. T. (2013) · Chemical Communications · doi:10.1039/c3cc44048f · Cited by 48
Self-citation
Metadata
- Authors
- Chan, Y.-H., Wu, C., Ye, F., Jin, Y., Smith, P. B., & Chiu, D. T.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-01-18
- Volume
- 83
- Issue
- 4
- Pages
- 1448-1455
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1999164175
- Cited by
- 258
- References
- 37
- FWCI
- 16.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.