Sprouting Angiogenesis under a Chemical Gradient Regulated by Interactions with an Endothelial Monolayer in a Microfluidic Platform
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Microfluidic cell culture assays are versatile tools for studying cell migration, particularly angiogenesis. Such assays can deliver precisely controlled linear gradients of chemical stimuli to cultured cells in a microfluidic channel, offering excellent optical resolution and in situ monitoring of cellular morphogenesis in response to a gradient. Microfluidic cell culture assays provide a chemical gradient subject to molecular diffusion, although cellular metabolism can perturb it. The actual gradient perturbed by cells has not been precisely described in the context of regulated cellular morphogenesis. We modeled the chemical gradient in a microfluidic channel by simulating the analyte(VEGF) distribution during cellular interactions. The results were experimentally verified by monitoring sprouting angiogenic response from a monolayer of human umbilical vein endothelial cells (hUVECs) into a type 1 collagen scaffold. The simulation provided a basis for understanding a real distribution of the analyte interrupted by cells in microfluidic device. The new protocol enables one to quantify the morphogenesis of hUVECs under a flat, less-steep, or steep gradient.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Angiogenesis as a therapeutic target
Ferrara, N., & Kerbel, R. S. (2005) · Nature · doi:10.1038/nature04483 · Cited by 2,653
Modeling Tissue Morphogenesis and Cancer in 3D
Yamada, K. M., & Cukierman, E. (2007) · Cell · doi:10.1016/j.cell.2007.08.006 · Cited by 1,751
Folkman, J. (2006) · Annual Review of Medicine · doi:10.1146/annurev.med.57.121304.131306 · Cited by 1,209
Endothelial cells and VEGF in vascular development
Coultas, L., Chawengsaksophak, K., & Rossant, J. (2005) · Nature · doi:10.1038/nature04479 · Cited by 1,016
Interstitial flow influences direction of tumor cell migration through competing mechanisms
Polacheck, W. J., Charest, J. L., & Kamm, R. D. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1103581108 · Cited by 509
Self-citationA novel 3D mammalian cell perfusion-culture system in microfluidic channels
Toh, Y.-C., Zhang, C., Zhang, J., Khong, Y. M., Chang, S., Samper, V. D., van Noort, D., Hutmacher, D. W., & Yu, H. (2007) · Lab on a Chip · doi:10.1039/b614872g · Cited by 414
Engineering microscale cellular niches for three-dimensional multicellular co-cultures
Huang, C. P., Lu, J., Seon, H., Lee, A. P., Flanagan, L. A., Kim, H.-Y., Putnam, A. J., & Jeon, N. L. (2009) · Lab on a Chip · doi:10.1039/b818401a · Cited by 384
A gel-free 3D microfluidic cell culture system
Ong, S.-M., Zhang, C., Toh, Y.-C., Kim, S. H., Foo, H. L., Tan, C. H., van Noort, D., Park, S., & Yu, H. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.022 · Cited by 172
A microfluidic platform for 3-dimensional cell culture and cell-based assays
Kim, M. S., Yeon, J. H., & Park, J.-K. (2007) · Biomedical Microdevices · doi:10.1007/s10544-006-9016-4 · Cited by 166
Cited by
Microfluidic assay for simultaneous culture of multiple cell types on surfaces or within hydrogels
Shin, Y., Han, S., Jeon, J. S., Yamamoto, K., Zervantonakis, I. K., Sudo, R., Kamm, R. D., & Chung, S. (2012) · Nature Protocols · doi:10.1038/nprot.2012.051 · Cited by 617
Self-citationHydrogels as Drug Delivery Systems: A Review of Current Characterization and Evaluation Techniques
Vigata, M., Meinert, C., Hutmacher, D. W., & Bock, N. (2020) · Pharmaceutics · doi:10.3390/pharmaceutics12121188 · Cited by 544
Concentration gradient generation methods based on microfluidic systems
Wang, X., Liu, Z., & Pang, Y. (2017) · RSC Advances · doi:10.1039/c7ra04494a · Cited by 219
Tumour-on-a-chip: microfluidic models of tumour morphology, growth and microenvironment
Tsai, H.-F., Trubelja, A., Shen, A. Q., & Bao, G. (2017) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0137 · Cited by 214
Digital Light Processing Based Bioprinting with Composable Gradients
Wang, M., Li, W., Mille, L. S., Ching, T., Luo, Z., Tang, G., Garciamendez, C. E., Lesha, A., Hashimoto, M., & Zhang, Y. S. (2022) · Advanced Materials · doi:10.1002/adma.202107038 · Cited by 206
Metadata
- Authors
- Jeong, G. S., Han, S., Shin, Y., Kwon, G. H., Kamm, R. D., Lee, S.-H., & Chung, S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-10-28
- Volume
- 83
- Issue
- 22
- Pages
- 8454-8459
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2316787772
- Cited by
- 117
- References
- 9
- FWCI
- 4.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.