The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Comparison of Biocompatibility and Adsorption Properties of Different Plastics for Advanced Microfluidic Cell and Tissue Culture Models
Abstract
Microfluidic technology is providing new routes toward advanced cell and tissue culture models to better understand human biology and disease. Many advanced devices have been made from poly(dimethylsiloxane) (PDMS) to enable experiments, for example, to study drug metabolism by use of precision-cut liver slices, that are not possible with conventional systems. However, PDMS, a silicone rubber material, is very hydrophobic and tends to exhibit significant adsorption and absorption of hydrophobic drugs and their metabolites. Although glass could be used as an alternative, thermoplastics are better from a cost and fabrication perspective. Thermoplastic polymers (plastics) allow easy surface treatment and are generally transparent and biocompatible. This study focuses on the fabrication of biocompatible microfluidic devices with low adsorption properties from the thermoplastics poly(methyl methacrylate) (PMMA), polystyrene (PS), polycarbonate (PC), and cyclic olefin copolymer (COC) as alternatives for PDMS devices. Thermoplastic surfaces were oxidized using UV-generated ozone or oxygen plasma to reduce adsorption of hydrophobic compounds. Surface hydrophilicity was assessed over 4 weeks by measuring the contact angle of water on the surface. The adsorption of 7-ethoxycoumarin, testosterone, and their metabolites was also determined after UV-ozone treatment. Biocompatibility was assessed by culturing human hepatoma (HepG2) cells on treated surfaces. Comparison of the adsorption properties and biocompatibility of devices in different plastics revealed that only UV-ozone-treated PC and COC devices satisfied both criteria. This paper lays an important foundation that will help researchers make informed decisions with respect to the materials they select for microfluidic cell-based culture experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Lab-on-a-chip: microfluidics in drug discovery
Dittrich, P. S., & Manz, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd1985 · Cited by 1,844
PDMS absorption of small molecules and consequences in microfluidic applications
Toepke, M. W., & Beebe, D. J. (2006) · Lab on a Chip · doi:10.1039/b612140c · Cited by 1,190
Friess, W. (1998) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/s0939-6411(98)00017-4 · Cited by 1,130
Recent developments in PDMS surface modification for microfluidic devices
Zhou, J., Ellis, A. V., & Voelcker, N. H. (2010) · ELECTROPHORESIS · doi:10.1002/elps.200900475 · Cited by 857
Biological implications of polydimethylsiloxane-based microfluidic cell culture
Regehr, K. J., Domenech, M., Koepsel, J. T., Carver, K. C., Ellison-Zelski, S. J., Murphy, W. L., Schuler, L. A., Alarid, E. T., & Beebe, D. J. (2009) · Lab on a Chip · doi:10.1039/b903043c · Cited by 719
Bonding of thermoplastic polymer microfluidics
Tsao, C.-W., & DeVoe, D. L. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-008-0361-x · Cited by 601
Lee, P. J., Hung, P. J., & Lee, L. P. (2007) · Biotechnology and Bioengineering · doi:10.1002/bit.21360 · Cited by 509
The autofluorescence of plastic materials and chips measured under laser irradiation
Piruska, A., Nikcevic, I., Lee, S. H., Ahn, C., Heineman, W. R., Limbach, P. A., & Seliskar, C. J. (2005) · Lab on a Chip · doi:10.1039/b508288a · Cited by 431
Cell Culture Models in Microfluidic Systems
Meyvantsson, I., & Beebe, D. J. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.113042 · Cited by 345
Cell Culture in 3-Dimensional Microfluidic Structure of PDMS (polydimethylsiloxane)
Leclerc, E., Sakai, Y., & Fujii, T. (2003) · Biomedical Microdevices · doi:10.1023/a:1024583026925 · Cited by 324
UV/ozone modification of poly(dimethylsiloxane) microfluidic channels
Berdichevsky, Y., Khandurina, J., Guttman, A., & Lo, Y.-H. (2004) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2003.09.022 · Cited by 318
Oláh, A., Hillborg, H., & Vancso, G. J. (2005) · Applied Surface Science · doi:10.1016/j.apsusc.2004.06.005 · Cited by 313
Bokhari, M., Carnachan, R. J., Cameron, N. R., & Przyborski, S. A. (2007) · Journal of Anatomy · doi:10.1111/j.1469-7580.2007.00778.x · Cited by 227
Hydrophobic Recovery of Polydimethylsiloxane Elastomer Exposed to Partial Electrical Discharge
Kim, J., Chaudhury, M. K., & Owen, M. J. (2000) · Journal of Colloid and Interface Science · doi:10.1006/jcis.2000.6817 · Cited by 213
van Midwoud, P. M., Merema, M. T., Verpoorte, E., & Groothuis, G. M. M. (2010) · Lab on a Chip · doi:10.1039/c0lc00043d · Cited by 203
Self-citationRapid Prototyping of Arrayed Microfluidic Systems in Polystyrene for Cell-Based Assays
Young, E. W. K., Berthier, E., Guckenberger, D. J., Sackmann, E., Lamers, C., Meyvantsson, I., Huttenlocher, A., & Beebe, D. J. (2011) · Analytical Chemistry · doi:10.1021/ac102897h · Cited by 172
Adaptation of plastic surfaces for tissue culture by glow discharge
Amstein, C. F., & Hartman, P. A. (1975) · Journal of Clinical Microbiology · doi:10.1128/jcm.2.1.46-54.1975 · Cited by 143
van Midwoud, P. M., Groothuis, G. M. M., Merema, M. T., & Verpoorte, E. M. J. (2009) · Biotechnology and Bioengineering · doi:10.1002/bit.22516 · Cited by 139
Self-citationHot embossing for fabrication of a microfluidic 3D cell culture platform
Jeon, J. S., Chung, S. H., Kamm, R. D., & Charest, J. L. (2010) · Biomedical Microdevices · doi:10.1007/s10544-010-9496-0 · Cited by 119
Hard Top Soft Bottom Microfluidic Devices for Cell Culture and Chemical Analysis
Mehta, G., Lee, J. S.-J., Cha, W., Tung, Y., Linderman, J. J., & Takayama, S. (2009) · Analytical Chemistry · doi:10.1021/ac802178u · Cited by 111
Hydrophobic recovery of oxygen-plasma-treated polystyrene
Occhiello, E., Morra, M., Cinquina, P., & Garbassi, F. (1992) · Polymer · doi:10.1016/0032-3861(92)90088-e · Cited by 104
Technique for the control of spheroid diameter using microfabricated chips
Sakai, Y., & Nakazawa, K. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.06.004 · Cited by 94
UV-Based Patterning of Polymeric Substrates for Cell Culture Applications
Welle, A., & Gottwald, E. (2002) · Biomedical Microdevices · doi:10.1023/a:1014267712144 · Cited by 89
Cell transport via electromigration in polymer-based microfluidic devices
Witek, M. A., Wei, S., Vaidya, B., Adams, A. A., Zhu, L., Stryjewski, W. J., McCarley, R. L., & Soper, S. A. (2004) · Lab on a Chip · doi:10.1039/b317093d · Cited by 48
On-line HPLC Analysis System for Metabolism and Inhibition Studies in Precision-Cut Liver Slices
van Midwoud, P. M., Janssen, J., Merema, M. T., de Graaf, I. A. M., Groothuis, G. M. M., & Verpoorte, E. M. J. (2010) · Analytical Chemistry · doi:10.1021/ac1018638 · Cited by 40
Self-citationAltmann, B., Giselbrecht, S., Weibezahn, K. F., Welle, A., & Gottwald, E. (2008) · Biomedical Materials · doi:10.1088/1748-6041/3/3/034120 · Cited by 33
Microfluidics Enables Small-Scale Tissue-Based Drug Metabolism Studies with Scarce Human Tissue
van Midwoud, P. M., Merema, M. T., Verpoorte, E. M. J., & Groothuis, G. M. M. (2011) · JALA Journal of the Association for Laboratory Automation · doi:10.1016/j.jala.2011.07.003 · Cited by 32
Self-citation
Cited by
Organs-on-chips at the frontiers of drug discovery
Esch, E. W., Bahinski, A., & Huh, D. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4539 · Cited by 1,185
Advantages and challenges of microfluidic cell culture in polydimethylsiloxane devices
Halldorsson, S., Lucumi, E., Gómez-Sjöberg, R., & Fleming, R. M. T. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.029 · Cited by 1,027
Modelling cancer in microfluidic human organs-on-chips
Sontheimer-Phelps, A., Hassell, B. A., & Ingber, D. E. (2019) · Nature Reviews Cancer · doi:10.1038/s41568-018-0104-6 · Cited by 906
Interconnected Microphysiological Systems for Quantitative Biology and Pharmacology Studies
Edington, C. D., Chen, W. L. K., Geishecker, E., Kassis, T., Soenksen, L. R., Bhushan, B. M., Freake, D., Kirschner, J., Maass, C., Tsamandouras, N., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-22749-0 · Cited by 487
Tsao, C.-W. (2016) · Micromachines · doi:10.3390/mi7120225 · Cited by 367
Metadata
- Authors
- van Midwoud, P. M., Janse, A., Merema, M. T., Groothuis, G. M. M., & Verpoorte, E.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-04-11
- Volume
- 84
- Issue
- 9
- Pages
- 3938-3944
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1974663770
- Cited by
- 274
- References
- 28
- FWCI
- 7.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.