Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
The present work describes the first example of real-time noninvasive lactate sensing in human perspiration during exercise events using a flexible printed temporary-transfer tattoo electrochemical biosensor that conforms to the wearer's skin. The new skin-worn enzymatic biosensor exhibits chemical selectivity toward lactate with linearity up to 20 mM and demonstrates resiliency against continuous mechanical deformation expected from epidermal wear. The device was applied successfully to human subjects for real-time continuous monitoring of sweat lactate dynamics during prolonged cycling exercise. The resulting temporal lactate profiles reflect changes in the production of sweat lactate upon varying the exercise intensity. Such skin-worn metabolite biosensors could lead to useful insights into physical performance and overall physiological status, hence offering considerable promise for diverse sport, military, and biomedical applications.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Previously reported sweat-based and other non-invasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state14–18.”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [15]
In the citing paper
“For this reason, most wearable sweat sensors have focused on exercise, thermal, or chemically stimulated sweat produced at rates of 10’s or 100’s of nL min−1 cm−2 or higher10–23.”
From A wearable patch for continuous analysis of thermoregulatory sweat at rest (2021) · cites this paper as [15]
In the citing paper
“They are unable to draw low volumes of resting sweat rapidly into the device, limiting real-time assessment.”
From A wearable patch for continuous analysis of thermoregulatory sweat at rest (2021) · cites this paper as [15]
In the citing paper
“However, the secretion mechanism of lactic acid into sweat is complex and still unclear 79 .”
From A review of sampling, energy supply and intelligent monitoring for long-term sweat sensors (2022) · cites this paper as [79]
In the citing paper
“Although sweat lactate does not directly reflect the concurrent blood levels, it indicates the level of physical exertion experienced during prolonged exercise and can be used as a marker for athletic efficiency without invasive blood sampling.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [58]
4 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Biochemistry of exercise-induced metabolic acidosis
Robergs, R. A., Ghiasvand, F., & Parker, D. (2004) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00114.2004 · Cited by 1,304
Wireless sensor networks for personal health monitoring: Issues and an implementation
Milenković, A., Otto, C., & Jovanov, E. (2006) · Computer Communications · doi:10.1016/j.comcom.2006.02.011 · Cited by 1,023
Blood Lactate Measurements and Analysis during Exercise: A Guide for Clinicians
Goodwin, M. L., Harris, J. E., Hernández, A., & Gladden, L. B. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100414 · Cited by 554
Lactate Kinetics and Individual Anaerobic Threshold*
Stegmann, H., Kindermann, W., & Schnabel, A. (1981) · International Journal of Sports Medicine · doi:10.1055/s-2008-1034604 · Cited by 499
Tattoo-based potentiometric ion-selective sensors for epidermal pH monitoring
Bandodkar, A. J., Hung, V. W. S., Jia, W., Valdés-Ramírez, G., Windmiller, J. R., Martinez, A. G., Ramírez, J., Chan, G., Kerman, K., & Wang, J. (2013) · The Analyst · doi:10.1039/c2an36422k · Cited by 379
Self-citationKhodagholy, D., Curto, V. F., Fraser, K. J., Gurfinkel, M., Byrne, R., Diamond, D., Malliaras, G. G., Benito-Lopez, F., & Owens, R. M. (2012) · Journal of Materials Chemistry · doi:10.1039/c2jm15716k · Cited by 303
Formulation and stability of a novel artificial human sweat under conditions of storage and use
Harvey, C. J., LeBouf, R. F., & Stefaniak, A. B. (2010) · Toxicology in Vitro · doi:10.1016/j.tiv.2010.06.016 · Cited by 274
Strain Sensing Fabric for Hand Posture and Gesture Monitoring
Lorussi, F., Scilingo, E. P., Tesconi, M., Tognetti, A., & DeRossi, D. (2005) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.854510 · Cited by 207
Blood lactate parameters related to aerobic capacity and endurance performance
Yoshida, T., Chida, M., Ichioka, M., & Suda, Y. (1987) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00696368 · Cited by 183
Research works printed but not linked: 3
- Chiarugi F., 2008, Comput. Cardiol., 35, 901
- Pilardeau P. A., 1988, J. Sports Med. Phys. Fit., 28, 247
- Polliack A., 1997, J. Rehabil. Res. Develop., 34, 303
Cited by
Items 501–600 of 861
Boukherroub, R., & Szunerits, S. (2024) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061622-012029 · Cited by 23
Ma, H., Tian, Y., Jiao, A., Wang, C., Zhang, M., Zheng, L., Li, S., & Chen, M. (2021) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2021.103330 · Cited by 22
Flexible cotton-AuNP thread electrode for non-enzymatic sensor of uric acid in urine
Teekayupak, K., Ruecha, N., Chailapakul, O., & Rodthongkum, N. (2021) · Cellulose · doi:10.1007/s10570-021-04169-y · Cited by 23
Amperometric Measurements by a Novel Aerosol Jet Printed Flexible Sensor for Wearable Applications
Tonello, S., Fapanni, T., Bonaldo, S., Giorgi, G., Narduzzi, C., Paccagnella, A., Serpelloni, M., Sardini, E., & Carrara, S. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3225014 · Cited by 21
Wearable sensors for monitoring vital signals in sports and health: progress and perspective
Zhao, J., Feng, S., Cao, X., & Zheng, H. (2024) · Sensor Review · doi:10.1108/sr-02-2024-0080 · Cited by 23
Kwon, J., Park, H. W., Park, Y.-B., & Kim, N. (2017) · International Journal of Precision Engineering and Manufacturing-Green Technology · doi:10.1007/s40684-017-0039-5 · Cited by 21
Duffy, E., Guzman, K. D., Wallace, R., Murphy, R. P., & Morrin, A. (2017) · Cosmetics · doi:10.3390/cosmetics4040044 · Cited by 25
Development of Enzymatic Sensors Based on Extended-gate-type Organic Field-effect Transistors
Minami, T., Minamiki, T., & Sasaki, Y. (2018) · Electrochemistry · doi:10.5796/electrochemistry.18-6-e2672 · Cited by 22
Ohashi, T., Gerrett, N., Shinkawa, S., Satō, T., Miyake, R., Kondo, N., & Mitsuzawa, S. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c03466 · Cited by 23
Gao, R., Khatib, M., & Bao, Z. (2026) · npj Biosensing · doi:10.1038/s44328-025-00065-8 · Cited by 22
Wearable biosensors and sample handling strategies
Parlak, O., Curto, V. F., Ojeda, E., Basabe‐Desmonts, L., Benito‐Lopez, F., & Salleo, A. (2020) · Elsevier eBooks · doi:10.1016/b978-0-08-102407-2.00004-7 · Cited by 23
Rajarathinam, T., Kim, S., Thirumalai, D., Lee, S. J., Kwon, M., Paik, H., Kim, S., & Chang, S. (2021) · Biosensors · doi:10.3390/bios11110439 · Cited by 20
Eissa, S., AlKattan, K. M., & Zourob, M. M. (2021) · ACS Omega · doi:10.1021/acsomega.1c04849 · Cited by 21
Shitanda, I., Oshimoto, T., Loew, N., Motosuke, M., Watanabe, H., Mikawa, T., & Itagaki, M. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115555 · Cited by 22
Ma, J., Li, H., Anwer, S., Umer, W., Antwi‐Afari, M. F., & Xiao, E. B. (2024) · International Journal of Occupational Safety and Ergonomics · doi:10.1080/10803548.2024.2330242 · Cited by 21
Flexible substrate sensors for multiplex biomarker monitoring
Brennan, D., & Galvin, P. (2018) · MRS Communications · doi:10.1557/mrc.2018.134 · Cited by 20
Towards self-powered and autonomous wearable glucose sensor
Ghoreishizadeh, S. S., Moschou, D. C., McBay, D., Gonzalez-Solino, C., Dutta, G., Lorenzo, M. D., & Soltan, A. (2018) · IEEE International Conference on Electronics, Circuits and Systems (ICECS) · doi:10.1109/icecs.2018.8618022 · Cited by 20
Towards a sweat-based wireless and wearable electrochemical sensor
Dieffenderfer, J. P., Wilkins, M. D., Hood, C., Beppler, E. C., Daniele, M. A.-A., & Bozkurt, A. Y. (2016) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2016.7808470 · Cited by 24
Chung, D., & Gray, B. L. (2019) · Journal of The Electrochemical Society · doi:10.1149/2.0191909jes · Cited by 19
Detection of C-Reactive Protein Using a Flexible Biosensor with Improved Bending Life
Takaloo, S., Zand, M. M., Kalantar, M., & Rezayan, A. H. (2023) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/acd1bc · Cited by 21
Application of Intelligent Medical Sensing Technology
Fu, J., Gao, Q., & Li, S. (2023) · Biosensors · doi:10.3390/bios13080812 · Cited by 21
Non-invasive Biodiversified Sensors: A Modernized Screening Technology for Cancer
Takke, A., & Shende, P. K. (2019) · Current Pharmaceutical Design · doi:10.2174/1381612825666191022162232 · Cited by 20
Cuniberto, E., Alharbi, A., Wu, T., Huang, Z., Sardashti, K., You, K.-D., Kisslinger, K., Taniguchi, T., Watanabe, K., Kiani, R., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-66408-9 · Cited by 20
Xu, G., Yuan, L., Chen, X., Jia, W., Wang, M., Yang, L., Zhu, J., & Cheng, H. (2021) · Materials & Design · doi:10.1016/j.matdes.2021.109721 · Cited by 20
Self-citationLenar, N., & Paczosa‐Bator, B. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms26115001 · Cited by 22
Paper‐Based Wearable Patches for Real‐Time, Quantitative Lactate Monitoring
Ruggeri, E., Matzeu, G., Vergine, A., Nicolao, G. D., & Omenetto, F. G. (2023) · Advanced Sensor Research · doi:10.1002/adsr.202300141 · Cited by 19
Sezen-Edmonds, M., Register, J. T., Yao, Y., Glišić, B., & Loo, Y. (2016) · Small · doi:10.1002/smll.201600858 · Cited by 19
Nanosensors for animal health monitoring
Younis, S., Zia, R., Tahir, N., Bukhari, S. Z., Khan, W. S., & Bajwa, S. Z. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-824554-5.00026-4 · Cited by 22
Recent Developments in Microfluidic ‐Based Point‐of‐care Testing ( POCT ) Diagnoses
Wang, D., Chan, H. N., Liu, Z., Micheal, S., Li, L., Dehghan‐Baniani, D., Tan, M. J. A., Huang, L., Wang, J., & Wu, H. (2019) · Wiley eBooks · doi:10.1002/9783527818341.ch8 · Cited by 26
Self-citationOh, M., Kim, E., Lee, J., Jeong, I., Kim, E., Paek, J., Lee, T., Kim, D., An, S., Kim, S., et al. (2025) · Advanced Sensor Research · doi:10.1002/adsr.202500028 · Cited by 28
Kearwan, N., Promphet, N., Rodthongkum, N., Hoven, V. P., & Narupai, B. (2025) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5c10251 · Cited by 19
Cao, Q., Liang, B., Yu, C., Lü, F., Tu, T., Wei, J., & Ye, X. (2020) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2020.114358 · Cited by 17
Liu, Y., & Quan, C. (2023) · International Journal of Electrochemical Science · doi:10.1016/j.ijoes.2023.100308 · Cited by 18
Advancements in enzyme-based wearable sensors for health monitoring
Mehrotra, S., Rai, P., Saxena, A., Priya, S., & Sharma, S. (2024) · Microchemical Journal · doi:10.1016/j.microc.2024.110250 · Cited by 18
Pei, S., Ji, W., Yang, Y. F., Liu, T., Yang, S., Wu, J., Dai, J., Hou, X., Wu, Q., & Li, L. (2024) · Analysis & Sensing · doi:10.1002/anse.202400003 · Cited by 20
Starch‐Powered Biofuel Cell Activated by Logically Processed Biomolecular Signals
Mailloux, S., MacVittie, K., Privman, M., Guz, N., & Katz, E. (2014) · ChemElectroChem · doi:10.1002/celc.201400009 · Cited by 17
Upasham, S., Bhadsavle, S., & Prasad, S. (2019) · Analytical Methods · doi:10.1039/c8ay02620c · Cited by 17
Cohoon, T. J., & Bhavnani, S. P. (2020) · Personalized Medicine · doi:10.2217/pme-2019-0113 · Cited by 18
LDI-MS scanner: Laser desorption ionization mass spectrometry-based biosensor standardization
Silina, Y. E., & Morgan, B. (2020) · Talanta · doi:10.1016/j.talanta.2020.121688 · Cited by 17
On-demand lactate monitoring towards assessing physiological responses in sedentary populations
Bhide, A., Lin, K., Muthukumar, S., & Prasad, S. (2021) · The Analyst · doi:10.1039/d1an00455g · Cited by 19
Minimally Invasive Platforms in Biosensing
Pandey, P. C., Pandey, G., & Narayan, R. J. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00894 · Cited by 16
Long-term cyclic use of a sample collector for toilet-based urine analysis
Temirel, M., Yenilmez, B., & Taşoğlu, S. (2021) · Scientific Reports · doi:10.1038/s41598-021-81842-z · Cited by 16
Functional photonic structures for external interaction with flexible/wearable devices
Yoo, Y. J., Heo, S., Kim, Y. J., Ko, J. H., Mira, Z. F., & Song, Y. M. (2021) · Nano Research · doi:10.1007/s12274-021-3388-x · Cited by 18
Simultaneous multi-location wireless monitoring of sweat lactate trends
Gillan, L., Teerinen, T., Suhonen, M., Kivimäki, L., & Alastalo, A. T. (2021) · Flexible and Printed Electronics · doi:10.1088/2058-8585/ac13c4 · Cited by 19
Zhang, J., Xiang, Y., Wang, M., Basu, A., & Lu, Y. (2015) · Angewandte Chemie · doi:10.1002/ange.201507563 · Cited by 16
Wearable Technologies and Telehealth in Care Management for Chronic Illness
Zhu, X., & Cahan, A. (2015) · Health informatics · doi:10.1007/978-3-319-20765-0_22 · Cited by 18
Wearable binary cooperative polypyrrole nanofilms for chemical mapping on skin
de Morais, V. B., Corrêa, C. C., Lanzoni, E. M., Costa, C. A. R., Bufon, C. C. B., & Santhiago, M. (2019) · Journal of Materials Chemistry A · doi:10.1039/c8ta12354c · Cited by 16
Competitive USB-Powered Hand-Held Potentiostat for POC Applications: An HRP Detection Case
Montes-Cebrián, Y., Álvarez-Carulla, A., Ruiz‐Vega, G., Colomer‐Farrarons, J., Puig-Vidal, M., Baldrich, E., & Miribel‐Català, P. L. (2019) · Sensors · doi:10.3390/s19245388 · Cited by 16
Peng, M., Ning, Y., Zhang, J. W., He, Y., Xu, Z., Li, D., Yang, Y., & Ren, T.-L. (2026) · Biosensors · doi:10.3390/bios16010046 · Cited by 21
Flow by design: a guided review of microfluidics for wearable biosensors
Nava-Granados, J., Vasquez, K., Medina, B., Wang, C., Moreto, J. R., & Sempionatto, J. R. (2026) · Lab on a Chip · doi:10.1039/d5lc00628g · Cited by 15
Mass transport limitations for electrochemical sensing in low-flux excretory fluids
Komkova, M. A., Poyarkov, A. A., Eliseev, A. A., & Eliseev, A. A. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115148 · Cited by 16
Wearable Sweat Management Technologies
Wei, L., Li, Z., Dai, Z., Ding, L., Wei, H., Li, J., Zhu, H., & Zhu, Y. (2024) · Advanced Materials Technologies · doi:10.1002/admt.202301812 · Cited by 20
Tian, L., Cai, L., Ding, Z., Zhou, Y., Zhang, Y., Liu, Q., Ge, X., & Yu, C. (2024) · Microchemical Journal · doi:10.1016/j.microc.2024.110417 · Cited by 17
A Self-Powered Lactate Sensor Based on the Piezoelectric Effect for Assessing Tumor Development
Lin, J., Yuan, P., Lin, R., Xue, X., Chen, M., & Xing, L. (2024) · Sensors · doi:10.3390/s24072161 · Cited by 15
He, R., Chen, L., Chu, P., Gao, P., & Wang, J. (2024) · Analytical Methods · doi:10.1039/d4ay01002g · Cited by 16
Self-citationMulti-sensing yarns for continuous wireless sweat lactate monitoring
Napier, B. S., Matzeu, G., & Omenetto, F. G. (2024) · Communications Materials · doi:10.1038/s43246-024-00680-4 · Cited by 18
A wearable platform for biochemical sweat analysis using photonic crystal hydrogel
Wang, Y., Wu, X., Liu, Y., Zhang, J., Wang, L., & Luo, X. (2024) · Analytica Chimica Acta · doi:10.1016/j.aca.2024.343590 · Cited by 17
Duke, K., Dhungana, P., Richards, C., Preusser, K., Romeo, A. A., Gonzalez‐Garcia, J., Mummareddy, B., Cortes, P., Li, F., & Park, B. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202401040 · Cited by 18
Antiochia, R., Tortolini, C., Tasca, F., Gorton, L. G. O., & Bollella, P. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-813349-1.00001-9 · Cited by 16
Advances in Wearable Chemosensors
Korallı, P., & Mouzakis, D. E. (2021) · Chemosensors · doi:10.3390/chemosensors9050099 · Cited by 15
Kinetic changes in sweat lactate following fatigue during constant workload exercise
Okawara, H., Sawada, T., Nakashima, D., Maeda, Y., Minoji, S., Morisue, T., Katsumata, Y., Matsumoto, M., Nakamura, M., & Nagura, T. (2022) · Physiological Reports · doi:10.14814/phy2.15169 · Cited by 16
Gold Nanoparticle Treated Textile-Based Materials for Potential use as Wearable Sensors
Poinern, G. E. J. (2016) · International Journal of Sciences · doi:10.18483/ijsci.1018 · Cited by 19
Lactate Sensors on Flexible Substrates
Yang, X., Fu, T., Kota, P. K., Tjia, M., Nguyen, C., & Chiao, J. ‐. (2016) · Biosensors · doi:10.3390/bios6030048 · Cited by 16
Xu, W., Hong, L., Zheng, J., Li, M., Hua, Y., & Zhao, X. (2023) · IEEE Internet of Things Journal · doi:10.1109/jiot.2023.3317141 · Cited by 15
Phumma, R., Phamonpon, W., Rodthongkum, N., & Ummartyotin, S. (2024) · ACS Omega · doi:10.1021/acsomega.3c08000 · Cited by 14
Coşkun, A., Savaş, İ. N., Can, O., & Lippi, G. (2025) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2025.2453152 · Cited by 15
Intelligent tattoos, patches, and other wearable biosensors
Zhu, X., Liu, W., Shuang, S., Nair, M., & Li, C.-Z. (2016) · Elsevier eBooks · doi:10.1016/b978-0-08-100072-4.00006-x · Cited by 20
Oxygen‐Tolerant Hydrogen Peroxide Reduction Catalysts for Reliable Noninvasive Bioassays
Ding, Z., Chen, L., Wang, D., Zhou, H., Zhou, L., Zhu, X., Jiang, L., & Feng, X. (2019) · Small · doi:10.1002/smll.201903320 · Cited by 14
Electrochemical sensing monitoring of blood lactic acid levels in sweat during exhaustive exercise
Ma, G. (2023) · International Journal of Electrochemical Science · doi:10.1016/j.ijoes.2023.100064 · Cited by 14
Wearable and Flexible Sensors Based on 2D and Nanomaterials
Samal, R., & Rout, C. S. (2019) · Elsevier eBooks · doi:10.1016/b978-0-08-102577-2.00012-9 · Cited by 14
Unveiling complete lactate oxidation through a hybrid catalytic cascade
Franco, J. H., Grattieri, M., de Andrade, A. R., & Minteer, S. D. (2021) · Electrochimica Acta · doi:10.1016/j.electacta.2021.138044 · Cited by 16
Recent Advancements and Key Challenges of Graphene for Flexible Supercapacitors
Zequine, C., Bhoyate, S. D., de Souza, F., Arukula, R., Kahol, P. K., & Gupta, R. K. (2020) · ACS symposium series · doi:10.1021/bk-2020-1353.ch003 · Cited by 15
Flexible and Printed Electronics for Smart Clothes
Jiang, Y., & Zhu, N. (2020) · Wiley eBooks · doi:10.1002/9783527818556.ch11 · Cited by 14
Biosensing for Autoimmune Chronic Disease—A Review
Golfinopoulou, R., & Kintzios, S. E. (2023) · Chemosensors · doi:10.3390/chemosensors11070366 · Cited by 14
Ultra-Thin Chips With ISFET Array for Continuous Monitoring of Body Fluids Ph
Baghini, M. S., Vilouras, A., & Dahiya, R. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3141553 · Cited by 13
Loew, N., Shitanda, I., Goto, H., Watanabe, H., Mikawa, T., Tsujimura, S., & Itagaki, M. (2022) · Scientific Reports · doi:10.1038/s41598-022-19052-4 · Cited by 15
System-level design of an RFID sweat electrolyte sensor patch
Rose, D. P., Ratterman, M., Griffin, D. K., Hou, L., Kelley‐Loughnane, N., Naik, R. K., Hagen, J. A., Papautsky, I., & Heikenfeld, J. C. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944510 · Cited by 13
Gu, Y., Wang, J., Pan, M., Yun, Y., Wen, W., Fang, G., & Wang, S. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.12.150 · Cited by 13
Self-citationRajendran, J., Pei, X. M., Chakoma, S. M., Ghandehari, A., Negrete, J. A. T., Najafikhoshnoo, S., & Esfandyarpour, R. (2026) · Nature Biomedical Engineering · doi:10.1038/s41551-026-01670-2 · Cited by 24
Das, A., & Ding, C. (2023) · Small Methods · doi:10.1002/smtd.202301429 · Cited by 12
Flexible microcolumn array-based silk fibroin for sweat glucose monitoring
Kuang, D., Tan, Y., Han, W., Yin, Y., & Wang, C. (2025) · Analytica Chimica Acta · doi:10.1016/j.aca.2025.343857 · Cited by 13
Electrochemical Biosensor Based on Lactate Oxidase Mimic Activity of Co4N/rGO for Lactate Detection
Chen, L., Shao, R., Bao, C., Deng, L., Yang, M., & Li, X. (2025) · Journal of Analysis and Testing · doi:10.1007/s41664-025-00358-x · Cited by 12
Sevilla, G. A. T., Cordero, M. D., Nassar, J. M., Hanna, A. N., Kutbee, A. T., Arevalo, A., & Hussain, M. M. (2016) · Advanced Materials Technologies · doi:10.1002/admt.201600175 · Cited by 12
Electronic Materials, Devices, and Signals in Electrochemical Sensors
Cui, Y. (2017) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2017.2691045 · Cited by 12
Smart Materials for Wearable Healthcare Devices
Jin, H., Jin, Q., & Jian, J. (2018) · InTech eBooks · doi:10.5772/intechopen.76604 · Cited by 19
Molinnus, D., Janus, K. A., Fang, A. C., Drinic, A., Achtsnicht, S., Köpf, M., Keusgen, M., & Schöning, M. J. (2022) · physica status solidi (a) · doi:10.1002/pssa.202200100 · Cited by 13
Fluid-permeable enzymatic lactate sensors for micro-volume specimen
Kai, H., Kato, Y., Toyosato, R., & Nishizawa, M. (2018) · The Analyst · doi:10.1039/c8an00979a · Cited by 12
An Intra-Oral Optical Sensor for the Real-Time Identification and Assessment of Wine Intake
Faragó, P., Galatus, R. V., Hintea, S., Boşca, A. B., Feurdean, C. N., & Ilea, A. (2019) · Sensors · doi:10.3390/s19214719 · Cited by 13
Review—Novel Carbon Nanomaterials Based Flexible Electrochemical Biosensors
Zan, X., & Bai, H. (2021) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/abdddd · Cited by 13
Zhang, H., Wu, Z., Zhi, Z., Gao, W., Sun, W., Hua, Z., & Wu, Y. (2021) · ACS Omega · doi:10.1021/acsomega.1c04229 · Cited by 12
Electrochemical (bio-)sensors operating in human physiological fluids
Psotta, C. (2023) · doi:10.24834/isbn.9789178773992 · Cited by 17
Advancements in Human Motion Capture Technology for Sports: A Comprehensive Review
Chen, H. (2024) · Sensors and Materials · doi:10.18494/sam5084 · Cited by 13
Ike, K., Muto, K., Hioki, T., Loew, N., Shitanda, I., Takesue, M., & Okuda, M. (2025) · ACS Sensors · doi:10.1021/acssensors.5c01238 · Cited by 11
Sharkey, C. T., Aroche, A. F., Agusta, I. G., Nissan, H. E., Saha, T., Mukherjee, S., Twiddy, J. S., Dickey, M. D., Velev, O. D., & Daniele, M. A.-A. (2025) · Lab on a Chip · doi:10.1039/d5lc00590f · Cited by 13
Advancements and Obstacles in Sweat-Based Biosensors for Health Monitoring
Lihong, Z., & Li, Q. (2025) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2025.2568615 · Cited by 14
Lee, M., Kim, J.-S., Khine, M. T., Kim, S., & Gandla, S. (2023) · Nanomaterials · doi:10.3390/nano13172467 · Cited by 11
Microfluidic platforms for point of care (POC) medical diagnostics
Azhar, M., & Dendukuri, D. (2016) · Elsevier eBooks · doi:10.1016/b978-0-08-100072-4.00011-3 · Cited by 12
Wearable Chemosensors in Physiological Monitoring
Tang, Z.-Y., Cui, T., Liu, H., Jian, J., Li, D., Yang, Y., & Ren, T. (2023) · Chemosensors · doi:10.3390/chemosensors11080459 · Cited by 12
Lu, H., Wang, J., Wu, Z., Yang, M., Zhou, W., Li, Y., Li, H., Zhang, Y., Yang, J., Yu, G., et al. (2024) · Talanta · doi:10.1016/j.talanta.2024.127423 · Cited by 10
Self-citationWearable Sensors for Health Monitoring
Abreu, C., Bédard, C., Lourme, J.-C., & Piro, B. (2026) · Biosensors · doi:10.3390/bios16020093 · Cited by 14
Metadata
- Authors
- Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J.
- Affiliations
- University of California San Diego (US)
- Department of Nanoengineering, University of California San Diego, La Jolla, California 92093-0448, United States
- Corresponding author
- Wang, Joseph
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-07-05
- Volume
- 85
- Issue
- 14
- Pages
- 6553-6560
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2079026833
- Cited by
- 862
- References
- 30
- Citations by year
- 2026: 48 · 2025: 58 · 2024: 71 · 2023: 79 · 2022: 79 · 2021: 97 · 2020: 96 · 2019: 74 · 2018: 75 · 2017: 59 · 2016: 64 · 2015: 33 · 2014: 26 · 2013: 3
- FWCI
- 25.16
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Keywords
- electrochemical biosensor, sweat lactate, enzyme biosensor, flexible printed electronics, exercise physiology, cycling exercise
- MeSH terms
- Adult, Computer Systems, Epidermis, Female, Humans, Male, Sweat, Sweating, Tattooing, Biosensing Techniques, Lactic Acid, Electrochemical Techniques, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.