CoChat

Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration

Jia, Wenzhao, Bandodkar, Amay J., Valdés-Ramírez, Gabriela, Windmiller, Joshua R., Yang, Zhanjun, Ramírez, Julian, Chan, Garrett, Wang, Joseph · 2013 · Analytical Chemistry

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Abstract

The present work describes the first example of real-time noninvasive lactate sensing in human perspiration during exercise events using a flexible printed temporary-transfer tattoo electrochemical biosensor that conforms to the wearer's skin. The new skin-worn enzymatic biosensor exhibits chemical selectivity toward lactate with linearity up to 20 mM and demonstrates resiliency against continuous mechanical deformation expected from epidermal wear. The device was applied successfully to human subjects for real-time continuous monitoring of sweat lactate dynamics during prolonged cycling exercise. The resulting temporal lactate profiles reflect changes in the production of sweat lactate upon varying the exercise intensity. Such skin-worn metabolite biosensors could lead to useful insights into physical performance and overall physiological status, hence offering considerable promise for diverse sport, military, and biomedical applications.

Overview

Integrity signals

Registry

Crossref · 10.1021/ac401573r

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

4 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Show all 30 references

Research works printed but not linked: 3

  1. Chiarugi F., 2008, Comput. Cardiol., 35, 901
  2. Pilardeau P. A., 1988, J. Sports Med. Phys. Fit., 28, 247
  3. Polliack A., 1997, J. Rehabil. Res. Develop., 34, 303

Cited by

Items 601–700 of 861

Metadata

Authors
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J.
Affiliations
  • University of California San Diego (US)
  • Department of Nanoengineering, University of California San Diego, La Jolla, California 92093-0448, United States
Corresponding author
Wang, Joseph
Venue
Analytical Chemistry
Published
2013-07-05
Volume
85
Issue
14
Pages
6553-6560
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2079026833
Cited by
862
References
30
Citations by year
2026: 48 · 2025: 58 · 2024: 71 · 2023: 79 · 2022: 79 · 2021: 97 · 2020: 96 · 2019: 74 · 2018: 75 · 2017: 59 · 2016: 64 · 2015: 33 · 2014: 26 · 2013: 3
FWCI
25.16
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
Keywords
electrochemical biosensor, sweat lactate, enzyme biosensor, flexible printed electronics, exercise physiology, cycling exercise
MeSH terms
Adult, Computer Systems, Epidermis, Female, Humans, Male, Sweat, Sweating, Tattooing, Biosensing Techniques, Lactic Acid, Electrochemical Techniques, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.