The present work describes the first example of real-time noninvasive lactate sensing in human perspiration during exercise events using a flexible printed temporary-transfer tattoo electrochemical biosensor that conforms to the wearer's skin. The new skin-worn enzymatic biosensor exhibits chemical selectivity toward lactate with linearity up to 20 mM and demonstrates resiliency against continuous mechanical deformation expected from epidermal wear. The device was applied successfully to human subjects for real-time continuous monitoring of sweat lactate dynamics during prolonged cycling exercise. The resulting temporal lactate profiles reflect changes in the production of sweat lactate upon varying the exercise intensity. Such skin-worn metabolite biosensors could lead to useful insights into physical performance and overall physiological status, hence offering considerable promise for diverse sport, military, and biomedical applications.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Previously reported sweat-based and other non-invasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state14–18.”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [15]
In the citing paper
“For this reason, most wearable sweat sensors have focused on exercise, thermal, or chemically stimulated sweat produced at rates of 10’s or 100’s of nL min−1 cm−2 or higher10–23.”
From A wearable patch for continuous analysis of thermoregulatory sweat at rest (2021) · cites this paper as [15]
In the citing paper
“They are unable to draw low volumes of resting sweat rapidly into the device, limiting real-time assessment.”
From A wearable patch for continuous analysis of thermoregulatory sweat at rest (2021) · cites this paper as [15]
In the citing paper
“However, the secretion mechanism of lactic acid into sweat is complex and still unclear 79 .”
From A review of sampling, energy supply and intelligent monitoring for long-term sweat sensors (2022) · cites this paper as [79]
In the citing paper
“Although sweat lactate does not directly reflect the concurrent blood levels, it indicates the level of physical exertion experienced during prolonged exercise and can be used as a marker for athletic efficiency without invasive blood sampling.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [58]
4 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Biochemistry of exercise-induced metabolic acidosis
Robergs, R. A., Ghiasvand, F., & Parker, D. (2004) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00114.2004 · Cited by 1,304
Wireless sensor networks for personal health monitoring: Issues and an implementation
Milenković, A., Otto, C., & Jovanov, E. (2006) · Computer Communications · doi:10.1016/j.comcom.2006.02.011 · Cited by 1,023
Blood Lactate Measurements and Analysis during Exercise: A Guide for Clinicians
Goodwin, M. L., Harris, J. E., Hernández, A., & Gladden, L. B. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100414 · Cited by 554
Lactate Kinetics and Individual Anaerobic Threshold*
Stegmann, H., Kindermann, W., & Schnabel, A. (1981) · International Journal of Sports Medicine · doi:10.1055/s-2008-1034604 · Cited by 499
Tattoo-based potentiometric ion-selective sensors for epidermal pH monitoring
Bandodkar, A. J., Hung, V. W. S., Jia, W., Valdés-Ramírez, G., Windmiller, J. R., Martinez, A. G., Ramírez, J., Chan, G., Kerman, K., & Wang, J. (2013) · The Analyst · doi:10.1039/c2an36422k · Cited by 379
Self-citationKhodagholy, D., Curto, V. F., Fraser, K. J., Gurfinkel, M., Byrne, R., Diamond, D., Malliaras, G. G., Benito-Lopez, F., & Owens, R. M. (2012) · Journal of Materials Chemistry · doi:10.1039/c2jm15716k · Cited by 303
Formulation and stability of a novel artificial human sweat under conditions of storage and use
Harvey, C. J., LeBouf, R. F., & Stefaniak, A. B. (2010) · Toxicology in Vitro · doi:10.1016/j.tiv.2010.06.016 · Cited by 274
Strain Sensing Fabric for Hand Posture and Gesture Monitoring
Lorussi, F., Scilingo, E. P., Tesconi, M., Tognetti, A., & DeRossi, D. (2005) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.854510 · Cited by 207
Blood lactate parameters related to aerobic capacity and endurance performance
Yoshida, T., Chida, M., Ichioka, M., & Suda, Y. (1987) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00696368 · Cited by 183
Research works printed but not linked: 3
- Chiarugi F., 2008, Comput. Cardiol., 35, 901
- Pilardeau P. A., 1988, J. Sports Med. Phys. Fit., 28, 247
- Polliack A., 1997, J. Rehabil. Res. Develop., 34, 303
Cited by
Items 201–300 of 861
Wearable healthcare: Lessons from the past and a peek into the future
Casselman, J., Onopa, N., & Khansa, L. (2017) · Telematics and Informatics · doi:10.1016/j.tele.2017.04.011 · Cited by 129
Farzin, L., Shamsipur, M., Samandari, L., & Sheibani, S. (2018) · Microchimica Acta · doi:10.1007/s00604-018-2820-8 · Cited by 109
A wireless transmission system powered by an enzyme biofuel cell implanted in an orange
MacVittie, K., Conlon, T., & Katz, E. (2014) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2014.10.005 · Cited by 110
System Architectures in Wearable Electrochemical Sensors
Steinberg, M. D., Kassal, P., & Steinberg, I. M. (2016) · Electroanalysis · doi:10.1002/elan.201600094 · Cited by 113
Relationship Between Sweat and Blood Lactate Levels During Exhaustive Physical Exercise
Karpova, E. V., Laptev, A. I., Andreev, E. A., Karyakina, E. E., & Karyakin, A. A. (2020) · ChemElectroChem · doi:10.1002/celc.201901703 · Cited by 119
Microfabricated electrochemical sensing devices
Sassa, F., Biswas, G. C., & Suzuki, H. R. (2020) · Lab on a Chip · doi:10.1039/c9lc01112a · Cited by 116
de Oliveira, T. R., Fonseca, W. T., Setti, G. D. O., & Faria, R. C. (2018) · Talanta · doi:10.1016/j.talanta.2018.11.047 · Cited by 106
How Far Are We from Achieving Self‐Powered Flexible Health Monitoring Systems: An Energy Perspective
Yu, H., Li, N., & Zhao, N. (2020) · Advanced Energy Materials · doi:10.1002/aenm.202002646 · Cited by 107
Bendable Electro-chemical Lactate Sensor Printed with Silver Nano-particles
Abrar, M. A., Dong, Y., Lee, P. K., & Kim, W. S. (2016) · Scientific Reports · doi:10.1038/srep30565 · Cited by 105
Alshabouna, F., Lee, H. S., Barandun, G., Tan, E., Çotur, Y., Asfour, T., Gonzalez‐Macia, L., Coatsworth, P., Núñez-Bajo, E., Kim, J., et al. (2022) · Materials Today · doi:10.1016/j.mattod.2022.07.015 · Cited by 104
Kanokpaka, P., Chang, L., Wang, B.-C., Huang, T., Shih, M.-J., Hung, W., Lai, J., Ho, K., & Yeh, M. (2022) · Nano Energy · doi:10.1016/j.nanoen.2022.107464 · Cited by 103
Ultra-Small Wearable Flexible Biosensor for Continuous Sweat Analysis
Wang, J., Wang, L., Li, G., Yan, D., Liu, C., Xu, T., & Zhang, X. (2022) · ACS Sensors · doi:10.1021/acssensors.2c01533 · Cited by 107
Self-citationSmart Textiles for Personalized Sports and Healthcare
Xu, Z., Zhang, C., Wang, F., Yu, J., Yang, G., Анатольевич, С. Р., Li, Z., & Ding, B. (2025) · Nano-Micro Letters · doi:10.1007/s40820-025-01749-6 · Cited by 134
Zhang, J., Xiang, Y., Wang, M., Basu, A., & Lu, Y. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201507563 · Cited by 103
An overview of biomolecules, immobilization methods and support materials of biosensors
Asal, M., Özen, Ö., Şahinler, M., Baysal, H. T., & Polatoğlu, İ. (2018) · Sensor Review · doi:10.1108/sr-04-2018-0084 · Cited by 118
Access and Management of Sweat for Non‐Invasive Biomarker Monitoring: A Comprehensive Review
Saha, T., Caño, R. D., la Paz, E. D., Sandhu, S. S., & Wang, J. (2022) · Small · doi:10.1002/smll.202206064 · Cited by 105
Self-citationLamas‐Ardisana, P. J., Loaiza, Ó. A., Añorga, L., Jubete, E., Borghei, M., Ruiz, V., Ochoteco, E., Cabañero, G., & Grande, H. J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.01.047 · Cited by 107
Wearable Sensing Devices for Point of Care Diagnostics
Mondal, S., Zehra, N., Choudhury, A., & Iyer, P. K. (2020) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c00798 · Cited by 104
Biosensors and Chemical Sensors for Healthcare Monitoring: A Review
Arakawa, T., Dao, D. V., & Mitsubayashi, K. (2022) · IEEJ Transactions on Electrical and Electronic Engineering · doi:10.1002/tee.23580 · Cited by 109
Yüzer, E., Doğan, V., Kılıç, V., & Şen, M. (2022) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2022.132489 · Cited by 108
Medium-distance affordable, flexible and wireless epidermal sensor for pH monitoring in sweat
Mazzaracchio, V., Fiore, L. D., Nappi, S., Marrocco, G., & Arduini, F. (2020) · Talanta · doi:10.1016/j.talanta.2020.121502 · Cited by 99
Wearable Sweat Sensors: Background and Current Trends
Kaya, T., Liu, G., Ho, J. C.-T., Yelamarthi, K., Miller, K. C., Edwards, J. E., & Stannard, A. B. (2018) · Electroanalysis · doi:10.1002/elan.201800677 · Cited by 104
Asaduzzaman, M., Zahed, M. A., Sharifuzzaman, M., Reza, M. S., Hui, X., Sharma, S., Shin, Y. D., & Park, J. Y. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114846 · Cited by 106
Printed, Flexible Lactate Sensors: Design Considerations Before Performing On-Body Measurements
Payne, M. E., Zamarayeva, A. M., Pister, V. I., Yamamoto, N. A. D., & Arias, A. C. (2019) · Scientific Reports · doi:10.1038/s41598-019-49689-7 · Cited by 105
Simmers, P., Li, S. K., Kasting, G. B., & Heikenfeld, J. C. (2017) · Journal of Dermatological Science · doi:10.1016/j.jdermsci.2017.10.013 · Cited by 106
Body-Interfaced Chemical Sensors for Noninvasive Monitoring and Analysis of Biofluids
Zhao, J., Guo, H., Li, J., Bandodkar, A. J., & Rogers, J. A. (2019) · Trends in Chemistry · doi:10.1016/j.trechm.2019.07.001 · Cited by 98
Self-citationChoudhary, T., Rajamanickam, G. P., & Dendukuri, D. (2015) · Lab on a Chip · doi:10.1039/c5lc00041f · Cited by 99
KickStat: A Coin-Sized Potentiostat for High-Resolution Electrochemical Analysis
Hoilett, O. S., Walker, J., Balash, B. M., Jaras, N. J., Boppana, S., & Linnes, J. C. (2020) · Sensors · doi:10.3390/s20082407 · Cited by 95
Xu, X., Yan, B., & Lian, X. (2018) · Nanoscale · doi:10.1039/c8nr03352h · Cited by 95
Wearable physiological systems and technologies for metabolic monitoring
Gao, W., Brooks, G. A., & Klonoff, D. C. (2018) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00407.2017 · Cited by 91
Wearable Osmotic-Capillary Patch for Prolonged Sweat Harvesting and Sensing
Saha, T., Fang, J., Mukherjee, S., Dickey, M. D., & Velev, O. D. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c22730 · Cited by 94
A Concise and Systematic Review on Non-Invasive Glucose Monitoring for Potential Diabetes Management
Laha, S., Rajput, A., Laha, S. S., & Jadhav, R. (2022) · Biosensors · doi:10.3390/bios12110965 · Cited by 99
Forensics in hand: new trends in forensic devices (2013–2017)
de Oliveira, L. P., Rocha, D. P., de Araujo, W. R., Muñoz, R. A. A., Paixão, T. R. L. C., & Salles, M. O. (2018) · Analytical Methods · doi:10.1039/c8ay01389f · Cited by 100
Fully Untethered Battery-free Biomonitoring Electronic Tattoo with Wireless Energy Harvesting
Alberto, J., Leal, C., Fernandes, C. R. A., Lopes, P. A., Paisana, H., de Almeida, A. T., & Tavakoli, M. (2020) · Scientific Reports · doi:10.1038/s41598-020-62097-6 · Cited by 94
Glucose oxidase-based biosensor for glucose detection from biological fluids
Mandpe, P., Prabhakar, B. R., Gupta, H., & Shende, P. K. (2020) · Sensor Review · doi:10.1108/sr-01-2019-0017 · Cited by 95
Tripathy, A., Nine, M. J., & Silva, F. S. (2021) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2021.102380 · Cited by 92
Das, R., Nag, S., & Banerjee, P. (2023) · Molecules · doi:10.3390/molecules28031259 · Cited by 96
Recent Developments of Flexible and Stretchable Electrochemical Biosensors
Yang, X., & Cheng, H. (2020) · Micromachines · doi:10.3390/mi11030243 · Cited by 90
Textile triboelectric nanogenerators for self-powered biomonitoring
Lama, J. E., Yau, A., Chen, G., Sivakumar, A., Zhao, X., & Chen, J. (2021) · Journal of Materials Chemistry A · doi:10.1039/d1ta02518j · Cited by 90
Zhu, C., Xue, H., Zhao, H., Fei, T., Liu, S., Chen, Q., Gao, B., & Zhang, T. (2022) · Talanta · doi:10.1016/j.talanta.2022.123289 · Cited by 91
Wearable Sensor System Powered by a Biofuel Cell for Detection of Lactate Levels in Sweat
Garcia, S. O., Ulyanova, Y., Figueroa-Teran, R., Bhatt, K. H., Singhal, S., & Atanassov, P. B. (2016) · ECS Journal of Solid State Science and Technology · doi:10.1149/2.0131608jss · Cited by 96
Microfluidics by Additive Manufacturing for Wearable Biosensors: A Review
Padash, M., Enz, C., & Carrara, S. (2020) · Sensors · doi:10.3390/s20154236 · Cited by 94
Garland, N. T., Schmieder, J., Johnson, Z. T., Hjort, R. G., Chen, B., Andersen, C., Sanborn, D., Kjeldgaard, G., Pola, C. C., Li, J., et al. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c04665 · Cited by 90
Wearable sweat sensing for prolonged, semicontinuous, and nonobtrusive health monitoring
Moonen, E. J. M., Haakma, J. R., Peri, E., Pelssers, E., Mischi, M., & den Toonder, J. M. J. (2020) · VIEW · doi:10.1002/viw.20200077 · Cited by 86
Wearable device for continuous sweat lactate monitoring in sports: a narrative review
Yang, G., Hong, J., & Park, S.-B. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2024.1376801 · Cited by 100
Zhang, J., Rupakula, M., Bellando, F., Garcia-Cordero, E., Longo, J., Wildhaber, F., Herment, G., Guérin, H., & Ionescu, A. M. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00597 · Cited by 87
Bauer, M., Wunderlich, L., Weinzierl, F., Lei, Y., Duerkop, A., Alshareef, H. N., & Baeumner, A. J. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02939-4 · Cited by 89
Mukherjee, S., Suleman, S., Pilloton, R., Narang, J., & Rani, K. (2022) · Sensors · doi:10.3390/s22114228 · Cited by 96
A Review of Skin-Wearable Sensors for Non-Invasive Health Monitoring Applications
Mao, P., Li, H., & Yu, Z. (2023) · Sensors · doi:10.3390/s23073673 · Cited by 94
Assalve, G., Lunetti, P., di Cagno, A., Luca, E. W. D., Aldegheri, S., Zara, V., & Ferramosca, A. (2024) · Biosensors · doi:10.3390/bios14120574 · Cited by 99
Nanomaterial‐Based Soft Electronics for Healthcare Applications
Choi, C., Choi, M. K., Hyeon, T., & Kim, D. (2016) · ChemNanoMat · doi:10.1002/cnma.201600191 · Cited by 93
A wireless potentiostat for mobile chemical sensing and biosensing
Steinberg, M. D., Kassal, P., Kereković, I., & Steinberg, I. M. (2015) · Talanta · doi:10.1016/j.talanta.2015.05.028 · Cited by 92
Recent advances in inorganic functional nanomaterials based flexible electrochemical sensors
Yuan, F., Xia, Y., Lu, Q., Xu, Q. H., Shu, Y., & Hu, X. (2022) · Talanta · doi:10.1016/j.talanta.2022.123419 · Cited by 86
Prasad, S. N., Anderson, S. R., Joglekar, M. V., Hardikar, A. A., Bansal, V., & Ramanathan, R. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114386 · Cited by 83
Novel flexible enzyme laminate-based sensor for analysis of lactate in sweat
Tur-García, E. L., Davis, F., Collyer, S. D., Holmes, J. L., Barr, H., & Higson, S. P. J. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.11.040 · Cited by 87
Multifunctional hybrid skin patch for wearable smart healthcare applications
Yoon, S., Yoon, H., Zahed, M. A., Park, C., Kim, D., & Park, J. Y. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113685 · Cited by 87
Revolution in Flexible Wearable Electronics for Temperature and Pressure Monitoring—A Review
Butt, M. A., Kazanskiy, N. L., & Khonina, S. N. (2022) · Electronics · doi:10.3390/electronics11050716 · Cited by 94
Lin, K., Muthukumar, S., & Prasad, S. (2020) · Talanta · doi:10.1016/j.talanta.2020.120810 · Cited by 83
Textile Chemical Sensors Based on Conductive Polymers for the Analysis of Sweat
Gualandi, I., Tessarolo, M., Mariani, F., Possanzini, L., Scavetta, E., & Fraboni, B. (2021) · Polymers · doi:10.3390/polym13060894 · Cited by 89
Energy Harvesting Schemes for Wearable Devices
Hesham, R., Soltan, A., & Madian, A. H. (2021) · AEU - International Journal of Electronics and Communications · doi:10.1016/j.aeue.2021.153888 · Cited by 88
Zhao, Z., Li, Q., Dong, Y., Gong, J., Li, Z., & Zhang, J. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.131154 · Cited by 80
Physiological stress monitoring using sodium ion potentiometric microsensors for sweat analysis
Cazalé, A., Sant, W., Ginot, F., Launay, J., Savourey, G., Revol-Cavalier, F., Lagarde, J., Heinry, D., Launay, J., & Temple‐Boyer, P. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.10.114 · Cited by 84
Vertical Gold Nanowires Stretchable Electrochemical Electrodes
Zhai, Q., Wang, Y., Gong, S. P., Ling, Y., Yap, L. W., Liu, Y., Wang, J., Simon, G. P., & Cheng, W. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b03423 · Cited by 81
Self-citationWolkowicz, K. L., Aiello, E. M., Vargas, E., Teymourian, H., Tehrani, F., Wang, J., Pinsker, J. E., Doyle, F. J., Patti, M., Laffel, L. M., et al. (2020) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10201 · Cited by 87
Self-citationShitanda, I., Mitsumoto, M., Loew, N., Yoshihara, Y., Watanabe, H., Mikawa, T., Tsujimura, S., Itagaki, M., & Motosuke, M. (2020) · Electrochimica Acta · doi:10.1016/j.electacta.2020.137620 · Cited by 82
Zafar, S., Nazir, M., Bakhshi, T., Khattak, H. A., Khan, S., Bilal, M., Choo, K. R., Kwak, K. S., & Sabah, A. (2021) · IEEE Access · doi:10.1109/access.2021.3093442 · Cited by 91
Farzin, M. A., Naghib, S. M., & Rabiee, N. (2024) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.3c01633 · Cited by 85
Body Dust: Well Beyond Wearable and Implantable Sensors
Carrara, S. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3029432 · Cited by 81
Goldoni, R., Dolci, C., Boccalari, E., Inchingolo, F., Paghi, A., Strambini, L. M., Galimberti, D., & Tartaglia, G. M. (2022) · Ageing Research Reviews · doi:10.1016/j.arr.2022.101587 · Cited by 90
A review of sampling, energy supply and intelligent monitoring for long-term sweat sensors
Yang, P., Wei, G., Liu, A., Huo, F., & Zhang, Z. (2022) · npj Flexible Electronics · doi:10.1038/s41528-022-00165-9 · Cited by 77
A novel device for detecting anaerobic threshold using sweat lactate during exercise
Seki, Y., Nakashima, D., Shiraishi, Y., Ryuzaki, T., Ikura, H., Miura, K., Suzuki, M., Watanabe, T., Nagura, T., Matsumato, M., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-84381-9 · Cited by 86
Wearable microfluidic-based e-skin sweat sensors
Tabasum, H., Gill, N. K., Mishra, R., & Lone, S. (2022) · RSC Advances · doi:10.1039/d1ra07888g · Cited by 80
Development of a wearable electrochemical sensor for voltammetric determination of chloride ions
Bujes-Garrido, J., & Arcos‐Martínez, M. J. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.08.119 · Cited by 79
Construction of a flexible electrochemiluminescence platform for sweat detection
Chen, M., Cheng, S., Ji, K., Gao, J., Liu, Y., Wen, W., Zhang, X., Wang, S., & Huang, W. (2019) · Chemical Science · doi:10.1039/c9sc01937e · Cited by 77
Stretchable biofuel cell with enzyme-modified conductive textiles
Ogawa, Y., Takai, Y., Kato, Y., Kai, H., Miyake, T., & Nishizawa, M. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.063 · Cited by 76
Wireless and battery-free platforms for collection of biosignals
Stuart, T., Cai, L., Burton, A., & Gutruf, P. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113007 · Cited by 81
Silicon Micropillar Array-Based Wearable Sweat Glucose Sensor
Dervisevic, M., Alba, M., Esser, L., Tabassum, N. H., Prieto‐Simón, B., & Voelcker, N. H. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c22383 · Cited by 78
Enzyme-based amperometric biosensors: 60 years later … Quo Vadis?
Bollella, P. (2022) · Analytica Chimica Acta · doi:10.1016/j.aca.2022.340517 · Cited by 78
Toward wearable patch for sweat analysis
Dam, V. A. T., Zevenbergen, M. A. G., & van Schaijk, R. T. F. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.01.143 · Cited by 80
Pribil, M. M., Laptev, G. U., Karyakina, E. E., & Karyakin, A. A. (2014) · Analytical Chemistry · doi:10.1021/ac501547u · Cited by 75
Development of a Sensitive Self-Powered Glucose Biosensor Based on an Enzymatic Biofuel Cell
Chansaenpak, K., Kamkaew, A., Lisnund, S., Prachai, P., Ratwirunkit, P., Jingpho, T., Blay, V., & Pinyou, P. (2021) · Biosensors · doi:10.3390/bios11010016 · Cited by 75
Emerging wearable flexible sensors for sweat analysis
Heng, W., Yang, G., Kim, W. S., & Xu, K. (2021) · Bio-Design and Manufacturing · doi:10.1007/s42242-021-00171-2 · Cited by 75
Approaches of wearable and implantable biosensor towards of developing in precision medicine
Ghazizadeh, E., Naseri, Z., Deigner, H.-P., Rahimi, H., & Altıntaş, Z. (2024) · Frontiers in Medicine · doi:10.3389/fmed.2024.1390634 · Cited by 88
Potentiometric sensor for non invasive lactate determination in human sweat
Onor, M., Gufoni, S., Lomonaco, T., Ghimenti, S., Salvo, P., Sorrentino, F., & Bramanti, E. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.07.050 · Cited by 79
Ma, X., Guo, G., Wu, X., Wu, Q., Liu, F., Zhang, H., Shi, N., & Guan, Y. (2023) · Micromachines · doi:10.3390/mi14050972 · Cited by 77
Recent Progress in Application‐Oriented Self‐Powered Microelectronics
Qi, L., Kong, L., Wang, Y., Song, J., Azam, A., Zhang, Z., & Yan, J. (2023) · Advanced Energy Materials · doi:10.1002/aenm.202302699 · Cited by 79
Functional nanostructures for enzyme based biosensors: properties, fabrication and applications
Othman, A. A., Karimi, A., & Andreescu, S. (2016) · Journal of Materials Chemistry B · doi:10.1039/c6tb02009g · Cited by 76
Cavitas Sensors: Contact Lens Type Sensors & Mouthguard Sensors
Mitsubayashi, K., & Arakawa, T. (2016) · Electroanalysis · doi:10.1002/elan.201600083 · Cited by 71
Paper-based lactate biofuel cell array with high power output
Shitanda, I., Morigayama, Y., Iwashita, R., Goto, H., Aikawa, T., Mikawa, T., Hoshi, Y., Itagaki, M., Matsui, H., Tokito, S., et al. (2021) · Journal of Power Sources · doi:10.1016/j.jpowsour.2021.229533 · Cited by 73
Paul, B., Demuru, S., Lafaye, C., Saubade, M., & Briand, D. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202000910 · Cited by 73
Mishra, N., Garland, N. T., Hewett, K. A., Shamsi, M., Dickey, M. D., & Bandodkar, A. J. (2022) · ACS Sensors · doi:10.1021/acssensors.2c01669 · Cited by 72
Self-citationLee, D., Bhardwaj, J., & Jang, J. (2022) · Scientific Reports · doi:10.1038/s41598-022-06101-1 · Cited by 74
Meng, L., Chirtes, S., Liu, X., Eriksson, M., & Mak, W. C. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114742 · Cited by 68
Screen-printed organic electrochemical transistors for metabolite sensing
Scheiblin, G., Aliane, A., Strakosas, X., Curto, V. F., Coppard, R., Marchand, G., Owens, R. M., Mailley, P., & Malliaras, G. G. (2015) · MRS Communications · doi:10.1557/mrc.2015.52 · Cited by 77
He, H., Zeng, H. J., Fu, Y., Han, W., Dai, Y., Xing, L., Zhang, Y., & Xue, X. (2018) · Journal of Materials Chemistry C · doi:10.1039/c8tc03296c · Cited by 69
Review-Enzymatic and Non-Enzymatic Electrochemical Sensor for Lactate Detection in Human Biofluids
Shakhih, M. F. M., Rosslan, A. S., Noor, A. M., Ramanathan, S., Lazim, А. M., & Wahab, A. A. (2021) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ac0360 · Cited by 69
Demuru, S., Huang, C.-H., Parvez, K., Worsley, R. E., Mattana, G., Piro, B., Noël, V., Casiraghi, C., & Briand, D. (2022) · ACS Applied Nano Materials · doi:10.1021/acsanm.1c04434 · Cited by 74
Chang, Y., Chang, C.-C., Chang, L., Wang, P.-C., Kanokpaka, P., & Yeh, M. (2023) · Nano Energy · doi:10.1016/j.nanoen.2023.108505 · Cited by 68
Bandodkar, A. J., Jia, W., Ramírez, J., & Wang, J. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400808 · Cited by 67
Self-citationSoft and stretchable electrochemical biosensors
Zhai, Q., & Cheng, W. (2019) · Materials Today Nano · doi:10.1016/j.mtnano.2019.100041 · Cited by 72
Metadata
- Authors
- Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J.
- Affiliations
- University of California San Diego (US)
- Department of Nanoengineering, University of California San Diego, La Jolla, California 92093-0448, United States
- Corresponding author
- Wang, Joseph
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-07-05
- Volume
- 85
- Issue
- 14
- Pages
- 6553-6560
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2079026833
- Cited by
- 862
- References
- 30
- Citations by year
- 2026: 48 · 2025: 58 · 2024: 71 · 2023: 79 · 2022: 79 · 2021: 97 · 2020: 96 · 2019: 74 · 2018: 75 · 2017: 59 · 2016: 64 · 2015: 33 · 2014: 26 · 2013: 3
- FWCI
- 25.16
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Keywords
- electrochemical biosensor, sweat lactate, enzyme biosensor, flexible printed electronics, exercise physiology, cycling exercise
- MeSH terms
- Adult, Computer Systems, Epidermis, Female, Humans, Male, Sweat, Sweating, Tattooing, Biosensing Techniques, Lactic Acid, Electrochemical Techniques, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.