The DOI matches its Crossref record; 80 of the 80 references it cites were found in a registry or an index.
Optical Chemical pH Sensors
Abstract
ADVERTISEMENT RETURN TO ISSUEPREVReviewNEXTOptical Chemical pH SensorsDorota Wencel*, Tobias Abel, and Colette McDonaghView Author Information Optical Sensors Laboratory, School of Physical Sciences, Biomedical Diagnostics Institute, Dublin City University, Dublin, 9 Ireland*E-mail: [email protected]. Tel: +353 (1) 700 8512. Fax: +353 (1) 700 6558.Cite this: Anal. Chem. 2014, 86, 1, 15–29Publication Date (Web):November 1, 2013Publication History Published online2 December 2013Published inissue 7 January 2014https://pubs.acs.org/doi/10.1021/ac4035168https://doi.org/10.1021/ac4035168review-articleACS PublicationsCopyright © 2013 American Chemical SocietyRequest reuse permissionsArticle Views13717Altmetric-Citations436LEARN ABOUT THESE METRICSArticle Views are the COUNTER-compliant sum of full text article downloads since November 2008 (both PDF and HTML) across all institutions and individuals. These metrics are regularly updated to reflect usage leading up to the last few days.Citations are the number of other articles citing this article, calculated by Crossref and updated daily. Find more information about Crossref citation counts.The Altmetric Attention Score is a quantitative measure of the attention that a research article has received online. Clicking on the donut icon will load a page at altmetric.com with additional details about the score and the social media presence for the given article. Find more information on the Altmetric Attention Score and how the score is calculated. Share Add toView InAdd Full Text with ReferenceAdd Description ExportRISCitationCitation and abstractCitation and referencesMore Options Share onFacebookTwitterWechatLinked InRedditEmail Other access optionsGet e-Alertsclose SUBJECTS:Dyes and pigments,Fluorescence,Materials,Sensor probes,Sensors Get e-Alerts
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-46312-4 · Cited by 19,339
Fiber-Optic Chemical Sensors and Biosensors
Wolfbeis, O. S. (2006) · Analytical Chemistry · doi:10.1021/ac060490z · Cited by 1,627
Fluorescent Indicators for Intracellular pH
Han, J., & Burgess, K. (2010) · Chemical Reviews · doi:10.1021/cr900249z · Cited by 1,620
McDonagh, C., Burke, C. S., & MacCraith, B. D. (2008) · Chemical Reviews · doi:10.1021/cr068102g · Cited by 1,026
Self-citationBurns, A., Ow, H., & Wiesner, U. (2006) · Chem. Soc. Rev. · doi:10.1039/b600562b · Cited by 849
Fiber-Optic Chemical Sensors and Biosensors (2015–2019)
Wang, X.-D., & Wolfbeis, O. S. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04708 · Cited by 833
One-pot green synthesis of optically pH-sensitive carbon dots with upconversion luminescence
Jia, X., Li, J., & Wang, E. (2012) · Nanoscale · doi:10.1039/c2nr31319g · Cited by 795
Review on Hydrogel-based pH Sensors and Microsensors
Richter, A., Paschew, G., Klatt, S., Lienig, J., Arndt, K.-F., & Adler, H.-J. P. (2008) · Sensors · doi:10.3390/s8010561 · Cited by 742
The Art of Fluorescence Imaging with Chemical Sensors
Schäferling, M. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201105459 · Cited by 721
Multimodal silica nanoparticles are effective cancer-targeted probes in a model of human melanoma
Benezra, M., Penate-Medina, O., Zanzonico, P. B., Schaer, D., Ow, H., Burns, A., DeStanchina, E., Longo, V., Herz, E., Iyer, S., et al. (2011) · Journal of Clinical Investigation · doi:10.1172/jci45600 · Cited by 645
Cattrall, R. W. (1997) · Cited by 622
Fiber-Optic Chemical Sensors and Biosensors
Wolfbeis, O. S. (2008) · Analytical Chemistry · doi:10.1021/ac800473b · Cited by 571
Materials for fluorescence-based optical chemical sensors
Wolfbeis, O. S. (2005) · Journal of Materials Chemistry · doi:10.1039/b501536g · Cited by 486
Shi, W., Li, X., & Ma, H. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201202533 · Cited by 468
Optical sensing systems for microfluidic devices: A review
Kuswandi, B., Nuriman, Huskens, J., & Verboom, W. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.08.046 · Cited by 464
Fiber optic probes for biomedical optical spectroscopy
Utzinger, U., & Richards-Kortum, R. R. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1528207 · Cited by 443
Optical Fiber Sensor Technologies: Opportunities and—Perhaps—Pitfalls
Culshaw, B. (2004) · Journal of Lightwave Technology · doi:10.1109/jlt.2003.822139 · Cited by 427
Multiple fluorescent chemical sensing and imaging
Stich, M. I. J., Fischer, L. H., & Wolfbeis, O. S. (2010) · Chemical Society Reviews · doi:10.1039/b909635n · Cited by 341
Xu, H., Aylott, J. W., Kopelman, R., Miller, T. J., & Philbert, M. A. (2001) · Analytical Chemistry · doi:10.1021/ac0102718 · Cited by 331
Fiber-Optic Chemical Sensors and Biosensors
Wolfbeis, O. S. (2002) · Analytical Chemistry · doi:10.1021/ac020176e · Cited by 325
Fiber-Optic Chemical Sensors and Biosensors
Wolfbeis, O. S. (2004) · Analytical Chemistry · doi:10.1021/ac040049d · Cited by 296
Burns, A., Sengupta, P., Zedayko, T., Baird, B., & Wiesner, U. (2006) · Small · doi:10.1002/smll.200600017 · Cited by 280
Recent development and applications of optical and fiber-optic pH sensors
Lin, J. (2000) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(00)00034-0 · Cited by 271
Development of Ultrabright Semiconducting Polymer Dots for Ratiometric pH Sensing
Chan, Y.-H., Wu, C., Ye, F., Jin, Y., Smith, P. B., & Chiu, D. T. (2011) · Analytical Chemistry · doi:10.1021/ac103140x · Cited by 258
Direct optical sensors: principles and selected applications
Gauglitz, G. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2895-4 · Cited by 246
A Nanogel for Ratiometric Fluorescent Sensing of Intracellular pH Values
Peng, H., Stolwijk, J. A., Sun, L., Wegener, J., & Wolfbeis, O. S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906926 · Cited by 246
Qu, S., Chen, H., Zheng, X., Cao, J., & Liu, X. (2013) · Nanoscale · doi:10.1039/c3nr00619k · Cited by 240
Fast response photonic crystal pH sensor based on templated photo-polymerized hydrogel inverse opal
Shin, J., Braun, P. V., & Lee, W. (2010) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2010.07.018 · Cited by 229
Wang, X.-D., Stolwijk, J. A., Lang, T., Sperber, M., Meier, R. J., Wegener, J., & Wolfbeis, O. S. (2012) · Journal of the American Chemical Society · doi:10.1021/ja308830e · Cited by 223
2D luminescence imaging of pH in vivo
Schreml, S., Meier, R. J., Wolfbeis, O. S., Landthaler, M., Szeimies, R.-M., & Babilas, P. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1006945108 · Cited by 216
Jokic, T., Borisov, S. M., Saf, R., Nielsen, D. A., Kühl, M., & Klimant, I. (2012) · Analytical Chemistry · doi:10.1021/ac3011796 · Cited by 190
Evaluating Nanoparticle Sensor Design for Intracellular pH Measurements
Benjaminsen, R. V., Sun, H., Henriksen, J. R., Christensen, N. M., Almdal, K., & Andresen, T. L. (2011) · ACS Nano · doi:10.1021/nn201643f · Cited by 168
Kermis, H. R., Kostov, Y., Harms, P., & Rao, G. (2002) · Biotechnology Progress · doi:10.1021/bp0255560 · Cited by 162
Wang, X., Meier, R. J., & Wolfbeis, O. S. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201205715 · Cited by 159
Delivery and Subcellular Targeting of Dendrimer-Based Fluorescent pH Sensors in Living Cells
Albertazzi, L., Storti, B., Marchetti, L., & Beltram, F. (2010) · Journal of the American Chemical Society · doi:10.1021/ja105689u · Cited by 145
Simultaneous Photographing of Oxygen and pH In Vivo Using Sensor Films
Meier, R. J., Schreml, S., Wang, X., Landthaler, M., Babilas, P., & Wolfbeis, O. S. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201104530 · Cited by 135
Optical fiber pH sensors based on layer-by-layer electrostatic self-assembled Neutral Red
Goicoechea, J., Zamarreño, C. R., Matias, I. R., & Arregui, F. J. (2008) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2008.01.056 · Cited by 132
Wu, S., Li, Z., Han, J., & Han, S. (2011) · Chemical Communications · doi:10.1039/c1cc14627k · Cited by 132
Do optical sensors really measure pH?
Janata, J. (1987) · Analytical Chemistry · doi:10.1021/ac00136a019 · Cited by 130
Towards Smart Tattoos: Implantable Biosensors for Continuous Glucose Monitoring
Heo, Y. J., & Takeuchi, S. (2012) · Advanced Healthcare Materials · doi:10.1002/adhm.201200167 · Cited by 122
Du, F., Ming, Y., Zeng, F., Yu, C., & Wu, S. (2013) · Nanotechnology · doi:10.1088/0957-4484/24/36/365101 · Cited by 119
A ratiometric optical imaging probe for intracellular pH based on modulation of europium emission
Pál, R., & Parker, D. (2008) · Organic & Biomolecular Chemistry · doi:10.1039/b718993a · Cited by 117
A pH plate fluorosensor (optode) for early diagenetic studies of marine sediments
Hulth, S., Aller, R. C., Engström, P., & Selander, E. (2002) · Limnology and Oceanography · doi:10.4319/lo.2002.47.1.0212 · Cited by 114
Fluorescent pH Sensor Based on Ag@SiO2 Core–Shell Nanoparticle
Bai, Z., Chen, R., Si, P., et al. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am401528w · Cited by 113
Schutting, S., Borisov, S. M., & Klimant, I. (2013) · Analytical Chemistry · doi:10.1021/ac303595v · Cited by 109
Borisov, S. M., Seifner, R., & Klimant, I. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4617-4 · Cited by 108
Principles of Chemical and Biological Sensors
Deng, G. (1999) · Materials and Manufacturing Processes · doi:10.1080/10426919908907570 · Cited by 107
High performance optical ratiometric sol–gel-based pH sensor
Wencel, D., MacCraith, B. D., & McDonagh, C. M. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2008.12.066 · Cited by 107
Self-citationReview Paper: Materials and Techniques forIn VivopH Monitoring
Korostynska, O., Arshak, K. I., Gill, E., & Arshak, A. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2007.912522 · Cited by 107
Silica nanoparticles for cell imaging and intracellular sensing
Korzeniowska, B., Nooney, R. I., Wencel, D., & McDonagh, C. M. (2013) · Nanotechnology · doi:10.1088/0957-4484/24/44/442002 · Cited by 103
Self-citationNovel coumarin-based fluorescent pH indicators, probes and membranes covering a broad pH range
Vasylevska, A. S., Karasyov, A. A., Borisov, S. M., et al. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-1061-6 · Cited by 103
An optical pH sensor with a linear response over a broad range
Lin, J., & Liu, D. (2000) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00840-5 · Cited by 98
Blair, S., Lowe, M. P., Mathieu, C. E., Parker, D., Senanayake, P. K., & Kataky, R. (2001) · Inorganic Chemistry · doi:10.1021/ic010371w · Cited by 94
Stability of new optical pH sensing material based on cross-linked poly(vinyl alcohol) copolymer
Čajlaković, M., Lobnik, A., & Werner, T. (2002) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)01598-7 · Cited by 89
Development of a colorimetric microfluidic pH sensor for autonomous seawater measurements
Rérolle, V. M. C., Floquet, C. F. A., Harris, A. J. K., Mowlem, M. C., Bellerby, R. G. J., & Achterberg, E. P. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.05.008 · Cited by 89
Aigner, D., Ungerböck, B., Mayr, T., et al. (2013) · Journal of Materials Chemistry C · doi:10.1039/c3tc31130a · Cited by 85
A novel Eu(III)-based luminescent chemosensor: determining pH in a highly acidic environment
Gunnlaugsson, T. (2001) · Tetrahedron Letters · doi:10.1016/s0040-4039(01)01935-9 · Cited by 83
Zhu, Q., Aller, R. C., & Fan, Y. (2005) · Environmental Science & Technology · doi:10.1021/es051023m · Cited by 82
Aigner, D., Borisov, S. M., Petritsch, P., & Klimant, I. (2013) · Chemical Communications · doi:10.1039/c3cc39151e · Cited by 82
Hu, J., Zhang, X.-Z., Wang, D., Hu, X., Liu, T., Zhang, G., & Liu, S. (2011) · Journal of Materials Chemistry · doi:10.1039/c1jm13575a · Cited by 80
Liu, Z., Liu, J., & Chen, T. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.10.017 · Cited by 76
Rapid method for the preparation of a robust optical pH sensor
Kermis, H. R., Kostov, Y. V., & Rao, G. (2003) · The Analyst · doi:10.1039/b304902g · Cited by 69
Chen, Y., Chen, H.-A., Hung, Y., Chien, F., Chen, P., & Mou, C. (2011) · RSC Advances · doi:10.1039/c1ra00586c · Cited by 68
Lifetime-Based pH Sensor System Based on a Polymer-Supported Ruthenium(II) Complex
Clarke, Y., Xu, W., Demas, J. N., et al. (2000) · Analytical Chemistry · doi:10.1021/ac000111g · Cited by 67
New fluorescent pH sensors based on covalently linkable PET rhodamines
Aigner, D., Borisov, S. M., Orriach-Fernández, F. J., et al. (2012) · Talanta · doi:10.1016/j.talanta.2012.05.039 · Cited by 62
A s prayable luminescent pH sensor and its use for wound imaging in vivo
Schreml, S., Meier, R. J., Weiß, K. T., Cattani, J., Flittner, D., Gehmert, S., Wolfbeis, O. S., Landthaler, M., & Babilas, P. (2012) · Experimental Dermatology · doi:10.1111/exd.12042 · Cited by 60
Full-range optical pH sensor based on imaging techniques
Capel-Cuevas, S., Cuéllar, M. P., de Orbe-Payá, I., Pegalajar, M. C., & Capitán-Vallvey, L. F. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.09.033 · Cited by 59
Wang, X., Meier, R. J., & Wolfbeis, O. S. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201200813 · Cited by 59
Jezierski, S., Belder, D., & Nagl, S. (2012) · Chemical Communications · doi:10.1039/c2cc38093e · Cited by 51
Turel, M., Čajlaković, M., Austin, E. A. D., et al. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.11.047 · Cited by 50
Multilayered Assemblies Composed of Brilliant Yellow and Poly(allylamine) for an Optical pH Sensor
Egawa, Y., Hayashida, R., & Anzai, J. (2006) · Analytical Sciences · doi:10.2116/analsci.22.1117 · Cited by 49
Alkali treatment of dye-doped sol–gel glass films for rapid optical pH sensing
Ismail, F., Malins, C., & Goddard, N. J. (2002) · The Analyst · doi:10.1039/b108370h · Cited by 48
Two-photon nano-PEBBLE sensors: subcellular pH measurements
Ray, A., Lee, Y.-E. K., Epstein, T., Kim, G., & Kopelman, R. (2011) · The Analyst · doi:10.1039/c1an15046d · Cited by 47
Lü, H., Jin, Y., Tian, Y., Zhang, W., Holl, M. R., & Meldrum, D. R. (2011) · Journal of Materials Chemistry · doi:10.1039/c1jm13754a · Cited by 46
Magnetic and fluorescent core–shell nanoparticles for ratiometric pH sensing
Lapresta-Fernández, A., Doussineau, T., Dutz, S., Steiniger, F., Moro, A. J., & Mohr, G. J. (2011) · Nanotechnology · doi:10.1088/0957-4484/22/41/415501 · Cited by 37
Optical sensor for interstitial pH measurements
Baldini, F., Giannetti, A. E., & Mencaglia, A. A. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2714807 · Cited by 31
Single‐cell monitoring using fiberoptic nanosensors
Vo‐Dinh, T., & Zhang, Y. (2010) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.112 · Cited by 30
Magnetic nanocomposites of Fe3O4/SiO2-FITC with pH-dependent fluorescence emission
Zhang, Y., Gong, S. W. Y., Lü, J., et al. (2009) · Chinese Chemical Letters · doi:10.1016/j.cclet.2009.03.038 · Cited by 30
Controlled deposition of sol–gel sensor material using hemiwicking
Mikkelsen, M. B., Marie, R., Hansen, J. H., Wencel, D., McDonagh, C. M., Nielsen, H. O., & Kristensen, A. S. (2011) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/21/11/115008 · Cited by 21
Self-citationA Wide-range Luminescent pH Sensor Based on Ruthenium(II) Complex
KIM, H. J. (2009) · Bulletin of the Korean Chemical Society · doi:10.5012/bkcs.2009.30.3.539 · Cited by 16
Cited by
Fluorescent probes and bioimaging: alkali metals, alkaline earth metals and pH
Yin, J., Hu, Y., & Yoon, J. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00275j · Cited by 645
Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Application of metal and metal oxide nanoparticles@MOFs
Falcaro, P., Ricco, R., Yazdi, A., Imaz, I., Furukawa, S., Maspoch, D., Ameloot, R., Evans, J. D., & Doonan, C. J. (2016) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2015.08.002 · Cited by 620
Metal oxides based electrochemical pH sensors: Current progress and future perspectives
Manjakkal, L., Szwagierczak, D., & Dahiya, R. (2020) · Progress in Materials Science · doi:10.1016/j.pmatsci.2019.100635 · Cited by 481
Shi, Z., Han, X., Hu, W., Bai, H., Peng, B., Ji, L., Fan, Q., Li, L., & Huang, W. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00234h · Cited by 469
Metadata
- Authors
- Wencel, D., Abel, T., & McDonagh, C.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-12-02
- Volume
- 86
- Issue
- 1
- Pages
- 15-29
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2327407167
- Cited by
- 541
- References
- 80
- FWCI
- 23.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.