The DOI matches its Crossref record; 635 of the 635 references it cites were found in a registry or an index.
Skin-Interfaced Wearable Sweat Sensors for Precision Medicine
Open accessAbstract
Wearable sensors hold great potential in empowering personalized health monitoring, predictive analytics, and timely intervention toward personalized healthcare. Advances in flexible electronics, materials science, and electrochemistry have spurred the development of wearable sweat sensors that enable the continuous and noninvasive screening of analytes indicative of health status. Existing major challenges in wearable sensors include: improving the sweat extraction and sweat sensing capabilities, improving the form factor of the wearable device for minimal discomfort and reliable measurements when worn, and understanding the clinical value of sweat analytes toward biomarker discovery. This review provides a comprehensive review of wearable sweat sensors and outlines state-of-the-art technologies and research that strive to bridge these gaps. The physiology of sweat, materials, biosensing mechanisms and advances, and approaches for sweat induction and sampling are introduced. Additionally, design considerations for the system-level development of wearable sweat sensing devices, spanning from strategies for prolonged sweat extraction to efficient powering of wearables, are discussed. Furthermore, the applications, data analytics, commercialization efforts, challenges, and prospects of wearable sweat sensors for precision medicine are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 401–600 of 635
Baker, L. B., Chavez, P. J. D. D., Ungaro, C. T., Sopeña, B. C., Nuccio, R. P., Reimel, A. J., & Barnes, K. A. (2018) · European Journal of Applied Physiology · doi:10.1007/s00421-018-4048-z · Cited by 122
Jagannath, B., Lin, K., Pali, M. L., Sankhala, D., Muthukumar, S., & Prasad, S. (2020) · Inflammatory Bowel Diseases · doi:10.1093/ibd/izaa191 · Cited by 122
Pushing the Limits of Flexibility and Stretchability of Solar Cells: A Review
Dauzon, E., Sallenave, X., Plesse, C., Goubard, F., Amassian, A., & Anthopoulos, T. D. (2021) · Advanced Materials · doi:10.1002/adma.202101469 · Cited by 121
A novel OFET-based biosensor for the selective and sensitive detection of lactate levels
Minami, T., Sato, T., Minamiki, T., Fukuda, K., Kumaki, D., & Tokito, S. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.06.002 · Cited by 119
Sweat Testing in Opioid Users with a Sweat Patch
Kintz, P., Tracqui, A., Mangin, P., & Edel, Y. (1996) · Journal of Analytical Toxicology · doi:10.1093/jat/20.6.393 · Cited by 119
Lenz, M., Müller, F.-J., Zenke, M., & Schuppert, A. (2016) · Scientific Reports · doi:10.1038/srep25696 · Cited by 117
Noninvasive wearable electroactive pharmaceutical monitoring for personalized therapeutics
Lin, S., Yu, W., Wang, B., Zhao, Y., En, K., Zhu, J., Cheng, X., Zhou, C., Lin, H., Wang, Z., et al. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2009979117 · Cited by 117
Baker, L. B., Ungaro, C. T., Sopeña, B. C., Nuccio, R. P., Reimel, A. J., Carter, J. M., Stofan, J. R., & Barnes, K. A. (2018) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00867.2017 · Cited by 116
Zhang, Y., Chen, Y., Huang, J., Liu, Y., Peng, J., Chen, S., Song, K., Ouyang, X., Cheng, H., & Wang, X. (2020) · Lab on a Chip · doi:10.1039/d0lc00400f · Cited by 115
Lin, S., Wang, B., Zhao, Y., Shih, R., Cheng, X., Yu, W., Hojaiji, H., Lin, H., Hoffman, C., Ly, D., et al. (2020) · ACS Sensors · doi:10.1021/acssensors.9b01727 · Cited by 114
Redox-Active Self-Assembled Monolayers for Solid-Contact Polymeric Membrane Ion-Selective Electrodes
Fibbioli, M., Bandyopadhyay, K., Liu, S., Echegoyen, L. A., Enger, O., Diederich, F., Gingery, D., Bühlmann, P., Persson, H. H. J., Suter, U. W., et al. (2002) · Chemistry of Materials · doi:10.1021/cm0109589 · Cited by 114
Gay, V. C., & Leijdekkers, P. (2015) · Journal of Medical Internet Research · doi:10.2196/jmir.5094 · Cited by 114
Validity of Transdermal Alcohol Monitoring: Fixed and Self‐Regulated Dosing
Sakai, J. T., Mikulich‐Gilbertson, S. K., Long, R. J., & Crowley, T. J. (2006) · Alcoholism Clinical and Experimental Research · doi:10.1111/j.1530-0277.2006.00004.x · Cited by 113
Recent Developments in Aptasensors for Diagnostic Applications
Liu, L. S., Wang, F., Ge, Y., & Lo, P. K. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c14788 · Cited by 113
Sun, M., Gu, Y., Pei, X., Wang, J., Liu, J., Ma, C., Bai, J., & Zhou, M. (2021) · Nano Energy · doi:10.1016/j.nanoen.2021.106061 · Cited by 112
Animal‐free alternatives and the antibody iceberg
Gray, A., Bradbury, A. R. M., Knappik, A., Plückthun, A., Borrebaeck, C. A. K., & Dübel, S. (2020) · Nature Biotechnology · doi:10.1038/s41587-020-0687-9 · Cited by 111
High Performance Printed AgO-Zn Rechargeable Battery for Flexible Electronics
Yin, L., Scharf, J., Ma, J., Doux, J., Redquest, C., Le, V. L., Yin, Y., Ortega, J., Wei, X., Wang, J., et al. (2021) · eScholarship (California Digital Library) · Cited by 110
A review of textile dye-sensitized solar cells for wearable electronics
Bandara, T. M. W. J., Hansadi, J. M. C., & Bella, F. (2022) · Ionics · doi:10.1007/s11581-022-04582-8 · Cited by 110
A Self‐Powered Wearable Sensor for Continuous Wireless Sweat Monitoring
Gai, Y., Wang, E., Liu, M., Xie, L., Bai, Y., Yang, Y., Xue, J., Qu, X., Yuan, X., Li, L., et al. (2022) · Small Methods · doi:10.1002/smtd.202200653 · Cited by 109
Self-citationTHE AMINO ACIDS OF HUMAN SWEAT
Hier, S. W., Cornbleet, T., & Bergeim, O. (1946) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(17)35010-x · Cited by 108
Solid Contact Ion-Selective Electrodes with a Well-Controlled Co(II)/Co(III) Redox Buffer Layer
Zou, X. U., Cheong, J. H., Taitt, B. J., & Bühlmann, P. (2013) · Analytical Chemistry · doi:10.1021/ac4022117 · Cited by 107
Relationship Between Sweat and Blood Lactate Levels During Exhaustive Physical Exercise
Karpova, E. V., Laptev, A. I., Andreev, E. A., Karyakina, E. E., & Karyakin, A. A. (2020) · ChemElectroChem · doi:10.1002/celc.201901703 · Cited by 107
Laser-engraved graphene for flexible and wearable electronics
Wang, M., Yang, Y., & Gao, W. F. (2021) · Trends in Chemistry · doi:10.1016/j.trechm.2021.09.001 · Cited by 106
Self-citationMachine Learning and IoT for prediction and detection of stress
Pandey, P. S. (2017) · International Conference on Computational Science and Its Applications · doi:10.1109/iccsa.2017.8000018 · Cited by 105
Wearable and self-cleaning hybrid energy harvesting system based on micro/nanostructured haze film
Ren, Z., Zheng, Q., Wang, H., Guo, H., Miao, L., Wan, J., Xu, C., Cheng, S., & Zhang, H. (2019) · Nano Energy · doi:10.1016/j.nanoen.2019.104243 · Cited by 105
Self-citationZhou, Z., & Zare, R. N. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04498 · Cited by 104
Jagannath, B., Lin, K., Pali, M. L., Sankhala, D., Muthukumar, S., & Prasad, S. (2021) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10220 · Cited by 104
Diet and cardiovascular diseases.
Kromhout, D. (2001) · PubMed · Cited by 103
Moon, J., Teymourian, H., De la Paz, E., Sempionatto, J. R., Mahato, K., Sonsa‐ard, T., Huang, N., Longardner, K., Litvan, I., & Wang, J. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202106674 · Cited by 103
Kanokpaka, P., Chang, L., Wang, B.-C., Huang, T., Shih, M.-J., Hung, W., Lai, J., Ho, K., & Yeh, M. (2022) · Nano Energy · doi:10.1016/j.nanoen.2022.107464 · Cited by 103
ZnO Nanorod Integrated Flexible Carbon Fibers for Sweat Cortisol Detection
Madhu, S., Anthuuvan, A. J., Ramasamy, S., Manickam, P., Bhansali, S., Nagamony, P., & Chinnuswamy, V. (2020) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.9b00730 · Cited by 102
Thin-Film Microbiosensors for Glucose−Lactate Monitoring
Jobst, G., Moser, I., Varahram, M., Svasek, P., Aschauer, E., Trajanoski, Z., Wach, P., Kotanko, P., Skrabal, F., & Urban, G. (1996) · Analytical Chemistry · doi:10.1021/ac950630x · Cited by 102
Yüzer, E., Doğan, V., Kılıç, V., & Şen, M. (2022) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2022.132489 · Cited by 102
Trovato, V., Sfameni, S., Rando, G., Rosace, G., Libertino, S., Ferri, A., & Plutino, M. R. (2022) · Molecules · doi:10.3390/molecules27175709 · Cited by 102
Buono, M. J., Claros, R., DeBoer, T., & Wong, J. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.90503.2008 · Cited by 101
Analyzing and Mapping Sweat Metabolomics by High-Resolution NMR Spectroscopy
Kutyshenko, V. P., Molchanov, M. V., Beskaravayny, P., Uversky, V. N., & Timchenko, M. (2011) · PLoS ONE · doi:10.1371/journal.pone.0028824 · Cited by 100
Simmers, P., Li, S. K., Kasting, G. B., & Heikenfeld, J. C. (2017) · Journal of Dermatological Science · doi:10.1016/j.jdermsci.2017.10.013 · Cited by 100
Printable elastomeric electrodes with sweat-enhanced conductivity for wearables
Lv, J., Thangavel, G., Li, Y., Xiong, J., Gao, D., Ciou, J., Tan, M., Aziz, I., Chen, S., Chen, J., et al. (2021) · Science Advances · doi:10.1126/sciadv.abg8433 · Cited by 99
Printing processes and their potential for RFID printing
Blayo, A., & Pineaux, B. (2005) · doi:10.1145/1107548.1107559 · Cited by 98
Zhao, Z., Li, Q., Chen, L., Yu, Z., Gong, J., Li, Z., & Zhang, J. (2020) · Lab on a Chip · doi:10.1039/d0lc01075h · Cited by 97
Kim, S. B., Koo, J., Yoon, J., Hourlier‐Fargette, A., Lee, B.-R., Chen, S., Jo, S., Choi, J., Oh, Y. S., Lee, G., et al. (2019) · Lab on a Chip · doi:10.1039/c9lc01045a · Cited by 96
Finger sweat analysis enables short interval metabolic biomonitoring in humans
Brunmair, J., Gotsmy, M., Niederstaetter, L., Neuditschko, B., Bileck, A., Slany, A., Feuerstein, M. L., Langbauer, C., Janker, L., Zanghellini, J., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-26245-4 · Cited by 96
Rendering SU-8 hydrophilic to facilitate use in micro channel fabrication
Tenje, M., Marie, R., Calleja, M., & Boisen, A. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/12/003 · Cited by 95
Effect of Charged Group Spacer Length on Hydration State in Zwitterionic Poly(sulfobetaine) Brushes
Higaki, Y., Inutsuka, Y., Sakamaki, T., Terayama, Y., Takenaka, A., Higaki, K., Yamada, N. L., Moriwaki, T., Ikemoto, Y., & Takahara, A. (2017) · Langmuir · doi:10.1021/acs.langmuir.7b01935 · Cited by 95
Wearable Osmotic-Capillary Patch for Prolonged Sweat Harvesting and Sensing
Saha, T., Fang, J., Mukherjee, S., Dickey, M. D., & Velev, O. D. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c22730 · Cited by 94
Effect of Heat Acclimation on Sweat Minerals
CHINEVERE, T. D., KENEFICK, R. W., CHEUVRONT, S. N., LUKASKI, H. C., & SAWKA, M. N. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181641c04 · Cited by 93
Zhang, Z., Chen, Y., & Guo, J. (2018) · Physica E Low-dimensional Systems and Nanostructures · doi:10.1016/j.physe.2018.09.007 · Cited by 93
Garcia-Cordero, E., Bellando, F., Zhang, J., Wildhaber, F., Longo, J., Guérin, H., & Ionescu, A. M. (2018) · ACS Nano · doi:10.1021/acsnano.8b07413 · Cited by 93
Sweat gland organoids contribute to cutaneous wound healing and sweat gland regeneration
Diao, J., Liu, J., Wang, S., Chang, M., Wang, X., Guo, B., Yu, Q., Yan, F., Su, Y., & Wang, Y. (2019) · Cell Death & Disease · doi:10.1038/s41419-019-1485-5 · Cited by 92
Sonner, Z., Wilder, E., Gaillard, T. R., Kasting, G. B., & Heikenfeld, J. C. (2017) · Lab on a Chip · doi:10.1039/c7lc00364a · Cited by 92
A modified anaerobic method of sweat collection
Boysen, T. C., Yanagawa, S., Sato, F., & Sato, K. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.56.5.1302 · Cited by 91
Laser‐Induced Graphene Composites for Printed, Stretchable, and Wearable Electronics
Tehrani, F., Beltrán‐Gastélum, M., Sheth, K., Karajić, A., Yin, L., Kumar, R., Soto, F., Kim, J., Wang, J., Barton, S., et al. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201900162 · Cited by 89
Wearable piezoelectric mass sensor based on pH sensitive hydrogels for sweat pH monitoring
Scarpa, E., Mastronardi, V., Guido, F., Algieri, L., Qualtieri, A., Fiammengo, R., Rizzi, F., & Vittorio, M. D. (2020) · Scientific Reports · doi:10.1038/s41598-020-67706-y · Cited by 89
Sweat urea, uric acid and creatinine concentrations in uraemic patients
Al‐Tamer, Y. Y., Hadi, E. A., & Al-Badrani, I. E. I. (1997) · Urological Research · doi:10.1007/bf01294662 · Cited by 88
Time-Dependent Wetting Behavior of PDMS Surfaces with Bioinspired, Hierarchical Structures
Mishra, H., Schrader, A. M., Lee, D. W., Gallo, A., Chen, S., Kaufman, Y., Das, S., & Israelachvili, J. N. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b10721 · Cited by 88
Elpa, D. P., Chiu, H., Wu, S., & Urban, P. L. (2020) · Trends in Endocrinology and Metabolism · doi:10.1016/j.tem.2020.11.009 · Cited by 88
Sengupta, P., Pramanik, K., Datta, P., & Sarkar, P. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112072 · Cited by 87
Nicotine Monitoring with a Wearable Sweat Band
Tai, L., Ahn, C. H., Nyein, H. Y. Y., Ji, W., Bariya, M., Lin, Y., Li, L., & Javey, A. (2020) · ACS Sensors · doi:10.1021/acssensors.0c00791 · Cited by 87
Wearable tesla valve-based sweat collection device for sweat colorimetric analysis
Shi, H., Cao, Y., Zeng, Y., Zhou, Y., Wen, W., Zhang, C., Zhao, Y., & Chen, Z. (2022) · Talanta · doi:10.1016/j.talanta.2022.123208 · Cited by 87
Eccrine Sweat as a Biofluid for Profiling Immune Biomarkers
Katchman, B. A., Zhu, M., Blain Christen, J., & Anderson, K. S. (2018) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201800010 · Cited by 86
Drug Testing in Addicts: A Comparison Between Urine, Sweat, and Hair
Kintz, P. (1996) · Therapeutic Drug Monitoring · doi:10.1097/00007691-199608000-00024 · Cited by 86
Wearable Biosupercapacitor: Harvesting and Storing Energy from Sweat
Lv, J., Yin, L., Chen, X., Jeerapan, I., Silva‐López, C., Li, Y., Le, M., Lin, Z., Wang, L., Trifonov, A., et al. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202102915 · Cited by 86
A machine learning-based on-demand sweat glucose reporting platform
Sankhala, D., Sardesai, A. U., Pali, M. L., Lin, K., Jagannath, B., Muthukumar, S., & Prasad, S. (2022) · Scientific Reports · doi:10.1038/s41598-022-06434-x · Cited by 86
Tripathi, S. R., Miyata, E., Ishai, P. B., & Kawase, K. (2015) · Scientific Reports · doi:10.1038/srep09071 · Cited by 85
Stubbs, R. J., O'Reilly, L. M., Whybrow, S., Fuller, Z., Johnstone, A. M., Livingstone, M. B. E., Ritz, P., & Horgan, G. W. (2014) · British Journal of Nutrition · doi:10.1017/s0007114514000154 · Cited by 85
Potentiometric Sensors with Carbon Black Supporting Platinum Nanoparticles
Paczosa‐Bator, B., Cabaj, L., Piech, R., & Skupień, K. (2013) · Analytical Chemistry · doi:10.1021/ac402885y · Cited by 85
Zhang, J., Rupakula, M., Bellando, F., Garcia-Cordero, E., Longo, J., Wildhaber, F., Herment, G., Guérin, H., & Ionescu, A. M. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00597 · Cited by 85
Pei, X., Sun, M., Wang, J., Bai, J., Bo, X., & Zhou, M. (2022) · Small · doi:10.1002/smll.202205061 · Cited by 84
A novel device for detecting anaerobic threshold using sweat lactate during exercise
Seki, Y., Nakashima, D., Shiraishi, Y., Ryuzaki, T., Ikura, H., Miura, K., Suzuki, M., Watanabe, T., Nagura, T., Matsumato, M., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-84381-9 · Cited by 83
Finding Hidden Signals in Chemical Sensors Using Deep Learning
Cho, S., Lee, Y., Lee, S., Kang, H., Kim, J., Choi, J., Ryu, J., Joo, H., Jung, H., & Kim, J. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c00137 · Cited by 82
Liu, Y., Huang, X., Zhou, J., Yiu, C. K., Song, Z. F., Huang, W. B., Nejad, S. K., Li, H., Wong, T. H., Yao, K., et al. (2022) · Advanced Science · doi:10.1002/advs.202104635 · Cited by 82
Electrochemical bioaffinity sensors for salivary biomarkers detection
Campuzano, S., Yánez-Sedeño, P., & Pingarrón, J. M. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.10.002 · Cited by 81
Zhou, Z., Shu, T., Sun, Y., Si, H., Peng, P., Su, L., & Zhang, X. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113530 · Cited by 81
Sweat test for cystic fibrosis: Wearable sweat sensor vs. standard laboratory test
Choi, D.-H., Thaxton, A., Jeong, I. C., Kim, K., Sosnay, P. R., Cutting, G. R., & Searson, P. C. (2018) · Journal of Cystic Fibrosis · doi:10.1016/j.jcf.2018.03.005 · Cited by 80
Cui, C., Childress, V., Piao, Y., Michel, M., Johnson, A. A., Kunisada, M., Ko, M. S. H., Kaestner, K. H., Marmorstein, A. D., & Schlessinger, D. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1117213109 · Cited by 80
Gidado, I. M., Qassem, M., Triantis, I. F., & Kyriacou, P. A. (2022) · Sensors · doi:10.3390/s22197151 · Cited by 80
Kammarchedu, V., Butler, D., & Ebrahimi, A. (2022) · Analytica Chimica Acta · doi:10.1016/j.aca.2022.340447 · Cited by 79
Sweat induction from an isolated eccrine sweat gland
Sato, K. (1973) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1973.225.5.1147 · Cited by 79
Liu, N., Huang, S., Yao, B., Xie, J., Wu, X., & Fu, X. (2016) · Scientific Reports · doi:10.1038/srep34410 · Cited by 79
Schwerdt, H. N., Zhang, E., Kim, M. J., Yoshida, T., Stanwicks, L. L., Amemori, S., Dağdeviren, H. E., Langer, R., Cima, M. J., & Graybiel, A. M. (2018) · Communications Biology · doi:10.1038/s42003-018-0147-y · Cited by 78
Construction of a flexible electrochemiluminescence platform for sweat detection
Chen, M., Cheng, S., Ji, K., Gao, J., Liu, Y., Wen, W., Zhang, X., Wang, S., & Huang, W. (2019) · Chemical Science · doi:10.1039/c9sc01937e · Cited by 77
Recent Advances in Flexible Field‐Effect Transistors toward Wearable Sensors
Li, M.-Z., Han, S., & Zhou, Y. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000113 · Cited by 77
(2017) · PubMed Central · Cited by 76
Ethical Considerations of Wearable Technologies in Human Research
Tu, J., & Gao, W. F. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100127 · Cited by 76
Self-citationLiu, T.-L., Dong, Y., Chen, S., Zhou, J., Ma, Z., & Li, J. (2022) · Science Advances · doi:10.1126/sciadv.abo7049 · Cited by 76
Mark, H., & Harding, C. R. (2013) · International Journal of Cosmetic Science · doi:10.1111/ics.12019 · Cited by 75
Biopower-on-Skin: Electricity generation from sweat-eating bacteria for self-powered E-Skins
Mohammadifar, M., Tahernia, M., Yang, J. H., Koh, A., & Choi, S. (2020) · Nano Energy · doi:10.1016/j.nanoen.2020.104994 · Cited by 75
Sweat Ethanol Concentrations are Highly Correlated with Co‐Existing Blood Values in Humans
Buono, M. J. (1999) · Experimental Physiology · doi:10.1111/j.1469-445x.1999.01798.x · Cited by 74
Proteomic and peptidomic analysis of human sweat with emphasis on proteolysis
Yu, Y., Prassas, I., Muytjens, C. M. J., & Diamandis, E. P. (2017) · Journal of Proteomics · doi:10.1016/j.jprot.2017.01.005 · Cited by 74
Paul, B., Demuru, S., Lafaye, C., Saubade, M., & Briand, D. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202000910 · Cited by 73
(2022) · Saudi Medical Journal · doi:10.15537/1658-3175.7962 · Cited by 72
Csősz, É., Emri, G., Kalló, G., Tsaprailis, G., & Tőzsér, J. (2015) · Journal of the European Academy of Dermatology and Venereology · doi:10.1111/jdv.13221 · Cited by 72
Ultra-simple wearable local sweat volume monitoring patch based on swellable hydrogels
Zhao, F. J., Bonmarin, M., Chen, Z. C., Larson, M., Fay, D., Runnoe, D., & Heikenfeld, J. (2020) · Lab on a Chip · doi:10.1039/c9lc00911f · Cited by 71
A Capacitive Sweat Rate Sensor for Continuous and Real-Time Monitoring of Sweat Loss
Choi, D., Gonzales, M., Kitchen, G. B., Phan, D., & Searson, P. C. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01219 · Cited by 71
Solid-contact pH-selective electrode using multi-walled carbon nanotubes
Crespo, G. A., Gugsa, D., Macho, S., & Rius, F. X. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3127-8 · Cited by 70
Sweat lactate response between males with high and low aerobic fitness
Green, J. M., Pritchett, R. C., Crews, T. R., McLester, J. R., & Tucker, D. C. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0968-2 · Cited by 70
High-performance flexible potentiometric sensing devices using free-standing graphene paper
Ping, J. F., Wang, Y., Fan, K., Tang, W., Wu, J. F., & Ying, Y. B. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb20664e · Cited by 70
Wang, C., Shim, E., Chang, H., Lee, N., Kim, H. R., & Park, J. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112652 · Cited by 69
Sweat in the pathogenesis of atopic dermatitis
Murota, H., Yamaga, K., Ono, E., & Katayama, I. (2018) · Allergology International · doi:10.1016/j.alit.2018.06.003 · Cited by 68
Flexible Superwettable Tapes for On-Site Detection of Heavy Metals
He, X., Xu, T., Gao, W. F., Xu, L., Pan, T., & Zhang, X. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04536 · Cited by 68
Self-citationXia, H.-Q., Tang, H., Zhou, B., Li, Y., Zhang, X., Shi, Z., Deng, L., Song, R., Li, L., Zhang, Z., et al. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.127962 · Cited by 68
Chen, Y., Kuan, W., & Liu, C. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17103377 · Cited by 68
Sweat Lactate, Ammonia, and Urea in Rugby Players
Alvear-Ordenes, I., García-López, D., De Paz, J. A., & González-Gallego, J. (2005) · International Journal of Sports Medicine · doi:10.1055/s-2004-830380 · Cited by 67
Nour, E. S., Sandberg, M. O., Willander, M., & Nur, O. (2014) · Nano Energy · doi:10.1016/j.nanoen.2014.07.014 · Cited by 67
Free Amino-acids in Human Sweat from Different Parts of the Body
Hadorn, B., Hanimann, F., ANDERS, P., Curtius, H. ‐., & HALVERSON, R. (1967) · Nature · doi:10.1038/215416a0 · Cited by 67
Role of calcium in cholinergic and adrenergic mechanisms of eccrine sweat secretion
Sato, K., & Sato, F. (1981) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1981.241.3.c113 · Cited by 67
Francis, J., Stamper, I., Heikenfeld, J. C., & Gomez, E. F. (2018) · Lab on a Chip · doi:10.1039/c8lc00968f · Cited by 67
In vivo studies on receptor pharmacology of the human eccrine sweat gland
Low, P. A., Opfer‐Gehrking, T. L., & Kihara, M. (1992) · Clinical Autonomic Research · doi:10.1007/bf01824208 · Cited by 66
A sweat-activated, wearable microbial fuel cell for long-term, on-demand power generation
Ryu, J., Landers, M., & Choi, S. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114128 · Cited by 66
Large‐Scale Patterning of Reactive Surfaces for Wearable and Environmentally Deployable Sensors
Matzeu, G., Mogas‐Soldevila, L., Li, W., Naidu, A., Turner, T. H., Gu, R., Blumeris, P. R., Song, P., Pascal, D. G., Guidetti, G., et al. (2020) · Advanced Materials · doi:10.1002/adma.202001258 · Cited by 65
Zhao, G., Ling, Y., Su, Y., Chen, Z., Mathai, C. J., Emeje, O., Brown, A., Alla, D. R., Huang, J., Kim, C., et al. (2022) · Science Advances · doi:10.1126/sciadv.abp9734 · Cited by 63
Kihara, M., Opfer‐Gehrking, T. L., & Low, P. A. (1993) · Muscle & Nerve · doi:10.1002/mus.880160612 · Cited by 62
A novel organotypic 3D sweat gland model with physiological functionality
Klaka, P., Gruedl, S., Banowski, B., Giesen, M., Sättler, A., Proksch, P., Welss, T., & Förster, T. (2017) · PLoS ONE · doi:10.1371/journal.pone.0182752 · Cited by 62
Synergy of cAMP and calcium signaling pathways in CFTR regulation
Bozóky, Z., Ahmadi, S., Milman, T., Kim, T. H., Du, K., Paola, M. D., Pasyk, S., Pekhletski, R., Keller, J. P., Bear, C. E., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1613546114 · Cited by 61
Cheng, X., Wang, B., Zhao, Y., Hojaiji, H., Lin, S., Shih, R. M., Lin, H., Tamayosa, S., Ham, B., Stout, P., et al. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201908507 · Cited by 61
Effects of High and Low Blood Lactate Concentrations on Sweat Lactate Response
Green, J. M., Bishop, P. A., Muir, I. H., McLester Jr, J. R., & Heath, H. E. (2000) · International Journal of Sports Medicine · doi:10.1055/s-2000-8483 · Cited by 60
Effect of local acetylcholinesterase inhibition on sweat rate in humans
Shibasaki, M., & Crandall, C. G. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.3.757 · Cited by 60
A Weavable and Scalable Cotton‐Yarn‐Based Battery Activated by Human Sweat for Textile Electronics
Xiao, G., Ju, J., Lu, H., Shi, X., Wang, X., Wang, W., Xia, Q., Zhou, G., Sun, W., Li, C. M., et al. (2022) · Advanced Science · doi:10.1002/advs.202103822 · Cited by 59
Baker, L. B., Seib, M. S., Barnes, K. A., Brown, S. D., King, M. A., Chavez, P. J. D. D., Qu, S., Archer, J., Wolfe, A. S., Stofan, J. R., et al. (2022) · Advanced Materials Technologies · doi:10.1002/admt.202200249 · Cited by 59
Hooton, K., Han, W., & Li, L. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b01930 · Cited by 58
CATCH (Cortisol Apta WATCH): ‘Bio-mimic alarm’ to track Anxiety, Stress, Immunity in human sweat
Pali, M. L., Jagannath, B., Lin, K., Upasham, S., Sankhalab, D., Upashama, S., Muthukumar, S., & Prasad, S. (2021) · Electrochimica Acta · doi:10.1016/j.electacta.2021.138834 · Cited by 58
Minagawa, H., Onodera, K., Fujita, H., Sakamoto, T., Akitomi, J., Kaneko, N., Shiratori, I., Kuwahara, M., Horii, K., & Waga, I. (2017) · Scientific Reports · doi:10.1038/srep42716 · Cited by 57
The concentration of sodium in thermal sweat
Bulmer, M. G., & Forwell, G. D. (1956) · The Journal of Physiology · doi:10.1113/jphysiol.1956.sp005506 · Cited by 56
Sweat testing for heroin and metabolites in a heroin maintenance program
Kintz, P., Brenneisen, R., Bundeli, P., & Mangin, P. J. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.5.736 · Cited by 56
Development of a flexible, sweat-based neuropeptide Y detection platform
Churcher, N. K. M., Upasham, S., Rice, P., Bhadsavle, S., & Prasad, S. (2020) · RSC Advances · doi:10.1039/d0ra03729j · Cited by 56
Machine learning guided electrochemical sensor for passive sweat cortisol detection
Shahub, S., Upasham, S., Ganguly, A., & Prasad, S. (2022) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2022.100527 · Cited by 56
Effect of physical training on exercise-induced sweating in women
Araki, T., Matsushita, K., Umeno, K., Tsujino, A., & Toda, Y. (1981) · Journal of Applied Physiology · doi:10.1152/jappl.1981.51.6.1526 · Cited by 55
van Egmond, K., Wright, C. C. J., Livingston, M., & Kuntsche, E. N. (2020) · Alcoholism Clinical and Experimental Research · doi:10.1111/acer.14432 · Cited by 55
Flexible and wearable supercapacitors: A short review
Atta, M. M., & Fahim, R. A. (2021) · Journal of Energy Storage · doi:10.1016/j.est.2021.103475 · Cited by 55
Li, J., Yin, T., & Qin, W. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.03.038 · Cited by 54
Grygołowicz‐Pawlak, E., Wyglądacz, K., Sęk, S., Bilewicz, R., Brzózka, Z., & Malinowska, E. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.12.038 · Cited by 54
Ishige, Y., Klink, S., & Schuhmann, W. W. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201600111 · Cited by 54
Carbon threads sweat-based supercapacitors for electronic textiles
Lima, N. R. C., Baptista, A. C., Faustino, B. M. M., Taborda, S., Marques, A., & Ferreira, I. (2020) · Scientific Reports · doi:10.1038/s41598-020-64649-2 · Cited by 54
Integrated Aptasensor Array for Sweat Drug Analysis
Zhang, X., Tang, Y., Wu, H., Wang, Y., Niu, L., & Li, F. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c00736 · Cited by 54
Platinum nanoparticles intermediate layer in solid-state selective electrodes
Paczosa‐Bator, B., Cabaj, L., Piech, R., & Skupień, K. (2012) · The Analyst · doi:10.1039/c2an35933b · Cited by 53
Human frontal sweat rate and lactate concentration during heat exposure and exercise
Fellmann, N., Grizard, G., & Coudert, J. (1983) · Journal of Applied Physiology · doi:10.1152/jappl.1983.54.2.355 · Cited by 52
Sakaguchi, K., Hirota, Y., Hashimoto, N., Ogawa, W., Hamaguchi, T., Matsuo, T., Miyagawa, J.-I., Namba, M., Sato, T., Okada, S., et al. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700313 · Cited by 50
Excretion of MBDB and BDB in Urine, Saliva, and Sweat Following Single Oral Administration
Kintz, P. (1997) · Journal of Analytical Toxicology · doi:10.1093/jat/21.7.570 · Cited by 50
Lin, H., Zhao, Y., Lin, S., Wang, B., Yeung, C. J., Cheng, X., Wang, Z., Cai, T., Yu, W., King, K., et al. (2019) · Lab on a Chip · doi:10.1039/c9lc00418a · Cited by 50
Noninvasive monitoring of plasma l-dopa concentrations using sweat samples in Parkinson's disease
Tsunoda, M., Hirayama, M., Tsuda, T., & Ohno, K. (2015) · Clinica Chimica Acta · doi:10.1016/j.cca.2014.12.032 · Cited by 49
Sato, K., Ohtsuyama, M., & Samman, G. (1991) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(08)80117-x · Cited by 49
LeGrys, V. A., McColley, S. A., Li, Z., & Farrell, P. M. (2010) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2010.07.053 · Cited by 49
Normal human sweat contains interleukin-8
Jones, A. P., Webb, L. M. C., Anderson, A. O., Leonardo, E. J., & Rot, A. (1995) · Journal of Leukocyte Biology · doi:10.1002/jlb.57.3.434 · Cited by 49
Xue, W., Tan, X., Oo, M. K. K., Kulkarni, G. S., Ilgen, M. A., & Fan, X. (2020) · The Analyst · doi:10.1039/c9an02498k · Cited by 49
Shay, T., Saha, T., Dickey, M. D., & Velev, O. D. (2020) · Biomicrofluidics · doi:10.1063/5.0010417 · Cited by 49
Plasma ammonia is the principal source of ammonia in sweat
Czarnowski, D., Górski, J., Jóźwiuk, J., & Boroń-Kaczmarska, A. (1992) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00705070 · Cited by 48
Isoyama, G., Oyama, K., & Taguchi, M. (2020) · Lab on a Chip · doi:10.1039/d0lc00316f · Cited by 48
Bioelectricity production from sweat-activated germination of bacterial endospores
Ryu, J., & Choi, S. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113293 · Cited by 48
Qualitative Detection of Opiates in Sweat by EIA and GC-MS
Fogerson, R., Schoendorfer, D. W., Fay, J., & Spiehler, V. R. (1997) · Journal of Analytical Toxicology · doi:10.1093/jat/21.6.451 · Cited by 47
Internet-of-Things security: Denial of service attacks
Arış, A., Oktuğ, S., & Örs, B. (2015) · Signal Processing and Communications Applications Conference (SIU) · doi:10.1109/siu.2015.7129976 · Cited by 47
Further studies on the role of redox-active monolayer as intermediate phase of solid-state sensors
Grygołowicz‐Pawlak, E., Plachecka, K., Brzózka, Z., & Malinowska, E. (2006) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2006.09.029 · Cited by 46
Human thermoregulation in sauna.
Leppäluoto, J. (1988) · PubMed · Cited by 46
Design Framework and Sensing System for Noninvasive Wearable Electroactive Drug Monitoring
Lin, S., Wang, B., Yu, W., Castillo, K. N., Hoffman, C., Cheng, X., Zhao, Y., Gao, Y., Wang, Z., Lin, H., et al. (2020) · ACS Sensors · doi:10.1021/acssensors.9b02233 · Cited by 46
Studies of Ph of Sweat Produced by Different Forms of Stimulation*
Herrmann, F., & Mandol, L. (1955) · Journal of Investigative Dermatology · doi:10.1038/jid.1955.36 · Cited by 45
Automatic Detection of COVID-19 Based on Short-Duration Acoustic Smartphone Speech Analysis
Stasak, B., Huang, Z., Razavi, S., Joachim, D., & Epps, J. (2021) · Journal of Healthcare Informatics Research · doi:10.1007/s41666-020-00090-4 · Cited by 45
Sweat Facilitated Amino Acid Losses in Male Athletes during Exercise at 32-34°C
Dunstan, R. H., Sparkes, D. L., Dascombe, B. J., Macdonald, M. M., Evans, C. A., Stevens, C. J., Crompton, M. J., Gottfries, J., Franks, J., Murphy, G., et al. (2016) · PLOS ONE · doi:10.1371/journal.pone.0167844 · Cited by 43
Open nanofluidic films with rapid transport and no analyte exchange for ultra-low sample volumes
Twine, N. B., Norton, R. M., Brothers, M. C., Hauke, A., Gomez, E. F., & Heikenfeld, J. (2018) · Lab on a Chip · doi:10.1039/c8lc00186c · Cited by 43
Joseph, R. E., Oyler, J. M., Wstadik, A. T., Ohuoha, C., & Cone, E. J. (1998) · Journal of Analytical Toxicology · doi:10.1093/jat/22.1.6 · Cited by 43
Urea transporters and sweat response to uremia
Keller, R. W., Bailey, J. L., Wang, Y., Klein, J. D., & Sands, J. M. (2016) · Physiological Reports · doi:10.14814/phy2.12825 · Cited by 42
Talkhooncheh, A. H., Yu, Y., Agarwal, A., Kuo, W. W.-T., Chen, K.-C., Wang, M., Hoskuldsdottir, G., Gao, W. F., & Emami, A. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.3035491 · Cited by 42
Self-citationQuantifying plasticizer leakage from ion-selective membranes – a nanosponge approach
Kisiel, A., Kałuża, D., Paterczyk, B., Maksymiuk, K., & Michalska, A. (2020) · The Analyst · doi:10.1039/c9an02621e · Cited by 41
An autonomous wearable system for diurnal sweat biomarker data acquisition
Hojaiji, H., Zhao, Y., Gong, M. C., Mallajosyula, M., Tan, J., Lin, H., Hojaiji, A. M., Lin, S., Milla, C. E., Madni, A. M., et al. (2020) · Lab on a Chip · doi:10.1039/d0lc00820f · Cited by 41
Wearable Microbial Fuel Cells for Sustainable Self-Powered Electronic Skins
Su, Y., Lü, L., & Zhou, M. (2022) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.2c00313 · Cited by 41
Wang, F., Liu, L. S., Lau, C., Chang, T. J. H., Tam, D. Y., Leung, H. M., Tin, C., & Lo, P. K. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b14324 · Cited by 40
Mihályi, C., Iordanov, I., Törőcsik, B., & Csanády, L. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2007910117 · Cited by 40
Developing a platform to evaluate and assess the security of wearable devices
Hale, M. L., Lotfy, K., Gamble, R., Walter, C., & Lin, J. (2018) · Digital Communications and Networks · doi:10.1016/j.dcan.2018.10.009 · Cited by 39
Wan, K., Taroni, P. J., Liu, Z., Liu, Y., Tu, Y., Santagiuliana, G., Hsia, I., Zhang, H., Fenwick, O., Krause, S., et al. (2019) · Advanced Electronic Materials · doi:10.1002/aelm.201900582 · Cited by 39
Osmotically Enabled Wearable Patch for Sweat Harvesting and Lactate Quantification
Saha, T., Fang, J., Mukherjee, S., Knisely, C. T., Dickey, M. D., & Velev, O. D. (2021) · Micromachines · doi:10.3390/mi12121513 · Cited by 39
SLOCK (sensor for circadian clock): passive sweat-based chronobiology tracker
Upasham, S., & Prasad, S. (2020) · Lab on a Chip · doi:10.1039/d0lc00134a · Cited by 38
Monitoring Pregnant Women's Illicit Opiate and Cocaine Use With Sweat Testing
Brunet, B., Barnes, A. J., Choo, R. E., Mura, P., Jones, H. E., & Huestis, M. A. (2010) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0b013e3181c13aaf · Cited by 38
Surface contamination artificially elevates initial sweat mineral concentrations
Ely, M. R., Kenefick, R. W., Cheuvront, S. N., Chinevere, T. D., Lacher, C. P., Lukaski, H. C., & Montain, S. J. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01437.2010 · Cited by 38
Wang, J., Sun, M., Pei, X., Zheng, L., Ma, C., Liu, J., Cao, M., Bai, J., & Zhou, M. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202209697 · Cited by 38
Prieto, M. A., Vázquez, J. A., & Murado, M. A. (2015) · The Analyst · doi:10.1039/c4an02136c · Cited by 36
Spatial extension of sudomotor axon reflex sweating in human skin
Riedl, B., Nischik, M., Birklein, F., Neundörfer, B., & Handwerker, H. O. (1998) · Journal of the Autonomic Nervous System · doi:10.1016/s0165-1838(98)00016-2 · Cited by 36
Bovell, D. L. (2018) · Experimental Dermatology · doi:10.1111/exd.13556 · Cited by 36
Enhancing glucose flux into sweat by increasing paracellular permeability of the sweat gland
Jajack, A., Brothers, M., Kasting, G., & Heikenfeld, J. (2018) · PLOS ONE · doi:10.1371/journal.pone.0200009 · Cited by 35
Exercise-Induced Trace Mineral Element Concentration in Regional Versus Whole-Body Wash-Down Sweat
Baker, L. B., Stofan, J. R., Lukaski, H. C., & Horswill, C. A. (2011) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.21.3.233 · Cited by 35
Na, C. H., Sharma, N., Madugundu, A. K., Chen, R., Aksit, M. A., Rosson, G. D., Cutting, G. R., & Pandey, A. (2019) · Molecular & Cellular Proteomics · doi:10.1074/mcp.ra118.001101 · Cited by 35
Souza, S. L., Graça, G., & Oliva, A. (2018) · Skin Research and Technology · doi:10.1111/srt.12412 · Cited by 34
Recent advances in human sweat metabolomics for lung cancer screening
Delgado‐Povedano, M. D. M., Calderón-Santiago, M., Priego‐Capote, F., Gámez, B. J., & de Castro, M. D. L. (2016) · Metabolomics · doi:10.1007/s11306-016-1116-4 · Cited by 34
Flexible, low volume detection of chronobiology biomarkers from human sweat
Upasham, S., Thai, K., Muthyala, R., & Prasad, S. (2019) · The Analyst · doi:10.1039/c9an01968e · Cited by 34
Peng, Z., Liu, R., Xu, Z., Chi, H., Wang, Z., & Zhao, Y. J. (2022) · Applied Materials Today · doi:10.1016/j.apmt.2022.101623 · Cited by 34
Functions of calcium in sweat secretion
Prompt, C. A., & Quinton, P. (1978) · Nature · doi:10.1038/272171a0 · Cited by 33
Urea transfer across the sweat glands
Komives, G. K., Robinson, S., & Roberts, J. T. (1966) · Journal of Applied Physiology · doi:10.1152/jappl.1966.21.6.1681 · Cited by 33
Fu, F., Wang, J., Tan, Y., & Yu, J. (2021) · Macromolecular Rapid Communications · doi:10.1002/marc.202100776 · Cited by 33
Upasham, S., Bhide, A., Lin, K., & Prasad, S. (2020) · Future Science OA · doi:10.2144/fsoa-2020-0097 · Cited by 32
Ichimura, Y., Kuritsubo, T., Nagamine, K., Nomura, A., Shitanda, I., & Tokito, S. (2021) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03156-3 · Cited by 32
Männel, M. J., Weigel, N., Hauck, N., Heida, T., & Thiele, J. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202100094 · Cited by 32
Zeng, X., & Qin, W. (2019) · Talanta · doi:10.1016/j.talanta.2019.120570 · Cited by 31
Design and Testing of Autonomous Chargeable and Wearable Sweat/Ionic Liquid‐Based Supercapacitors
Selvam, S., Park, Y., & Yim, J. (2022) · Advanced Science · doi:10.1002/advs.202201890 · Cited by 30
PCA-based unsupervised feature extraction for gene expression analysis of COVID-19 patients
Fujisawa, K., Shimo, M., Taguchi, Y., Ikematsu, S., & Miyata, R. (2021) · Scientific Reports · doi:10.1038/s41598-021-95698-w · Cited by 29
Buja, A., Damiani, G., Gini, R., Visca, M., Federico, B., Donato, D., Francesconi, P., Marini, A., Donatini, A., Brugaletta, S., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0091340 · Cited by 28
Earth-abundant non-toxic perovskite nanocrystals for solution processed solar cells
Aina, S., Villacampa, B., & Bernechea, M. (2021) · Materials Advances · doi:10.1039/d1ma00245g · Cited by 28
Passive Sweat-Based Pruritic Cytokine Detection and Monitoring System
Upasham, S., Rice, P., Shahub, S., Dhamu, V. N., & Prasad, S. (2022) · ECS Sensors Plus · doi:10.1149/2754-2726/ac82bc · Cited by 28
USAGE CRIMINEL DE SUBSTANCES PSYCHO-ACTIVES : LE PROBLÈME DE LA DURÉE DE DÉTECTION
Kintz, P., Villain, M., Cirimele, V., et al. (2002) · Acta Clinica Belgica · doi:10.1179/acb.2002.072 · Cited by 27
Abbasiasl, T., Mirlou, F., Istif, E., Koydemir, H. C., & Beker, L. (2022) · Sensors & Diagnostics · doi:10.1039/d2sd00032f · Cited by 27
The Expression of AQP5 and UTs in the Sweat Glands of Uremic Patients
Xie, L., Jin, L., Feng, J., & Lv, J. (2017) · BioMed Research International · doi:10.1155/2017/8629783 · Cited by 25
Real life practice of sweat testing in Europe
Cirilli, N., Southern, K. W., Buzzetti, R., Barben, J., Naehrlich, L., Munck, À., Wilschanski, M. A., Boeck, K. D., & Derichs, N. (2017) · Journal of Cystic Fibrosis · doi:10.1016/j.jcf.2017.09.002 · Cited by 25
Aranyosi, A. J., Model, J. B., Zhang, M. Z., Lee, S. P., Leech, A., Li, W., Seib, M. S., Chen, S., Reny, N., Wallace, J. C., et al. (2020) · Journal of Investigative Dermatology · doi:10.1016/j.jid.2020.05.107 · Cited by 25
Clinical translation of biomedical sensors for sports medicine
Seshadri, D. R., Magliato, S. N., Voos, J. E., & Drummond, C. K. (2019) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2019.1612474 · Cited by 24
Cited by
Materials-Driven Soft Wearable Bioelectronics for Connected Healthcare
Gong, S., Lu, Y., Yin, J., Levin, A., & Cheng, W. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00502 · Cited by 411
Self-Powered Sensing in Wearable Electronics─A Paradigm Shift Technology
Tang, W., Sun, Q., & Wang, Z. L. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00305 · Cited by 300
Applied body-fluid analysis by wearable devices
Brasier, N., Wang, J., Gao, W., Sempionatto, J. R., Dincer, C., Ates, H. C., Güder, F., Olenik, S., Schauwecker, I., Schaffarczyk, D., et al. (2024) · Nature · doi:10.1038/s41586-024-08249-4 · Cited by 298
Self-citationPorous Conductive Textiles for Wearable Electronics
Ding, Y., Jiang, J., Wu, Y., Zhang, Y., Zhou, J., Zhang, Y., Huang, Q., & Zheng, Z. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00507 · Cited by 269
Artificial intelligence-powered electronic skin
Xu, C., Solomon, S. A., & Gao, W. (2023) · Nature Machine Intelligence · doi:10.1038/s42256-023-00760-z · Cited by 259
Self-citation
Metadata
- Authors
- Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W.
- Venue
- Chemical Reviews
- Publisher
- American Chemical Society (ACS)
- Published
- 2023-03-27
- Volume
- 123
- Issue
- 8
- Pages
- 5049-5138
- ISSN
- 0009-2665 (ISSN-L)
- 1520-6890
- OpenAlex
- W4360989166
- Cited by
- 712
- References
- 635
- FWCI
- 21.08
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.