Design of Mucoadhesive PLGA Microparticles for Ocular Drug Delivery
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Topically administered ocular drug delivery systems typically face severe bioavailability challenges because of the natural protective mechanisms of eyes. The rational design of drug delivery systems that are able to persist on corneal surfaces for sustained drug release is critical to tackle this problem. In this study, we fabricated monodisperse chitosan-coated PLGA microparticles with tailored diameters from 5 to 120 μm by capillary microfluidic techniques and conducted detailed investigations of their mucoadhesion to artificial mucin-coated substrates. AFM force spectroscopy revealed strong instant adhesion to mucins, whereas the adhesion force, rupture length, and adhesion energy were positively correlated to the particle diameter and contact time. Particle detachment tests under shear flow in a microfluidic mucin-coated flow cell were in accord with the AFM measurements and revealed that microparticles smaller than 25 μm exhibited strong persistence in the flow cell, withstanding high shear rates up to 28,750 s –1 which are equivalent to the harshest in vivo ocular conditions. A simple scaling analysis connects the AFM and detachment tests, and reveals the existence of a threshold diameter below which mucoadhesion performance essentially saturates—an important insight in managing the opposing design criteria of enhanced mucoadhesion and slow, sustained drug delivery. Our findings thus pave the way for the rational design of mucoadhesive microparticulate ocular drug delivery systems that are capable of enhancing the bioavailability of topically applied drugs to eyes, as well as to other tissues whose epithelial surfaces contain mucosae.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Poly Lactic-co-Glycolic Acid (PLGA) as Biodegradable Controlled Drug Delivery Carrier
Makadia, H. K., & Siegel, S. J. (2011) · Polymers · doi:10.3390/polym3031377 · Cited by 4,816
Gaudana, R., Ananthula, H. K., Parenky, A., & Mitra, A. K. (2010) · The AAPS Journal · doi:10.1208/s12248-010-9183-3 · Cited by 1,406
The basics and underlying mechanisms of mucoadhesion
SMART, J. (2005) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2005.07.001 · Cited by 1,167
Rapid transport of large polymeric nanoparticles in fresh undiluted human mucus
Lai, S. K., O'Hanlon, D. E., Harrold, S., Man, S. T., Wang, Y.-Y., Cone, R., & Hanes, J. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0608611104 · Cited by 1,050
De Campos, A. M., Sánchez, A., Gref, R., Calvo, P., & Alonso, M. J. (2003) · European Journal of Pharmaceutical Sciences · doi:10.1016/s0928-0987(03)00178-7 · Cited by 234
Cited by
Recent advances in the formulation of PLGA microparticles for controlled drug delivery
Lagreca, E., Onesto, V., Di Natale, C., La Manna, S., Netti, P. A., & Vecchione, R. (2020) · Progress in Biomaterials · doi:10.1007/s40204-020-00139-y · Cited by 284
Vlachopoulos, A., Karlioti, G., Balla, E., Daniilidis, V., Kalamas, T., Stefanidou, M., Bikiaris, N. D., Christodoulou, E., Koumentakou, I., Karavas, E., et al. (2022) · Pharmaceutics · doi:10.3390/pharmaceutics14020359 · Cited by 277
“prepared chitosan-coated PLGA microparticles with controlled diameters from 5 to 120 μm using capillary microfluidic techniques for ocular drug delivery systems [74].”
MethodChitosan and its Derivatives for Ocular Delivery Formulations: Recent Advances and Developments
Zamboulis, A., Nanaki, S., Michailidou, G., Koumentakou, I., Lazaridou, M., Ainali, N. M., Xanthopoulou, E., & Bikiaris, D. N. (2020) · Polymers · doi:10.3390/polym12071519 · Cited by 187
Han, Y., Xu, C., Shi, H., Yu, F., Zhong, Y., Liu, Z., Loh, X. J., Wu, Y.-L., Li, Z., & Li, C. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.129734 · Cited by 30
Kailasam, V., Kumara, B. N., Prasad, K. S., & Nirmal, J. (2024) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2024.114208 · Cited by 19
Metadata
- Authors
- Ding, D., Kundukad, B., Somasundar, A., Vijayan, S., Khan, S. A., & Doyle, P. S.
- Venue
- ACS Applied Bio Materials
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-08-16
- Volume
- 1
- Issue
- 3
- Pages
- 561-571
- ISSN
- 2576-6422 (ISSN-L)
- OpenAlex
- W2885781018
- Cited by
- 58
- References
- 5
- FWCI
- 1.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.